Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Nucl Med ; 65(5): 700-707, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38548353

RESUMO

Patients with HER2-low metastatic breast cancer (mBC), defined as an immunohistochemistry (IHC) score of 1+ or 2+ without HER2 gene amplification, may benefit from HER2 antibody-drug conjugates. Identifying suitable candidates is a clinical challenge because of spatial and temporal heterogeneity in HER2 expression and discrepancies in pathologic reporting. We aimed to investigate the feasibility and safety of HER2-specific PET imaging with [68Ga]Ga-ABY-025 for visualization of HER2-low mBC. Methods: A prospective pilot study was done with 10 patients who had HER2-low mBC, as part of a phase 2 basket imaging study with [68Ga]Ga-ABY-025 in HER2-expressing solid tumors. Patients were recruited at the Breast Clinic at the Karolinska University Hospital, Stockholm, Sweden. PET/CT images were acquired 3 h after injection of 200 MBq of [68Ga]Ga-ABY-025. The SUVmax was used to quantify tracer uptake. Ultrasound-guided tumor biopsies were guided by results from the HER2 PET. The main outcome-the safety and feasibility of HER2 PET in patients with HER2-low mBC, measured the occurrence of possible procedure-related adverse events. Results: Ten patients with HER2-low mBC underwent [68Ga]Ga-ABY-025 PET/CT with paired tumor biopsies. No adverse events occurred. In all patients, [68Ga]Ga-ABY-025-avid lesions with substantial intra- and interindividual heterogeneity in tracer uptake were noted. In 8 of 10 patients with ABY-025-avid lesions, the HER2-low status of the corresponding lesions was confirmed by IHC or in situ hybridization. Two patients had an IHC score of 0 in the tumor biopsies:1 in a cutaneous lesion with a low SUVmax and 1 in a liver metastasis with a high SUVmax but a "cold" core. Conclusion: The visualization of HER2-low mBC with [68Ga]Ga-ABY-025 PET/CT was feasible and safe. Areas of tracer uptake showed varying levels of HER2 expression on IHC. The observed intra- and interindividual heterogeneity in [68Ga]Ga-ABY-025 uptake suggested that HER2 PET might be used as a tool for the noninvasive assessment of disease heterogeneity and has the potential to identify patients in whom HER2-targeted drugs can have a clinical benefit.


Assuntos
Neoplasias da Mama , Fragmentos de Peptídeos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Receptor ErbB-2 , Proteína Estafilocócica A , Humanos , Projetos Piloto , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/metabolismo , Receptor ErbB-2/metabolismo , Feminino , Pessoa de Meia-Idade , Idoso , Radioisótopos de Gálio , Adulto , Estudos Prospectivos , Compostos Radiofarmacêuticos , Tomografia por Emissão de Pósitrons
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA