Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Forensic Sci Int ; 329: 111084, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34752997

RESUMO

This work presents two simple methods for estimating the firing distance from the gunshot residues (GSRs) on fabric targets. Four types of fabric targets, namely twill weave denim cotton-polyester (80/20), jersey knitting 100% cotton, plain weave cotton-polyester (80/20) and plain weave cotton-polyester (60/40), were employed. The firing tests were carried out using these white fabrics as targets at distances of 5-100 cm, respectively. In the first method, digital images of the black GSRs on fabric materials were recorded inside an illuminated box and the inverted gray intensity values were plotted against the firing distances. Since the plots of all fabrics are not significantly different, the estimation of firing distance employs the same exponential curve for all test fabrics. Although simple, the imaging method is not suitable for dark-colored materials. A chemical-based method was therefore developed as an alternative method. In the second method, a small disposable microfluidic paper-based analytical device (µPAD) was employed for detecting Pb(II) extracted from the GSRs. The µPAD method uses the measurement of the length of a narrow band of a pink color resulting from reaction between rhodizonate reagent and the Pb(II) extract. The plots indicated that the data of thick denim material are significantly different to other test fabrics which are much thinner. These three fabrics share the same estimation curve. However, it is recommended that the separate estimation curve for denim materials must be used. Both methods are suitable for short range firing distance, no further than 60 cm, since at greater distances the inverted gray intensity and the 'band-length' methods are unable to detect the GSRs.

2.
Analyst ; 146(5): 1579-1589, 2021 Mar 08.
Artigo em Inglês | MEDLINE | ID: mdl-33599651

RESUMO

This work presents the first planar three-electrode electrochemical sensor comprising local gold leaf as the working electrode and printed, or hand-drawn, counter and reference electrodes, respectively. The gold leaf was mounted on a polyvinyl chloride (PVC) adhesive sheet (15 mm × 30 mm) and covered with a second PVC sheet printed with the counter and reference electrodes. This sheet has a 3 mm circle and a 2 mm × 3 mm rectangle removed to expose the gold electrode area and electrical contacts, respectively. A third shorter insulating layer with a 10 mm circular hole was placed on top to delineate the sensing area of all electrodes. The sensor displayed expected performances in various modes of operation, such as cyclic voltammetry, square wave voltammetry and anodic stripping voltammetry. For the latter mode, the limit of detection of Pb(ii) was 3.2 µg L-1, compliant with regulation for drinking water (10 µg L-1 Pb(ii)). Although designed as a disposable unit, the electrode is effective for up to 200 cycles and applicable for multiple use. The gold leaf was modified by electrodeposition of the gold network and large nano-size gold particles which significantly enhanced the sensitivity of all voltametric sensing, giving lower limits of detection. For stripping voltammetry, the electroplating structure modification improved the simultaneous detection of lead and copper, with the copper response increasing 6-fold. The device has the capability of on-site identification of copper/lead bullets from gunshot residues within 6 min.

3.
ACS Omega ; 4(12): 15249-15254, 2019 Sep 17.
Artigo em Inglês | MEDLINE | ID: mdl-31552371

RESUMO

Reagent-deposited pieces of paper were characterized by the use of a compact conductometer, a compact pH sensor, and a conventional spectrophotometer to assess their suitability for use as reagent containers. The pieces of paper were fabricated by wax printing to form a limited hydrophilic area to which a consistent volume of an aqueous reagent could be added. The pieces of paper without the reagent increased the conductivity of water gradually because of the release of sodium salts, whereas pH of NaOH decreased because of the acidity of the functional groups in the paper. Three reagents, sulfamic acid as an acid, Na2CO3 as a base, and BaCl2 as a metal salt, were deposited on the pieces of paper to evaluate their ability to release from the pieces of paper. Sulfamic acid and Na2CO3 were released in quantities of 58 and 73% into water after 420 s, whereas 100% of BaCl2 was released after 480 s. The conductometric titrations of NaOH, HCl, and Na2SO4, and the spectrophotometry of Fe2+ were examined using the pieces of paper that contained sulfamic acid, Na2CO3, BaCl2, and 1,10-phenanthroline. Titrations using the pieces of paper suggested that the reagents were quantitatively released into the titrant, which resulted in a linear relationship between the endpoints and the equivalent points. In 120 s of soaking time, 60-70% of the reagents were released. The spectrophotometric measurements of Fe2+ indicated that when an excess amount of the reagents was deposited onto the pieces of paper, they nonetheless sufficiently fulfilled the role of a reagent container.

4.
Talanta ; 188: 74-80, 2018 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-30029441

RESUMO

In flow analysis, such as flow injection analysis, liquid lens is formed at the boundary between two adjacent liquid media which have different refractive indices. Light refraction at the liquid interface gives the so-called 'schlieren signal'. Schlieren effect is both concentration-dependent and temperature-dependent. In this work, the schlieren signal from temperature difference was quantitatively investigated for application in enthalpimetric measurement. The schlieren phenomena was then exploited for chemical analysis. A thermal insulated single flow line manifold was constructed using deionized water at 23 °C as the carrier. Deionized water at various temperatures in the range of 5-85 °C was injected into the carrier flow. A correlation between the schlieren signal and sample temperature was observed. A heat exchanger unit (HEU), consisting of a small volume glass-reaction chamber with a surrounding water jacket, was constructed. The unit was thermally insulated in a double layer cylindrical PVC unit. For demonstrating the applicability of temperature-dependent schlieren effect in chemical analysis, the exothermic oxidation reaction between acid dichromate and ethanol or ascorbic acid was employed with heat transferring to the surrounding water layer. When an aliquot of water from the HEU is injected into the constant temperature flow line the observed schlieren signal was dependent on the analyte concentration. Linear calibration (r2 > 0.99) were obtained covering the concentration range of ethanol and ascorbic acid as found in samples. The developed flow system provides good precision (RSD < 5%) with sample throughput of 4 sample h-1. The system were applied to the determination of ethanol in Thai white spirit and ascorbic acid in vitamin C tablets, respectively. The quantitative results obtained from the schlieren method were in agreement with the comparative methods.

5.
Anal Sci ; 34(1): 83-89, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29321464

RESUMO

A low-cost and user-friendly microfluidic paper-based analytical device (µPAD) was developed for identification of bullet hole from gunshot residue (GSR) on cotton fabric target. The device (25 × 82 mm) is made of filter paper with a printed pattern consisting of a circular sample loading reservoir (6 mm i.d.), a circular waste reservoir (4 mm i.d.) and a straight flow channel (3 mm wide and 60 mm long). A sticker with a ruler scale in millimeters was mounted alongside the channel. The straight channel is first impregnated with rhodizonate and dried at ambient temperature. Tartrate extract of the target fabric is loaded on the sample reservoir. If Pb(II) ions are present in the extract, pink streak of Pb(II)-rhodizonate precipitate is formed as the sample solution flows from the reservoir along the channel. The length of the pink strip is employed to estimate the firing distance.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA