1.
Am Heart J ; 268: 104-113, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38042459

RESUMO

BACKGROUND: The high-sensitivity cardiac troponin (hs-cTn) I point-of-care (POC) hs-cTnI-PATHFAST assay has recently become clinically available. METHODS: We aimed to externally validate the hs-cTnI-PATHFAST 0/1h-algorithm recently developed for the early diagnosis of non-ST-segment-elevation myocardial infarction (NSTEMI) and derive and validate a 0/2-algorithm in patients presenting to the emergency department with acute chest discomfort included in a multicenter diagnostic study. Two independent cardiologists centrally adjudicated the final diagnoses using all the clinical and study-specific information available including serial measurements of hs-cTnI-Architect. RESULTS: Among 1,532 patients (median age 60 years, 33% [n = 501] women), NSTEMI was the final diagnosis in 13%. External validation of the hs-cTnI-PATHFAST 0/1h-algorithm showed very high negative predictive value (NPV; 100% [95%CI, 99.5%-100%]) and sensitivity 100% (95%CI, 98.2%-100%) for rule-out of NSTEMI. Positive predictive value (PPV) and specificity for rule-in of NSTEMI were high (74.9% [95%CI, 68.3%-80.5%] and 96.4% [95%CI, 95.2%-97.3%], respectively). Among 1,207 patients (median age 61 years, 32% [n = 391] women) available for the derivation (n = 848) and validation (n = 359) of the hs-cTnI-PATHFAST 0/2h-algorithm, a 0h-concentration <3 ng/L or a 0h-concentration <4 ng/L with a 2h-delta <4ng/L ruled-out NSTEMI in 52% of patients with a NPV of 100% (95%CI, 98-100) and sensitivity of 100% (95%CI, 92.9%-100%) in the validation cohort. A 0h-concentration ≥90ng/L or a 2h-delta ≥ 55ng/L ruled-in 38 patients (11%): PPV 81.6% (95%CI, 66.6-90.8), specificity 97.7% (95%CI, 95.4-98.9%). CONCLUSIONS: The POC hs-cTnI-PATHFAST assay allows rapid and effective rule-out and rule-in of NSTEMI using both a 0/1h- and a 0/2h-algorithm with high NPV/sensitivity for rule-out and high PPV/specificity for rule-in. CLINICAL TRIAL REGISTRATION: NCT00470587.


Assuntos
Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Infarto do Miocárdio com Supradesnível do Segmento ST , Humanos , Feminino , Pessoa de Meia-Idade , Infarto do Miocárdio sem Supradesnível do Segmento ST/diagnóstico , Sistemas Automatizados de Assistência Junto ao Leito , Infarto do Miocárdio/diagnóstico , Estudos Prospectivos , Biomarcadores , Troponina I , Algoritmos , Troponina T
2.
Clin Biochem ; 91: 16-25, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33636187

RESUMO

BACKGROUND: Combining high-sensitivity cardiac troponin (hs-cTn) with estimated glomerular filtration rate and glucose within the Clinical Chemistry Score (CCS) could help in the assessment of patients with suspected acute myocardial infarction (AMI). METHODS: In patients presenting with suspected AMI to the emergency department, we aimed to externally validate the performance of the CCS in a prospective international multicenter study and to directly compare the diagnostic and prognostic performance of the CCS with hs-cTnT and hs-cTnI baseline levels alone using a single cut-off approach. The diagnostic endpoint was diagnostic accuracy for AMI as centrally adjudicated by two independent cardiologists including cardiac imaging and serial hs-cTnT/I measurements. The prognostic endpoint was 30-day AMI or death. RESULTS: AMI was the final diagnosis in 620/3827 patients (16.2%) adjudicated with hs-cTnT and 599 patients (15.7%) adjudicated with hs-cTnI. The CCS resulted in high diagnostic accuracy for AMI and prognostic accuracy for 30-days AMI/death as quantified by the area under the receiver-operating characteristic curve (AUC), using hs-cTnT 0.90 (95%CI 0.89-0.91) and 0.89 (95%CI 0.88-0.90), using hs-cTnI 0.91 (95%Cl 0.90-0.92) and 0.90 (95%CI 0.89-0.91) respectively. E.g. a CCS of 0 points resulted in a sensitivity of 99.8% (95%CI 99.1-100%) for rule-out of index AMI and 99.5% (95%CI 98.5-100%) for AMI/death at 30 days for hs-cTnT and 99.8% (95%CI 98.9-100%) and 99.6% (95%CI 98.6-100%) using hs-cTnI. Overall, the single hs-cTnT/I measurement approach provided comparable diagnostic (sensitivity 99.5-99.7%) and prognostic (sensitivity 98.9-99.5%) performance versus the CCS. INTERPRETATION: The CCS provided high diagnostic and prognostic performance also in this independent large validation cohort. A single hs-cTnT/I measurement approach for rule-out MI yielded similar estimates.


Assuntos
Infarto do Miocárdio/sangue , Infarto do Miocárdio/mortalidade , Troponina C/sangue , Adulto , Idoso , Idoso de 80 Anos ou mais , Intervalo Livre de Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Taxa de Sobrevida