1.
NMR Biomed ; 34(6): e4493, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33624305

RESUMO

The aim of this work was to improve the SNR efficiency of zero echo time (ZTE) MRI pulse sequences for faster imaging of short-T2 components at large dead-time gaps. ZTE MRI with hybrid filling (HYFI) is a strategy for retrieving inner k-space data missed during the dead-time gaps arising from radio-frequency excitation and switching in ZTE imaging. It performs hybrid filling of the inner k-space with a small single-point-imaging core surrounded by a stack of shells acquired on radial readouts in an onion-like fashion. The exposition of this concept is followed by translation into guidelines for parameter choice and implementation details. The imaging properties and performance of HYFI are studied in simulations as well as phantom, in vitro and in vivo imaging, with an emphasis on comparison with the pointwise encoding time reduction with radial acquisition (PETRA) technique. Simulations predict higher SNR efficiency for HYFI compared with PETRA at preserved image quality, with the advantage increasing with the size of the k-space gap. These results are confirmed by imaging experiments with gap sizes of 25 to 50 Nyquist dwells, in which scan times for similar image quality could be reduced by 25% to 60%. The HYFI technique provides both high SNR efficiency and image quality, thus outperforming previously known ZTE-based pulse sequences, in particular for large k-space gaps. Promising applications include direct imaging of ultrashort-T2 components, such as the myelin bilayer or collagen, T2 mapping of ultrafast relaxing signals, and ZTE imaging with reduced chemical shift artifacts.


Assuntos
Imagem Ecoplanar , Algoritmos , Animais , Osso e Ossos/diagnóstico por imagem , Bovinos , Simulação por Computador , Humanos , Joelho/diagnóstico por imagem , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Fatores de Tempo
2.
Magn Reson Med ; 85(5): 2882-2891, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33433044

RESUMO

PURPOSE: To explore the use of conductive elastomer for MR signal detection and the utility of this approach for wearable detector arrays. METHODS: An elastomer filled with silver microparticles was used to form stretchable radiofrequency coils for MR detection. Their electrical performance in terms of the Qunloaded and Q ratio was assessed in the relaxed state and under repeated strain up to 40%. In a phantom imaging study, the signal-to-noise ratio yield of conductive elastomer coils was compared with that of a reference copper coil. Four elastomer coils were integrated with a stretchable textile substrate to form a wearable array for knee imaging. The array was employed for multiple-angle and kinematic knee imaging in vivo. RESULTS: The elastomer coils proved highly stretchable and mechanically robust. Upon repeated stretching by 20%, a medium-sized coil element settled at Qunloaded of 42 in the relaxed state and 32 at full strain, reflecting sample-noise dominance. The signal-to-noise ratio of elastomer coils was found to be 8% to 16% lower than that achieved with a conventional copper coil. Multiple-angle and kinematic knee imaging with the wearable array yielded high-quality results indicating robustness of detection performance against stretching and warping of the array. CONCLUSION: Conductive elastomer is a viable material for MR detection. Coils made from this material reconcile high stretchability and adequate electrical performance with ease of manufacturing. Conductive elastomer also offers inherent restoring forces and is readily washable and sanitizable, making it an excellent basis of wearable detector front ends.


Assuntos
Elastômeros , Dispositivos Eletrônicos Vestíveis , Condutividade Elétrica , Imagens de Fantasmas , Razão Sinal-Ruído
3.
Magn Reson Med ; 85(4): 1924-1937, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33280160

RESUMO

PURPOSE: Spiral readouts combine several favorable properties that promise superior net sensitivity for diffusion imaging. The purpose of this study is to verify the signal-to-noise ratio (SNR) benefit of spiral acquisition in comparison with current echo-planar imaging (EPI) schemes. METHODS: Diffusion-weighted in vivo brain data from three subjects were acquired with a single-shot spiral sequence and several variants of single-shot EPI, including full-Fourier and partial-Fourier readouts as well as different diffusion-encoding schemes. Image reconstruction was based on an expanded signal model including field dynamics obtained by concurrent field monitoring. The effective resolution of each sequence was matched to that of full-Fourier EPI with 1 mm nominal resolution. SNR maps were generated by determining the noise statistics of the raw data and analyzing the propagation of equivalent synthetic noise through image reconstruction. Using the same approach, maps of noise amplification due to parallel imaging (g-factor) were calculated for different acceleration factors. RESULTS: Relative to full-Fourier EPI at b = 0 s/mm2 , spiral acquisition yielded SNR gains of 42-88% and 40-89% in white and gray matter, respectively, depending on the diffusion-encoding scheme. Relative to partial-Fourier EPI, the gains were 36-44% and 34-42%. Spiral g-factor maps exhibited less spatial variation and lower maxima than their EPI counterparts. CONCLUSION: Spiral readouts achieve significant SNR gains in the order of 40-80% over EPI in diffusion imaging at 3T. Combining systematic effects of shorter echo time, readout efficiency, and favorable g-factor behavior, similar benefits are expected across clinical and neurosciences uses of diffusion imaging.


Assuntos
Imagem de Difusão por Ressonância Magnética , Imagem Ecoplanar , Encéfalo/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Razão Sinal-Ruído
4.
Magn Reson Med ; 84(4): 2278-2289, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32385932

RESUMO

PURPOSE: The aim of this work was to provide parallel imaging capability for the human head in a gradient insert of 33-cm inner diameter within the related constraints of space, encoding ambiguity, and eddy current immunity. METHODS: Eddy current behavior of the 8-channel transmit-receive array coil was investigated via heating and field deviation measurements. RF performance was evaluated using S-parameters, noise statistics, B1 maps, and g-factor maps. In vivo images of a human head and knee were acquired with Cartesian readout and TE below 0.45 ms. RESULTS: Under intense gradient use, the shield was heated up to 55°C and other coil structures to 40°C. After standard preemphasis calibration, eddy current-related field distortions caused by the developed RF coil were smaller than for a commercial receive-only coil. In the ambiguous regions of the gradient, B1+ is 20 dB lower than in the center of the FOV. Coupling between elements is below -15 dB, and noise correlation is less than 0.31 when the coil is loaded with a head. Power efficiency was 0.52 ± 0.02 µT/√W, and the SD of the flip angle was below 10% in central slices of the brain. 2D, up to fourfold acceleration causes less than 30% noise amplification. The RF coil can be used during full gradient performance. CONCLUSION: Based on the described features, the presented coil enables parallel imaging in the high-performance gradient insert.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Temperatura Alta , Humanos , Neuroimagem , Imagens de Fantasmas
5.
Magn Reson Med ; 84(4): 1933-1946, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32176828

RESUMO

PURPOSE: To achieve high resolution in imaging of short-T2 materials and tissues by using a high-performance human-sized gradient insert with strength up to 200 mT/m and 100% duty cycle. METHODS: Dedicated short-T2 methodology and hardware are used, such as the pointwise encoding time reduction with radial acquisition (PETRA) technique with modulated excitation pulses, optimized radio-frequency hardware, and a high-performance gradient insert. A theoretical analysis of actual spatial resolution and SNR is provided to support the choice of scan parameters and interpretation of the results. Imaging is performed in resolution phantoms, animal specimen, and human volunteers at both conventional and maximum available gradient strengths and compared using image subtraction. RESULTS: Calculations suggest that increasing gradient strength beyond conventional values considerably improves both actual resolution and SNR efficiency in short-T2 imaging. Resolution improvements are confirmed in all investigated samples, in particular 2 mm slots were resolved in a hard-plastic plate with T2 ≈ 10 µs and in vivo musculoskeletal images were acquired at isotropic 200 µm resolution. Expected improvements in signal yield are realized in fine structures benefitting from high resolution but to less extent in regions of low contrast where decay-related blurring leads to signal overlap between neighboring locations. CONCLUSION: Strong gradients with high duty cycle enable short-T2 imaging at unprecedentedly high resolution, holding the potential for improving MRI of, eg, bone, tendon, lung, or teeth. Moreover, it allows direct access of tissues with T2 of tens of microseconds such as myelin or collagen.


Assuntos
Imageamento por Ressonância Magnética , Ondas de Rádio , Animais , Voluntários Saudáveis , Humanos , Bainha de Mielina , Imagens de Fantasmas
6.
IEEE Trans Med Imaging ; 39(4): 997-1007, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31484112

RESUMO

In magnetic resonance imaging, the use of array detection and the number of detector elements have seen a steady increase over the past two decades. As a result, per-channel analog connection via long coaxial cable, as commonly used, poses an increasing challenge in terms of handling, safety, and coupling among cables. This situation is exacerbated when complementary recording of radiofrequency transmission or NMR-based magnetic field sensing further add to channel counts. A generic way of addressing this trend is the transition to digital signal transmission, enabled by digitization and first-level digital processing close to detector coils and sensors in the magnet bore. The foremost challenge that comes with this approach is to achieve high dynamic range, linearity, and phase stability despite interference by strong static, audiofrequency, and radiofrequency fields. The present work reports implementation of a 16-channel in-bore receiver, performing signal digitization and processing with subsequent optical transmission over fiber. Along with descriptions of the system design and construction, performance evaluation is reported. The resulting device is fully MRI compatible providing practically equal performance and signal quality compared to state-of-the-art RF digitizers operating outside the magnet. Its use is demonstrated by examples of head imaging and magnetic field recording.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Processamento de Sinais Assistido por Computador/instrumentação , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Humanos , Campos Magnéticos , Imageamento por Ressonância Magnética/métodos , Imagens de Fantasmas
7.
IEEE Trans Med Imaging ; 39(4): 1138-1148, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31567076

RESUMO

Developments in magnetic resonance imaging (MRI) in the last decades show a trend towards a growing number of array coils and an increasing use of a wide variety of sensors. Associated cabling and safety issues have been addressed by moving data acquisition closer to the coil. However, with the increasing number of radio-frequency (RF) channels and trend towards higher acquisition duty-cycles, the data amount is growing, which poses challenges for throughput and data handling. As it is becoming a limitation, early compression and preprocessing is becoming ever more important. Additionally, sensors deliver diverse data, which require distinct and often low-latency processing for run-time updates of scanner operation. To address these challenges, we propose the transition to reconfigurable hardware with an application tailored assembly of interfaces and real-time processing resources. We present an integrated solution based on a system-on-chip (SoC), which offers sufficient throughput and hardware-based parallel processing power for very challenging applications. It is equipped with fiber-optical modules serving as versatile interfaces for modular systems with in-field operation. We demonstrate the utility of the platform on the example of concurrent imaging and field sensing with hardware-based coil compression and trajectory extraction. The preprocessed data are then used in expanded encoding model based image reconstruction of single-shot and segmented spirals as used in time-series and anatomical imaging respectively.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Encéfalo/diagnóstico por imagem , Desenho de Equipamento , Humanos , Razão Sinal-Ruído
8.
Magn Reson Med ; 79(4): 2036-2045, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28856717

RESUMO

PURPOSE: MRI of tissues with short coherence lifetimes T2 or T2* can be performed efficiently using zero echo time (ZTE) techniques such as algebraic ZTE, pointwise encoding time reduction with radial acquisition (PETRA), and water- and fat-suppressed proton projection MRI (WASPI). They share the principal challenge of recovering data in central k-space missed due to an initial radiofrequency dead time. The purpose of this study was to compare the three techniques directly, with a particular focus on their behavior in the presence of ultra-short-lived spins. METHODS: The most direct comparison was enabled by aligning acquisition and reconstruction strategies of the three techniques. Image quality and short- T2* performance were investigated using point spread functions, 3D simulations, and imaging of phantom and bone samples with short (<1 ms) and ultra-short (<100 µs) T2*. RESULTS: Algebraic ZTE offers favorable properties but is limited to k-space gaps up to approximately three Nyquist dwells. At larger gaps, PETRA enables robust imaging with little compromise in image quality, whereas WASPI may be prone to artifacts from ultra-short T2* species. CONCLUSION: For small k-space gaps (<4 dwells) and T2* much larger than the dead time, all techniques enable artifact-free short- T2* MRI. However, if these requirements are not fulfilled careful consideration is needed and PETRA will generally achieve better image quality. Magn Reson Med 79:2036-2045, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética , Algoritmos , Animais , Artefatos , Osso e Ossos/diagnóstico por imagem , Bovinos , Simulação por Computador , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Modelos Teóricos , Imagens de Fantasmas , Polimetil Metacrilato/química , Prótons , Ondas de Rádio , Tíbia/diagnóstico por imagem
9.
IEEE Trans Med Imaging ; 37(2): 408-416, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28910759

RESUMO

For magnetic resonance imaging of tissues with very short transverse relaxation times, radio-frequency excitation must be immediately followed by data acquisition with fast spatial encoding. In zero-echo-time (ZTE) imaging, excitation is performed while the readout gradient is already on, causing data loss due to an initial dead time. One major dead time contribution is the settling time of the filters involved in signal down-conversion. In this paper, a multi-rate acquisition scheme is proposed to minimize dead time due to filtering. Short filters and high output bandwidth are used initially to minimize settling time. With increasing time since the signal onset, longer filters with better frequency selectivity enable stronger signal decimation. In this way, significant dead time reduction is accomplished at only a slight increase in the overall amount of output data. Multi-rate acquisition was implemented with a two-stage filter cascade in a digital receiver based on a field-programmable gate array. In ZTE imaging in a phantom and in vivo, dead time reduction by multi-rate acquisition is shown to improve image quality and expand the feasible bandwidth while increasing the amount of data collected by only a few percent.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Humanos , Imagens de Fantasmas , Ondas de Rádio
10.
Magn Reson Med ; 79(4): 2046-2056, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-28840611

RESUMO

PURPOSE: To develop a method of tracking active NMR markers that requires no alterations of common imaging sequences and can be used for prospective motion correction (PMC) in brain MRI. METHODS: Localization of NMR markers is achieved by acquiring short signal snippets in rapid succession and evaluating them jointly. To spatially encode the markers, snippets are timed such that signal phase is accrued during sequence intervals with suitably diverse gradient actuation. For motion tracking and PMC in brain imaging, the markers are mounted on a lightweight headset. PMC is then demonstrated with high-resolution T2 *- and T1 -weighted imaging sequences in the presence of instructed as well as residual unintentional head motion. RESULTS: With both unaltered sequences, motion tracking was achieved with precisions on the order of 10 µm and 0.01° and temporal resolution of 48 and 39 ms, respectively. On this basis, PMC improved image quality significantly throughout. CONCLUSION: The proposed approach permits high-precision motion tracking and PMC with standard imaging sequences. It does so without altering sequence design and thus overcomes a key hindrance to routine motion tracking with NMR markers. Magn Reson Med 79:2046-2057, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Cabeça/diagnóstico por imagem , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética , Calibragem , Desenho de Equipamento , Voluntários Saudáveis , Humanos , Processamento de Imagem Assistida por Computador , Movimento (Física) , Imagens de Fantasmas , Processamento de Sinais Assistido por Computador , Razão Sinal-Ruído
11.
Neuroimage ; 168: 88-100, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-28774650

RESUMO

We report the deployment of spiral acquisition for high-resolution structural imaging at 7T. Long spiral readouts are rendered manageable by an expanded signal model including static off-resonance and B0 dynamics along with k-space trajectories and coil sensitivity maps. Image reconstruction is accomplished by inversion of the signal model using an extension of the iterative non-Cartesian SENSE algorithm. Spiral readouts up to 25 ms are shown to permit whole-brain 2D imaging at 0.5 mm in-plane resolution in less than a minute. A range of options is explored, including proton-density and T2* contrast, acceleration by parallel imaging, different readout orientations, and the extraction of phase images. Results are shown to exhibit competitive image quality along with high geometric consistency.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Encéfalo/anatomia & histologia , Feminino , Humanos , Masculino , Adulto Jovem
12.
Sci Adv ; 3(9): e1701879, 2017 09.
Artigo em Inglês | MEDLINE | ID: mdl-28929140

RESUMO

Granular dynamics govern earthquakes, avalanches, and landslides and are of fundamental importance in a variety of industries ranging from energy to pharmaceuticals to agriculture. Nonetheless, our understanding of the underlying physics is poor because we lack spatially and temporally resolved experimental measurements of internal grain motion. We introduce a magnetic resonance imaging methodology that provides internal granular velocity measurements that are four orders of magnitude faster compared to previous work. The technique is based on a concerted interplay of scan acceleration and materials engineering. Real-time probing of granular dynamics is explored in single- and two-phase systems, providing fresh insight into bubble dynamics and the propagation of shock waves upon impact of an intruder. We anticipate that the methodology outlined here will enable advances in understanding the propagation of seismic activity, the jamming transition, or the rheology and dynamics of dense suspensions.

14.
Magn Reson Med ; 78(1): 399-407, 2017 07.
Artigo em Inglês | MEDLINE | ID: mdl-27505183

RESUMO

PURPOSE: MRI of tissues with rapid transverse relaxation can be performed efficiently using the zero echo time (ZTE) technique. At high bandwidths leading to large relative initial radiofrequency (RF) dead times, the method becomes increasingly sensitive to artifacts related to signal stemming from outside the field of view, particularly from the RF coils. Therefore, in this work, a birdcage coil was designed that is virtually free of 1H signal. METHODS: A transmit-receive birdcage RF coil for MRI of joints at 7T was designed by rigorously avoiding materials containing 1H nuclei, by using purely mechanical connections without glue, and by spoiling of unwanted signal by application of ferromagnetic materials. The coil was tested for residual 1H signal using ZTE phantom and in vivo joint imaging. RESULTS: In standard ZTE imaging, no 1H signal was detected above noise level. Only at extreme averaging, residual signal was observed close to conductors associated with 1H-containing molecules at adjacent glass surfaces. Phantom images with dead times up to 3.8 Nyquist dwells were obtained with only negligible background artifacts. Furthermore, high-quality ZTE images of human joints were acquired. CONCLUSION: A virtually 1H-free birdcage coil is presented, thus enabling in vivo ZTE MRI practically free of background signal, even at high bandwidths. Magn Reson Med 78:399-407, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Aumento da Imagem/instrumentação , Articulações/anatomia & histologia , Articulações/diagnóstico por imagem , Imageamento por Ressonância Magnética/instrumentação , Transdutores , Artefatos , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Prótons , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
15.
IEEE Trans Biomed Circuits Syst ; 11(6): 1245-1255, 2017 12.
Artigo em Inglês | MEDLINE | ID: mdl-29293422

RESUMO

Magnetic resonance imaging (MRI) is among the most important medical imaging modalities. Coil arrays and receivers with high channel counts (16 and more) have to be deployed to obtain the image quality and acquisition speed required by modern clinical protocols. In this paper, we report the theoretical analysis, the system-level design, and the circuit implementation of the first receiver IC (RXIC) for clinical MRI fully integrated in a modern CMOS technology. The dual-channel RXIC sits directly on the sensor coil, thus eliminating any RF cable otherwise required to transport the information out of the magnetic field. The first stage LNA was implemented using a noise-canceling architecture providing a highly reflective input used to decouple the individual channels of the array. Digitization is performed directly on-chip at base-band by means of a delta-sigma modulator, allowing the subsequent optical transmission of data. The presented receiver, implemented in a CMOS technology, is compatible with MRI scanners up to . It reaches sub- noise figure for MRI units and features a dynamic range up to at a power consumption below per channel, with an area occupation of . Mounted on a small-sized printed circuit board (PCB), the receiver IC has been employed in a commercial MRI scanner to acquire in-vivo images matching the quality of traditional systems, demonstrating the first step toward multichannel wearable MRI array coils.


Assuntos
Imageamento por Ressonância Magnética/métodos , Desenho de Equipamento , Razão Sinal-Ruído
16.
Magn Reson Med ; 77(1): 83-91, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-27770473

RESUMO

PURPOSE: The purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. METHODS: Image formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B0 , and coil sensitivity encoding. The encoding model is determined by B0 mapping, sensitivity mapping, and concurrent field monitoring. Reconstruction is performed by iterative inversion of the expanded signal equations. Diffusion-tensor imaging with single-shot spiral readouts is performed in a phantom and in vivo, using a clinical 3T instrument. Image quality is assessed in terms of artefact levels, image congruence, and the influence of the different encoding factors. RESULTS: Using the full encoding model, diffusion-weighted single-shot spiral imaging of high quality is accomplished both in vitro and in vivo. Accounting for actual field dynamics, including higher orders, is found to be critical to suppress blurring, aliasing, and distortion. Enhanced image congruence permitted data fusion and diffusion tensor analysis without coregistration. CONCLUSION: Use of an expanded signal model largely overcomes the traditional vulnerability of spiral imaging with long readouts. It renders single-shot spirals competitive with echo-planar readouts and thus deploys shorter echo times and superior readout efficiency for diffusion imaging and further prospective applications. Magn Reson Med 77:83-91, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Imagem de Difusão por Ressonância Magnética/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Encéfalo/diagnóstico por imagem , Humanos , Masculino , Imagens de Fantasmas
17.
Nat Commun ; 7: 13702, 2016 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-27910860

RESUMO

High-field magnets of up to tens of teslas in strength advance applications in physics, chemistry and the life sciences. However, progress in generating such high fields has not been matched by corresponding advances in magnetic field measurement. Based mostly on nuclear magnetic resonance, dynamic high-field magnetometry is currently limited to resolutions in the nanotesla range. Here we report a concerted approach involving tailored materials, magnetostatics and detection electronics to enhance the resolution of nuclear magnetic resonance sensing by three orders of magnitude. The relative sensitivity thus achieved amounts to 1 part per trillion (10-12). To exemplify this capability we demonstrate the direct detection and relaxometry of nuclear polarization and real-time recording of dynamic susceptibility effects related to human heart function. Enhanced high-field magnetometry will generally permit a fresh look at magnetic phenomena that scale with field strength. It also promises to facilitate the development and operation of high-field magnets.

18.
Magn Reson Med ; 76(6): 1730-1740, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-26762657

RESUMO

PURPOSE: Noise-optimal reconstruction of array transmitter calibrations would ideally require knowledge of the receive array sensitivities which can often only be measured once the transmitter is calibrated to provide sufficient coverage. This poses often a problem in bootstrapping transmit-receive arrays particularly at ultrahigh fields. METHODS: Said problem is resolved by formulating the local transmit-receive efficiency of the array setup as a bilinear form and deriving therefrom a noise-optimal, joint reconstruction of the calibration data resulting in the relative sensitivities of the used transmitters and receivers. RESULTS: Retrieval and reconstruction of parallel transmission calibration data in phantoms and in vivo are presented using an eight-channel parallel transmit setup with up to 16 receivers using strip-line TR arrays and parallel transmission by traveling waves. CONCLUSION: Data sets from calibration scans are reconstructed robustly and with optimal signal-to-noise ratio. The found array signal gain is furthermore a direct performance measure for array transmitter and receiver combinations. The concomitantly obtained image was shown to have maximum coverage of the subject. Magn Reson Med 76:1730-1740, 2016. © 2016 International Society for Magnetic Resonance in Medicine.


Assuntos
Algoritmos , Aumento da Imagem/instrumentação , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Transdutores , Calibragem , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Razão Sinal-Ruído
19.
J Magn Reson ; 263: 147-155, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26796113

RESUMO

For direct NMR detection and imaging of compounds with very short coherence life times the dead time between radio-frequency (RF) pulse and reception of the free induction decay (FID) is a major limiting factor. It is typically dominated by the transient and recovery times of currently available transmit-receive (T/R) switches and amplification chains. A novel PIN diode-based T/R switch topology is introduced allowing for fast switching by high bias transient currents but nevertheless producing a very low video leakage signal and insertion loss (0.5dB). The low transient spike level in conjunction with the high isolation (75dB) prevent saturation of the preamplifier entirely which consequently does not require time for recovery. Switching between transmission and reception is demonstrated within less than 1µs in bench tests as well as in acquisitions of FIDs and zero echo time (ZTE) images with bandwidths up to 500kHz at 7T. Thereby the 2kW switch exhibited a rise-time of 350ns (10-99%) producing however a total video leakage of below 20mV peak-to-peak and less than -89dBm in-band. The achieved switching time renders the RF pulse itself the dominant contribution to the dead time in which a coherence cannot be observed, thus making pulsed NMR experiments almost time-optimal even for compounds with very short signal life times.

20.
IEEE Trans Med Imaging ; 35(6): 1452-62, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26742126

RESUMO

MRI relies on static and spatially varying dynamic magnetic fields of high accuracy. NMR field probes permit the direct observation of spatiotemporal field dynamics for diverse purposes such as data correction, field control, sequence validation, and hardware characterization. However, due to probe signal decay and dephasing existing field cameras are limited in terms of readout duration and the extent of k -space that can be covered. The present work aims to overcome these limitations by the transition to short-lived NMR probes and rapid re-excitation. The proposed approach uses probes with T 2 so short that thermal relaxation dominates signal decay even in the presence of strongest gradients. They are integrated with transmit, receive and sequencing electronics that permit high-rate re-excitation with optional probe alternation as well as complementary RF pulse recording. The system is demonstrated by monitoring of sample MRI sequences with long readouts and large gradient moments. It is compared with the conventional long-lived probe concept and characterized in terms of net sensitivity and sources of systematic error. Continuous k -space trajectory mapping is demonstrated and validated by trajectory-based image reconstruction.


Assuntos
Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Ondas de Rádio