Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
1.
Phys Med ; 57: 231-237, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30545736

RESUMO

PURPOSE: To develop and apply a stepping approach for the validation of Knowledge-based (KB) models for planning optimization: the method was applied to the case of concomitant irradiation of pelvic nodes and prostate + seminal-vesicles bed irradiation in post-prostatectomy patients. METHODS: The clinical VMAT plans of 52 patients optimized by two reference planners were selected to generate a KB-model (RapidPlan, v.13.5 Varian). A stepping-validation approach was followed by comparing KB-generated plans (with and without planner-interaction, RP and only-RP respectively) against delivered clinical plans (RA). The validation followed three steps, gradually extending its generalization: 20 patients used to develop the model (closed-loop); 20 new patients, same planners (open-loop); 20 new patients, different planners (wide-loop). All plans were compared, in terms of relevant dose-volume parameters and generalized equivalent uniform dose (gEUD). RESULTS: KB-plans were generally better than or equivalent to clinical plans. For RPvsRA, PTVs coverage was comparable, for OARs RP was always better. Comparing only-RPvsRA, PTVs coverage was always better; bowel\bladder V50Gy and D1%, bowel\bladder\rectum Dmean, femoral heads V40Gy and penile bulb V50Gy were significantly improved. For RPvsRA gEUD reduction >1 Gy was seen in 80% of plans for rectum, bladder and bowel; for only-RPvsRA, this was found in 50% for rectum/bladder and in 70% for bowel. CONCLUSION: An extensive stepping validation approach of KB-model for planning optimization showed better or equal performances of automatically generated KB-plan compared to clinical plans. The interaction of a planner further improved planning performances.


Assuntos
Modelos Teóricos , Planejamento da Radioterapia Assistida por Computador/métodos , Automação
2.
Eur J Nucl Med Mol Imaging ; 45(12): 2071-2078, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29876617

RESUMO

PURPOSE: The value of FDG PET-derived parameters in predicting overall survival (OS), local relapse-free survival (LRFS) and distant relapse-free survival (DRFS) in treated patients with malignant pleural mesothelioma (MPM) was evaluated. METHODS: This retrospective evaluation included 55 MPM patients treated between March 2006 and February 2015 with FDG PET/CT-guided salvage helical tomotherapy (HTT) after previous surgery plus chemotherapy. Univariate Cox regression analysis was performed to assess the impact of the following FDG PET-derived parameters: biological target volume (BTV), mean and maximum standardized uptake values (SUVmean/max), metabolic tumour volume (MTV) and total lesion glycolysis (TLG), measured using different uptake thresholds (40%, 50% and 60%). Logistic regression was then performed to identify the best FDG PET-derived parameters for selecting patients with poorer survival. RESULTS: The median OS was 9.1 months (range 0.0 - 69.6 months) after the end of HTT; 54/55 patients were dead at the last follow-up. BTV and TLG40, TLG50 and TLG60 were the most significant predictors of OS (p < 0.005). The median OS was 4.8 months in patients with MTV60 >5 cm3 and TLG40 >334.4, compared with 13.8 months and 16.1 months in patients with smaller values, respectively. The median LRFS and DRFS were 6.2 months (range 1.2 - 39.4 months) and 6.5 months (0.0 - 66.4 months), respectively. TLG40, TLG50 and TLG60 were significantly correlated with LRFS (p < 0.015). Median DRFS was 6.4 months in patients with MTV40 >39.6 cm3 and 6.2 months in patients with TLG40 >334.4, compared with 17 months and 18.8 months in patients with smaller values. BTV, TLG40 and MTV40 were also found to be good predictors in patients with poor OS/LRFS/DRFS (median survival times less than the median values). CONCLUSION: FDG PET-derived parameters effectively discriminated patients with a poor prognosis and may be helpful in the selection of MPM patients for salvage HTT.


Assuntos
Neoplasias Pulmonares/diagnóstico por imagem , Mesotelioma/diagnóstico por imagem , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/terapia , Masculino , Mesotelioma/patologia , Mesotelioma/terapia , Mesotelioma Maligno , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Valor Preditivo dos Testes , Compostos Radiofarmacêuticos
3.
Phys Med ; 50: 66-74, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29891096

RESUMO

PURPOSE: The analysis of PET images by textural features, also known as radiomics, shows promising results in tumor characterization. However, radiomic metrics (RMs) analysis is currently not standardized and the impact of the whole processing chain still needs deep investigation. We characterized the impact on RM values of: i) two discretization methods, ii) acquisition statistics, and iii) reconstruction algorithm. The influence of tumor volume and standardized-uptake-value (SUV) on RM was also investigated. METHODS: The Chang-Gung-Image-Texture-Analysis (CGITA) software was used to calculate 39 RMs using phantom data. Thirty noise realizations were acquired to measure statistical effect size indicators for each RM. The parameter η2 (fraction of variance explained by the nuisance factor) was used to assess the effect of categorical variables, considering η2 < 20% and 20% < η2 < 40% as representative of a "negligible" and a "small" dependence respectively. The Cohen's d was used as discriminatory power to quantify the separation of two distributions. RESULTS: We found the discretization method based on fixed-bin-number (FBN) to outperform the one based on fixed-bin-size in units of SUV (FBS), as the latter shows a higher SUV dependence, with 30 RMs showing η2 > 20%. FBN was also less influenced by the acquisition and reconstruction setup:with FBN 37 RMs had η2 < 40%, only 20 with FBS. Most RMs showed a good discriminatory power among heterogeneous PET signals (for FBN: 29 out of 39 RMs with d > 3). CONCLUSIONS: For RMs analysis, FBN should be preferred. A group of 21 RMs was suggested for PET radiomics analysis.


Assuntos
Processamento de Imagem Assistida por Computador/instrumentação , Reconhecimento Automatizado de Padrão , Imagens de Fantasmas , Tomografia por Emissão de Pósitrons , Software
4.
Phys Med ; 39: 73-79, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28619289

RESUMO

PURPOSE: The aim of this study was to test the feasibility and dosimetric accuracy of a method that employs planning CT-to-MVCT deformable image registration (DIR) for calculation of the daily dose for head and neck (HN) patients treated with Helical Tomotherapy (HT). METHODS: For each patient, the planning kVCT (CTplan) was deformably registered to the MVCT acquired at the 15th therapy session (MV15) with a B-Spline Free Form algorithm using Mattes mutual information (open-source software 3D Slicer), resulting in a deformed CT (CTdef). On the same day as MVCT15, a kVCT was acquired with the patient in the same treatment position (CT15). The original HT plans were recalculated both on CTdef and CT15, and the corresponding dose distributions were compared; local dose differences <2% of the prescribed dose (DD2%) and 2D/3D gamma-index values (2%-2mm) were assessed respectively with Mapcheck SNC Patient software (Sun Nuclear) and with 3D-Slicer. RESULTS: On average, 87.9%±1.2% of voxels were found for DD2% (on average 27 slices available for each patient) and 94.6%±0.8% of points passed the 2D gamma analysis test while the 3D gamma test was satisfied in 94.8%±0.8% of body's voxels. CONCLUSIONS: This study represents the first demonstration of the dosimetric accuracy of kVCT-to-MVCT DIR for dose of the day computations. The suggested method is sufficiently fast and reliable to be used for daily delivered dose evaluations in clinical strategies for adaptive Tomotherapy of HN cancer.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Tomografia Computadorizada por Raios X , Algoritmos , Cabeça , Humanos , Pescoço , Radiometria , Software
5.
Clin Oncol (R Coll Radiol) ; 28(8): 490-500, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26961088

RESUMO

AIMS: To report 5 year outcome and late toxicity in prostate cancer patients treated with image-guided tomotherapy with a moderate hypofractionated simultaneous integrated boost approach. MATERIALS AND METHODS: In total, 211 prostate cancer patients, 78 low risk, 53 intermediate risk and 80 high risk were treated between 2005 and 2011. Intermediate- and high-risk patients received 51.8 Gy to pelvic lymph nodes and concomitant simultaneous integrated boost to prostate up to 74.2 Gy/28 fractions, whereas low-risk patients were treated to the prostate only with 71.4 Gy/28 fractions. Daily megavoltage computed tomography (MVCT) image guidance was applied. Androgen deprivation was prescribed for a median duration of 6 months for low-risk patients (for downsizing), 12 months for intermediate-risk and 36 months for high-risk patients. The 5 year biochemical relapse-free survival (bRFS), cancer-specific survival (CSS), overall survival and late gastrointestinal and genitourinary CTCAE.v3 toxicity were assessed. The effect of several clinical variables on both outcome and gastrointestinal/genitourinary toxicity was tested by uni- and multivariate Cox regression analyses. RESULTS: After a median follow-up of 5 years, the late toxicity actuarial incidence was: genitourinary ≥ grade 2: 20.2%; genitourinary ≥ grade 3: 5.9%; gastrointestinal ≥ grade 2: 17%; gastrointestinal ≥ grade 3: 6.3% with lower prevalence at the last follow-up visit (≥ grade 3: genitourinary: 1.9%; gastrointestinal: 1.9%). Major predictors of ≥ grade 3 genitourinary and gastrointestinal late toxicity were genitourinary acute toxicity ≥ grade 2 (hazard ratio: 4.9) and previous surgery (hazard ratio: 3.4). The overall 5 year bRFS was 93.7% (low risk: 94.6%; intermediate risk: 96.2%; high risk: 91.1%), overall survival and CSS were 88.6% (low risk: 90.5%; intermediate risk: 87.4%; high risk: 87%) and 97.5% (low risk: 98.7%; intermediate risk: 95%; high risk: 94.3%), respectively. Risk classes and androgen deprivation were not significantly correlated with either bRFS, overall survival or CSS. Twelve patients experienced a biochemical relapse but none experienced clinically proven local and/or pelvic recurrence. CONCLUSION: A satisfactory 5 year outcome with an acceptable toxicity profile was observed. The combination of image-guided radiotherapy-intensity-modulated radiotherapy, high equivalent 2 Gy dose (EQD2) with a moderate hypofractionated approach and extensive prophylactic lymph node irradiation also leads to very good outcome in high-risk patients.


Assuntos
Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Idoso , Idoso de 80 Anos ou mais , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias da Próstata/mortalidade , Hipofracionamento da Dose de Radiação , Radioterapia Guiada por Imagem/efeitos adversos , Resultado do Tratamento
6.
Artigo em Inglês | MEDLINE | ID: mdl-26737226

RESUMO

A novel approach for three-dimensional (3D) surface reconstruction of anatomical structures in radiotherapy (RT) is presented. This is obtained from manual cross-sectional contours by combining both image voxel segmentation processing and implicit surface streaming methods using wavelets. 3D meshes reconstructed with the proposed approach are compared to those obtained from traditional triangulation algorithm. Qualitative and quantitative evaluations are performed in terms of mesh quality metrics. Differences in smoothness, detail and accuracy are observed in the comparison, considering three different anatomical districts and several organs at risk in radiotherapy. Overall best performances were recorded for the proposed approach, regardless the complexity of the anatomical structure. This demonstrates the efficacy of the proposed approach for the 3D surface reconstruction in radiotherapy and allows for further specific image analyses using real biomedical data.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Algoritmos , Processamento Eletrônico de Dados , Humanos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Tomografia Computadorizada por Raios X/métodos , Análise de Ondaletas
7.
Technol Cancer Res Treat ; 14(6): 683-91, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24945374

RESUMO

The Jacobian of the deformation field of the registration between images taken during Radiotherapy is a measure of compression/expansion of the voxels within an organ. The Jacobian mean value was applied to investigate possible correlations between parotid deformation and anatomical, clinical and dosimetric parameters. Data of 84 patients were analyzed. Parotid deformation was evaluated through Jacobian maps of images taken at the start and at the end of the treatment. Several clinical, geometrical and dosimetric factors were considered. Correlation between Jacobian mean value and these parameters was assessed through Spearman's test. Univariate and multivariate logistic analyses were performed by considering as the end point the first quartile value of the Jacobian mean value. Parotid dose volume histograms were stratified according to gland deformation, assessing the most predictive dose-volume combination. At multivariate analysis, age (p = 0.02), overlap between tumor volume and parotid gland (p = 0.0006) and the parotid volume receiving more than 10 Gy (p = 0.02) were found as the best independent predictors, by considering Jacobian mean value fist quartile, the parotid volume receiving more than 10 Gy and 40 Gy were found as the most predictive dosimetric parameters. Parotid glands were divided in three different sub-groups (bad-, medium- and good dose volume histogram). The risk to have Jacobian means value lower than first quartile was 39.6% versus 19.6% versus 11.3% in these three groups. By including in the multivariate analysis this "dose volume grouping" parameter, age and bad dose volume histogram were found as the most predictive parameters for large shrinkage. The pattern of parotid deformation may be well predicted by some pre-treatment variables; a bad dose volume histogram seems the most important predictor.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Interpretação de Imagem Assistida por Computador/métodos , Glândula Parótida/efeitos da radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Radioterapia de Intensidade Modulada
8.
Phys Med Biol ; 56(3): 775-91, 2011 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-21239848

RESUMO

We developed an efficient technique to auto-propagate parotid gland contours from planning kVCT to daily MVCT images of head-and-neck cancer patients treated with helical tomotherapy. The method deformed a 3D surface mesh constructed from manual kVCT contours by B-spline free-form deformation to generate optimal and smooth contours. Deformation was calculated by elastic image registration between kVCT and MVCT images. Data from ten head-and-neck cancer patients were considered and manual contours by three observers were included in both kVCT and MVCT images. A preliminary inter-observer variability analysis demonstrated the importance of contour propagation in tomotherapy application: a high variability was reported in MVCT parotid volume estimation (p = 0.0176, ANOVA test) and a larger uncertainty of MVCT contouring compared with kVCT was demonstrated by DICE and volume variability indices (Wilcoxon signed rank test, p < 10(-4) for both indices). The performance analysis of our method showed no significant differences between automatic and manual contours in terms of volumes (p > 0.05, in a multiple comparison Tukey test), center-of-mass distances (p = 0.3043, ANOVA test), DICE values (p = 0.1672, Wilcoxon signed rank test) and average and maximum symmetric distances (p = 0.2043, p = 0.8228 Wilcoxon signed rank tests). Results suggested that our contour propagation method could successfully substitute human contouring on MVCT images.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Glândula Parótida/diagnóstico por imagem , Radioterapia Assistida por Computador/métodos , Automação , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Variações Dependentes do Observador , Tomografia Computadorizada por Raios X
9.
Br J Radiol ; 75(900): 974-81, 2002 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-12515706

RESUMO

The aim of the present study is to compare the calculated midline dose map with the in vivo measured midline dose map, using portal detectors in conjunction with a pair of diodes. Measurements were performed in 10 patients treated for head/neck cancer and irradiated with lateral opposed 6 MV X-ray beams. The relative exit dose map, derived from transmission dose data of a portal film combined with the absolute entrance/exit dose measured by the diodes, can be used to derive the corresponding midline dose map by applying appropriate algorithms. Midplane dose values were estimated in eight relevant anatomic positions and compared with the corresponding calculated values with our three-dimensional (3D) treatment planning system using two-dimensional (2D) (Batho) and 3D (ETAR) inhomogeneity correction algorithms. In vivo estimated midplane doses agree within +/-3.5% relative to treatment planning calculations in 89 of 116 measurements points, with only 4 of 116 points outside +/-5%. A variation between measured and calculated dose can be found according to anatomical location. For air inhomogeneity, mean deviations were +2.2% (1 standard deviation (SD) approximately 1.7%) for both Batho and ETAR algorithms; for bone structures, mean deviations were approximately -0.6% (1 SD approximately 2.7%) for both algorithms. The worst agreement was found in the anterior neck where the mean deviation between measured and calculated midline dose was +3.1% (1 SD=1.4%) and +3.4% (1 SD= 2%) using Batho and ETAR, respectively. Sufficiently accurate 2D midplane dose maps may be simply obtained in vivo in the irradiation of head/neck cancer by using a portal detector in combination with a pair of diodes, in order to verify the dose actually delivered during treatment.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Radiometria/métodos , Algoritmos , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional/métodos , Radioterapia de Alta Energia/métodos
10.
Neurol Sci ; 22(1): 85-6, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11487214

RESUMO

Although deep brain stimulation (DBS) is a clinically effective therapy for patients with advanced Parkinson's disease (PD), its physiological effects on the brain and possible actions on non-motor functional systems remain largely unknown. This study evaluated the effects of DBS of the subthalamic nucleus (STN) on neurophysiological variables and on cardiovascular physiology. Nine patients affected by PD undergoing chronic DBS of the STN have been studied. We performed electroencephalography (EEG), somatosensory (SEPs) and visual evoked potentials (VEPs), exteroceptive masseteric silent period and sympathetic skin response (SSR) studies with DBS ON and OFF. To assess the effects of stimulation on the cardiovascular system the tilt test and plasma renin activity were studied. When we turned the DBS OFF, both SEP N20 and the VEP P100 component increased significantly in amplitude whereas the SSR decreased in amplitude and increased in latency. Although plasma renin activity tended to increase with DBS OFF, its modification induced by postural changes and blood pressure values did not significantly differ with DBS ON and OFF. We conclude that DBS of the STN in PD, besides inducing a clinical improvement, induces several non-motor effects.


Assuntos
Terapia por Estimulação Elétrica/efeitos adversos , Doença de Parkinson/fisiopatologia , Doença de Parkinson/terapia , Núcleo Subtalâmico/fisiopatologia , Vias Aferentes/fisiopatologia , Idoso , Pressão Sanguínea/fisiologia , Tronco Encefálico/fisiopatologia , Córtex Cerebral/fisiopatologia , Eletrodos Implantados , Eletroencefalografia , Potenciais Evocados/fisiologia , Humanos , Interneurônios/fisiologia , Músculo Masseter/fisiopatologia , Pessoa de Meia-Idade , Condução Nervosa/fisiologia , Doença de Parkinson/patologia , Tempo de Reação/fisiologia , Núcleo Subtalâmico/patologia , Sistema Nervoso Simpático/fisiopatologia
11.
Radiother Oncol ; 58(2): 169-78, 2001 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-11166868

RESUMO

INTRODUCTION: This work investigates the possibility of using a pair of diodes on the beam axis in conjunction with a portal imaging detector to estimate in vivo midline dose distributions, without any additional patient information, related to the external body contour. MATERIALS AND METHODS: In the proposed method, the patient is considered equivalent to a parallelepiped phantom with a thickness z equal to the patient's physical thickness on the field axis with a variable electronic density rho, depending on the water-equivalent thickness. Based on this assumption, if the air gap between portal detector and patient is kept small (within 10-15 cm), the relative exit dose map may be assumed to be equal to the corresponding map measured at the portal detector level by geometrical back projection to the corresponding exit points. The relative exit dose map is then normalized at the on-axis value measured by the exit diode. The entrance dose map is derived by correcting the absolute dose value measured with the diode at the entrance surface by the off-axis ratios. For each pair of entrance and exit doses, the midline dose may be estimated by applying algorithms reported in literature. The method was tested in 6 MV beams using portal film as detector and the Huyskens and Rizzotti algorithms for midline dose estimation. Tests on homogeneous cubic phantoms, homogeneous phantoms with varying thickness symmetrically (simulating head and neck regions) and asymmetrically (simulating abdomen/pelvis region), and a half-sphere phantom with simulating the breast, were performed. Midline doses estimated with the proposed method have been compared with corresponding ones measured by ionisation chamber. RESULTS AND DISCUSSION: Results confirm that the proposed method can be used to estimate midplane dose maps within 2-3% for most clinically suitable situations. For homogeneous symmetrical phantoms the agreement between estimated and measured midline doses decreases with the phantom-portal film distance, the field sizes and the thickness. For homogeneous asymmetrical phantoms the percentage deviations are generally within 3%. Discrepancies larger than 3% (up to 5-6%) are found only for "stressed" irradiation geometries which are not linked with any clinical condition. CONCLUSIONS: The obtained results not only show the accuracy of the proposed method but, due to its simplicity, suggest a rapid clinical implementation of this method in relevant clinical situations such as head-neck, breast and abdomen/pelvis irradiation. Previous investigations which confirmed the possibility of using portal detectors for transit dosimetry in inhomogeneous regions suggest the further exploration of the accuracy and the limits of the proposed method in such cases.


Assuntos
Eletrônica/instrumentação , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação , Radioterapia Conformacional/instrumentação , Abdome/efeitos da radiação , Algoritmos , Mama/efeitos da radiação , Feminino , Cabeça/efeitos da radiação , Humanos , Pescoço/efeitos da radiação , Pelve/efeitos da radiação , Imagens de Fantasmas , Radioterapia de Alta Energia , Propriedades de Superfície
12.
Radiother Oncol ; 56(1): 85-95, 2000 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-10869759

RESUMO

BACKGROUND: In vivo dosimetry is widely considered to be an important tool for quality assurance in external radiotherapy. INTRODUCTION: In this study we report on our experience over more than 4 years in systematic in vivo dosimetry with diodes. MATERIALS AND METHODS: From November '94 an in vivo entrance dosimetry check was performed for every new patient irradiated at one of our treatment units (Linac 6/100, 6 MV X-rays). Diodes were calibrated in terms of entrance dose; appropriate correction factors had been previously assessed (taking SSDs, field width, wedge, oblique incidence and blocking tray into account) and were individually applied to in vivo diode readings. The in vivo measured entrance dose was compared with the expected one, with a 5% action level; if a larger deviation was found, all treatment parameters were verified, and the in vivo dosimetry check was repeated. During the period November '94-May '99, 2824 measurements on 1433 patients were collected. RESULTS: Nine out of 1433 (0.63%) serious systematic errors (leading to a 5% or more on the delivered dose to the PTV) were detected by in vivo dosimetry; four out of nine would produce a 10% or more error if not detected. The rate of serious systematic errors detected by an independent check of treatment chart and MU calculation was found to be 1.5%, showing that less than 1/3 of the errors escapes this check. One hundred and twelve out of 1433 (7.8%) patients had more than one check: the rate of second checks was significantly higher for breast patients (31/250, 12.4%) against non-breast patients (81/1183, 6.8%, P=0.003). A number of patients demonstrated a persistent relatively large error even after two or more checks. For almost all patients the cause of the deviation was assessed; the most frequent cause was the difficulty in correctly positioning the patient and/or the diode. When analyzing the distribution of the deviations between measured and expected entrance doses (excluding first checks in the case of repetition of the in vivo dosimetry control) the mean deviation was 0.4% with a standard deviation equal to 3.0%. The rates of deviations larger than 5 and 7% were 9.9 and 2.6%, respectively. When considering the same data taking the average deviation in the case of opposed beams, the SD became 2.6% and the rates of deviations larger than 5 and 7%, respectively, 5.2 and 0.8%. When dividing the beams according to their orientation, significantly higher rates of large deviations (>5 and 7%) were found for oblique and posterior-anterior (PA) fields against lateral and anterior-posterior (AP) fields (P<0.05). Similarly, higher rates of large deviations were found for wedged fields against unwedged fields (P<0.03) and for blocked fields against unblocked fields (P<0.01). When dividing the data according to the anatomical district, accuracy was worse for breast (mean deviation 0.1%, 1 SD: 3.5%) and neck AP-PA fields (mean deviation 1%, 1 SD: 3,4%). Better accuracy was found for vertebrae (0.1%, 1 SD 2. 1%) and brain patients (-0.7%, 1 SD: 2.6%). During the considered period, in vivo dosimetry was also able to promptly detect a systematic error caused by a wrong resetting of the simulator height couch indicator, with a consequent error in the estimate of patient thickness of about 4 cm. CONCLUSIONS: In our experience, systematic in vivo dosimetry demonstrated to be a valid tool for quality assurance, both in detecting systematic errors which may escape the data transfer/MU calculation check and in giving an effective way of estimating the accuracy of treatment delivery.


Assuntos
Dosagem Radioterapêutica/normas , Estudos de Coortes , Humanos , Controle de Qualidade , Doses de Radiação , Radioterapia/normas
13.
Radiother Oncol ; 55(1): 49-58, 2000 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-10788688

RESUMO

BACKGROUND: In the case of concave-shaped PTVs including prostate (P) and seminal vesicles (SV), intensity-modulated radiation therapy (IMRT) should improve the therapeutic ratio of the treatment of prostate cancer. PURPOSE: Comparing IMRT by simple 1D modulations with conventional 3D conformal therapy (i.e. non-IMRT) in the treatment of concave-shaped PTVs including P+SV. MATERIALS AND METHODS: For five patients having a concave-shaped PTV (P+SV) previously treated at our Institute with conformal radiotherapy, conventional 3- and 4-fields conformal plans were compared with IMRT plans in terms of biological indices. IMRT plans were generated by using five equi-spaced beams with a partial shielding of the rectum obtainable with our single-absorber modulation technique (Fiorino C, Lev A, Fusca M, Cattaneo GM, Rudello F, Calandrino R. Dynamic beam modulation by using a single dynamic absorber. Phys. Med. Biol. 1995;40:221-240). The modulation was one-dimensional and the shape of the beams was at single minimum in correspondence with the 'core' of the rectum; the beam intensity in the minimum was set equal to 20 or 40% of the open beam intensity. All plans were simulated on the CADPLAN TPS using a pencil-beam based algorithm (with 18 MV X-rays). Tumour control probability (TCP) and normal tissue complication probabilities (NTCPs) (for rectum, bladder and femoral head) were calculated for all situations when varying the isocentre dose from 60 to 90 Gy. Dose distributions were corrected taking dose fractionation into account through the linear-quadratic model; for the TCP/NTCP estimations the Webb-Nahum and the Lyman-Kutcher models were respectively applied. Three different scores were considered: (a) increase of TCP while keeping rectum NTCP equal to 5% (TCP(5%)); (b) increase of the uncomplicated tumour control probability (P+); (c) increase of the biological-based scoring function (S+), developed by Mohan et al. (Mohan R, Mageras GS, Baldwin B, Clinically relevant optimization of 3D conformal treatments. Med. Phys. 1992;19:933-944). The impact of the uncertainty in the knowledge of the parameters of the biological models was investigated for TCP(5%). RESULTS: (a) The average gain in TCP(5%) when considering IMRT against non-IMRT conformal plans was 7.3% (range 5.0-13.5%); (b) the average increase of P+ was 3.4% (range: 1. 0-8.5%); and (c) the average increase of S+ was 5.4% (range 2.9-12. 4%). The largest gain was found for one patient (patient 5) showing a significantly larger overlapping between PTV and rectum. CONCLUSIONS: Simple 1D-IMRT may clearly improve the therapeutic ratio in the treatment of concave-shaped PTVs including P and SV. In the range of clinically suitable values, the impact of the uncertainty of the parameters n and sigma(alpha) does not significantly alter the main results concerning the gain in TCP(5%). The reported gain in terms of P+ and S+ should be considered with great caution because of the intrinsic uncertainties of the model's parameters and, for bladder, because the 'true' DVH (considering variations of the shape and dimension due to variable filling) may be very different from the DVH calculated on a single CT scan. Further investigations should consider inversely-optimised 1D and 2D-IMRT plan in order to compare them in terms of cost-benefit.


Assuntos
Próstata/efeitos da radiação , Neoplasias da Próstata/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia Conformacional , Glândulas Seminais/efeitos da radiação , Algoritmos , Simulação por Computador , Análise Custo-Benefício , Fracionamento da Dose de Radiação , Cabeça do Fêmur/efeitos da radiação , Humanos , Modelos Lineares , Masculino , Modelos Biológicos , Proteção Radiológica , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/economia , Radioterapia de Alta Energia , Reto/efeitos da radiação , Bexiga Urinária/efeitos da radiação
14.
Phys Med Biol ; 44(11): N233-41, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10588290

RESUMO

Dynamic modulation can be affected by inaccuracies when the required acceleration is larger than the highest allowed by the mechanical characteristics of the whole apparatus. In this study, inertia effects have been investigated with regard to the single absorber 1D modulation, analysing primarily how the acceleration performed by the modulating system affects the realization of 'single absorber' fluence profiles and the type of correction which could be devised. The observed percentage deviations from desired modulation at the lowest fluence coordinate of single minimum fluence profiles, when no correction is applied, were almost negligible for 'easy' modulations of the incident fluence (i.e. slow gradients); deviations became increasingly relevant as the moving absorber executed steeper gradients (a 17.6% higher dose being delivered in the minimum position when a 0.2 modulation is required). By applying the proposed corrections, the single absorber performances were improved to a satisfactory level, with a maximum deviation from desired modulation in the minima within 1.6%.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Algoritmos , Modelos Teóricos , Planejamento da Radioterapia Assistida por Computador/instrumentação , Planejamento da Radioterapia Assistida por Computador/métodos
15.
Artigo em Inglês | MEDLINE | ID: mdl-1780696

RESUMO

The casual observation of high serum levels in (TATI) of tumor associated trypsin inhibitor in patients with osteosarcoma inspired us to evaluate the use of this peptide in the diagnosis of various bone diseases. We determined the serum concentrations of TATI in 35 patients with various bone diseases, i.e. degenerative diseases, bone metastasis and osteosarcomas. The cut off, determined as the 99th percentile of TATI serum levels in healthy volunteers was 32 micrograms/l. TATI has a better sensitivity in osteosarcomas (83%) than in metastatic bone diseases (33%). Its specificity in non-malignant bone diseases was not exceptional (82%). This is probably because TATI may also behave as on acute phase protein, the levels of which can rise in non-malignant diseases and also as a result of a tissue reaction in primary bone tumors.


Assuntos
Biomarcadores Tumorais/sangue , Doenças Ósseas/diagnóstico , Neoplasias Ósseas/diagnóstico , Osteossarcoma/diagnóstico , Inibidor da Tripsina Pancreática de Kazal/sangue , Doenças Ósseas/sangue , Neoplasias Ósseas/sangue , Humanos , Osteossarcoma/sangue , Sensibilidade e Especificidade
16.
Ital J Orthop Traumatol ; 16(1): 93-101, 1990 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2380057

RESUMO

Thirty-four patients with painful prosthesetized hips were submitted to arthrography in order to evaluate the correlation between pain and the anatomical situation between the implants and the host bone. By injecting a local anaesthetic together with the contrast medium it was possible to perform functional tests comprising passive movements of the hip and full weightbearing for at least 5 minutes in order to ascertain whether or not the pain persisted. This yielded different results varying from total relief to persistence, depending on the type of mobilisation demonstrated by arthrography. In particular, pain was reduced in cases of mobilisation of the acetabular component, and persisted when mobilisation was in the femoral component. A correlation between functional testing, arthrography and bacteriological examination for possible low grade infection allowed for a closer study of the origin of pain, and more accurate planning of surgery when re-prosthesetization was being considered.


Assuntos
Artrografia/métodos , Articulação do Quadril/diagnóstico por imagem , Prótese de Quadril , Dor/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Falha de Prótese
17.
J Spinal Disord ; 2(4): 254-62, 1989 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-2520083

RESUMO

Sixteen patients affected with metastatic malignant disease of the cervical spine underwent cervical vertebral body replacement with an original metal cementless prosthesis. In all cases there was immediate spine stability postoperatively and pain relief. All patients were able to walk within a few days postoperatively without any rigid external support. Follow-up roentgenograms have shown nonprosthetic mobilization.


Assuntos
Vértebras Cervicais , Metais , Próteses e Implantes , Neoplasias da Coluna Vertebral/cirurgia , Adulto , Idoso , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva Local de Neoplasia , Período Pós-Operatório , Radiografia , Neoplasias da Coluna Vertebral/diagnóstico por imagem , Neoplasias da Coluna Vertebral/secundário
19.
Minerva Med ; 78(22): 1707-10, 1987 Nov 30.
Artigo em Italiano | MEDLINE | ID: mdl-3696448

RESUMO

A rare case of a giant extradural neurinoma of the IV lumbar root with an anterior development and a soft neurological picture is reported. The Authors stress the important role of CT both in the neurinoma diagnosis and in the correct preoperative evaluation of its extension and its relationship with contiguous organs.


Assuntos
Neurilemoma/diagnóstico por imagem , Neoplasias do Sistema Nervoso Periférico/diagnóstico por imagem , Raízes Nervosas Espinhais , Feminino , Humanos , Pessoa de Meia-Idade , Neurilemoma/patologia , Neoplasias do Sistema Nervoso Periférico/patologia , Tomografia Computadorizada por Raios X
20.
Ital J Orthop Traumatol ; 12(3): 295-304, 1986 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-3570749

RESUMO

The basic problem in dealing with metastatic deposits in the cervical spine is to treat the lesion in time, that is, prior to the onset of radicular or medullary involvement. This is always progressive and seriously affects the quality of remaining life in these patients. Early surgical intervention, in fact, makes it possible to free these patients from the prolonged use of orthoses which are often badly tolerated, facilitates easy nursing and often avoids or significantly reduces the pain due to these secondary lesions, so restoring a quality of residual life which is acceptable even in the context of neoplastic disease. After reviewing the world literature and the proposals of various authors, we present our own experience in 28 surgically treated cases. The advantages and disadvantages of the various techniques are discussed. Finally, a flexible metallic cervical prosthesis designed by the authors is presented. This is a shock-absorbent device which is fixed without cement.


Assuntos
Vértebras Cervicais/cirurgia , Neoplasias da Coluna Vertebral/secundário , Adulto , Idoso , Terapia Combinada , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Próteses e Implantes , Fusão Vertebral , Neoplasias da Coluna Vertebral/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA