Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Mem Inst Oswaldo Cruz ; 118: e220202, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36946838

RESUMO

BACKGROUND: The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES: The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS: Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS: The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS: The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.


Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , COVID-19/diagnóstico , Teste para COVID-19 , Bioensaio , Mapeamento Cromossômico
2.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1422150

RESUMO

BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.

3.
Mem. Inst. Oswaldo Cruz ; 118: e220202, 2023. tab, graf
Artigo em Inglês | LILACS-Express | LILACS | ID: biblio-1430842

RESUMO

BACKGROUND The prevalence of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern (VOCs) has changed unevenly over time around the world. Although whole genome sequencing is the gold standard for virus characterisation, the discovery of alpha VOC causing spike gene target failure (SGTF) result, when tested using an reverse transcription real-time polymerase chain reaction (RT-qPCR) assay, has provided a simple tool for tracking the frequencies of variants. OBJECTIVES The aim of this study was to investigate if a multiplex RT-qPCR assay (BioM 4Plex VOC) could be used to detect SARS-CoV-2 and to perform a VOC screening test in a single reaction tube. Here, we present the multicentre study evaluating this assay. METHODS Twelve laboratories have participated in the multicentre study. The BioM 4Plex VOC was distributed to them with detailed instructions of how to perform the test. They were asked to test the BioM 4Plex VOC in parallel with their routine Commercial SARS-CoV-2 diagnostic assay. Additionally, they were requested to select SARS-CoV-2-positive samples with genome sequenced and lineage definition according to PANGO lineage classification. FINDINGS The BioM 4Plex VOC and commercial RT-PCR assay are equally effective in detecting SARS-CoV-2. Results revealed a specificity of 96.5-100% [95% confidence interval (CI)], a sensitivity of 99.8-100% (95% CI), and an accuracy of 99.8-100% (95% CI). A 99% concordance rate was found between results from the BioM 4Plex VOC and that from available genome sequencing data. MAIN CONCLUSIONS The BioM 4Plex VOC provides an effective solution to detect SARS-CoV-2 infections and screening for VOCs in a single reaction. It is a straightforward method to help us monitor the frequency and distribution of VOCs and develop strategies to better cope with the pandemics.

4.
An Acad Bras Cienc ; 94(suppl 3): e20211361, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36417609

RESUMO

Since the first reported case of COVID-19 in Brazil, the public and private educational system started to close. Up to November 2020, scientific discussions about the return of schooling activities have been rarely performed by the national scientific community and police-makers. The great delay of school returning in Brazil contrasts with successful international strategies of school reopening worldwide and seems counterintuitive with the reopening of non-essential activities. Here, important issues to be considered before and during school reopening are reviewed and discussed. COVID-19 testing is essential to avoid disease spreading, but high cost of individual RT-qPCRs impairs an extensive testing strategy for school returning. To reduce costs and increase the speed of diagnosis, we tested the efficiency of a pooled-sample PCR strategy in a cohort of the educational staff in the city of Macaé/RJ, finding five asymptomatic individuals (0,66%) among the 754 people tested. Thus, a polled-sample PCR testing strategy of the educational staff might prevent infection spreading in schools at a reasonable cost. We discuss how our test strategy could be coupled with internationally recognized safety rules to allow for a safe school return and how countries from different world regions are dealing with educational activities during COVID-19 pandemic.


Assuntos
COVID-19 , Humanos , COVID-19/epidemiologia , Pandemias , Teste para COVID-19 , Brasil/epidemiologia , Instituições Acadêmicas
5.
Microbiol Spectr ; 10(3): e0125022, 2022 06 29.
Artigo em Inglês | MEDLINE | ID: mdl-35652635

RESUMO

Community testing is a crucial tool for the early identification of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and transmission control. The emergence of the highly mutated Omicron variant (B.1.1.529) raised concerns about its primary site of replication, impacting sample collection and its detectability by rapid antigen tests. We tested the performance of the Panbio antigen rapid diagnostic test (Ag-RDT) using nasal and oral specimens for COVID-19 diagnosis in 192 symptomatic individuals, with quantitative reverse transcription-PCR (RT-qPCR) of nasopharyngeal samples as a control. Variant of concern (VOC) investigation was performed with the 4Plex SARS-CoV-2 screening kit. The SARS-CoV-2 positivity rate was 66.2%, with 99% of the positive samples showing an amplification profile consistent with that of the Omicron variant. Nasal Ag-RDT showed higher sensitivity (89%) than oral (12.6%) Ag-RDT. Our data showed good performance of the Ag-RDT in a pandemic scenario dominated by the Omicron VOC. Furthermore, our data also demonstrated that the Panbio COVID-19 antigen rapid diagnostic test does not provide good sensitivity with oral swabs for Omicron Ag-RDT detection. IMPORTANCE This study showed that the antigen rapid test for COVID19 worked fine using nasal swabs when it was utilized in patients infected with the Omicron variant, showing a concordance with PCR in 93% of patients tested. The nasal swab yielded more reliable results than the oral swab when an antigen rapid diagnosis test (the Panbio COVID-19 antigen rapid diagnostic test) was used in patients infected with the Omicron variant.


Assuntos
COVID-19 , COVID-19/diagnóstico , Teste para COVID-19 , Testes Diagnósticos de Rotina , Humanos , SARS-CoV-2/genética , Sensibilidade e Especificidade
8.
Sci Rep ; 11(1): 20121, 2021 10 11.
Artigo em Inglês | MEDLINE | ID: mdl-34635707

RESUMO

The Brazilian strategy to overcome the spread of COVID-19 has been particularly criticized due to the lack of a national coordinating effort and an appropriate testing program. Here, a successful approach to control the spread of COVID-19 transmission is described by the engagement of public (university and governance) and private sectors (hospitals and oil companies) in Macaé, state of Rio de Janeiro, Brazil, a city known as the National Oil Capital. In 2020 between the 17th and 38th epidemiological week, over two percent of the 206,728 citizens were subjected to symptom analysis and RT-qPCR testing by the Federal University of Rio de Janeiro, with positive individuals being notified up to 48 h after swab collection. Geocodification and spatial cluster analysis were used to limit COVID-19 spreading in Macaé. Within the first semester after the outbreak of COVID-19 in Brazil, Macaé recorded 1.8% of fatalities associated with COVID-19 up to the 38th epidemiological week, which was at least five times lower than the state capital (10.6%). Overall, considering the successful experience of this joint effort of private and public engagement in Macaé, our data suggest that the development of a similar strategy countrywise could have contributed to a better control of the COVID-19 spread in Brazil. Quarantine decree by the local administration, comprehensive molecular testing coupled to scientific analysis of COVID-19 spreading, prevented the catastrophic consequences of the pandemic as seen in other populous cities within the state of Rio de Janeiro and elsewhere in Brazil.


Assuntos
Teste de Ácido Nucleico para COVID-19/estatística & dados numéricos , COVID-19/epidemiologia , Pandemias/estatística & dados numéricos , SARS-CoV-2/isolamento & purificação , Adolescente , Adulto , Idoso , Brasil/epidemiologia , COVID-19/diagnóstico , COVID-19/transmissão , COVID-19/virologia , Cidades/epidemiologia , Cidades/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , Adulto Jovem
9.
Infect Genet Evol ; 95: 104981, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34197917

RESUMO

Mayaro virus (MAYV) has historically been associated with sylvatic transmission; however, urban outbreaks have been reported in Brazil, including cases of co-detection with dengue virus (DENV). Therefore, we performed a molecular survey to investigate MAYV circulation and cocirculation with DENV within Goiania, a major city in Central-West Brazil. Among 375 subjects with arbovirus-like symptoms, 259 were positive for DENV and 26 for MAYV. Of these, 17 were coinfected with DENV-2, suggesting co-transmission of the viruses. The most common complaints at the time of inclusion were myalgia, headache, fever, arthralgia, retro-orbital pain, and skin rash. No specific symptoms were associated with MAYV when either detected alone or co-detected with DENV, compared to that when DENV was detected alone. Most MAYV-infected subjects were women with no recent travel history to rural/sylvatic areas. Phylogenetic reconstruction indicated that the MAYV identified in this study is closely related with a lineage observed in Peru, belonging to genotype D. Our results corroborate the growing circulation of MAYV in urban environments in Brazil and reinforce the need to implement laboratory diagnosis in the Unified Health System, considering that the clinical manifestations of Mayaro fever are similar to those of other arboviruses, particularly dengue. Furthermore, most cases occurred in association with DENV-2. Further phylogenetic studies are needed to evaluate MAYV, which has not been widely examined.


Assuntos
Infecções por Alphavirus/epidemiologia , Alphavirus/fisiologia , Febre/epidemiologia , Adulto , Idoso , Alphavirus/genética , Infecções por Alphavirus/virologia , Brasil/epidemiologia , Feminino , Febre/virologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Epidemiologia Molecular , Prevalência , Adulto Jovem
10.
Braz J Infect Dis ; 25(2): 101542, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33587923

RESUMO

In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Assuntos
Febre de Chikungunya , Vírus Chikungunya , Vírus da Dengue , Dengue , Infecção por Zika virus , Zika virus , Brasil , Febre de Chikungunya/diagnóstico , Vírus Chikungunya/genética , Dengue/diagnóstico , Vírus da Dengue/genética , Humanos , Laboratórios , Zika virus/genética , Infecção por Zika virus/diagnóstico
11.
Braz. j. infect. dis ; 25(2): 101542, 2021. tab
Artigo em Inglês | LILACS | ID: biblio-1278571

RESUMO

ABSTRACT In response to the Zika epidemics in Brazil, the ZDC molecular assay (Bio-Manguinhos) was developed and registered at the Brazilian Regulatory Agency of Health Surveillance - ANVISA. The circulation of Zika (ZIKV) Dengue (DENV) and Chikungunya (CHIKV) viruses and their clinical similarities are challenges to correctly diagnose these viruses. The simultaneous detection of ZIKV, DENV and CHIKV is an important tool for diagnosis and surveillance. Here, we present the analytical and clinical performance evaluation of ZDC molecular assay (Bio-Manguinhos) at the public health laboratories three years after its registration at ANVISA. The clinical performance demonstrates the ZDC molecular assay (Bio-Manguinhos) has 100% sensitivity and 100% specificity to detect and discriminate ZIKV, CHIKV, and DENV from clinical plasma samples. The ZDC molecular assay (Bio-Manguinhos) results were highly reproducible and no cross-reactivity was seen during testing with a panel of other infectious agents. In conclusion, the ZDC molecular assay (Bio-Manguinhos) is an accurate and reliable tool to monitor Zika, dengue and chikungunya infections in countries like Brazil with simultaneous circulation of the three viruses.


Assuntos
Humanos , Zika virus/genética , Infecção por Zika virus/diagnóstico , Brasil , Vírus Chikungunya/genética , Dengue/diagnóstico , Vírus da Dengue/genética , Febre de Chikungunya/diagnóstico , Laboratórios
12.
Rev Soc Bras Med Trop ; 53: e20200477, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33027418

RESUMO

Recent reports indicate that besides respiratory and systemic symptoms among coronavirus disease (COVID-19) patients, the disease has a wide spectrum of neurological manifestations (encephalitis, meningitis, myelitis, acute disseminated encephalomyelitis, metabolic and acute hemorrhagic necrotizing encephalopathy, cerebrovascular diseases, Guillain-Barré syndrome, polyneuritis cranialis, dysautonomia, and myopathies). The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can spread from the respiratory system to the central nervous system, using transneuronal and hematogenous mechanisms. Although not every COVID-19 patient will test positive for the virus in the cerebrospinal fluid exam, the appearance of neurological symptoms associated with SARS-CoV-2 infection reveals the importance of understanding the neurologic manifestations and capacity for neural invasion associated with the pathogen. These aspects are relevant for correct diagnosis and treatment, and for the potential development of vaccines. This review highlights the latest evidence of SARS-CoV-2 infection with a focus on neurological involvement and potential neuropathogenesis mechanisms.


Assuntos
Betacoronavirus , Doenças do Sistema Nervoso Central/etiologia , Infecções por Coronavirus , Pandemias , Pneumonia Viral , COVID-19 , Teste para COVID-19 , Técnicas de Laboratório Clínico , Infecções por Coronavirus/complicações , Infecções por Coronavirus/diagnóstico , Humanos , Pneumonia Viral/complicações , Pneumonia Viral/diagnóstico , SARS-CoV-2
14.
Malar J ; 19(1): 275, 2020 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-32736625

RESUMO

BACKGROUND: Malaria can be transmitted by blood transfusion through donations collected from asymptomatic donors. Transfusion-transmitted malaria (TTM) poses a great risk to blood services worldwide. A good screening tool for Plasmodium spp. detection in blood banks must have a high sensitivity for prevention of TTM. However, in Brazilian blood banks, screening for malaria still relies on microscopy. METHODS: In Brazil, screening for human immunodeficiency virus type 1 (HIV), RNA/DNA for hepatitis C (HCV) and hepatitis B (HBV) viruses is mandatory for every blood donation and uses nucleic acid amplification testing (NAT). The aim of this study was to evaluate the inclusion of an assay for malaria to identify Plasmodium sp. from total nucleic acid (TNA; DNA/RNA) by targeting the 18S rRNA gene of the parasite. RESULTS: Considering the limitations of microscopy and the wide availability of the Brazilian NAT platform in the screening of blood units for HIV, HCV, and HBV, a molecular diagnostic tool was validated for detection of Plasmodium sp. in blood banks; a pilot study showed that using this novel NAT assay could reduce the risk of TTM. CONCLUSION: The prototype HIV/HCV/HBV/malaria NAT assay was effective in detecting infected candidate donors and has good prospects to be applied in routine screening for preventing TTM.


Assuntos
Malária/prevenção & controle , Programas de Rastreamento/métodos , Técnicas de Amplificação de Ácido Nucleico/métodos , Plasmodium/isolamento & purificação , Vigilância da População/métodos , Adolescente , Adulto , Bancos de Sangue , Transfusão de Sangue , Brasil , Monitoramento Epidemiológico , Feminino , Infecções por HIV/diagnóstico , Hepatite B/diagnóstico , Hepatite C/diagnóstico , Humanos , Malária/transmissão , Masculino , Programas de Rastreamento/instrumentação , Pessoa de Meia-Idade , Projetos Piloto , Plasmodium/genética , RNA de Protozoário/análise , RNA Ribossômico 18S/análise , Adulto Jovem
15.
Genet Mol Biol ; 43(1): e20180237, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31644681

RESUMO

Hepatitis C virus (HCV) infection is a worldwide health problem. Nowadays, direct-acting antiviral agents (DAAs) are the main treatment for HCV; however, the high level of virus variability leads to the development of resistance-associated variants (RAVs). Thus, assessing RAVs in infected patients is important for monitoring treatment efficacy. The aim of our study was to investigate the presence of naturally occurring resistance mutations in HCV NS3 and NS5 regions in treatment-naïve patients. Ninety-six anti-HCV positive serum samples from blood donors at the Center of Hematology and Hemotherapy of Santa Catarina State (HEMOSC) were collected retrospectively in 2013 and evaluated in this study. HCV 1a (37.9%), 1b (25.3%), and 3a (36.8%) subtypes were found. The frequency of patients with RAVs in our study was 6.9%. The HCV NS5b sequencing reveled 1 sample with L320F mutation and 4 samples with the C316N/R polymorphism. The analysis of the NS3 region revealed the D168A/G/T (3.45%), S122G (1.15%), and V55A (2.3%) mutations. All samples from genotype 3a (36.8%) presented the V170 I/V non-synonymous mutation. In conclusion, we have shown that mutations in NS3 and NS5b genes are present in Brazilian isolates from therapy-naïve HCV patients.

16.
Rev. Soc. Bras. Med. Trop ; 53: e20200477, 2020. tab, graf
Artigo em Inglês | SES-SP, Coleciona SUS (Brasil), LILACS | ID: biblio-1136842

RESUMO

Abstract Recent reports indicate that besides respiratory and systemic symptoms among coronavirus disease (COVID-19) patients, the disease has a wide spectrum of neurological manifestations (encephalitis, meningitis, myelitis, acute disseminated encephalomyelitis, metabolic and acute hemorrhagic necrotizing encephalopathy, cerebrovascular diseases, Guillain-Barré syndrome, polyneuritis cranialis, dysautonomia, and myopathies). The severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) can spread from the respiratory system to the central nervous system, using transneuronal and hematogenous mechanisms. Although not every COVID-19 patient will test positive for the virus in the cerebrospinal fluid exam, the appearance of neurological symptoms associated with SARS-CoV-2 infection reveals the importance of understanding the neurologic manifestations and capacity for neural invasion associated with the pathogen. These aspects are relevant for correct diagnosis and treatment, and for the potential development of vaccines. This review highlights the latest evidence of SARS-CoV-2 infection with a focus on neurological involvement and potential neuropathogenesis mechanisms.


Assuntos
Humanos , Pneumonia Viral , Pneumonia Viral/diagnóstico , Doenças do Sistema Nervoso Central/etiologia , Infecções por Coronavirus/complicações , Infecções por Coronavirus/diagnóstico , Pandemias , Betacoronavirus , Infecções por Coronavirus , Técnicas de Laboratório Clínico
17.
Braz. j. infect. dis ; 22(5): 418-423, Sept.-Oct. 2018. tab, graf
Artigo em Inglês | LILACS | ID: biblio-974233

RESUMO

ABSTRACT The Brazilian Public Health Service provides freely αPEG-IFN to treat patients infected with HCV. The primary goal of HCV therapy is the long-term elimination of HCV from the blood to reduce the risk of HCV associated complications and death. Patient viremia affects the treatment duration and response, thus influencing clinical decisions. We developed a high-throughput method to perform the quantification of RNA hepatitis C virus (HCV) virus load in plasma samples to monitor patients under treatment. The method is based on a duplex detection, in a one-step real-time RT-PCR assay and it has been validated according to the rules established by the official Brazilian regulatory agency (ANVISA). This new method was compared to a commercial kit (Cobas/Taqman HCV Test v2.0 - Roche), showing virus load results with significant correlation between them (p= 0,012) using commercial and clinical panels. In addition, 611 samples from patients treated with peguilated alfa-interferon (αPEG-IFN) from different regions of Brazil were analyzed. Our one-step real-time RT-PCR assay demonstrated good performance in viral load measurement and in treatment course monitoring, with acceptable sensitivity and specificity values.


Assuntos
Humanos , RNA Viral/isolamento & purificação , Hepatite C/virologia , Hepacivirus/isolamento & purificação , Carga Viral/métodos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Antivirais/uso terapêutico , Polietilenoglicóis/uso terapêutico , Fatores de Tempo , Viremia , Proteínas Recombinantes/uso terapêutico , Brasil , RNA Viral/genética , RNA Viral/sangue , Estudos Prospectivos , Reprodutibilidade dos Testes , Interferon-alfa/uso terapêutico , Hepatite C/tratamento farmacológico , Hepatite C/sangue , Hepacivirus/genética , Técnicas de Genotipagem , Genótipo
18.
Braz J Infect Dis ; 22(5): 418-423, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30243981

RESUMO

The Brazilian Public Health Service provides freely αPEG-IFN to treat patients infected with HCV. The primary goal of HCV therapy is the long-term elimination of HCV from the blood to reduce the risk of HCV associated complications and death. Patient viremia affects the treatment duration and response, thus influencing clinical decisions. We developed a high-throughput method to perform the quantification of RNA hepatitis C virus (HCV) virus load in plasma samples to monitor patients under treatment. The method is based on a duplex detection, in a one-step real-time RT-PCR assay and it has been validated according to the rules established by the official Brazilian regulatory agency (ANVISA). This new method was compared to a commercial kit (Cobas/Taqman HCV Test v2.0 - Roche), showing virus load results with significant correlation between them (p = 0,012) using commercial and clinical panels. In addition, 611 samples from patients treated with peguilated alfa-interferon (αPEG-IFN) from different regions of Brazil were analyzed. Our one-step real-time RT-PCR assay demonstrated good performance in viral load measurement and in treatment course monitoring, with acceptable sensitivity and specificity values.


Assuntos
Hepacivirus/isolamento & purificação , Hepatite C/virologia , RNA Viral/isolamento & purificação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Carga Viral/métodos , Antivirais/uso terapêutico , Brasil , Genótipo , Técnicas de Genotipagem , Hepacivirus/genética , Hepatite C/sangue , Hepatite C/tratamento farmacológico , Humanos , Interferon-alfa/uso terapêutico , Polietilenoglicóis/uso terapêutico , Estudos Prospectivos , RNA Viral/sangue , RNA Viral/genética , Proteínas Recombinantes/uso terapêutico , Reprodutibilidade dos Testes , Fatores de Tempo , Viremia
19.
Int J Infect Dis ; 72: 25-27, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29738826

RESUMO

We describe a case of fetal death associated with a recent infection by Chikungunya virus (CHIKV) in a Brazilian pregnant woman (positive RT-PCR in blood and placenta). Zika virus (ZIKV) infection during pregnancy was also identified, based on a positive RT-PCR in a fetal kidney specimen. The maternal infection caused by the ZIKV was asymptomatic and the CHIKV infection had a classical clinical presentation. The fetus had no apparent anomalies, but her weight was between the 3rd and 10th percentile for the gestational age. This is the second case report of congenital arboviral co-infection and the first followed by antepartum fetal death.


Assuntos
Febre de Chikungunya/virologia , Morte Fetal/etiologia , Placenta/virologia , Complicações Infecciosas na Gravidez/virologia , Infecção por Zika virus/virologia , Brasil , Febre de Chikungunya/patologia , Coinfecção/virologia , Feminino , Idade Gestacional , Humanos , Gravidez , Complicações Infecciosas na Gravidez/patologia , Adulto Jovem , Infecção por Zika virus/patologia
20.
Transfusion ; 58(4): 862-870, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29383720

RESUMO

BACKGROUND: The history of the development and implementation of the Brazilian nucleic acid testing (NAT) platform to detect and discriminate among human immunodeficiency virus (HIV), hepatitis C virus (HCV), and hepatitis B virus (HBV) infections in blood donors is described here. The results for the sensitivity, reproducibility, and NAT yield of the platform since program implementation are provided. STUDY DESIGN AND METHODS: The Brazilian NAT HIV, HCV, and HBV kit was developed and evaluated with regard to analytical sensitivity, specificity, intralot and interlot reproducibility, interfering substances, and genotype and diagnostic sensitivity. Additionally, a sample of identified NAT-yield cases was characterized with regard to viral load. RESULTS: The 95% limits of detection for HIV, HCV, and HBV were 68.02, 102.35, and 9.08 IU/mL, respectively. All replicates were detected with reproducibility assays between the acceptable values. A total of 13,610,536 blood donors was screened from 2010 to 2016, and 63 HIV-yield cases and 28 HCV-yield cases were detected. Among 5,795,424 blood donors screened for HBV from 2014 to 2016, 42 yield cases were found. CONCLUSION: The Brazilian NAT HIV, HCV, and HBV kit is an automated NAT system suitable for routine blood donor screening in a completely traceable process. The analytical sensitivity as well as the diagnostic sensitivity fulfilled all requirements set by the health ministry for blood donor screening. A significant number of transmission cases were prevented by the implementation of this important program.


Assuntos
Doadores de Sangue , Segurança do Sangue , DNA Viral/sangue , Infecções por HIV/diagnóstico , Hepatite B/diagnóstico , Hepatite C/diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Viremia/diagnóstico , Automação , Segurança do Sangue/instrumentação , Segurança do Sangue/métodos , Segurança do Sangue/normas , Brasil , Infecções por HIV/sangue , Hepatite B/sangue , Hepatite C/sangue , Humanos , Programas de Rastreamento/métodos , Reação em Cadeia da Polimerase em Tempo Real/instrumentação , Reação em Cadeia da Polimerase em Tempo Real/métodos , Reação em Cadeia da Polimerase em Tempo Real/normas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Carga Viral , Viremia/transmissão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA