Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.311
Filtrar
1.
Glob Chall ; 8(7): 2300408, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39006060

RESUMO

This review aims to provide an overview of sustainable approaches that can be incorporated into well-known procedures for the development of materials, pre- and post-treatments, modifications, and applications of 3D-printed objects, especially for fused filament fabrication (FFF). Different examples of conductive and non-conductive bespoke filaments using renewable biopolymers, bioplasticizers, and recycled materials are presented and discussed. The main final characteristics of the polymeric materials achieved according to the feedstock, preparation, extrusion, and treatments are also covered. In addition to recycling and remanufacturing, this review also explores other alternative approaches that can be adopted to enhance the sustainability of methods, aiming to produce efficient and environmentally friendly 3D printed products. Adjusting printing parameters and miniaturizing systems are also highlighted in this regard. All these recommended strategies are employed to minimize environmental damage, while also enabling the production of high-quality, economical materials and 3D printed systems. These efforts align with the principles of Green Chemistry, Sustainable Development Goals (SDGs), 3Rs (Reduce, Reuse, Recycle), and Circular Economy concepts.

2.
J Periodontol ; 2024 Jun 26.
Artigo em Inglês | MEDLINE | ID: mdl-38923568

RESUMO

BACKGROUND: The aim of this study was to evaluate the incidence of preloading crestal bone loss (PLCBL) and to identify the patient-related and implant-related factors associated with PLCBL. METHODS: This retrospective cohort examined the dental records of patients who received at least one dental implant. PLCBL was defined as a reduction ⩾0.5 mm and severe PLCBL (primary variable) as a reduction ⩾1.5 mm in mesial and/or distal bone level, measured from the day of implant placement to uncovering or abutment installation/crown delivery. The incidence of PLCBL and patient and implant variables were recorded. Bivariate analysis and binary logistic regression identified factors associated with PLCBL ⩾0.5 mm and ⩾1.5 mm. RESULTS: A total of 746 dental implants placed in 361 patients from January 2011 to July 2021 was included in the analyses. Of the implants assessed, 24.4% (n = 182) exhibited PLCBL ⩾ 0.5 mm and 10.5% (n = 78) presented severe PLCBL (i.e., ⩾1.5 mm). Males (odds ratio [OR] = 1.85, 95% confidence interval [CI] = 1.11-3.07), patients with diabetes (OR = 3.33, 95% CI = 1.73-6.42), and those allergic to penicillin (OR = 3.13, 95% CI = 1.57-6.22) were more likely to experience severe PLCBL (p < 0.05). Implants placed in the anterior area (OR = 2.08, 95% CI = 1.16-3.73), with bone-level platform-abutment connection (OR = 4.73, 95% CI = 1.94-11.49) and inserted supracrestally (OR = 3.77, 95% CI = 1.84-7.72), presented a greater risk of developing severe PLCBL (p < 0.05). Implants placed in a previously grafted area presented a lower likelihood of developing severe PLCBL (OR = 0.489, 95% CI = 0.28-0.84). CONCLUSION: The incidence of PLCBL ⩾ 0.5 mm and ⩾1.5 mm was 24.4% and 10.5%, respectively. Male sex, diabetes, allergy to penicillin, anterior location, bone-level platform-abutment connection, and supracrestal implant placement are potential risk factors for severe PLCBL. A previously grafted area is a potential protective factor.

3.
Proc Natl Acad Sci U S A ; 121(27): e2405963121, 2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38923988

RESUMO

Under nonequilibrium conditions, inorganic systems can produce a wealth of life-like shapes and patterns which, compared to well-formed crystalline materials, remain widely unexplored. A seemingly simple example is the formation of salt deposits during the evaporation of sessile droplets. These evaporites show great variations in their specific patterns including single rings, creep, small crystals, fractals, and featureless disks. We have explored the patterns of 42 different salts at otherwise constant conditions. Based on 7,500 images, we show that distinct pattern families can be identified and that some salts (e.g., Na2SO4 and NH4NO3) are bifurcated creating two distinct motifs. Family affiliations cannot be predicted a priori from composition alone but rather emerge from the complex interplay of evaporation, crystallization, thermodynamics, capillarity, and fluid flow. Nonetheless, chemical composition can be predicted from the deposit pattern with surprisingly high accuracy even if the set of reference images is small. These findings suggest possible applications including smartphone-based analyses and lightweight tools for space missions.

4.
Patient Prefer Adherence ; 18: 1281-1297, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38919378

RESUMO

Background: There is no consistent framework for patient-centric drug product design, despite the common understanding that drug product acceptability and preferences influence adherence and, therefore, drug product effectiveness. The aim of this review was to assess current understanding of patient acceptability and preferences for solid oral dosage form (SODF) drug product attributes, and the potential impact of these attributes on patient behaviors and outcomes. Patients and Methods: A scoping review was conducted. Embase, Ovid MEDLINE®, and PubMed® were searched for full-text articles published between January 2013 and May 2023. Following screening and assessment against predefined inclusion criteria, data were analyzed thematically. Results: Nineteen studies were included. Four overarching domains of drug product attributes were identified and summarized in a framework: appearance, swallowability, palatability, and handling. Each domain was informed by specific drug product attributes: texture, form, size, shape, color, marking, taste, mouthfeel, and smell. The most frequently studied domains were swallowability and appearance, while the most studied attributes were size, shape, and texture. Smell, marking, and mouthfeel were the least studied attributes. Texture intersected all domains, while form, shape, and size intersected appearance, swallowability, and handling. Swallowability and size appeared to be the key domain and attribute, respectively, to consider when designing drug products. Few studies explored the impact of drug product attributes on behaviors and outcomes. Conclusion: While existing studies of drug product attributes have focused on appearance and swallowability, this review highlighted the importance of two less well-understood domains-palatability and handling-in understanding patients' acceptability and preferences for SODF drug products. The framework provides a tool to facilitate patient-centric design of drug products, organizing and categorizing physical drug product attributes into four overarching domains (appearance, swallowability, palatability, and handling), encouraging researchers to comprehensively assess the impact of drug product attributes on patient acceptability, preferences, and outcomes.


Medicines come in a variety of types and forms. These include tablets and capsules. Factors, such as the size and shape of tablets, can affect how people take medicines. However, patients are rarely involved in designing the medicines that they take. In this study, researchers summarized 19 studies published between 2013 and 2023. They wanted to understand how different factors, like size and shape, affect patients' preferences, ability, and willingness to take medicines. Researchers focused on the "physical" aspects of medicines and found 4 common themes: 1) what they look like (appearance), 2) how easy they are to swallow (swallowability), 3) how they taste and feel in the mouth (palatability), and 4) how easy they are to handle (handling). Eight factors were also found: color, markings, shape, size, smell, taste, texture, and how a medicine feels in the mouth (mouthfeel). Most studies focused on what medicines look like and how easy they are to swallow. The factors that researchers mostly looked at were the size, shape, and texture of medicines. The design of medicines can impact patients of different ages, though there may be specific needs for certain groups of patients, including children, older adults, and people with certain diseases. Patient input should become a part of future medicines design to ensure their acceptability.

5.
Cancers (Basel) ; 16(11)2024 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-38893214

RESUMO

Microwave ablation (MWA) of liver tumors presents challenges like under- and over-ablation, potentially leading to inadequate tumor destruction and damage to healthy tissue. This study aims to develop personalized three-dimensional (3D) models to simulate MWA for liver tumors, incorporating patient-specific characteristics. The primary objective is to validate the predicted ablation zones compared to clinical outcomes, offering insights into MWA before therapy to facilitate accurate treatment planning. Contrast-enhanced CT images from three patients were used to create 3D models. The simulations used coupled electromagnetic wave propagation and bioheat transfer to estimate the temperature distribution, predicting tumor destruction and ablation margins. The findings indicate that prolonged ablation does not significantly improve tumor destruction once an adequate margin is achieved, although it increases tissue damage. There was a substantial overlap between the clinical ablation zones and the predicted ablation zones. For patient 1, the Dice score was 0.73, indicating high accuracy, with a sensitivity of 0.72 and a specificity of 0.76. For patient 2, the Dice score was 0.86, with a sensitivity of 0.79 and a specificity of 0.96. For patient 3, the Dice score was 0.8, with a sensitivity of 0.85 and a specificity of 0.74. Patient-specific 3D models demonstrate potential in accurately predicting ablation zones and optimizing MWA treatment strategies.

7.
Eur J Dent ; 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698613

RESUMO

OBJECTIVE: The aim of this study was to evaluate the accuracy of the Root ZX II (RZX), Raypex 6 (RAY), EPex Pro (EPEX), and CanalPro (CNP) electronic foramen locators (EFLs) in different foraminal morphologies (fully formed foramen, immature foramen with parallel walls, and immature foramen with divergent walls); this article also evaluated the influence of different penetration levels (0.0 mm and -1.0 mm). MATERIALS AND METHODS: Thirty single-rooted human premolars were accessed and had their cervical/middle thirds prepared with SX ProTaper files. The apical foramens (AF) were standardized to 250 µm and the initial root canal length (RCL1) was measured under 16x magnification with aid of a digital caliper. Using the alginate model, electronic measurements (EM) were taken 1.0 mm up to AF (EM1/-1) and at AF (EM1/0), always using adjusted hand K-files. The root apexes were then cross-sectioned 3.0 mm from the foramen; then, new RCL (RCL2) and electronic measurements were performed (EM2/-1 and EM2/0.0). Finally, retropreparations were performed with instruments SX ProTaper files introduced 4.0 mm in the apicocervical direction. Then new RCL (RCL3) and electronic measurements (EM3/-1 and EM3/0) were performed. STATISTICAL ANALYSIS: Values were tabulated and tested for normality using the Shapiro-Wilk test, which yielded nonparametric distributions of the data. Data were subjected to the Kruskal-Wallis and Dunn tests to estimate possible differences between devices as a function of foramen morphology and/or apical limit. The significance level was set at 5.0%. RESULTS: In general, the EFLs were accurate in determining the RCL. Statistically significant differences were observed between EPEX and RAY at 0.0, when measuring the divergent AF canals (p < 0.05). Regarding the different foramen morphologies in each EFL, RZX and EPEX showed no interference (p > 0.05), whereas RAY and CNP had lower accuracy levels at 0.0 with divergent AF (p < 0.05). CONCLUSION: The four devices evaluated are accurate to determine the RCL in the conditions tested. The apical limit of penetration did not have significant influence on their accuracy. Conversely, the presence of divergence in the AF walls negatively influenced de RAY and CNP precisions at the foraminal level.

8.
Front Toxicol ; 6: 1379272, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38711907

RESUMO

The evolving prevalence of anabolic androgenic steroids (AAS) abuse among nonathletes is alarming because of the known harm to an individual's health. Among the adverse effects of AAS abuse, male infertility and sexual dysfunction have been often reported in the literature, but little is known regarding its actual prevalence, possible underpinning mechanisms, and potential treatments either during or post-AAS usage. Thus, the current narrative review summarizes the state-of-art regarding the effects of AAS on male fertility and sexual function. Evidence was gathered from the latest reviews and recent original studies, specifically from prospective cohorts and clinical trials, ultimately resulting in five main topics of discussion. First, AAS usage is briefly characterized by its historical background, main physiological mechanisms, and the most frequently used AAS substances. Second, data on the prevalence of AAS-induced male infertility and sexual dysfunction are described. Third, some new insights on possible underpinning mechanisms of AAS-induced male infertility and sexual dysfunction are thoroughly discussed, with particular attention to histological data derived from animal models and the latest insights from prospective cohorts in humans. Fourth, the potential treatments during and after the AAS usage are presented, highlighting the odds of resolving male infertility and sexual dysfunction. Fifth, future directions on this topic are discussed, focusing on the methodological robustness of scientific studies.

9.
Cancers (Basel) ; 16(10)2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38791894

RESUMO

BACKGROUND: Our purpose is to evaluate the long-term oncologic efficacy and survival rates of MRI-guided cryoablation for patients with biopsy-proven cT1a renal cell carcinoma (RCC). MATERIALS AND METHODS: We retrospectively reviewed our renal ablation database between January 2007 and June 2021 and only included patients with solitary-biopsy-proven cT1a RCC (≤4 cm) who underwent MRI-guided cryoablation. We excluded patients with genetic syndromes, bilateral RCC, recurrent RCC or benign lesions, those without pathologically proven RCC lesions and patients who underwent radiofrequency ablation or CT-guided cryoablation. For each patient, we collected the following: age, sex, lesion size, right- or left-sided, pathology, ablation zone tumor recurrence, development of new tumor in the kidney other than ablation zone, development of metastatic disease, patient alive or not, date and cause of death. We used the Kaplan and Meier product limit estimator to estimate the survival outcomes. RESULTS: Twenty-nine patients (median age 70 years) met our inclusion criteria. Twenty-nine MRI-guided cryoablation procedures were performed for twenty-nine tumor lesions with a median size of 2.2 cm. A Clavien-Dindo grade III complication developed in one patient (3.4%). Clear cell RCC was the most reported histology (n = 19). The median follow up was 4.5 years. No tumor recurrence or metastatic disease developed in any of the patients. Two patients developed new renal lesions separate from the ablation zone. The 5- and 10-year OS were 72% and 55.6%, respectively. The 5- and 10-year DFS were 90.5% and the 5-year and 10-year LRFS, MFS and CSS were all 100%. CONCLUSIONS: MRI-guided cryoablation is a safe treatment with a low complication rate. Long-term follow-up data revealed long-standing oncologic control.

10.
Talanta ; 275: 126154, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38703477

RESUMO

Additive manufacturing is a technique that allows the construction of prototypes and has evolved a lot in the last 20 years, innovating industrial fabrication processes in several areas. In chemistry, additive manufacturing has been used in several functionalities, such as microfluidic analytical devices, energy storage devices, and electrochemical sensors. Theophylline and paracetamol are important pharmaceutical drugs where overdosing can cause adverse effects, such as tachycardia, seizures, and even renal failure. Therefore, this paper aims at the development of miniaturized electrochemical sensors using 3D printing and polylactic acid-based conductive carbon black commercial filament for theophylline and paracetamol detection. Electrochemical characterizations of the proposed sensor were performed to prove the functionality of the device. Morphological characterizations were carried out, in which chemical treatment could change the surface structure, causing the improvement of the analytical signal. Thus, the detection of theophylline at a linear range of 5.00-150 µmol L-1 with a limit of detection of 1.2 µmol L-1 was attained, and the detection of paracetamol at a linear range of 1.00-200 µmol L-1 with a limit of detection of 0.370 µmol L-1 was obtained, demonstrating the proposed sensor effectively detected pharmaceutical drugs.


Assuntos
Acetaminofen , Técnicas Eletroquímicas , Poliésteres , Fuligem , Teofilina , Acetaminofen/análise , Fuligem/química , Técnicas Eletroquímicas/métodos , Teofilina/análise , Poliésteres/química , Limite de Detecção , Impressão Tridimensional , Miniaturização
11.
Sci Total Environ ; 934: 172776, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-38697520

RESUMO

The expansion of the world's merchant fleet poses a great threat to the ocean's biodiversity. Collisions between ships and marine megafauna can have population-level consequences for vulnerable species. The Endangered whale shark (Rhincodon typus) shares a circumglobal distribution with this expanding fleet and tracking of movement pathways has shown that large vessel collisions pose a major threat to the species. However, it is not yet known whether they are also at risk within aggregation sites, where up to 400 individuals can gather to feed on seasonal bursts of planktonic productivity. These "constellation" sites are of significant ecological, socio-economic and cultural value. Here, through expert elicitation, we gathered information from most known constellation sites for this species across the world (>50 constellations and >13,000 individual whale sharks). We defined the spatial boundaries of these sites and their overlap with shipping traffic. Sites were then ranked based on relative levels of potential collision danger posed to whale sharks in the area. Our results showed that researchers and resource managers may underestimate the threat posed by large ship collisions due to a lack of direct evidence, such as injuries or witness accounts, which are available for other, sub-lethal threat categories. We found that constellations in the Arabian Sea and adjacent waters, the Gulf of Mexico, the Gulf of California, and Southeast and East Asia, had the greatest level of collision threat. We also identified 39 sites where peaks in shipping activity coincided with peak seasonal occurrences of whale sharks, sometimes across several months. Simulated collision mitigation options estimated potentially minimal impact to industry, as most whale shark core habitat areas were small. Given the threat posed by vessel collisions, a coordinated, multi-national approach to mitigation is needed within priority whale shark habitats to ensure collision protection for the species.


Assuntos
Conservação dos Recursos Naturais , Tubarões , Navios , Animais , Tubarões/fisiologia , Espécies em Perigo de Extinção , Monitoramento Ambiental
14.
J Vasc Interv Radiol ; 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38719091

RESUMO

The purpose of this study was to evaluate the technical success, effectiveness, and safety of transarterial embolization for acute bleeding management with a shear-thinning conformable embolic. This single-center retrospective study evaluated outcomes after embolization using Obsidio conformable embolic (OCE). Technical success was defined as performing transarterial embolization within the target vessel to complete stasis of antegrade flow. Treatment effectiveness was defined as cessation of bleeding for patients. Eleven patients underwent 11 embolization procedures. A total of 16 arteries were embolized. Indications for embolization were spontaneous tumor bleeding (6/11), hematuria (2/11), active duodenal bleeding (1/11), portal hypertensive bleeding (1/11), and rectus sheath hematoma (1/11). The technical success rate was 100%. The median vessel diameter was 2 mm (range, 1-3 mm). There were no adverse events or off-target embolization. OCE demonstrated technical success and treatment effectiveness with a short-term safety profile for transarterial embolization interventions.

15.
J Gastrointest Surg ; 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38754809

RESUMO

BACKGROUND: Liver-directed treatments - ablative therapy (AT), surgical resection (SR), liver transplantation (LT), and transarterial chemoembolization (TACE) - improve the overall survival of patients with early-stage hepatocellular carcinoma (HCC). Although racial and socioeconomic disparities affect access to liver-directed therapies, the temporal trends for the curative-intent treatment of HCC remain to be elucidated. METHODS: This study performed chi-square, logistic regression, and temporal trends analyses on data from the Nationwide Inpatient Sample from 2011 to 2019. The outcome of interest was the rate of AT, SR, LT (curative-intent treatments), and TACE utilization, and the primary predictors were racial/ethnic group and socioeconomic status (SES; insurance status). RESULTS: African American and Hispanic patients had lower odds of receiving AT (African American: odds ratio [OR], 0.78; P < .001; Hispanic: OR, 0.84; P = .005) and SR (African American: OR, 0.71; P < .001; Hispanics: OR, 0.64; P < .001) than White patients. Compared with White patients, the odds of LT was lower in African American patients (OR, 0.76; P < .001) but higher in Hispanic patients (OR, 1.25; P = .001). Low SES was associated with worse odds of AT (OR, 0.79; P = .001), SR (OR, 0.66; P < .001), and LT (OR, 0.84; P = .028) compared with high SES. Although curative-intent treatments showed significant upward temporal trends among White patients (10.6%-13.9%; P < .001) and Asian and Pacific Islander/other patients (14.4%-15.7%; P = .007), there were nonsignificant trends among African American patients (10.9%-10.1%; P = .825) or Hispanic patients (12.2%-13.7%; P = .056). CONCLUSION: Our study demonstrated concerning disparities in the utilization of curative-intent treatment for HCC based on race/ethnicity and SES. Moreover, racial/ethnic disparities have widened rather than improved over time.

16.
Cancer ; 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38642369

RESUMO

PURPOSE: To evaluate outcomes following percutaneous image-guided ablation of soft tissue sarcoma metastases to the liver. MATERIALS AND METHODS: A single-institution retrospective analysis of patients with a diagnosis of metastatic soft tissue sarcoma who underwent percutaneous image-guided ablation of hepatic metastases between January 2011 and December 2021 was performed. Patients with less than 60 days of follow-up after ablation were excluded. The primary outcome was local tumor progression-free survival (LPFS). Secondary outcomes included overall survival, liver-specific progression-free survival. and chemotherapy-free survival. RESULTS: Fifty-five patients who underwent percutaneous ablation for 84 metastatic liver lesions were included. The most common histopathological subtypes were leiomyosarcoma (23/55), followed by gastrointestinal stromal tumor (22/55). The median treated liver lesions was 2 (range, 1-8), whereas the median size of metastases were 1.8 cm (0.3-8.7 cm). Complete response at 2 months was achieved in 90.5% of the treated lesions. LPFS was 83% at 1 year and 80% at 2 years. Liver-specific progression-free survival was 66% at 1 year and 40% at 2 years. The overall survival at 1 and 2 years was 98% and 94%. The chemotherapy-free holiday from the start of ablation was 71.2% at 12 months. The complication rate was 3.6% (2/55); one of the complications was Common Terminology Criteria for Adverse Events grade 3 or higher. LPFS subgroup analysis for leiomyosarcoma versus gastrointestinal stromal tumor suggests histology-agnostic outcomes (2 years, 89% vs 82%, p = .35). CONCLUSION: Percutaneous image-guided liver ablation of soft tissue sarcoma metastases is safe and efficacious.

17.
J Am Coll Surg ; 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38661145

RESUMO

BACKGROUND: The direct association between procedure risk and outcomes in elderly emergency general surgery (EGS) patients has not been analyzed. Studies only highlight the importance of frailty. A comprehensive analysis of relevant risk factors and their association with outcomes in elderly EGS patients is lacking. We hypothesized that procedure risk has a stronger association with relevant outcomes in elderly EGS patients compared to frailty. STUDY DESIGN: Elderly patients (age > 65) undergoing emergency general surgery operative procedures were identified in the NSQIP) database (2018 to 2020) and stratified based on the presence of frailty calculated by the Modified 5 Item Frailty Index (mFI-5; mFI 0 Non-Frail, mFI 1-2 Frail, and mFI ≥3 Severely Frail) and based on procedure risk. Multivariable regression models and Receiving Operative Curve (ROC) analysis were used to determine risk factors associated with outcomes. RESULTS: A total of 59,633 elderly EGS patients were classified into non-frail (17,496; 29.3%), frail (39,588; 66.4%), and severely frail (2,549; 4.3%). There were 25,157 patients in the low-risk procedure group and 34,476 in the high-risk group.Frailty and procedure risk were associated with increased mortality, complications, failure to rescue, and readmissions. Differences in outcomes were greater when patients were stratified according to procedure risk compared to frailty stratification alone. Procedure risk had a stronger association with relevant outcomes in elderly EGS patients compared to frailty. CONCLUSIONS: Assessing frailty in the elderly EGS patient population without adjusting for the type of procedure or procedure risk ultimately presents an incomplete representation of how frailty impacts patient-related outcomes.

18.
Cancers (Basel) ; 16(6)2024 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-38539527

RESUMO

With the rapidly evolving field of image-guided tumor ablation, there is an increasing demand and need for tools to optimize treatment success. Known factors affecting the success of (non-)thermal liver ablation procedures are the ability to optimize tumor and surrounding critical structure visualization, ablation applicator targeting, and ablation zone confirmation. A recent study showed superior local tumor progression-free survival and local control outcomes when using transcatheter computed tomography hepatic angiography (CTHA) guidance in percutaneous liver ablation procedures. This pictorial review provides eight clinical cases from three institutions, MD Anderson (Houston, TX, USA), Gustave Roussy (Paris, France), and Amsterdam UMC (Amsterdam, The Netherlands), with the intent to demonstrate the added value of real-time CTHA guided tumor ablation for primary liver tumors and liver-only metastatic disease. The clinical illustrations highlight the ability to improve the detectability of the initial target liver tumor(s) and identify surrounding critical vascular structures, detect 'vanished' and/or additional tumors intraprocedurally, differentiate local tumor progression from non-enhancing scar tissue, and promptly detect and respond to iatrogenic hemorrhagic events. Although at the cost of adding a minor but safe intervention, CTHA-guided liver tumor ablation minimizes complications of the actual ablation procedure, reduces the number of repeat ablations, and improves the oncological outcome of patients with liver malignancies. Therefore, we recommend adopting CTHA as a potential quality-improving guiding method within the (inter)national standards of practice.

19.
J Gastrointest Surg ; 28(5): 766-775, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38519362

RESUMO

BACKGROUND: Postoperative hepatic insufficiency (PHI) is the most feared complication after hepatectomy. Volume of the future liver remnant (FLR) is one objectively measurable indicator to identify patients at risk of PHI. In this review, we summarized the development and rationale for the use of liver volumetry and liver-regenerative interventions and highlighted emerging tools that could yield new advancements in liver volumetry. METHODS: A review of MEDLINE/PubMed, Embase, and Cochrane Library databases was conducted to identify literature related to liver volumetry. The references of relevant articles were reviewed to identify additional publications. RESULTS: Liver volumetry based on radiologic imaging was developed in the 1980s to identify patients at risk of PHI and later used in the 1990s to evaluate grafts for living donor living transplantation. The field evolved in the 2000s by the introduction of standardized FLR based on the hepatic metabolic demands and in the 2010s by the introduction of the degree of hypertrophy and kinetic growth rate as measures of the FLR regenerative and functional capacity. Several liver-regenerative interventions, most notably portal vein embolization, are used to increase resectability and reduce the risk of PHI. In parallel with the increase in automation and machine assistance to physicians, many semi- and fully automated tools are being developed to facilitate liver volumetry. CONCLUSION: Liver volumetry is the most reliable tool to detect patients at risk of PHI. Advances in imaging analysis technologies, newly developed functional measures, and liver-regenerative interventions have been improving our ability to perform safe hepatectomy.


Assuntos
Hepatectomia , Regeneração Hepática , Fígado , Humanos , Hepatectomia/métodos , Tamanho do Órgão , Fígado/diagnóstico por imagem , Fígado/cirurgia , Insuficiência Hepática/etiologia , Embolização Terapêutica/métodos , Complicações Pós-Operatórias/etiologia , Transplante de Fígado/métodos , Veia Porta/diagnóstico por imagem , Veia Porta/cirurgia
20.
Eur Radiol ; 2024 Feb 09.
Artigo em Inglês | MEDLINE | ID: mdl-38334762

RESUMO

PURPOSE: To investigate the correlation of minimal ablative margin (MAM) quantification using biomechanical deformable (DIR) versus intensity-based rigid image registration (RIR) with local outcomes following colorectal liver metastasis (CLM) thermal ablation. METHODS: This retrospective single-institution study included consecutive patients undergoing thermal ablation between May 2016 and October 2021. Patients who did not have intraprocedural pre- and post-ablation contrast-enhanced CT images for MAM quantification or follow-up period less than 1 year without residual tumor or local tumor progression (LTP) were excluded. DIR and RIR methods were used to quantify the MAM. The registration accuracy was compared using Dice similarity coefficient (DSC). Area under the receiver operating characteristic curve (AUC) was used to test MAM in predicting local tumor outcomes. RESULTS: A total of 72 patients (mean age 57; 44 men) with 139 tumors (mean diameter 1.5 cm ± 0.8 (SD)) were included. During a median follow-up of 29.4 months, there was one residual unablated tumor and the LTP rate was 17% (24/138). The ranges of DSC were 0.96-0.98 and 0.67-0.98 for DIR and RIR, respectively (p < 0.001). When using DIR, 27 (19%) tumors were partially or totally registered outside the liver, compared to 46 (33%) with RIR. Using DIR versus RIR, the corresponding median MAM was 4.7 mm versus 4.0 mm, respectively (p = 0.5). The AUC in predicting residual tumor and 1-year LTP for DIR versus RIR was 0.89 versus 0.72, respectively (p < 0.001). CONCLUSION: Ablative margin quantified on intra-procedural CT imaging using DIR method outperformed RIR for predicting local outcomes of CLM thermal ablation. CLINICAL RELEVANCE STATEMENT: The study supports the role of biomechanical deformable image registration as the preferred image registration method over rigid image registration for quantifying minimal ablative margins using intraprocedural contrast-enhanced CT images. KEY POINTS: • Accurate and reproducible image registration is a prerequisite for clinical application of image-based ablation confirmation methods. • When compared to intensity-based rigid image registration, biomechanical deformable image registration for minimal ablative margin quantification was more accurate for liver registration using intraprocedural contrast-enhanced CT images. • Biomechanical deformable image registration outperformed intensity-based rigid image registration for predicting local tumor outcomes following colorectal liver metastasis thermal ablation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA