Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Mil Med ; 189(Supplement_3): 254-261, 2024 Aug 19.
Artigo em Inglês | MEDLINE | ID: mdl-39160838

RESUMO

INTRODUCTION: The initial management of penetrating ocular injuries is a major sight-threatening problem for both civilian and military medicine. A novel device (Eye-Aid) temporarily tamponades leakage from such injuries while being easy to remove upon arrival to specialized ophthalmologic care. Eye-Aid consists of a protective eye shield with an adhesive backing that connects to a portable canister containing rapidly deployable thermoresponsive foam. The aim of this study was to compare the use of the novel Eye-Aid device to control in a new live swine ocular injury model. MATERIALS AND METHODS: Bilateral penetrating ocular injuries were created on 14 male Yorkshire swine in a standardized manner using a 16-gauge needle device to puncture the central cornea and cause a full-thickness wound. Researchers randomized eye intervention side, with the contralateral eye used as paired control. Two minutes after the injury, the eye shield components of the Eye-Aid system, which has a sticky pad for attachment to the skin and a luer-lock for foam deployment, were placed bilaterally. Eight minutes after the injury, foam was deployed for the intervention eye according to the device instructions for use. For the control eye, no additional procedures were performed. Six hours post-injury, end A-scan and intraocular pressure (IOP) were measured. Primary study outcome was change in axial length of the globe. Secondary outcomes were as follows: (1) Presence of full anterior chamber collapse, defined as a lack of measurable anterior lens capsule-reflex (ALC-reflex) on A-scan and (2) change in IOP. Outcomes were analyzed as paired intra-animal data, with intervention and control data for each animal. A paired t-test was used to analyze the difference in axial length change and IOP change between treatment groups, whereas a conditional logistic regression was used to analyze dichotomous ALC-reflex outcome and estimate the odds ratio associated with the Eye-Aid device. RESULTS: A significant difference (P < .0001) in mean change in axial length between intervention (-210 µm) and control (-1,202 µm) groups was found. There was a significant difference in ALC-reflex presence, with 79% of eyes having an ALC-reflex in the intervention group, compared to 14% in the control (P = .008). IOP remained higher in the intervention group, with a mean change of -1.5 mmHg for the intervention group compared to -4.0 mmHg in the control (P = .0001). CONCLUSIONS: This study describes the first development of an in vivo large animal ocular injury model that realistically approximates the emergent time course and pathophysiology of patients with full-thickness corneal open globe injuries. It also gives the first description of using thermoreversible hydrogel foam for such injuries. Eye-Aid was found to be significantly better than control for treatment of such injuries, based on measurements of both structure and pressure. Assuming that the absence of an ALC-reflex demonstrates complete anterior chamber collapse, the Eye-Aid group demonstrated a 79% eye "save" rate compared to only 14% in the control group, as described earlier. This results in a Number Needed to Treat of 3 for this finding. Eye-Aid additionally demonstrated several characteristics that would be beneficial in a device targeted for emergent deployment by non-ophthalmologists.


Assuntos
Modelos Animais de Doenças , Ferimentos Oculares Penetrantes , Animais , Suínos , Ferimentos Oculares Penetrantes/terapia , Masculino , Pressão Intraocular/fisiologia
2.
Burns ; 50(6): 1578-1585, 2024 08.
Artigo em Inglês | MEDLINE | ID: mdl-38582695

RESUMO

BACKGROUND: This study compared a novel topical hydrogel burn dressing (CI-PRJ012) to standard of care (silver sulfadiazine) and to untreated control in a swine thermal burn model, to assess for wound healing properties both in the presence and absence of concomitant bacterial inoculation. METHODS: Eight equal burn wounds were created on six Yorkshire swine. Half the wounds were randomized to post-burn bacterial inoculation. Wounds were subsequently randomized to three treatments groups: no intervention, CI-PRJ012, or silver sulfadiazine cream. At study end, a blinded pathologist evaluated wounds for necrosis and bacterial colonization. RESULTS: When comparing CI-PRJ012 and silver sulfadiazine cream to no treatment, both agents significantly reduced the amount of necrosis and bacteria at 7 days after wound creation (p < 0.01, independently for both). Further, CI-PRJ012 was found to be significantly better than silver sulfadiazine (p < 0.02) in reducing bacterial colonization. For wound necrosis, no significant difference was found between silver sulfadiazine cream and CI-PRJ012 (p = 0.33). CONCLUSIONS: CI-PRJ012 decreases necrosis and bacterial colonization compared to no treatment in a swine model. CI-PRJ012 appeared to perform comparably to silver sulfadiazine. CI-PRJ012, which is easily removed with the application of room-temperature water, may provide clinical advantages over silver sulfadiazine.


Assuntos
Antibacterianos , Queimaduras , Modelos Animais de Doenças , Necrose , Sulfadiazina de Prata , Cicatrização , Animais , Queimaduras/tratamento farmacológico , Queimaduras/microbiologia , Queimaduras/patologia , Sulfadiazina de Prata/uso terapêutico , Projetos Piloto , Suínos , Cicatrização/efeitos dos fármacos , Antibacterianos/uso terapêutico , Anti-Infecciosos Locais/uso terapêutico , Hidrogéis/uso terapêutico , Bandagens , Infecção dos Ferimentos/tratamento farmacológico , Infecção dos Ferimentos/prevenção & controle , Distribuição Aleatória
3.
Mil Med ; 188(11-12): 3330-3335, 2023 11 03.
Artigo em Inglês | MEDLINE | ID: mdl-35820028

RESUMO

INTRODUCTION: Noncompressible torso hemorrhage is the leading cause of exsanguination on the battlefield. A self-expanding, intraperitoneal deployed, thermoreversible foam has been developed that can be easily administered by a medic in austere settings to temporarily tamponade noncompressible torso hemorrhage. The purpose of this study was to assess the long-term safety and physical characteristics of using Fast Onset Abdominal Management (FOAM; Critical Innovations LLC) in swine. MATERIALS AND METHODS: Yorkshire swine (40-60 kg) were sedated, intubated, and placed on ventilatory support. An external jugular catheter was placed for sampling of blood. Continuous heart rate, temperature, saturation of peripheral oxygen, end-tidal carbon dioxide, and peak airway pressures were monitored for a 4-hour period after intervention (i.e., FOAM agent injection or a sham introducer without agent delivery). The FOAM agent was injected to obtain an intra-abdominal pressure of 60 mmHg for at least 10 minutes. After 4 hours, the animals were removed from ventilatory support and returned to their housing for a period of 7-14 days. Group size analysis was not performed, as this was a descriptive safety study. Blood samples were obtained at baseline and at 1-hour post-intervention and then on days 1, 3, 7, and 14. Euthanasia, necropsy, and harvesting of samples for histologic analysis (from kidneys, terminal ilium, liver, pancreas, stomach, spleen, and lungs) were performed upon expiration. Histologic scoring for evidence of ischemia, necrosis, and abdominal compartment sequela was blinded and reported by semi-quantitative scale (range 0-4; 0 = no change, 1 = minimal, 2 = mild, 3 = moderate, and 4 = marked). Oregon Health & Science University's Institutional Animal Care and Use Committee, as well as the U.S. Army Animal Care and Use Review Office, approved this protocol before the initiation of experiments (respectively, protocol numbers IP00003591 and MT180006.e002). RESULTS: Five animals met a priori inclusion criteria, and all of these survived to their scheduled endpoints. Two animals received sham injections of the FOAM agent (one euthanized on day 7 and one on day 14), and three animals received FOAM agent injections (one euthanized on day 7 and two on day 14). A transitory increase in creatinine and lactate was detected during the first day in the FOAM injected swine but resolved by day 3. No FOAM agent was observed in the peritoneal cavity upon necropsy at day 7 or 14. Histologic data revealed no clinically relevant differences in any organ system between intervention and control animals upon sacrifice at day 7 or 14. CONCLUSIONS: This study describes the characteristics, survival, and histological analysis of using FOAM in a porcine model. In our study, FOAM reached the desired intra-abdominal pressure endpoint while not significantly altering basic hematologic parameters, except for transient elevations of creatinine and lactate on day 1. Furthermore, there was no clinical or histological relevant evidence of ischemia, necrosis, or intra-abdominal compartment syndrome. These results provide strong support for the safety of the FOAM device and will support the design of further regulatory studies in swine and humans.


Assuntos
Traumatismos Abdominais , Humanos , Suínos , Animais , Creatinina , Hemorragia/terapia , Tronco , Necrose , Lactatos , Isquemia
4.
Mil Med ; 188(1-2): 20-26, 2023 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34676417

RESUMO

INTRODUCTION: Traumatic brain injury is a major public health concern. Among patients with severe traumatic brain injury, epidural hemorrhage is known to swiftly lead to brain herniation and death unless there is emergent neurosurgical intervention. However, immediate neurosurgeon availability is frequently a problem outside of level I trauma centers. In this context, the authors desired to test a novel device for the emergent management of life-threatening epidural hemorrhage. A review of existing animal models determined that all were inadequate for this purpose, as they were found to be either inappropriate or obsolete. Here, we describe the development of a new epidural hemorrhage model in swine (Sus scrofa, 18-26 kg) ideal for translational device testing. MATERIALS AND METHODS: Vascular access was achieved using an ultrasound-guided percutaneous Seldinger catheter-over-wire technique with 5 Fr catheters placed in the bilateral carotid arteries, for continuous blood pressure and to allow for withdrawal of blood for creation of epidural hemorrhage. To simulate an actively bleeding and life-threatening epidural hemorrhage, unadulterated autologous blood was infused from the vascular access point into the epidural space. To be useful for this application and clinical scenario, brain death needed to occur after the planned intervention time but before the end of the protocol period (if no intervention took place). An iterative approach to model development determined that this could be achieved with an initial infusion rate of 1.0 mL/min, slowed to 0.5 mL/min after the first 10 minutes, paired with an intervention time at 15 minutes. All experiments were performed at Oregon Health & Science University, an Association for Assessment and Accreditation of Laboratory Animal Care accredited facility. Oregon Health & Science University's Institutional Animal Care and Use Committee, as well as the United States Army Animal Care and Use Review Office, reviewed and approved this protocol before the initiation of experiments (respectively, protocol numbers IP00002901 and 18116010.e001). RESULTS: The final developed model allows for the infusion of a known volume of autologous, unadulterated blood directly into the epidural space, without the use of a balloon or other restricting membranes, and is rapidly fatal in the absence of intervention. CONCLUSIONS: This animal model is the first to mirror the expected clinical course of epidural hemorrhage in a physiologically relevant manner, while allowing translational testing of emergency devices. This model successfully allowed the initial testing of a novel interventional device for the emergent management of epidural hemorrhage that was designed for use in the absence of traditional neurosurgical capabilities.


Assuntos
Lesões Encefálicas Traumáticas , Hemorragia , Animais , Suínos , Cateterismo , Catéteres , Procedimentos Neurocirúrgicos/métodos
5.
J Trauma Acute Care Surg ; 91(2S Suppl 2): S99-S106, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-34324472

RESUMO

BACKGROUND: Noncompressible hemorrhage is a leading cause of potentially survivable combat death, with the vast majority of such deaths occurring in the out-of-hospital environment. While large animal models of this process are important for device and therapeutic development, clinical practice has changed over time and past models must follow suit. Developed in conjunction with regulatory feedback, this study presents a modernized, out-of-hospital, noncompressible hemorrhage model, in conjunction with a randomized study of past, present, and future fluid options following a hypotensive resuscitation protocol consistent with current clinical practice. METHODS: We performed a randomized controlled experiment comparing three fluid resuscitation options in Yorkshire swine. Baseline data from animals of same size from previous experiments were analyzed (n = 70), and mean systolic blood pressure was determined, with a permissive hypotension resuscitation target defined as a 25% decrease from normal (67 mm Hg). After animal preparation, a grade IV to V liver laceration was induced. Animals bled freely for a 10-minute "time-to-responder" period, after which resuscitation occurred with randomized fluid in boluses to the goal target: 6% hetastarch in lactated electrolyte injection (HEX), normal saline (NS), or fresh whole blood (FWB). Animals were monitored for a total simulated "delay to definitive care" period of 2 hours postinjury. RESULTS: At the end of the 2-hour study period, 8.3% (1 of 12 swine) of the HEX group, 50% (6 of 12 swine) of the NS group, and 75% (9 of 12 swine) of the FWB had survived (p = 0.006), with Holm-Sidak pairwise comparisons showing a significant difference between HEX and FWB and (p = 0.005). Fresh whole blood had significantly higher systemic vascular resistance and hemoglobin levels compared with other groups (p = 0.003 and p = 0.001, respectively). CONCLUSION: Survival data support the movement away from HEX toward NS and, preferably, FWB in clinical practice and translational animal modeling. The presented model allows for future research including basic science, as well as translational studies of novel diagnostics, therapeutics, and devices.


Assuntos
Traumatismos Abdominais , Hidratação , Hemoperitônio , Ressuscitação , Choque Hemorrágico , Animais , Masculino , Traumatismos Abdominais/mortalidade , Traumatismos Abdominais/fisiopatologia , Traumatismos Abdominais/terapia , Modelos Animais de Doenças , Hidratação/métodos , Hidratação/mortalidade , Hemoperitônio/mortalidade , Hemoperitônio/fisiopatologia , Hemoperitônio/terapia , Fígado/lesões , Ressuscitação/métodos , Ressuscitação/mortalidade , Choque Hemorrágico/mortalidade , Choque Hemorrágico/fisiopatologia , Choque Hemorrágico/terapia , Suínos
6.
J Thorac Dis ; 13(1): 213-219, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-33569201

RESUMO

BACKGROUND: Tube thoracostomy is the definitive treatment for most significant chest trauma, including injuries resulting in pneumothorax, hemothorax, and hemopneumothorax. However, traditional chest tubes fail to sufficiently remove blood up to 20% of the time (i.e., retained hemothorax), which can lead to empyema and fibrothorax, as well as significant morbidity and mortality. Here we describe the use of a novel chest tube system in a swine model of hemothorax. METHODS: This was an intra-animal-paired, randomized-controlled study of hemothorax evacuation using the PleuraPath™ Thoracostomy System (PPTS) compared to a traditional chest tube in large Yorkshire-Landrace swine (75-85 kg). One liter of autologous whole blood was infused into each pleural cavity simultaneously with subsequent drainage from each device individually monitored for a total of 120 minutes, before the end of the experiment and necroscopy. RESULTS: Six animals completed the full protocol. On average, the PPTS removed 17% more blood (P=0.049) and left 19.1% less residual hemothorax (P=0.023) as compared to the standard of care during the first two hours of use. No complications or iatrogenic injury were identified in any animal for either device. CONCLUSIONS: The novel PPTS device was superior to the traditional chest tube drainage system in this acute, large-animal model of retained hemothorax. While this study supports clinical translation, further research will be required to assess efficacy and optimize device use in humans.

7.
J Surg Res ; 259: 175-181, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33290892

RESUMO

BACKGROUND: Noncompressible torso hemorrhage (NCTH) is a leading cause of traumatic exsanguination, requiring emergent damage control surgery performed by a highly trained surgeon in a sterile operating environment. A self-expanding, intraabdominally deployed, thermoreversible foam is one proposed method to potentially task shift temporizing hemostasis to earlier providers and additional settings. The purpose of this study was to assess the feasibility of using Fast Onset Abdominal Management (FOAM) in a lethal swine model of NCTH. METHODS: This was a proof-of-concept study comparing FOAM intervention in large Yorkshire swine to historical control animals in the established Ross-Burns model of NCTH. After animal preparation, a Grade IV liver laceration was surgically induced, followed by a free bleed period of 10 min. FOAM was then deployed to a goal intraabdominal pressure of 60 mm Hg for 5 min, followed by a total 60-min observation period following injury. RESULTS: At the end of the experiment, the FOAM agent was found to be distributed throughout the peritoneal cavity in all animals, without signs of iatrogenic injury. The FOAM group demonstrated a significantly higher mean arterial pressure compared with historical controls and a trend toward improved survival: 82% (9/11) compared with 50% for controls (7/14; P = 0.082). CONCLUSIONS: This is the first study to describe the use of a thermoresponsive foam to manage NCTH and successfully demonstrated proof-of-concept feasibility of FOAM deployment. These results provide strong support for future, higher-powered studies to confirm improved survival with this novel intervention.


Assuntos
Traumatismos Abdominais/terapia , Exsanguinação/terapia , Hemorragia/terapia , Traumatismos Abdominais/mortalidade , Animais , Modelos Animais de Doenças , Exsanguinação/mortalidade , Estudos de Viabilidade , Hemorragia/mortalidade , Poloxâmero , Suínos , Tronco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA