Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Astrobiology ; 23(12): 1337-1347, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-38079231

RESUMO

The highly compact Linear Ion Trap Mass Spectrometer (LITMS), developed at NASA Goddard Space Flight Center, combines Mars-ambient laser desorption-mass spectrometry (LD-MS) and pyrolysis-gas chromatography-mass spectrometry (GC-MS) through a single, miniaturized linear ion trap mass analyzer. The LITMS instrument is based on the Mars Organic Molecule Analyser (MOMA) investigation developed for the European Space Agency's ExoMars Rover Mission with further enhanced analytical features such as dual polarity ion detection and a dual frequency RF (radio frequency) power supply allowing for an increased mass range. The LITMS brassboard prototype underwent an extensive repackaging effort to produce a highly compact system for terrestrial field testing, allowing for molecular sample analysis in rugged planetary analog environments outside the laboratory. The LITMS instrument was successfully field tested in the Mars analog environment of the Atacama Desert in 2019 as part of the Atacama Rover Astrobiology Drilling Studies (ARADS) project, providing the first in situ planetary analog analysis for a high-fidelity, flight-like ion trap mass spectrometer. LITMS continued to serve as a laboratory tool for continued analysis of natural Atacama samples provided by the subsequent 2019 ARADS final field campaign.


Assuntos
Marte , Voo Espacial , Exobiologia/métodos , Espectrometria de Massas , Cromatografia Gasosa-Espectrometria de Massas/métodos
2.
Sci Rep ; 9(1): 5370, 2019 03 29.
Artigo em Inglês | MEDLINE | ID: mdl-30926841

RESUMO

The search for life beyond Earth is a key motivator in space exploration. Informational polymers, like DNA and RNA, are key biosignatures for life as we know it. The MinION is a miniature DNA sequencer based on versatile nanopore technology that could be implemented on future planetary missions. A critical unanswered question is whether the MinION and its protein-based nanopores can withstand increased radiation exposure outside Earth's shielding magnetic field. We evaluated the effects of ionizing radiation on the MinION platform - including flow cells, reagents, and hardware - and discovered limited performance loss when exposed to ionizing doses comparable to a mission to Mars. Targets with harsher radiation environments, like Europa, would require improved radiation resistance via additional shielding or design refinements.


Assuntos
Meio Ambiente Extraterreno , Vida , Nanoporos , Tolerância a Radiação , Júpiter , Marte , Análise de Sequência de DNA/instrumentação
3.
Astrobiology ; 17(12): 1203-1218, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29227156

RESUMO

The search for life and habitable environments on other Solar System bodies is a major motivator for planetary exploration. Due to the difficulty and significance of detecting extant or extinct extraterrestrial life in situ, several independent measurements from multiple instrument techniques will bolster the community's confidence in making any such claim. We demonstrate the detection of subsurface biosignatures using a suite of instrument techniques including IR reflectance spectroscopy, laser-induced breakdown spectroscopy, and scanning electron microscopy/energy dispersive X-ray spectroscopy. We focus our measurements on subterranean calcium carbonate field samples, whose biosignatures are analogous to those that might be expected on some high-interest astrobiology targets. In this work, we discuss the feasibility and advantages of using each of the aforementioned instrument techniques for the in situ search for biosignatures and present results on the autonomous characterization of biosignatures using multivariate statistical analysis techniques. Key Words: Biosignature suites-Caves-Mars-Life detection. Astrobiology 17, 1203-1218.


Assuntos
Carbonato de Cálcio/análise , Exobiologia/instrumentação , Meio Ambiente Extraterreno , Vida , Análise Espectral/instrumentação , Carbonato de Cálcio/química , Cavernas , Estudos de Viabilidade , Análise Espectral/métodos
4.
Analyst ; 142(12): 2109-2117, 2017 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-28548668

RESUMO

A limitation of conventional quadrupole ion trap scan modes which use rf amplitude control for mass scanning is that, in order to detect a subset of an ion population, the rest of the ion population must also be interrogated. That is, ions cannot be detected out of order; they must be detected in order of either increasing or decreasing mass-to-charge (m/z). However, an ion trap operated in the ac frequency scan mode, where the rf amplitude is kept constant and instead the ac frequency is used for mass-selective operations, has no such limitation because any variation in the ac frequency affects only the subset of ions whose secular frequencies match the perturbation frequency. Hence, an ion trap operated in the ac frequency scan mode can perform any arbitrary mass scan, as well as a sequence of scans, using a single ion injection; we demonstrate both capabilities here. Combining these two capabilities, we demonstrate the acquisition of a full mass spectrum, a product ion spectrum, and a second generation product ion spectrum using a single ion injection event. We further demonstrate a "segmented scan" in which different mass ranges are interrogated at different rf amplitudes in order to improve resolution over a portion of the mass range, and a "periodic scan" in which ions are continuously introduced into the ion trap to achieve a nearly 100% duty cycle. These unique scan modes, along with other characteristics of ac frequency scanning, are particularly appropriate for miniature ion trap mass spectrometers. Hence, implementation of ac frequency scanning on a prototype of the Mars Organic Molecule Analyzer mass spectrometer is also described.

5.
Astrobiology ; 17(6-7): 655-685, 2017 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31067288

RESUMO

The Mars Organic Molecule Analyzer (MOMA) instrument onboard the ESA/Roscosmos ExoMars rover (to launch in July, 2020) will analyze volatile and refractory organic compounds in martian surface and subsurface sediments. In this study, we describe the design, current status of development, and analytical capabilities of the instrument. Data acquired on preliminary MOMA flight-like hardware and experimental setups are also presented, illustrating their contribution to the overall science return of the mission. Key Words: Mars-Mass spectrometry-Life detection-Planetary instrumentation. Astrobiology 17, 655-685.

6.
Int J Mass Spectrom ; 422: 177-187, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33005095

RESUMO

The Mars Organic Molecule Analyzer (MOMA), a dual-source, ion trap-based instrument capable of both pyrolysis-gas chromatography mass spectrometry (pyr/GC-MS) and laser desorption/ionization mass spectrometry (LDI-MS), is the core astrobiology investigation on the ExoMars rover. The MOMA instrument will be the first spaceflight mass analyzer to exploit the LDI technique to detect refractory organic compounds and characterize host mineralogy; this mode of analysis will be conducted at Mars ambient conditions. In order to achieve high performance in the Martian environment while keeping the instrument compact and low power, a number of innovative designs and components have been implemented for MOMA. These include a miniaturized linear ion trap (LIT), a fast actuating aperture valve with ion inlet tube. and a Microelectromechanical System (MEMS) Pirani sensor. Advanced analytical capabilities like Stored Waveform Inverse Fourier Transform (SWIFT) for selected ion ejection and tandem mass spectrometry (MS/MS) are realized in LDI-MS mode, and enable the isolation and enhancement of specific mass ranges and structural analysis, respectively. We report here the technical details of these instrument components as well as system-level analytical capabilities, and we review the applications of this technology to Mars and other high-priority targets of planetary exploration.

7.
Planet Space Sci ; 131: 70-78, 2016 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-32818000

RESUMO

We present a laboratory reproduction of hypervelocity impacts of a carbon containing meteorite on a mineral substance representative of planetary surfaces. The physical conditions of the resulting impact plasma torch provide favorable conditions for abiogenic synthesis of protein amino acids: We identified glycine and alanine, and in smaller quantities serine, in the produced material. Moreover, we observe breaking of alanine mirror symmetry with L excess, which coincides with the bioorganic world. Therefore the selection of L-amino acids for the formation of proteins for living matter could have been the result from plasma processes occurring during the impact meteorites on the surface. This indicates that the plasma torch from meteorite impacts could play an important role in the formation of biomolecular homochirality. Thus, meteorite impacts possibly were the initial stage of this process and promoted conditions for the emergence of a living matter.

8.
Astrobiology ; 15(2): 104-10, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25622133

RESUMO

Evidence from recent Mars missions indicates the presence of perchlorate salts up to 1 wt % level in the near-surface materials. Mixed perchlorates and other oxychlorine species may complicate the detection of organic molecules in bulk martian samples when using pyrolysis techniques. To address this analytical challenge, we report here results of laboratory measurements with laser desorption mass spectrometry, including analyses performed on both commercial and Mars Organic Molecule Analyzer (MOMA) breadboard instruments. We demonstrate that the detection of nonvolatile organics in selected spiked mineral-matrix materials by laser desorption/ionization (LDI) mass spectrometry is not inhibited by the presence of up to 1 wt % perchlorate salt. The organics in the sample are not significantly degraded or combusted in the LDI process, and the parent molecular ion is retained in the mass spectrum. The LDI technique provides distinct potential benefits for the detection of organics in situ on the martian surface and has the potential to aid in the search for signs of life on Mars.


Assuntos
Exobiologia , Espectrometria de Massas , Percloratos/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz , Cálcio/química , Carbonatos/química , Lasers , Magnésio/química , Marte , Compostos Orgânicos/química , Percloratos/química , Compostos Policíclicos/química , Rodaminas/química , Silicatos , Voo Espacial/instrumentação
9.
Rapid Commun Mass Spectrom ; 26(23): 2786-90, 2012 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-23124670

RESUMO

RATIONALE: A miniature time-of-flight mass spectrometer measuring 20 cm in length has been adapted to demonstrate two-step laser desorption/ionization (LDI) in a compact instrument package for enhanced organics detection. Two-step LDI decouples the desorption and ionization processes, relative to traditional LDI, in order to produce low-fragmentation mass spectra of organic analytes. Tuning the UV ionization laser energy would allow control of the degree of fragmentation, which might enable better identification of constituent species. METHODS: A reflectron time-of-flight mass spectrometer prototype was modified to allow a two-laser configuration, with IR (1064 nm) desorption followed by UV (266 nm) postionization. A relatively low ion extraction voltage of 5 kV was applied at the sample inlet. RESULTS: The instrument capabilities and performance were demonstrated with analysis of a model polycyclic aromatic hydrocarbon, representing a class of compounds important to the fields of Earth and planetary science. Two-step laser mass spectrometry (L2MS) analysis of a model PAH, pyrene, was demonstrated, including molecular ion identification and the onset of tunable fragmentation as a function of ionizing laser energy. Mass resolution m/Δm = 380 at full width at half-maximum was achieved for gas-phase postionization of desorbed neutrals in this highly compact mass analyzer. CONCLUSIONS: Achieving L2MS in a highly miniaturized instrument enables a powerful approach to the detection and characterization of aromatic organics in remote terrestrial and planetary applications. Tunable detection of molecular and fragment ions with high mass resolution, diagnostic of molecular structure, is possible on such a compact L2MS instrument. The selectivity of L2MS against low-mass inorganic salt interferences is a key advantage when working with unprocessed, natural samples, and a mechanism for the observed selectivity is proposed.


Assuntos
Espectrometria de Massas/instrumentação , Pirenos/química , Desenho de Equipamento , Lasers , Voo Espacial/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA