Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Am Soc Echocardiogr ; 10(6): 632-43, 1997.
Artigo em Inglês | MEDLINE | ID: mdl-9282353

RESUMO

Doppler echocardiographic characteristics of normally functioning Sorin Bicarbon prostheses were prospectively assessed in 226 consecutive patients (135 male and 91 female patients, mean age 61 +/- 10 years) with 233 valves in the mitral (n = 67) and aortic (n = 166) positions whose function was considered normal by clinical and echocardiographic evaluation. Patterns of "normal" transprosthetic leakage were assessed with transthoracic echocardiography in all valves and with transesophageal echocardiography in six selected mitral valve prostheses. For the mitral valve prostheses, we found that peak and mean gradient, as well as pressure half-time, were not significantly different in either the 25 or the 31 mm valves (median values from 15 to 10 mm Hg, from 4 to 4 mm Hg, and from 70 to 83 ms; p = Not significant for all). On transthoracic study, 12 patients (17%) with a Sorin Bicarbon valve in the mitral position showed minimal transprosthetic leakage. On transesophageal study, all patients showed a transprosthetic leakage whose spatial distribution had a complex pattern: in planes orthogonal to the leaflet axis, two to four jets arising from the hinge points and converging toward the center of the valve plane could be visualized; in planes parallel to the leaflet axis, there were three jets, the two lateral ones diverging and the central one perpendicular to the valve plane. For the aortic valve prostheses, there was a significant decrease in transprosthetic gradients and an increase in effective orifice areas as prosthesis size increased. Peak and mean gradients decreased from a median value of 25 and 13 mm Hg in the 19 mm valves to 9 and 5 mm Hg in the 29 mm valves, respectively. Effective prosthetic valve area calculated with the continuity equation increased from a median value of 0.97 cm2 for the 19 mm size valves to 3.45 cm2 for the 29 mm size. With analysis of variance, effective prosthetic aortic valve area differentiated various valve sizes (F = 40.9, p < 0.0001) better than peak (F = 10.3, p < 0.0001) or mean (F = 8.04, p < 0.0001) gradients alone did. Furthermore, effective prosthetic aortic valve area correlated better than peak and mean gradients with prosthetic size (r = 0.76, r = -0.45, and r = -0.39, respectively). On transthoracic study, 109 patients (66%) showed minimal transprosthetic leakage. These normal values, obtained in a large number of patients with normofunctioning mitral and aortic Sorin Bicarbon valves, may help to identify Sorin Bicarbon prosthesis dysfunction.


Assuntos
Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Próteses Valvulares Cardíacas , Valva Mitral/diagnóstico por imagem , Ecocardiografia Doppler , Feminino , Próteses Valvulares Cardíacas/instrumentação , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Desenho de Prótese , Valores de Referência
2.
G Ital Cardiol ; 21(2): 175-88, 1991 Feb.
Artigo em Italiano | MEDLINE | ID: mdl-1651265

RESUMO

Patients who have undergone surgical repair of congenital heart diseases are usually not allowed to participate in competitive sports. In the present study we report our long-term experience with 9 male athletes aged 17 to 23 years who participate in competitive sports after undergoing surgical repair of ostium secundum atrial septal defect at a median age of 9 years; six of them play football and three of them volleyball. Competitive sport activities began 1 to 5 years after surgical repair. The mean duration of follow-up is 88 +/- 26 months. Sport fitness was granted on the basis of the following criteria: 1) a normal physical examination; 2) a normal working capacity on exercise test; 3) no arrhythmias on exercise test and Holter monitoring, recorded also during sport activities; 4) a normal M-mode and two-dimensional echocardiography, including the normalization of right ventricular size; the persistence of an abnormal ventricular septal motion did not exclude sport fitness. Recently we also performed Doppler and color Doppler echocardiography and gated equilibrium radionuclide angiography at rest and during exercise. We studied left ventricular diastolic filling through the pulsed wave Doppler evaluation of transmitral flow and measured cardiac output by continuous wave Doppler echocardiography during exercise test in the supine position. We also performed exercise test and M-mode, two-dimensional, Doppler and color Doppler echocardiography in a control group made up of 15 athletes (10 football players and 5 volleyball players). The exercise duration at graded treadmill exercise test (according to the Carù protocol), the maximal heart rate and the maximal systolic blood pressure were, respectively, 12.9 +/- 0.8 min, 192 +/- 10 beats/min and 198 +/- 12 mmHg. Left ventricular end-diastolic dimension, mass and ejection fraction (single-plane area-length method) were 50.3 +/- 2.8 mm, 210 +/- 38 g and 65 +/- 6%. M-mode right ventricular diastolic dimension was 23.4 +/- 1.6 mm; the right ventricular maximal diastolic diameter and area obtained on two-dimensional echocardiography from the apical four chamber view were 44.1 +/- 3.6 mm and 25 +/- 3.8 cm2 respectively. The evaluation of transmitral flow showed the following data: E velocity 77 +/- 12 cm/sec, A velocity 45 +/- 6 cm/sec, E/A ratio 1.7 +/- 0.3, the isovolumic-relaxation period 72 +/- 8 m/sec and the deceleration half-time of the early rapid filling 71 +/- 10 m/sec. A trivial tricuspid regurgitation was detected in 6 subjects; the peak velocity of the regurgitant jet was less than 2.1 m/sec.(ABSTRACT TRUNCATED AT 400 WORDS)


Assuntos
Comunicação Interatrial/fisiopatologia , Esportes , Pirofosfato de Tecnécio Tc 99m , Adolescente , Adulto , Ecocardiografia , Ecocardiografia Doppler , Eletrocardiografia , Eletrocardiografia Ambulatorial , Teste de Esforço , Seguimentos , Coração/diagnóstico por imagem , Comunicação Interatrial/diagnóstico , Comunicação Interatrial/cirurgia , Humanos , Masculino , Período Pós-Operatório , Cintilografia , Pertecnetato Tc 99m de Sódio , Tecnécio , Polifosfatos de Estanho
3.
Minerva Cardioangiol ; 38(10): 447-9, 1990 Oct.
Artigo em Italiano | MEDLINE | ID: mdl-2074936

RESUMO

Echocardiography (M-mode and 2-dimensional) has identified unusual cardiac anomalies which, not related with cardiac murmurs or clicks or other clinical marks, had not been elsewhere discovered. Among them there is the atrial septal aneurysm, which often occurs with other cardiac malformations (congenital or acquired), but sometimes occurs as an isolated abnormality. The Authors report a case of isolated atrial septal aneurysm, detected in a 6 year-old boy.


Assuntos
Aneurisma Cardíaco , Átrios do Coração , Cardiomiopatias/diagnóstico por imagem , Criança , Ecocardiografia Doppler , Eletrocardiografia , Aneurisma Cardíaco/diagnóstico por imagem , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA