Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 168
Filtrar
1.
medRxiv ; 2024 Sep 12.
Artigo em Inglês | MEDLINE | ID: mdl-39314948

RESUMO

Purpose: This study aims to identify radiomic features extracted from contrast-enhanced CT scans that differentiate osteoradionecrosis (ORN) from normal mandibular bone in patients with head and neck cancer (HNC) treated with radiotherapy (RT). Materials and Methods: Contrast-enhanced CT (CECT) images were collected for 150 patients (80% train, 20% test) with confirmed ORN diagnosis at The University of Texas MD Anderson Cancer Center between 2008 and 2018. Using PyRadiomics, radiomic features were extracted from manually segmented ORN regions and the corresponding automated control regions, the later defined as the contralateral healthy mandible region. A subset of pre-selected features was obtained based on correlation analysis (r > 0.95) and used to train a Random Forest (RF) classifier with Recursive Feature Elimination. Model explainability SHapley Additive exPlanations (SHAP) analysis was performed on the 20 most important features identified by the trained RF classifier. Results: From a total of 1316 radiomic features extracted, 810 features were excluded due to high collinearity. From a set of 506 pre-selected radiomic features, the optimal subset resulting on the best discriminative accuracy of the RF classifier consisted of 67 features. The RF classifier was well calibrated (Log Loss 0.296, ECE 0.125) and achieved an accuracy of 88% and a ROC AUC of 0.96. The SHAP analysis revealed that higher values of Wavelet-LLH First-order Mean and Median were associated with ORN of the jaw (ORNJ). Conversely, higher Exponential GLDM Dependence Entropy and lower Square First-order Kurtosis were more characteristic of normal mandibular tissue. Conclusion: This study successfully developed a CECT-based radiomics model for differentiating ORNJ from healthy mandibular tissue in HNC patients after RT. Future work will focus on the detection of subclinical ORNJ regions to guide earlier interventions.

2.
Sci Rep ; 14(1): 20988, 2024 09 09.
Artigo em Inglês | MEDLINE | ID: mdl-39251664

RESUMO

Image segmentation of the liver is an important step in treatment planning for liver cancer. However, manual segmentation at a large scale is not practical, leading to increasing reliance on deep learning models to automatically segment the liver. This manuscript develops a generalizable deep learning model to segment the liver on T1-weighted MR images. In particular, three distinct deep learning architectures (nnUNet, PocketNet, Swin UNETR) were considered using data gathered from six geographically different institutions. A total of 819 T1-weighted MR images were gathered from both public and internal sources. Our experiments compared each architecture's testing performance when trained both intra-institutionally and inter-institutionally. Models trained using nnUNet and its PocketNet variant achieved mean Dice-Sorensen similarity coefficients>0.9 on both intra- and inter-institutional test set data. The performance of these models suggests that nnUNet and PocketNet liver segmentation models trained on a large and diverse collection of T1-weighted MR images would on average achieve good intra-institutional segmentation performance.


Assuntos
Aprendizado Profundo , Hepatopatias , Fígado , Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Fígado/diagnóstico por imagem , Fígado/patologia , Hepatopatias/diagnóstico por imagem , Hepatopatias/patologia , Meios de Contraste , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia
3.
Br J Surg ; 111(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39213397

RESUMO

BACKGROUND: Several ablation confirmation software methods for minimum ablative margin assessment have recently been developed to improve local outcomes for patients undergoing thermal ablation of colorectal liver metastases. Previous assessments were limited to single institutions mostly at the place of development. The aim of this study was to validate the previously identified 5 mm minimum ablative margin (A0) using autosegmentation and biomechanical deformable image registration in a multi-institutional setting. METHODS: This was a multicentre, retrospective study including patients with colorectal liver metastases undergoing CT- or ultrasound-guided microwave or radiofrequency ablation during 2009-2022, reporting 3-year local disease progression (residual unablated tumour or local tumour progression) rates by minimum ablative margin across all institutions and identifying an intraprocedural contrast-enhanced CT-based minimum ablative margin associated with a 3-year local disease progression rate of less than 1%. RESULTS: A total of 400 ablated colorectal liver metastases (median diameter of 1.5 cm) in 243 patients (145 men; median age of 62 [interquartile range 54-70] years) were evaluated, with a median follow-up of 26 (interquartile range 17-40) months. A total of 119 (48.9%) patients with 186 (46.5%) colorectal liver metastases were from international institutions B, C, and D that were not involved in the software development. Three-year local disease progression rates for 0 mm, >0 and <5 mm, and 5 mm or larger minimum ablative margins were 79%, 15%, and 0% respectively for institution A (where the software was developed) and 34%, 19%, and 2% respectively for institutions B, C, and D combined. Local disease progression risk decreased to less than 1% with an intraprocedurally confirmed minimum ablative margin greater than 4.6 mm. CONCLUSION: A minimum ablative margin of 5 mm or larger demonstrates optimal local oncological outcomes. It is proposed that an intraprocedural minimum ablative margin of 5 mm or larger, confirmed using biomechanical deformable image registration, serves as the A0 for colorectal liver metastasis thermal ablation.


Assuntos
Inteligência Artificial , Neoplasias Colorretais , Neoplasias Hepáticas , Margens de Excisão , Tomografia Computadorizada por Raios X , Humanos , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/diagnóstico por imagem , Masculino , Estudos Retrospectivos , Feminino , Pessoa de Meia-Idade , Idoso , Progressão da Doença , Ablação por Radiofrequência/métodos
4.
Radiology ; 312(1): e232654, 2024 07.
Artigo em Inglês | MEDLINE | ID: mdl-39078294

RESUMO

Systemic immunotherapies have led to tremendous progress across the cancer landscape. However, several challenges exist, potentially limiting their efficacy in the treatment of solid tumors. Direct intratumoral injection can increase the therapeutic index of immunotherapies while overcoming many of the barriers associated with systemic administration, including limited bioavailability to tumors and potential systemic safety concerns. However, challenges remain, including the lack of standardized approaches for administration, issues relating to effective drug delivery, logistical hurdles, and safety concerns specific to this mode of administration. This article reviews the biologic rationale for the localized injection of immunotherapeutic agents into tumors. It also addresses the existing limitations and practical considerations for safe and effective implementation and provide recommendations for optimizing logistics and treatment workflows. It also highlights the critical role that radiologists, interventional radiologists, and medical physicists play in intratumoral immunotherapy with respect to target selection, image-guided administration, and response assessment.


Assuntos
Imunoterapia , Injeções Intralesionais , Neoplasias , Humanos , Imunoterapia/métodos , Neoplasias/terapia , Injeções Intralesionais/métodos
5.
Radiother Oncol ; 197: 110345, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38838989

RESUMO

BACKGROUND AND PURPOSE: Artificial Intelligence (AI) models in radiation therapy are being developed with increasing pace. Despite this, the radiation therapy community has not widely adopted these models in clinical practice. A cohesive guideline on how to develop, report and clinically validate AI algorithms might help bridge this gap. METHODS AND MATERIALS: A Delphi process with all co-authors was followed to determine which topics should be addressed in this comprehensive guideline. Separate sections of the guideline, including Statements, were written by subgroups of the authors and discussed with the whole group at several meetings. Statements were formulated and scored as highly recommended or recommended. RESULTS: The following topics were found most relevant: Decision making, image analysis, volume segmentation, treatment planning, patient specific quality assurance of treatment delivery, adaptive treatment, outcome prediction, training, validation and testing of AI model parameters, model availability for others to verify, model quality assurance/updates and upgrades, ethics. Key references were given together with an outlook on current hurdles and possibilities to overcome these. 19 Statements were formulated. CONCLUSION: A cohesive guideline has been written which addresses main topics regarding AI in radiation therapy. It will help to guide development, as well as transparent and consistent reporting and validation of new AI tools and facilitate adoption.


Assuntos
Inteligência Artificial , Técnica Delphi , Humanos , Planejamento da Radioterapia Assistida por Computador/normas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia (Especialidade)/normas , Radioterapia/normas , Radioterapia/métodos , Algoritmos
6.
Cancers (Basel) ; 16(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38893214

RESUMO

Microwave ablation (MWA) of liver tumors presents challenges like under- and over-ablation, potentially leading to inadequate tumor destruction and damage to healthy tissue. This study aims to develop personalized three-dimensional (3D) models to simulate MWA for liver tumors, incorporating patient-specific characteristics. The primary objective is to validate the predicted ablation zones compared to clinical outcomes, offering insights into MWA before therapy to facilitate accurate treatment planning. Contrast-enhanced CT images from three patients were used to create 3D models. The simulations used coupled electromagnetic wave propagation and bioheat transfer to estimate the temperature distribution, predicting tumor destruction and ablation margins. The findings indicate that prolonged ablation does not significantly improve tumor destruction once an adequate margin is achieved, although it increases tissue damage. There was a substantial overlap between the clinical ablation zones and the predicted ablation zones. For patient 1, the Dice score was 0.73, indicating high accuracy, with a sensitivity of 0.72 and a specificity of 0.76. For patient 2, the Dice score was 0.86, with a sensitivity of 0.79 and a specificity of 0.96. For patient 3, the Dice score was 0.8, with a sensitivity of 0.85 and a specificity of 0.74. Patient-specific 3D models demonstrate potential in accurately predicting ablation zones and optimizing MWA treatment strategies.

7.
Res Sq ; 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38746406

RESUMO

Image segmentation of the liver is an important step in several treatments for liver cancer. However, manual segmentation at a large scale is not practical, leading to increasing reliance on deep learning models to automatically segment the liver. This manuscript develops a deep learning model to segment the liver on T1w MR images. We sought to determine the best architecture by training, validating, and testing three different deep learning architectures using a total of 819 T1w MR images gathered from six different datasets, both publicly and internally available. Our experiments compared each architecture's testing performance when trained on data from the same dataset via 5-fold cross validation to its testing performance when trained on all other datasets. Models trained using nnUNet achieved mean Dice-Sorensen similarity coefficients > 90% when tested on each of the six datasets individually. The performance of these models suggests that an nnUNet liver segmentation model trained on a large and diverse collection of T1w MR images would be robust to potential changes in contrast protocol and disease etiology.

9.
Eur Radiol ; 34(9): 5541-5550, 2024 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-38334762

RESUMO

PURPOSE: To investigate the correlation of minimal ablative margin (MAM) quantification using biomechanical deformable (DIR) versus intensity-based rigid image registration (RIR) with local outcomes following colorectal liver metastasis (CLM) thermal ablation. METHODS: This retrospective single-institution study included consecutive patients undergoing thermal ablation between May 2016 and October 2021. Patients who did not have intraprocedural pre- and post-ablation contrast-enhanced CT images for MAM quantification or follow-up period less than 1 year without residual tumor or local tumor progression (LTP) were excluded. DIR and RIR methods were used to quantify the MAM. The registration accuracy was compared using Dice similarity coefficient (DSC). Area under the receiver operating characteristic curve (AUC) was used to test MAM in predicting local tumor outcomes. RESULTS: A total of 72 patients (mean age 57; 44 men) with 139 tumors (mean diameter 1.5 cm ± 0.8 (SD)) were included. During a median follow-up of 29.4 months, there was one residual unablated tumor and the LTP rate was 17% (24/138). The ranges of DSC were 0.96-0.98 and 0.67-0.98 for DIR and RIR, respectively (p < 0.001). When using DIR, 27 (19%) tumors were partially or totally registered outside the liver, compared to 46 (33%) with RIR. Using DIR versus RIR, the corresponding median MAM was 4.7 mm versus 4.0 mm, respectively (p = 0.5). The AUC in predicting residual tumor and 1-year LTP for DIR versus RIR was 0.89 versus 0.72, respectively (p < 0.001). CONCLUSION: Ablative margin quantified on intra-procedural CT imaging using DIR method outperformed RIR for predicting local outcomes of CLM thermal ablation. CLINICAL RELEVANCE STATEMENT: The study supports the role of biomechanical deformable image registration as the preferred image registration method over rigid image registration for quantifying minimal ablative margins using intraprocedural contrast-enhanced CT images. KEY POINTS: • Accurate and reproducible image registration is a prerequisite for clinical application of image-based ablation confirmation methods. • When compared to intensity-based rigid image registration, biomechanical deformable image registration for minimal ablative margin quantification was more accurate for liver registration using intraprocedural contrast-enhanced CT images. • Biomechanical deformable image registration outperformed intensity-based rigid image registration for predicting local tumor outcomes following colorectal liver metastasis thermal ablation.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Tomografia Computadorizada por Raios X , Humanos , Masculino , Feminino , Neoplasias Hepáticas/secundário , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Colorretais/patologia , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/cirurgia , Estudos Retrospectivos , Pessoa de Meia-Idade , Tomografia Computadorizada por Raios X/métodos , Margens de Excisão , Idoso , Resultado do Tratamento , Adulto
10.
Radiol Imaging Cancer ; 6(2): e230099, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38363196

RESUMO

CT during hepatic arteriography (CTHA) is a highly sensitive imaging method for detecting colorectal liver metastases (CLMs), which supports its use during percutaneous thermal liver ablation. In contrast to its high sensitivity, its specificity for incidental small CLMs not detected at preablation cross-sectional imaging is believed to be low given the absence of specific imaging signatures and the common presence of pseudolesions. In this retrospective study of 22 patients (mean age, 55 years ± 10.6 [SD]; 63.6% male, 36.4% female) with CLMs undergoing CTHA-guided microwave percutaneous thermal ablation between November 2017 and October 2022, the authors provided a definition of incidental ring-hyperenhancing liver micronodules (RHLMs) and investigated whether there is a correlation of RHLMs with histologic analysis or intrahepatic tumor progression at imaging follow-up after applying a biomechanical deformable image registration method. The analysis revealed 25 incidental RHLMs in 41.7% (10 of 24) of the CTHA images from the respective guided ablation sessions. Of those, four RHLMs were ablated. Among the remaining 21 RHLMs, 71.4% (15 of 21) were confirmed to be CLM with either histology (n = 3) or imaging follow-up (n = 12). The remaining 28.6% (six of 21) of RHLMs were not observed at follow-up imaging. This suggests that RHLMs at CTHA may be an early indicator of incidental small CLMs. Keywords: Colorectal Neoplasms, Liver, Angiography, CT, Incidental Findings, Ablation Supplemental material is available for this article. © RSNA, 2024.


Assuntos
Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Estudos Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Colorretais/diagnóstico por imagem , Angiografia/métodos , Tomografia Computadorizada por Raios X/métodos
11.
Sci Rep ; 14(1): 4678, 2024 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409252

RESUMO

Manual delineation of liver segments on computed tomography (CT) images for primary/secondary liver cancer (LC) patients is time-intensive and prone to inter/intra-observer variability. Therefore, we developed a deep-learning-based model to auto-contour liver segments and spleen on contrast-enhanced CT (CECT) images. We trained two models using 3d patch-based attention U-Net ([Formula: see text] and 3d full resolution of nnU-Net ([Formula: see text] to determine the best architecture ([Formula: see text]. BA was used with vessels ([Formula: see text] and spleen ([Formula: see text] to assess the impact on segment contouring. Models were trained, validated, and tested on 160 ([Formula: see text]), 40 ([Formula: see text]), 33 ([Formula: see text]), 25 (CCH) and 20 (CPVE) CECT of LC patients. [Formula: see text] outperformed [Formula: see text] across all segments with median differences in Dice similarity coefficients (DSC) ranging 0.03-0.05 (p < 0.05). [Formula: see text], and [Formula: see text] were not statistically different (p > 0.05), however, both were slightly better than [Formula: see text] by DSC up to 0.02. The final model, [Formula: see text], showed a mean DSC of 0.89, 0.82, 0.88, 0.87, 0.96, and 0.95 for segments 1, 2, 3, 4, 5-8, and spleen, respectively on entire test sets. Qualitatively, more than 85% of cases showed a Likert score [Formula: see text] 3 on test sets. Our final model provides clinically acceptable contours of liver segments and spleen which are usable in treatment planning.


Assuntos
Aprendizado Profundo , Neoplasias Hepáticas , Humanos , Baço/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos
12.
Med Phys ; 51(1): 278-291, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37475466

RESUMO

BACKGROUND: In order to accurately accumulate delivered dose for head and neck cancer patients treated with the Adapt to Position workflow on the 1.5T magnetic resonance imaging (MRI)-linear accelerator (MR-linac), the low-resolution T2-weighted MRIs used for daily setup must be segmented to enable reconstruction of the delivered dose at each fraction. PURPOSE: In this pilot study, we evaluate various autosegmentation methods for head and neck organs at risk (OARs) on on-board setup MRIs from the MR-linac for off-line reconstruction of delivered dose. METHODS: Seven OARs (parotid glands, submandibular glands, mandible, spinal cord, and brainstem) were contoured on 43 images by seven observers each. Ground truth contours were generated using a simultaneous truth and performance level estimation (STAPLE) algorithm. Twenty total autosegmentation methods were evaluated in ADMIRE: 1-9) atlas-based autosegmentation using a population atlas library (PAL) of 5/10/15 patients with STAPLE, patch fusion (PF), random forest (RF) for label fusion; 10-19) autosegmentation using images from a patient's 1-4 prior fractions (individualized patient prior [IPP]) using STAPLE/PF/RF; 20) deep learning (DL) (3D ResUNet trained on 43 ground truth structure sets plus 45 contoured by one observer). Execution time was measured for each method. Autosegmented structures were compared to ground truth structures using the Dice similarity coefficient, mean surface distance (MSD), Hausdorff distance (HD), and Jaccard index (JI). For each metric and OAR, performance was compared to the inter-observer variability using Dunn's test with control. Methods were compared pairwise using the Steel-Dwass test for each metric pooled across all OARs. Further dosimetric analysis was performed on three high-performing autosegmentation methods (DL, IPP with RF and 4 fractions [IPP_RF_4], IPP with 1 fraction [IPP_1]), and one low-performing (PAL with STAPLE and 5 atlases [PAL_ST_5]). For five patients, delivered doses from clinical plans were recalculated on setup images with ground truth and autosegmented structure sets. Differences in maximum and mean dose to each structure between the ground truth and autosegmented structures were calculated and correlated with geometric metrics. RESULTS: DL and IPP methods performed best overall, all significantly outperforming inter-observer variability and with no significant difference between methods in pairwise comparison. PAL methods performed worst overall; most were not significantly different from the inter-observer variability or from each other. DL was the fastest method (33 s per case) and PAL methods the slowest (3.7-13.8 min per case). Execution time increased with a number of prior fractions/atlases for IPP and PAL. For DL, IPP_1, and IPP_RF_4, the majority (95%) of dose differences were within ± 250 cGy from ground truth, but outlier differences up to 785 cGy occurred. Dose differences were much higher for PAL_ST_5, with outlier differences up to 1920 cGy. Dose differences showed weak but significant correlations with all geometric metrics (R2 between 0.030 and 0.314). CONCLUSIONS: The autosegmentation methods offering the best combination of performance and execution time are DL and IPP_1. Dose reconstruction on on-board T2-weighted MRIs is feasible with autosegmented structures with minimal dosimetric variation from ground truth, but contours should be visually inspected prior to dose reconstruction in an end-to-end dose accumulation workflow.


Assuntos
Neoplasias de Cabeça e Pescoço , Planejamento da Radioterapia Assistida por Computador , Humanos , Projetos Piloto , Fluxo de Trabalho , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Neoplasias de Cabeça e Pescoço/radioterapia , Imageamento por Ressonância Magnética/métodos , Órgãos em Risco
13.
Invest Radiol ; 59(4): 314-319, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37812469

RESUMO

OBJECTIVES: The aim of this study was to investigate the prognostic value of 3-dimensional minimal ablative margin (MAM) quantified by intraprocedural versus initial follow-up computed tomography (CT) in predicting local tumor progression (LTP) after colorectal liver metastasis (CLM) thermal ablation. MATERIALS AND METHODS: This single-institution, patient-clustered, tumor-based retrospective study included patients undergoing microwave and radiofrequency ablation between 2016 and 2021. Patients without intraprocedural and initial follow-up contrast-enhanced CT, residual tumors, or with follow-up less than 1 year without LTP were excluded. Minimal ablative margin was quantified by a biomechanical deformable image registration method with segmentations of CLMs on intraprocedural preablation CT and ablation zones on intraprocedural postablation and initial follow-up CT. Prognostic value of MAM to predict LTP was tested using area under the curve and competing-risk regression model. RESULTS: A total of 68 patients (mean age ± standard deviation, 57 ± 12 years; 43 men) with 133 CLMs were included. During a median follow-up of 30.3 months, LTP rate was 17% (22/133). The median volume of ablation zone was 27 mL and 16 mL segmented on intraprocedural and initial follow-up CT, respectively ( P < 0.001), with corresponding median MAM of 4.7 mm and 0 mm, respectively ( P < 0.001). The area under the curve was higher for MAM quantified on intraprocedural CT (0.89; 95% confidence interval [CI], 0.83-0.94) compared with initial follow-up CT (0.66; 95% CI, 0.54-0.76) in predicting 1-year LTP ( P < 0.001). An MAM of 0 mm on intraprocedural CT was an independent predictor of LTP with a subdistribution hazards ratio of 11.9 (95% CI, 4.9-28.9; P < 0.001), compared with 2.4 (95% CI, 0.9-6.0; P = 0.07) on initial follow-up CT. CONCLUSIONS: Ablative margin quantified on intraprocedural CT significantly outperformed initial follow-up CT in predicting LTP and should be used for ablation endpoint assessment.


Assuntos
Ablação por Cateter , Neoplasias Colorretais , Neoplasias Hepáticas , Masculino , Humanos , Seguimentos , Estudos Retrospectivos , Resultado do Tratamento , Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Neoplasias Colorretais/patologia
14.
Int J Radiat Oncol Biol Phys ; 118(1): 231-241, 2024 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-37552151

RESUMO

PURPOSE: The aim of this study was to investigate the dosimetric and clinical effects of 4-dimensional computed tomography (4DCT)-based longitudinal dose accumulation in patients with locally advanced non-small cell lung cancer treated with standard-fractionated intensity-modulated radiation therapy (IMRT). METHODS AND MATERIALS: Sixty-seven patients were retrospectively selected from a randomized clinical trial. Their original IMRT plan, planning and verification 4DCTs, and ∼4-month posttreatment follow-up CTs were imported into a commercial treatment planning system. Two deformable image registration algorithms were implemented for dose accumulation, and their accuracies were assessed. The planned and accumulated doses computed using average-intensity images or phase images were compared. At the organ level, mean lung dose and normal-tissue complication probability (NTCP) for grade ≥2 radiation pneumonitis were compared. At the region level, mean dose in lung subsections and the volumetric overlap between isodose intervals were compared. At the voxel level, the accuracy in estimating the delivered dose was compared by evaluating the fit of a dose versus radiographic image density change (IDC) model. The dose-IDC model fit was also compared for subcohorts based on the magnitude of NTCP difference (|ΔNTCP|) between planned and accumulated doses. RESULTS: Deformable image registration accuracy was quantified, and the uncertainty was considered for the voxel-level analysis. Compared with planned doses, accumulated doses on average resulted in <1-Gy lung dose increase and <2% NTCP increase (up to 8.2 Gy and 18.8% for a patient, respectively). Volumetric overlap of isodose intervals between the planned and accumulated dose distributions ranged from 0.01 to 0.93. Voxel-level dose-IDC models demonstrated a fit improvement from planned dose to accumulated dose (pseudo-R2 increased 0.0023) and a further improvement for patients with ≥2% |ΔNTCP| versus for patients with <2% |ΔNTCP|. CONCLUSIONS: With a relatively large cohort, robust image registrations, multilevel metric comparisons, and radiographic image-based evidence, we demonstrated that dose accumulation more accurately represents the delivered dose and can be especially beneficial for patients with greater longitudinal response.


Assuntos
Carcinoma Pulmonar de Células não Pequenas , Neoplasias Pulmonares , Radioterapia de Intensidade Modulada , Humanos , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Estudos Retrospectivos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada Quadridimensional/métodos
15.
BMC Med Res Methodol ; 23(1): 250, 2023 10 26.
Artigo em Inglês | MEDLINE | ID: mdl-37884857

RESUMO

BACKGROUND: Evidence-based treatment decisions in medicine are made founded on population-level evidence obtained during randomized clinical trials. In an era of personalized medicine, these decisions should be based on the predicted benefit of a treatment on a patient-level. Survival prediction models play a central role as they incorporate the time-to-event and censoring. In medical applications uncertainty is critical especially when treatments differ in their side effect profiles or costs. Additionally, models must be adapted to local populations without diminishing performance and often without the original training data available due to privacy concern. Both points are supported by Bayesian models-yet they are rarely used. The aim of this work is to evaluate Bayesian parametric survival models on public datasets including cardiology, infectious diseases, and oncology. MATERIALS AND METHODS: Bayesian parametric survival models based on the Exponential and Weibull distribution were implemented as a Python package. A linear combination and a neural network were used for predicting the parameters of the distributions. A superiority design was used to assess whether Bayesian models are better than commonly used models such as Cox Proportional Hazards, Random Survival Forest, and Neural Network-based Cox Proportional Hazards. In a secondary analysis, overfitting was compared between these models. An equivalence design was used to assess whether the prediction performance of Bayesian models after model updating using Bayes rule is equivalent to retraining on the full dataset. RESULTS: In this study, we found that Bayesian parametric survival models perform as good as state-of-the art models while requiring less hyperparameters to be tuned and providing a measure of the uncertainty of the predictions. In addition, these models were less prone to overfitting. Furthermore, we show that updating these models using Bayes rule yields equivalent performance compared to models trained on combined original and new datasets. CONCLUSIONS: Bayesian parametric survival models are non-inferior to conventional survival models while requiring less hyperparameter tuning, being less prone to overfitting, and allowing model updating using Bayes rule. Further, the Bayesian models provide a measure of the uncertainty on the statistical inference, and, in particular, on the prediction.


Assuntos
Redes Neurais de Computação , Humanos , Teorema de Bayes , Incerteza
16.
J Appl Clin Med Phys ; 24(12): e14131, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37670488

RESUMO

PURPOSE: Two-dimensional radiotherapy is often used to treat cervical cancer in low- and middle-income countries, but treatment planning can be challenging and time-consuming. Neural networks offer the potential to greatly decrease planning time through automation, but the impact of the wide range of hyperparameters to be set during training on model accuracy has not been exhaustively investigated. In the current study, we evaluated the effect of several convolutional neural network architectures and hyperparameters on 2D radiotherapy treatment field delineation. METHODS: Six commonly used deep learning architectures were trained to delineate four-field box apertures on digitally reconstructed radiographs for cervical cancer radiotherapy. A comprehensive search of optimal hyperparameters for all models was conducted by varying the initial learning rate, image normalization methods, and (when appropriate) convolutional kernel size, the number of learnable parameters via network depth and the number of feature maps per convolution, and nonlinear activation functions. This yielded over 1700 unique models, which were all trained until performance converged and then tested on a separate dataset. RESULTS: Of all hyperparameters, the choice of initial learning rate was most consistently significant for improved performance on the test set, with all top-performing models using learning rates of 0.0001. The optimal image normalization was not consistent across architectures. High overlap (mean Dice similarity coefficient = 0.98) and surface distance agreement (mean surface distance < 2 mm) were achieved between the treatment field apertures for all architectures using the identified best hyperparameters. Overlap Dice similarity coefficient (DSC) and distance metrics (mean surface distance and Hausdorff distance) indicated that DeepLabv3+ and D-LinkNet architectures were least sensitive to initial hyperparameter selection. CONCLUSION: DeepLabv3+ and D-LinkNet are most robust to initial hyperparameter selection. Learning rate, nonlinear activation function, and kernel size are also important hyperparameters for improving performance.


Assuntos
Aprendizado Profundo , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Redes Neurais de Computação , Algoritmos , Tomografia Computadorizada por Raios X , Processamento de Imagem Assistida por Computador/métodos
17.
Phys Med Biol ; 68(20)2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37714187

RESUMO

External beam radiation therapy (EBRT) of liver cancers can cause local liver atrophy as a result of tissue damage or hypertrophy as a result of liver regeneration. Predicting those volumetric changes would enable new strategies for liver function preservation during treatment planning. However, understanding of the spatial dose/volume relationship is still limited. This study leverages the use of deep learning-based segmentation and biomechanical deformable image registration (DIR) to analyze and predict this relationship. Pre- and Post-EBRT imaging data were collected for 100 patients treated for hepatocellular carcinomas, cholangiocarcinoma or CRC with intensity-modulated radiotherapy (IMRT) with prescription doses ranging from 50 to 100 Gy delivered in 10-28 fractions. For each patient, DIR between the portal and venous (PV) phase of a diagnostic computed tomography (CT) scan acquired before radiation therapy (RT) planning, and a PV phase of a diagnostic CT scan acquired after the end of RT (on average 147 ± 36 d) was performed to calculate Jacobian maps representing volume changes in the liver. These volume change maps were used: (i): to analyze the dose/volume relationship in the whole liver and individual Couinaud's segments; and (ii): to investigate the use of deep-learning to predict a Jacobian map solely based on the pre-RT diagnostic CT and planned dose distribution. Moderate correlations between mean equivalent dose in 2 Gy fractions (EQD2) and volume change was observed for all liver sub-regions analyzed individually with Pearson correlationrranging from -0.36 to -067. The predicted volume change maps showed a significantly stronger voxel-wise correlation with the DIR-based volume change maps than when considering the original EQD2 distribution (0.63 ± 0.24 versus 0.55 ± 23, respectively), demonstrating the ability of the proposed approach to establish complex relationships between planned dose and liver volume response months after treatment, which represents a promising prediction tool for the development of future adaptive and personalized liver radiation therapy strategies.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Dosagem Radioterapêutica , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada de Feixe Cônico/métodos
18.
Cardiovasc Intervent Radiol ; 46(12): 1748-1754, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37563313

RESUMO

PURPOSE: This study aims to evaluate the technical efficacy and local tumor progression-free survival (LTPFS) of a standardized workflow for thermal ablation of colorectal liver metastases (CRLM) consisting of CT during hepatic arteriography (CTHA)-based imaging analysis, stereotactic thermal ablation, and computer-based software assessment of ablation margins. MATERIALS AND METHODS: This investigator initiated, single-center, single-arm prospective trial will enroll up to 50 patients (≤ 5 CRLM, Measuring ≤ 5 cm). Procedures will be performed in an angio-CT suite under general anesthesia. The primary objective is to estimate LTPFS with a follow-up of up to 2 years and secondary objectives are analysis of the impact of minimal ablative margins on LTPFS, adverse events, contrast media utilization and radiation exposure, overall oncological outcomes, and anesthesia/procedural time. Adverse events (AE) will be recorded by CTCAE (Common Toxicity Criteria for Adverse Events), and Bayesian optimal phase-2 design will be applied for major intraprocedural AE stop boundaries. The institutional CRLM ablation registry will be used as benchmark for comparative analysis with the historical cohort. DISCUSSION: The STEREOLAB trial will introduce a high-precision and standardized thermal ablation workflow for CRLM consisting of CT during hepatic arteriography imaging, stereotactic guidance, and ablation confirmation. Trial Registration ClinicalTrials.gov identifier: (NCT05361551).


Assuntos
Ablação por Cateter , Neoplasias Colorretais , Neoplasias Hepáticas , Humanos , Angiografia , Teorema de Bayes , Ablação por Cateter/métodos , Neoplasias Colorretais/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Neoplasias Hepáticas/patologia , Estudos Prospectivos , Estudos Retrospectivos , Software , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
19.
Brachytherapy ; 22(6): 736-745, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37612174

RESUMO

PURPOSE: To determine the feasibility of quantitative apparent diffusion coefficient (ADC) acquisition during magnetic resonance imaging-guided brachytherapy (MRgBT) using reduced field-of-view (rFOV) diffusion-weighted imaging (DWI). METHODS AND MATERIALS: T2-weighted (T2w) MR and full-FOV single-shot echo planar (ssEPI) DWI were acquired in 7 patients with cervical or vaginal malignancy at baseline and prior to brachytherapy, while rFOV-DWI was acquired during MRgBT following brachytherapy applicator placement. The gross target volume (GTV) was contoured on the T2w images and registered to the ADC map. Voxels at the GTV's maximum Maurer distance comprised a central sub-volume (GTVcenter). Contour ADC mean and standard deviation were compared between timepoints using repeated measures ANOVA. RESULTS: ssEPI-DWI mean ADC increased between baseline and prebrachytherapy from 1.03 ± 0.18 10-3 mm2/s to 1.34 ± 0.28 10-3 mm2/s for the GTV (p = 0.06) and from 0.84 ± 0.13 10-3 mm2/s to 1.26 ± 0.25 10-3 mm2/s at the level of the GTVcenter (p = 0.03), consistent with early treatment response. rFOV-DWI during MRgBT demonstrated mean ADC values of 1.28 ± 0.14 10-3 mm2/s and 1.28 ± 0.19 10-3 mm2/s for the GTV and GTVcenter, respectively (p = 0.02 and p = 0.03 relative to baseline). No significant differences were observed between ssEPI-DWI and rFOV-DWI ADC measurements. CONCLUSIONS: Quantitative ADC measurement in the setting of MRI guided brachytherapy implant placement for cervical and vaginal cancers is feasible using rFOV-DWI, with comparable mean ADC comparable to prebrachytherapy ssEPI-DWI, and may enable MRI-guided radiotherapy targeting of low ADC, radiation resistant sub-volumes of tumor.


Assuntos
Braquiterapia , Neoplasias Vaginais , Feminino , Humanos , Neoplasias Vaginais/diagnóstico por imagem , Neoplasias Vaginais/radioterapia , Braquiterapia/métodos , Estudos de Viabilidade , Imagem de Difusão por Ressonância Magnética/métodos , Reprodutibilidade dos Testes
20.
Radiology ; 308(1): e230146, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37462500

RESUMO

Since its inception in the early 20th century, interventional radiology (IR) has evolved tremendously and is now a distinct clinical discipline with its own training pathway. The arsenal of modalities at work in IR includes x-ray radiography and fluoroscopy, CT, MRI, US, and molecular and multimodality imaging within hybrid interventional environments. This article briefly reviews the major developments in imaging technology in IR over the past century, summarizes technologies now representative of the standard of care, and reflects on emerging advances in imaging technology that could shape the field in the century ahead. The role of emergent imaging technologies in enabling high-precision interventions is also briefly reviewed, including image-guided ablative therapies.


Assuntos
Imageamento por Ressonância Magnética , Radiologia Intervencionista , Humanos , Radiologia Intervencionista/métodos , Radiografia , Fluoroscopia/métodos , Imagem Multimodal , Radiografia Intervencionista/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA