RESUMO
BACKGROUND: For decades, the tobacco industry has engineered the sensory characteristics of combustible tobacco products including the degree of harshness experienced at the back of the throat. Commonly referred to as 'throat hit', this harshness derives from absorption of gas phase nicotine and other constituents by the sensory nerves. People who use tobacco products associate throat hit with the positive psychological effects of nicotine, making it a secondary reinforcer for smoking. On the other hand, high throat hit can make products aversive to naïve nicotine users and serves as a barrier to consumption of tobacco products. METHODS: We developed a first-principles theoretical model to predict nicotine absorption in the throat as a function of electronic nicotine delivery systems (ENDS) device power, liquid composition and puffing topography. The predicted nicotine absorption was compared with subjective throat harshness reported by human participants. We also simulated several ENDS use scenarios to identify the most important processes and factors that govern nicotine absorption in the throat. RESULTS: Across various ENDS configurations, we found that computed nicotine gas absorption in the throat was associated with subjective harshness scores (r=0.62; p<0.00001). We also found that liquid nicotine concentration, nicotine form, aerosol temperature and inhalation rate strongly influence nicotine absorption in the throat per unit of nicotine emitted by an ENDS. CONCLUSIONS: Nicotine throat hit can be predicted and manipulated through ENDS device and liquid design variables. Regulating ENDS throat hit is feasible and may help reduce product appeal to nicotine-naïve individuals while maintaining acceptability for smokers.
RESUMO
Electronic nicotine delivery systems, often referred to as e-cigarettes, are popular tobacco products frequently advertised as safer alternatives to traditional cigarettes despite preliminary data suggesting a potential negative cardiovascular impact. Cardiorespiratory fitness is a critical cardiovascular health marker that is diminished in individuals who consume traditional tobacco products. Whether the use of e-cigarettes impacts cardiorespiratory fitness is currently unknown. Thus, the purpose of this study was to investigate the impact of regular e-cigarette use on cardiorespiratory fitness in young healthy adults. Twenty-six users of e-cigarettes (ECU, 13 males, and 13 females; age: 24 ± 3 yr; e-cigarette usage 4 ± 2 yr) and 16 demographically matched nonusers (NU, 6 males, and 10 females; age: 23 ± 3 yr) participated in this study. Cardiorespiratory fitness was measured by peak oxygen consumption (VÌo2peak) during a cardiopulmonary exercise test. Measurements of chronotropic response, hemodynamic, oxygen extraction, and utilization were also evaluated. Our results suggest that regular users of e-cigarettes exhibited significantly lower peak oxygen consumption when compared with nonusers, even when controlled by fat-free mass and lean body mass. Hemodynamic changes were not different between both groups during exercise, whereas lower chronotropic responses and skeletal muscle oxygen utilization were observed in users of e-cigarettes. Results from the present study demonstrate that young, apparently healthy, regular users of e-cigarettes exhibit significantly reduced cardiorespiratory fitness, lower chronotropic response, and impaired skeletal muscle oxygen utilization during exercise. Overall, our findings contribute to the growing body of evidence that supports adverse effects of regular e-cigarette use on cardiovascular health.NEW & NOTEWORTHY E-cigarettes are tobacco products frequently used by youth and young adults. Little is known about the long-term health effects of their prolonged use. Results from the present study demonstrate that young, apparently healthy, regular users of e-cigarettes exhibit significantly reduced cardiorespiratory fitness, a marker of cardiovascular health and a predictor of all-cause mortality. We also identified that the young users of e-cigarettes present with lower chronotropic response and impaired skeletal muscle oxygen utilization during exercise.
Assuntos
Aptidão Cardiorrespiratória , Sistemas Eletrônicos de Liberação de Nicotina , Consumo de Oxigênio , Humanos , Aptidão Cardiorrespiratória/fisiologia , Masculino , Feminino , Adulto , Adulto Jovem , Consumo de Oxigênio/fisiologia , Teste de Esforço/métodos , Vaping/efeitos adversos , Exercício Físico/fisiologia , Frequência Cardíaca/fisiologia , Frequência Cardíaca/efeitos dos fármacosRESUMO
Nicotine flux, the rate of electronic nicotine delivery system (ENDS) nicotine emission, is important in determining ENDS abuse liability. However, flux does not account for user behavior, including puff duration. Along with nicotine flux, puff duration limits the dose of nicotine that can be inhaled. Controlling both flux and puff duration allows regulators to constrain nicotine dose effectively. This study examined the effects of differing ENDS nicotine fluxes (by manipulating liquid nicotine concentration and holding device power constant), with user puff duration limited to 2 s. Participants (N = 32) completed four sessions, each session differing by nicotine flux (no flux, low flux, cigarettelike flux, and high flux conditions). Participants completed two ENDS use bouts in each session while puff duration was limited to 2 s. Plasma nicotine concentration, heart rate, and subjective effects were measured. At higher flux, higher plasma nicotine concentration and higher heart rate were observed. Moreover, higher fluxes decreased ratings of craving and urge to use nicotine and increased positive subjective effects, such as calmness. This study demonstrates that by manipulating nicotine flux and limiting puff duration, nicotine dose can be controlled. Subsequent research should demonstrate the effects of manipulating puff duration systematically. Results underscore the importance of targeting both flux and puff duration for ENDS regulation, intended to reduce abuse liability while maintaining the potential to facilitate transitions from cigarettes to ENDS. (PsycInfo Database Record (c) 2024 APA, all rights reserved).
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Frequência Cardíaca , Nicotina , Humanos , Nicotina/administração & dosagem , Nicotina/sangue , Masculino , Adulto , Feminino , Adulto Jovem , Frequência Cardíaca/efeitos dos fármacos , Fissura/efeitos dos fármacos , Vaping , Fatores de TempoRESUMO
Despite the popularity of electronic cigarettes (ECIGs), limited research has examined the role of sweeteners, independent of other flavors, in shaping ECIG human abuse potential (HAP). This study examined the effects of sucralose and nicotine in unflavored ECIG liquid solutions to provide a basic understanding of the effects of sweeteners on ECIG HAP compared to combustible cigarettes. Individuals who smoked cigarettes daily (N = 14) completed five within-subject, Latin-square ordered study sessions that differed by product used: (a) own-brand combustible cigarettes (OB), (b) 0 mg/mL nicotine, unsweetened liquid, (c) 0 mg/mL nicotine, sucralose-sweetened liquid, (d) 15 mg/mL nicotine, unsweetened liquid, and (e) 15 mg/mL nicotine, sucralose-sweetened liquid. Participants completed subjective questionnaires and behavioral tasks following a 10-puff directed use bout during which puff topography was measured, and blood was sampled for later measurement of plasma nicotine concentration. On average, the OB condition had a greater increase in plasma nicotine concentration and produced more pronounced subjective effects compared to the ECIG conditions. The 15 mg/mL nicotine ECIGs delivered significantly more nicotine and produced greater drug effects and reductions in tobacco abstinence symptoms than the 0 mg/mL nicotine ECIGs. Sucralose-containing solutions increased ECIG product appeal, puff duration, and puff volume during the 10-puff directed bout. Findings revealed greater HAP for OB cigarettes relative to all ECIGs tested and suggest that adding sucralose and nicotine elevates ECIG HAP via different mechanisms; sucralose appears to influence HAP through product appeal, while nicotine influences HAP through drug effects and tobacco/nicotine abstinence symptom suppression. (PsycInfo Database Record (c) 2024 APA, all rights reserved).
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Nicotina , Sacarose , Edulcorantes , Humanos , Masculino , Feminino , Adulto , Sacarose/análogos & derivados , Sacarose/administração & dosagem , Nicotina/sangue , Nicotina/administração & dosagem , Adulto Jovem , Tabagismo , Pessoa de Meia-Idade , Fumar CigarrosRESUMO
INTRODUCTION: Policies limiting electronic cigarette (ECIG) device and liquid characteristics have been considered to prevent dependence potential and youth product appeal. "Open-system" ECIGs allow people to adjust device and liquid characteristics, which may undermine these policies. This study examined anticipated reactions to a policy prohibiting the sale of open-system ECIG devices in the United States using concept mapping. METHODS: In 2020, adults who reported ECIG use in the past 30 days (nâ =â 70; 45.1% women; mean ageâ =â 33.0, SDâ =â 10.6) recruited from a research registry of individuals from across the United States provided statements into a shared list that completed a prompt: "If open-system vaping devices were no longer sold in the US and only closed-system vaping devices were available, what is a specific reaction or response you would have?" at a study website. Participants rated statements (1-7) on how true the statements were for them. Multidimensional scaling and hierarchical cluster analyses were used to identify thematic clusters. Mean ratings of statements were calculated and compared based on the type of ECIG used and current cigarette smoking status. RESULTS: Participants generated 85 unique statements. The analysis identified eight themes that were organized into two broad groups. The first group of five clusters described behavioral responses to the hypothetical policy (Loopholes, Switch to Closed-System ECIGs, Legal Approaches to Use Open-System ECIGs, ECIG Use Cessation, Switch to non-ECIG Products). The second group of three clusters described psychological responses to the hypothetical policy (Closed-System ECIG Cons, Psychological Responses, Policy Outcome Concerns). CONCLUSIONS: While a ban on open-system ECIG devices may have positive impacts on public health, policy loopholes, and consumer behaviors may undermine the policy. Efforts to support policy enforcement could increase policy effectiveness. IMPLICATIONS: Open-system electronic cigarettes (ECIGs) that allow people who use ECIGs to modify ECIG device and liquid characteristics may limit the effectiveness of policies that establish product standards which attempt to limit nicotine delivery and flavor content in ECIG liquids. This study identified predicted reactions to a hypothetical policy prohibiting the sale of open-system ECIGs in the United States. Results suggest that people who use ECIGs may view a policy prohibiting open-system ECIGs unfavorably, but would be willing to use closed-system ECIGs. However, many ECIG users may attempt to find loopholes in the policy or alternative sources to purchase open-system ECIGs if open-systems were banned. Future research should identify strategies for tobacco regulatory policy enforcement to increase effectiveness.
RESUMO
BACKGROUND: Electronic (e-) cigarettes are increasingly popular tobacco products on the US market. Traditional tobacco products are known to cause vascular dysfunction, one of the earliest indicators of cardiovascular disease (CVD) development. However, little is known about the effect of regular e-cigarette use on vascular function. The purpose of this study was to investigate the impact of regular e-cigarette use on vascular function and cardiovascular health in young, healthy adults. METHODS: Twenty-one regular users of e-cigarettes (ECU) and twenty-one demographically matched non-users (NU) completed this study. Vascular health was assessed in the cutaneous microcirculation through different reactivity tests to evaluate overall functionality, endothelium-dependent vasodilation (EDD), and endothelium-independent vasodilation (EID). Macrovascular function was assessed using flow-mediated dilation (FMD). RESULTS: Our results suggest that regular users of e-cigarettes present with premature microvascular impairment when compared to non-users. Specifically, they exhibit lower hyperemic (p = 0.003), thermal (p = 0.010), and EDD (p = 0.004) responses. No differences in EID between the groups were identified. We also identified that individuals who use e-cigarettes for longer than 3 years also present with systemic manifestations, as observed by significantly reduced macrovascular (p = 0.002) and microvascular (p ≤ 0.044) function. CONCLUSIONS: Our novel data suggests that young, apparently healthy, regular users of e-cigarettes present with premature vascular dysfunction in the microcirculation when compared to non-users. We have also identified systemic vascular dysfunction affecting both the micro and macrovasculature in those young individuals who used e-cigarettes for longer than 3 years. Taken together, these findings associate regular e-cigarette use with premature vascular dysfunctions and adverse cardiovascular outcomes.
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Humanos , Adulto Jovem , Vasodilatação/fisiologia , Endotélio VascularRESUMO
INTRODUCTION: Electronic cigarette (EC) use has increased rapidly in the last decade, especially among youth. Regulating nicotine delivery from ECs could help curb youth uptake and leverage EC use in harm reduction yet is complicated by varying device and liquid variables that affect nicotine delivery. Nicotine flux, the nicotine emission rate, is a parameter that incorporates these variables and focuses on the performance rather than the design of an EC. Nicotine flux therefore could be a powerful regulatory tool if it is shown empirically to predict nicotine delivery and subjective effects related to dependence. METHODS AND ANALYSIS: This project consists of two complementary clinical trials. In Trial I, we will examine the relationship between nicotine flux and the rate and dose of nicotine delivery from ECs, hence, impacting abuse liability. It will also examine the extent to which this relationship is mediated by nicotine form (i.e., freebase versus protonated). At Yale School of Medicine (YSM), study participants will puff EC devices under conditions that differ by flux and form, while arterial blood is sampled in high time resolution. In Trial II, we will assess the relationship between nicotine flux, form, and subjective effects. At the American University of Beirut (AUB), participants will use EC devices with varying nicotine fluxes and forms, while dependency measures, such as the urge to use ECs, nicotine craving, and withdrawal symptoms, will be assessed. We will also monitor puffing intensity and real-time exposure to toxicants. ETHICS AND DISSEMINATION: The protocol of Trial I and Trial II was approved by YSM and AUB IRBs, respectively. We will disseminate study results through peer-reviewed publications and conference presentations. TRIAL REGISTRATION: NCT05706701 for Trial I and NCT05430334 for Trial II.
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Nicotina , Adolescente , Humanos , Transporte Biológico , Fissura , Estudos Cross-OverRESUMO
Electronic cigarettes (e-cigs), originally intended to be used as cigarette substitutes, have evolved into discreet devices for consuming drugs other than nicotine (DOTNs). Presented are the results of an exploratory survey in which information regarding demographics, e-cig device type, DOTN use, frequency and context of use was collected. The average reported age of respondents was 27.4 years of age (SD = 12.0), and respondents predominantly identified as male (73%). Vape pens (disposable or refillable) were the most reported device across all DOTN classes. Cannabinoids were the most reported class of DOTN used, for both lifetime and past 30-day use. Other DOTNs reported included herbal supplements, amphetamines, caffeine, kratom, vitamins, opiates, DMT, fentanyl, and ketamine. Combinations of DOTNs used in e-cigs and trends in poly-substance use were reported. The most commonly reported context was vaping alone, followed by with friends, at home, and at social events; less commonly reported contexts included when driving, at work, and at school. Results from this study are useful for developing future national surveys to consider a comprehensive substance use-focused strategy that includes vaping, building awareness of DOTN e-cig use, and highlighting public safety issues in driving impairment, crime scene investigations, and death investigations.
RESUMO
Legal professionals and others have suggested that vaping electronic cigarettes (e-cigs) prior to or during ethanol breath testing may produce false positives. Preliminary breath tests (PBTs) and evidentiary breath tests (EBTs) measure ethanol in exhaled breath and standardized field sobriety tests (SFSTs) are used to assess impairment. Ethanol has been identified in e-cig liquids (e-liquids). Presented are a series of experiments designed to determine the mechanics of vaping ethanol using an e-cig and the effects of vaping ethanol on the SFSTs and breath tests used by law enforcement officers (LEO). Twelve participants (five females, age: 21-32 and seven males, age: 21-55), vaped either one or ten puffs of an e-liquid (0% or 20% ethanol). LEOs assessed impairment using SFSTs (12 and 42 min), PBTs (<1, 27, 32, 37 and 57 min) and EBTs (2, 29, 34, 39 and 59 min) post-vaping. A self-assessment test was administered post-vaping (22 and 52 min). Baseline responses for all measures were collected prior to vaping. Results demonstrated that ethanol in the e-liquids was aerosolized by e-cigs and produced particles that could reach the deep lung tissue based on mean-mass diameter. Ethanol was detected by PBT <3 min after participants vaped one (0.007-0.030 g/210 L) or ten puffs (013-0.074 g/210 L) of a 20% ethanol e-liquid. Ethanol was not detected by PBT at any subsequent time point. Ethanol was not detected by the EBT under any condition. Impairment was not indicated by the SFST. Some subjective effects were reported, but few statistically significant differences between conditions were indicated. A wait period prior to ethanol breath testing is not always mandated, depending on jurisdiction, or observed in all applications, such as workplace testing. The results demonstrate that a wait period must be employed to prevent vaping-related false-positive breath ethanol results.
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Vaping , Masculino , Feminino , Humanos , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Pulmão , Testes RespiratóriosRESUMO
INTRODUCTION: The prevalence of flavor use in Electronic Nicotine Delivery Systems (ENDS) has been assessed in numerous studies, but limited research has focused on flavor use trends and maintenance of flavor preference over time. This study investigated the general trends and maintenance of ENDS flavor use for youth (aged 12-17 years), young adults (aged 18-24 years), and older adults (aged ≥25 years) between 2014 and 2019. METHODS: Population Assessment of Tobacco and Health (PATH) Study Wave 2 (2014-2015), Wave 3 (2015-2016), Wave 4 (2016-2017), and Wave 5 (2018-2019) youth and adult data were used. Cross-sectional flavor use prevalence (trends) and flavor maintenance (using the same flavor category in at least three consecutive waves) were assessed. RESULTS: The most reported primary flavor category was fruit among all age groups in all waves. Candy/desserts in waves two, three, four, and menthol/mint in wave five were the second most reported flavor in all age groups. The highest increase was observed for menthol/mint use among youth between wave two (21.9%) and five (58.1%) (OR=5.33; 95% CI: 3.58-7.96). Overall, 37.6% of fruit flavor users, 25.3% of candy/desserts users, 32.0% of menthol/mint users, and 33.4% of tobacco flavor users, maintained use of the same flavor in at least three consecutive waves. CONCLUSIONS: Fruit flavor had the highest percentages of use and maintenance between 2014 and 2019. While the maintenance of fruit and candy/desserts flavors were higher among youth, adults had substantially higher maintenance percentages for menthol/mint and tobacco flavor. There was a substantial increase in menthol/mint use in wave five among youth, which may affect ENDS flavor maintenance patterns in the future. Understanding maintenance of flavors over time can inform regulation of ENDS flavors.
RESUMO
Background: Regulations limiting nicotine in electronic cigarettes (e-cigarettes) have been proposed or implemented. Little is known about e-cigarette users' reactions to reducing e-cigarette liquid nicotine concentration. Methods: We used concept mapping to describe e-cigarette users' reactions to a 50% reduction in the nicotine concentration of their e-cigarette liquids. In 2019, current e-cigarette users who used e-cigarette liquid with greater than 0 mg/ml nicotine concentration completed an online study. Participants (n = 71, mean age = 34.9 (SD = 11.0), 50.7% women), brainstormed statements completing a prompt: "If the e-liquid that I use now in my e-cigarette/vaping device was only available in half the nicotine concentration or amount that I use now, a specific action I would take or a specific reaction I would have is ", Participants then sorted a final list of 67 statements into piles of similar content and rated statements on how true the statements would be for them. Multidimensional scaling and hierarchical cluster analyses identified thematic clusters. Results: Eight clusters were identified: (1) Replacement Product Seeking, (2) Mental Preparations and Expectations, (3) Use the New Liquid, (4) Information Seeking, (5) Compensation Behaviors, (6) Opportunity for E-Cigarette Reduction, (7) Physical and Psychological Effects, and (8) Replacement with non-E-Cigarette Products and Behaviors. Cluster ratings suggested many participants would search for other e-cigarette products/liquids to replace their current liquids, but using other tobacco products (e.g., cigarettes) may be less likely. Conclusions: If nicotine concentrations were decreased in e-cigarette liquids, e-cigarette users may attempt to purchase different e-cigarette products or modify their products to achieve desired effects.
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Produtos do Tabaco , Vaping , Humanos , Feminino , Adulto , Masculino , Nicotina , FumantesRESUMO
INTRODUCTION: Vuse Solo is the first electronic nicotine delivery system (ENDS) authorised by the US Food and Drug Administration for marketing in the USA. Salient features of the Vuse Solo product such as nicotine form, draw resistance, power regulation and electrical characteristics have not been reported previously, and few studies have examined the nicotine and other toxicant emissions of this product. We investigated the design characteristics and toxicant emissions of the Solo as well as Alto, another Vuse product with a greater market share than Solo. METHODS: Total/freebase nicotine, propylene glycol to vegetable glycerin ratio, carbonyl compounds (CC) and reactive oxygen species (ROS) were quantified by gas chromatography, high-performance liquid chromatography and fluorescence from aerosol emissions generated in 15 puffs of 4 s duration. The electric power control system was also analysed. RESULTS: The average power delivered was 2.1 W and 3.9 W for Solo and Alto; neither system was temperature-controlled. Vuse Solo and Alto, respectively, emitted nicotine at a rate of 38 µg/s and 115 µg/s, predominantly in the protonated form (>90%). Alto's ROS yield was similar to a combustible cigarette and one order of magnitude greater than that of Solo. Total carbonyls from both products were two orders of magnitude lower than combustible cigarettes. CONCLUSION: Vuse Solo is an above-Ohm ENDS that emits approximately one-third the nicotine flux of a Marlboro Red cigarette (129 µg/s) and considerably lower CC and ROS yields than a combustible cigarette. With its higher power, the nicotine flux and ROS yield from Alto are similar to Marlboro Red levels; Alto may thus present greater abuse liability than the lower sales-volume Solo.
RESUMO
Menthol cigarette use is disproportionately higher among sexual- and gender-minoritized (SGM; 36%) individuals compared to cisgender, heterosexual (29%), individuals. The FDA has announced intentions to ban menthol in cigarettes, citing these use and health disparities as partial motivation. This study identified potential outcomes of a menthol cigarette ban among SGM individuals who smoke menthol cigarettes (N = 72). Potential outcomes were identified via concept mapping using the prompt: "If menthol in cigarettes was banned, a specific action I would take related to my tobacco use is " Participants generated 82 response statements, sorted them, and rated them on personal relevance. Eight thematic clusters were identified: (1) Thoughtful Consideration of the Ban, (2) Negative Reactions to the Ban, (3) Positive Aspects of the Ban, (4) Strategies to Reduce Cravings, (5) Intent to Quit and Cessation Strategies, (6) Support-Seeking and Engagement in Positive Behaviors, (7) Strategies to Maintain Menthol-Flavored Product Use, and (8) Substance Use Alternatives to Menthol Cigarettes. Cluster differences based on sociodemographic factors, smoking behavior, and quitting interest were identified. Results provide insight into potential responses to a menthol cigarette ban and can contribute to public health prevention and intervention efforts, messaging campaigns, and support services for SGM people who smoke menthol cigarettes, specifically.
Assuntos
Abandono do Hábito de Fumar , Produtos do Tabaco , Humanos , Mentol , Abandono do Hábito de Fumar/métodos , Comportamento Sexual , Identidade de GêneroRESUMO
BACKGROUND: In total, 3.2% of American adults report using e-cigarettes every day or some days. The Vaping and Patterns of E-cigarette Use Research (VAPER) Study is a web-based longitudinal survey designed to observe patterns in device and liquid use that suggest the benefits and unintended consequences of potential e-cigarette regulations. The heterogeneity of the e-cigarette devices and liquids on the market, the customizability of the devices and liquids, and the lack of standardized reporting requirements result in unique measurement challenges. Furthermore, bots and survey takers who submit falsified responses are threats to data integrity that require mitigation strategies. OBJECTIVE: This paper aims to describe the protocols for 3 waves of the VAPER Study and discuss recruitment and data processing experiences and lessons learned, including the benefits and limitations of bot- and fraudulent survey taker-related strategies. METHODS: American adults (aged ≥21 years) who use e-cigarettes ≥5 days per week are recruited from up to 404 Craigslist catchment areas covering all 50 states. The questionnaire measures and skip logic are designed to accommodate marketplace heterogeneity and user customization (eg, different skip logic pathways for different device types and customizations). To reduce reliance on self-report data, we also require participants to submit a photo of their device. All data are collected using REDCap (Research Electronic Data Capture; Vanderbilt University). Incentives are US $10 Amazon gift codes delivered by mail to new participants and electronically to returning participants. Those lost to follow-up are replaced. Several strategies are applied to maximize the odds that participants who receive incentives are not bots and are likely to possess an e-cigarette (eg, required identity check and photo of a device). RESULTS: In total, 3 waves of data were collected between 2020 and 2021 (wave 1: n=1209; wave 2: n=1218; wave 3: n=1254). Retention from waves 1 to 2 was 51.94% (628/1209), and 37.55% (454/1209) of the wave 1 sample completed all 3 waves. These data were mostly generalizable to daily e-cigarette users in the United States, and poststratification weights were generated for future analyses. Our data offer a detailed examination of users' device features and specifications, liquid characteristics, and key behaviors, which can provide more insights into the benefits and unintended consequences of potential regulations. CONCLUSIONS: Relative to existing e-cigarette cohort studies, this study methodology has some advantages, including efficient recruitment of a lower-prevalence population and collection of detailed data relevant to tobacco regulatory science (eg, device wattage). The web-based nature of the study requires several bot- and fraudulent survey taker-related risk-mitigation strategies, which can be time-intensive. When these risks are addressed, web-based cohort studies can be successful. We will continue to explore methods for maximizing recruitment efficiency, data quality, and participant retention in subsequent waves. INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/38732.
RESUMO
SIGNIFICANCE: IQOS is a heated tobacco product that has been widely advertised by Philip Morris International (PMI) as a reduced-exposure product compared with cigarettes. Reduced exposure results from reduced emission of toxicants which could be influenced by product constituents and user behaviour. This study aims to assess the influence of user behaviour, including device cleaning and puffing parameters, on toxicant emissions from IQOS. METHODS: IQOS aerosols were generated by a smoking machine using the combination of two cleaning protocols (after 1 stick vs 20 sticks) and five puffing regimes (including standard cigarette puffing regimes and IQOS-tailored regimes). The generated aerosols were analysed by targeted methods for phenol and carbonyl quantification, and by chemical screening for the identification of unknown compounds. RESULTS: Puffing parameters significantly affected phenol and carbonyl emissions while device cleaning had no effect. Harsher puffing conditions like more, longer, and larger puffs yielded higher levels for most toxicant emissions. Comparing the obtained data with data reported by PMI on 50 cigarette brands smoked under different puffing regimes showed various trends for phenol and carbonyl emissions, with IQOS emissions sometimes higher than cigarettes. Also, the chemical screening resulted in the tentative identification of ~100 compounds in the IQOS aerosols (most of limited toxicity data). CONCLUSION: This study showed that puffing parameters, but not device cleaning, have significant effects on carbonyl, phenol and other emissions. Data analysis highlighted the importance of comparing IQOS emissions with an array of commercial cigarettes tested under different puffing regimes before accepting reduced exposure claims.
RESUMO
BACKGROUND: Research is inconclusive on the effectiveness of electronic nicotine delivery systems (ENDS) as cigarette cessation aids compared with nicotine replacement therapy (NRT) or non-NRT medication. This study compared the cigarette cessation rates for ENDS, NRT and non-NRT medication. METHOD: Population Assessment of Tobacco and Health Study wave 3 cigarette-only users who used ENDS, NRT or non-NRT medication (varenicline and bupropion) to quit smoking between wave 3 and 4 were included. 'Cessation' was defined as being a former cigarette smoker in wave 4. χ2, logistic regression, and a sensitivity analysis with Bayes factor assessed the association between quitting smoking and method used. RESULTS: Among 6794 cigarette-only users, 532 used ENDS (n=75), NRT (n=289), non-NRT medication (n=68), or a combination of NRT and non-NRT medication (n=100) to quit smoking between wave 3 and 4. The percentages of quitting smoking among those who used ENDS, NRT, non-NRT medication, and a combination of NRT and non-NRT medication were 16.2% (n=14), 16.1% (n=47), 17.7% (n=13), and 14.8% (n=12), respectively (p=0.97). None of the cigarette-only users who used ENDS to quit smoking became ENDS-only users in wave 4; 37.6% became dual users of ENDS and cigarettes. CONCLUSION: No differences were found when cessation rates of ENDS, NRT or non-NRT medication were compared. Given uncertainty about the long-term health effect of ENDS and the likelihood of becoming dual users, people who smoke and need assistance quitting should be encouraged to use current Food and Drug Administration-approved cessation methods until more effective methods are developed.
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Abandono do Hábito de Fumar , Produtos do Tabaco , Humanos , Adulto , Abandono do Hábito de Fumar/métodos , Teorema de Bayes , Dispositivos para o Abandono do Uso de TabacoRESUMO
Electronic nicotine delivery systems (ENDSs) produce an aerosol by heating a liquid that often contains nicotine. The nicotine can be protonated that may make the aerosol easier to inhale than freebase nicotine. This study's purpose is to determine, in cigarette smokers and ENDS users, the effects of three concentrations of protonated nicotine aerosolized at two different power settings. Forty-five participants (22 cigarette smokers and 23 ENDS users) completed some or all of six sessions that varied by liquid nicotine concentration (10, 15, or 30 mg/ml protonated nicotine) and device power (15 or 30 W). Participants took 10 puffs from each product and then used each product for 90 min ad libitum. Plasma nicotine concentration, subjective effects, and puff topography were measured. Results showed increases in plasma nicotine concentration in all conditions, with greater plasma nicotine increases in higher watt, higher nicotine concentration conditions, as well as greater nicotine delivery for ENDS users compared to cigarette smokers. For puff topography, puff duration and volume decreased as nicotine concentration and power increased, and ENDS users took longer and larger puffs than cigarette smokers. Participants rated the higher watt, higher nicotine concentration conditions as harsher and with more throat hit. Overall, these results suggest that device characteristics and liquid constituents interact to influence users' plasma nicotine delivery and should be considered together when regulating ENDS. (PsycInfo Database Record (c) 2023 APA, all rights reserved).
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Produtos do Tabaco , Humanos , Nicotina , Fumar , FumantesRESUMO
INTRODUCTION: How nicotine dependence will be affected when current smokers initiate electronic cigarette (e-cigarette) use to reduce cigarette smoking is unknown. This study evaluated cigarette, e-cigarette, and total nicotine dependence more than 6 months among smokers reducing cigarette consumption by replacing with e-cigarettes. AIMS AND METHODS: Adult cigarette smokers were randomized to one of four conditions (36 mg/ml e-cigarette, 8 mg/ml e-cigarette, 0 mg/ml e-cigarette, or cigarette-substitute [CS] [provided at no cost]) and instructed to reduce their cigarette smoking by 75% at 1 month. Participants completed follow-up at 1, 3, and 6 months. The Penn State Nicotine Dependence Index (PSNDI) measured dependence on cigarettes (PSCDI) and e-cigarettes (PSECDI). Urine cotinine measured total nicotine exposure. Linear mixed effects models for each outcome were conducted and included interaction terms between visit and condition. RESULTS: Participants (n = 520) were 58.8% female, 67.3% White, and 48.0 years old. At baseline, the median number of cigarettes smoked per day was 17.3 and the mean PSCDI score was 13.4, with no significant differences between conditions. Participants in the e-cigarette conditions reported significantly lower PSCDI scores, compared with baseline, and with the CS condition at all follow-up visits. Those in the 36 mg/ml e-cigarette condition reported greater PSECDI scores at 6 months, compared with baseline and the 0 mg/ml and 8 mg/ml conditions. At all follow-up visits, there were no differences in total nicotine exposure compared to baseline, nor between any conditions. CONCLUSIONS: E-cigarette use was associated with reduced cigarette dependence, compared to the CS, without significant increases in total nicotine exposure. IMPLICATIONS: Initiation of electronic cigarette use while continuing to smoke could potentially increase nicotine dependence. In this randomized trial aimed at helping smokers to reduce their cigarette intake, we found that use of an e-cigarette was associated with a reduction in cigarette dependence and an increase in e-cigarette dependence (in the condition with the highest nicotine concentration only), with no long term increase in total nicotine dependence or nicotine exposure.
Assuntos
Fumar Cigarros , Sistemas Eletrônicos de Liberação de Nicotina , Abandono do Hábito de Fumar , Produtos do Tabaco , Tabagismo , Adulto , Humanos , Feminino , Masculino , Tabagismo/prevenção & controle , Nicotina , Fumantes , NicotianaRESUMO
BackgroundRegulations have been proposed to limit e-cigarette flavours, but limited research has examined potential impacts of such policies. This study examined adult e-cigarette users' reactions to a hypothetical e-cigarette flavour ban. METHODS: In 2019, a convenience sample of current e-cigarette users in the USA (n=81, 53.1% women, mean age=37.6, 59.3% dual users of cigarettes) completed an online concept mapping study. Participants provided statements describing anticipated reactions to a hypothetical policy in which only tobacco, menthol or unflavoured e-cigarettes were available for purchase. Seventy-one unique statements were generated. Participants sorted statements into thematic groups and rated statements on how likely they would be to have each reaction. Multidimensional scaling was used to identify thematic clusters of statements. RESULTS: Twelve clusters were identified: negative reaction, take action against flavour limitation, youth prevention effectiveness perception, tolerance, acceptance, willingness to try new flavours, maintain vaping, reduce vaping, new flavours as vaping cessation transition, alternative sources for banned flavours, do-it-yourself mixing behaviours and alternative tobacco products. The highest rated cluster (negative reaction) described being angry or upset that flavours were banned, while the lowest rated clusters related to quitting/reducing e-cigarette use or switching to other tobacco products. Non-tobacco or non-menthol/mint flavoured e-cigarette users had higher ratings for clusters describing negative sentiment for the hypothetical policy. CONCLUSIONS: Some e-cigarette users may dislike an e-cigarette flavour ban; however, some e-cigarette users would likely be willing to use tobacco, menthol or unflavoured e-cigarette liquids with lower likelihood of quitting vaping or switching to other tobacco products.
Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Produtos do Tabaco , Vaping , Adulto , Adolescente , Feminino , Humanos , Masculino , Aromatizantes , Fumantes , MentolRESUMO
INTRODUCTION: The combination of electronic nicotine delivery systems (ENDS) device and liquid characteristics affect user nicotine and toxicant exposure, however population-level national survey studies have not reported device and liquid features jointly nor in detail. We examined combinations of characteristics of devices and liquids used by adult ENDS users. METHODS: U.S. adults (21+) using ENDS at least five days/week (n = 1,179) completed an online survey in 2020 and uploaded photos of their most used device and liquid. Device/liquid combinations were analyzed to determine and describe the most common pairings. Data were weighted to the U.S. population of adult daily ENDS users. RESULTS: Five device/liquid combinations accounted for 87 % of those reported. The most prevalent combination, reported by 36.2 %, was re-useable devices with adjustable settings and a tank refilled with a free-base nicotine liquid with a median nicotine concentration of 5.2 mg/mL. The second most frequent combination - re-usable devices with no adjustable settings and a nicotine salt liquid in a disposable pod or cartridge - was reported by 22.8 % and the median nicotine concentration was 49.4 mg/mL. Wattage, voltage and resistance varied across device/liquid combination. Overall, 66.5 % refilled their device's tank or pod and 64.2 % had the ability to manipulate device characteristics (power, airflow, and/or coil). CONCLUSIONS: Analyzing ENDS device/liquid combinations rather than each separately can allow researchers to better evaluate relationships between use and key outcomes, such as quitting cigarettes and abuse liability. Additional research may reveal whether certain combinations are more effective at helping smokers quit and which device/liquid combinations should remain on the market.