Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
Clin Appl Thromb Hemost ; 28: 10760296221074347, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35043712

RESUMO

Acute pulmonary embolism (PE) is a common emergency with a high morbidity and mortality. Most clinical presentations are non-specific and there is a lack of suitable biomarkers for PE. For example, the traditional D-dimer tests shows a rather high sensitivity for PE, but yet a rather low positive predictive value due to its lack of specificity. Research on novel biomarkers for PE is thus of interest to improve early diagnostics and reduce the number of unnecessary computed tomography pulmonary angiogram (CTPA) scans performed. In this study we evaluate the feasibility to use label-free quantitative proteomics to discover potential biomarkers for acute PE and to monitor changes in proteins levels in PE patients over time. Blood was collected from 8 patients with CTPA verified PE and from 8 patients presenting with same symptoms but with a negative CTPA. The samples were analyzed by liquid chromatography-mass spectrometry and thirteen protein concentrations were found to be significantly changed in PE patients compared to the CTPA negative controls. This exploratory study shows that proteomic analysis can be used to identify potential biomarkers for PE as well as to monitor changes of protein levels over time.The complement proteins play a part in PE but further studies are needed to clarify their specific role in the pathophysiological process and to look for more specific proteins.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio/metabolismo , Proteômica/métodos , Embolia Pulmonar/sangue , Doença Aguda , Adulto , Idoso , Biomarcadores/sangue , Angiografia por Tomografia Computadorizada/métodos , Estudos de Viabilidade , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Embolia Pulmonar/diagnóstico , Embolia Pulmonar/epidemiologia , Fatores de Risco
2.
Proteomes ; 6(4)2018 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-30340394

RESUMO

Plasma biomarkers that identify abdominal aortic aneurysm (AAA) rupture risk would greatly assist in stratifying patients with small aneurysms. Identification of such biomarkers has hitherto been unsuccessful over a range of studies using different methods. The present study used an alternative proteomic approach to find new, potential plasma AAA biomarker candidates. Pre-fractionated plasma samples from twelve patients with AAA and eight matched controls without aneurysm were analyzed by mass spectrometry applying a tandem mass tag (TMT) technique. Eight proteins were differentially regulated in patients compared to controls, including decreased levels of the enzyme bleomycin hydrolase. The down-regulation of this enzyme was confirmed in an extended validation study using an enzyme-linked immunosorbent assay (ELISA). The TMT-based proteomic approach thus identified novel potential plasma biomarkers for AAA.

3.
Adv Biosyst ; 2(5): e1800019, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-33103858

RESUMO

Antibacterial agents based on nanoparticles (NPs) have many important applications, e.g., for the textile industry, surface disinfection, wound dressing, water treatment, and food preservation. Because of their prevalent use it is important to understand whether bacteria could develop resistance to such antibacterial NPs similarly to the resistance that bacteria are known to develop to antibiotics. Here, it is reported that Escherichia coli (E. coli) develops adaptive resistance to antibacterial ZnO NPs after several days' exposure to the NPs. But, in contrast to antibiotics-resistance, the observed resistance to ZnO NPs is not stable-after several days without exposure to the NPs, the bacteria regain their sensitivity to the NPs' antibacterial properties. Based on the analyses it is suggested that the observed resistance is caused by changes in the shape of the bacteria and the expressions of membrane proteins. The findings provide insights into the response of bacteria to antibacterial NPs, which is important to elucidate for designing and evaluating the risk of applications based on antibacterial NPs.

4.
J Sep Sci ; 40(7): 1482-1492, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28145078

RESUMO

We developed a straightforward, robust, and relatively fast method for the analysis of amino acids by mixed-mode high-performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The method does not involve derivatization and allows the detection of 21 amino acids, representing a wide range of isoelectric points, in less than 40 min. Chromatographic separation was governed by a silica-based mixed-mode column providing simultaneous hydrophobic and ion exchange separation mechanisms. The use of tandem mass spectrometry increased selectivity, reducing potential problems associated with poor selectivity in the chromatographic system. For an injection volume of 1 µL, we obtained detection limits <3 µM for the majority of analytes. For all analytes, a linearity of r > 0.99 was obtained, recovery in matrix was >86%, and the retention times were highly reproducible. The method was successfully applied to soil solution and fungal culture samples, demonstrating the advantages in successfully avoiding issues associated with high amounts of substances that may interfere with derivatization-based methods. This method represents an alternative to derivatization-based methods and can be applied in areas where sample matrices are highly complex.


Assuntos
Aminoácidos/análise , Técnicas de Química Analítica/métodos , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas em Tandem , Técnicas de Química Analítica/instrumentação , Limite de Detecção , Espectrometria de Massas por Ionização por Electrospray
5.
Int J Anal Chem ; 2016: 9269357, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26977151

RESUMO

This method employs liquid chromatography-tandem mass spectrometry to rapidly quantify chitin-derived glucosamine for estimating fungal biomass. Analyte retention was achieved using hydrophilic interaction liquid chromatography, with a zwitter-ionic stationary phase (ZIC-HILIC), and isocratic elution using 60% 5 mM ammonium formate buffer (pH 3.0) and 40% ACN. Inclusion of muramic acid and its chromatographic separation from glucosamine enabled calculation of the bacterial contribution to the latter. Galactosamine, an isobaric isomer to glucosamine, found in significant amounts in soil samples, was also investigated. The two isomers form the same precursor and product ions and could not be chromatographically separated using this rapid method. Instead, glucosamine and galactosamine were distinguished mathematically, using the linear relationships describing the differences in product ion intensities for the two analytes. The m/z transitions of 180 → 72 and 180 → 84 were applied for the detection of glucosamine and galactosamine and that of 252 → 126 for muramic acid. Limits of detection were in the nanomolar range for all included analytes. The total analysis time was 6 min, providing a high sample throughput method.

6.
Am J Cardiovasc Dis ; 5(3): 140-5, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26417533

RESUMO

Abdominal aortic aneurysm (AAA) is a common condition with high mortality when ruptured. Most clinicians agree that small AAAs are best managed by ultrasonographic surveillance. However, it has been stated in recent reviews that a serum/plasma biomarker that predicts AAA rupture risk would be a powerful tool in stratifying patients with small AAAs. Identification of such circulating biomarkers with traditional hypothesis driven studies has been unsuccessful. In this review we summarize six studies using different proteomic approaches to find new, potential plasma AAA biomarker candidates. In conclusion, by using proteomic approaches novel potential plasma biomarkers for AAA have been identified.

7.
J Sep Sci ; 38(19): 3305-12, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26179786

RESUMO

A liquid chromatography with electrospray ionization mass spectrometry method was developed to quantitatively and qualitatively analyze 13 hydroxamate siderophores (ferrichrome, ferrirubin, ferrirhodin, ferrichrysin, ferricrocin, ferrioxamine B, D1 , E and G, neocoprogen I and II, coprogen and triacetylfusarinine C). Samples were preconcentrated on-line by a switch-valve setup prior to analyte separation on a Kinetex C18 column. Gradient elution was performed using a mixture of an ammonium formate buffer and acetonitrile. Total analysis time including column conditioning was 20.5 min. Analytes were fragmented by applying collision-induced dissociation, enabling structural identification by tandem mass spectrometry. Limit of detection values for the selected ion monitoring method ranged from 71 pM to 1.5 nM with corresponding values of two to nine times higher for the multiple reaction monitoring method. The liquid chromatography with mass spectrometry method resulted in a robust and sensitive quantification of hydroxamate siderophores as indicated by retention time stability, linearity, sensitivity, precision and recovery. The analytical error of the methods, assessed through random-order, duplicate analysis of soil samples extracted with a mixture of 10 mM phosphate buffer and methanol, appears negligible in relation to between-sample variations.

8.
J Mass Spectrom ; 49(7): 550-6, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25044839

RESUMO

Conditional stability constants of coordination complexes comprising divalent transition metals, Cu(2+), Ni(2+), Zn(2+), Co(2+), and ethylenediaminetetraacetic acid (EDTA) were determined utilizing electrospray ionization mass spectrometry. The deviation of signal response of a reference complex was monitored at addition of a second metal ion. The conditional stability constant for the competing metal was then determined through solution equilibria equations. The method showed to be applicable to a system where Co(2+) and Zn(2+) competed for EDTA at pH 5. When Cu(2+) and Ni(2+) competed for EDTA, the equilibrium changed over time. This change was shown to be affected in rate and size by the type of organic solvent added. In this work, 30% of either methanol or acetonitrile was used. It was found that if calibration curves are prepared for both metal complexes in solution and the measurements are repeated with sufficient time space, any change in equilibrium of sample solutions will be discovered.

9.
Langmuir ; 30(16): 4605-12, 2014 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-24702119

RESUMO

Coordination complexes of some divalent metal ions with the DTPA (diethylenetriaminepentaacetic acid)-based chelating surfactant 2-dodecyldiethylenetriaminepentaacetic acid (4-C12-DTPA) have been examined in terms of chelation and solution behavior. The headgroup of 4-C12-DTPA contains eight donor atoms that can participate in the coordination of a metal ion. Conditional stability constants for five transition metal complexes with 4-C12-DTPA were determined by competition measurements between 4-C12-DTPA and DTPA, using electrospray ionization mass spectrometry (ESI-MS). Small differences in the relative strength between the coordination complexes of DTPA and 4-C12-DTPA indicated that the hydrocarbon tail only affected the chelating ability of the headgroup to a limited extent. The coordination of Cu(2+) ions was investigated in particular, using UV-visible spectroscopy. By constructing Job's plots, it was found that 4-C12-DTPA could coordinate up to two Cu(2+) ions. Surface tension measurements and NMR diffusometry showed that the coordination of metal ions affected the solution behavior of 4-C12-DTPA, but there were no specific trends between the studied divalent metal complexes. Generally, the effects of the metal ion coordination could be linked to the neutralization of the headgroup charge of 4-C12-DTPA, and the resulting reduced electrostatic repulsions between adjacent surfactants in micelles and monolayers. The pH vs concentration plots, on the other hand, showed a distinct difference between 4-C12-DTPA complexes of the alkaline earth metals and the transition metals. This was explained by the difference in coordination between the two groups of metal ions, as predicted by the hard and soft acid and base (HSAB) theory.

10.
Anal Chim Acta ; 704(1-2): 180-8, 2011 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-21907036

RESUMO

A strategy for rapid optimization of liquid chromatography column temperature and gradient shape is presented. The optimization as such is based on the well established retention and peak width models implemented in software like e.g. DryLab and LC simulator. The novel part of the strategy is a highly automated processing algorithm for detection and tracking of chromatographic peaks in noisy liquid chromatography-mass spectrometry (LC-MS) data. The strategy is presented and visualized by the optimization of the separation of two degradants present in ultraviolet (UV) exposed fluocinolone acetonide. It should be stressed, however, that it can be utilized for LC-MS analysis of any sample and application where several runs are conducted on the same sample. In the application presented, 30 components that were difficult or impossible to detect in the UV data could be automatically detected and tracked in the MS data by using the proposed strategy. The number of correctly tracked components was above 95%. Using the parameters from the reconstructed data sets to the model gave good agreement between predicted and observed retention times at optimal conditions. The area of the smallest tracked component was estimated to 0.08% compared to the main component, a level relevant for the characterization of impurities in the pharmaceutical industry.


Assuntos
Algoritmos , Técnicas de Química Analítica , Cromatografia Líquida de Alta Pressão/métodos , Fluocinolona Acetonida , Espectrometria de Massas/métodos , Automação Laboratorial , Estabilidade de Medicamentos , Fluocinolona Acetonida/análogos & derivados , Fluocinolona Acetonida/análise , Luz , Software , Soluções
11.
J Chromatogr A ; 1217(52): 8195-204, 2010 Dec 24.
Artigo em Inglês | MEDLINE | ID: mdl-21081230

RESUMO

A method for tracking of sample components during liquid chromatography-mass spectrometry (LC-MS) method development has been proposed. The method manages to, fully automatically and without user intervention, find the chromatographic peaks in the data sets, discriminate them to sample components and track them when the separation conditions have been changed. The algorithm utilises the resolution obtained from all considered data sets and has the ability to discriminate the non informative parts. The technique has a great sensitivity even in cases where a majority of the tracked components cannot easily be spotted by means of traditional total ion chromatogram (TIC) or base peak chromatogram (BPC) representations. The method was tested on an experimental sample using six different columns and an average of 79% of the suggested sample components could be successfully tracked at a minimum area of 0.05% of the main component in the sample. 66 components with 79-92% of the total suggested component area were able to be tracked between all data sets. The method could be used to rapidly investigate selectivity during different types of separation conditions.


Assuntos
Algoritmos , Cromatografia Líquida de Alta Pressão/instrumentação , Espectrometria de Massas/instrumentação , Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos
12.
J Sep Sci ; 32(22): 3906-18, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19882622

RESUMO

A highly automated procedure for localising and characterising peaks in the chromatographic time domain of LC-MS data has been developed. The work was initiated by an identified need to facilitate the detection and tracking of chromatographic peaks during method development for the analysis of impurities in pharmaceutical products. The algorithm is mainly based on a digital filter for which the settings are automatically adapted to the data set under study. The procedure was evaluated for synthetic data sets with various S/N levels, peak widths and baseline properties. It was found that even for the worst case tested with S/N=10 and a high variability in the baseline, 94% of the simulated analytical peaks could be detected without producing any false-positive identifications. Furthermore, the number of correctly estimated peak heights and peak widths falling within a 10% error of the true values were 94 and 91%, respectively. For experimental data sets, peak height, and width estimations were more difficult, but the processed reconstructions showed an excellent agreement with the analytical signals of the raw data, and also a clearly improved visualisation in total ion- and base-peak chromatograms.


Assuntos
Automação , Cromatografia Líquida/métodos , Espectrometria de Massas/métodos , Algoritmos
13.
J Chromatogr A ; 1176(1-2): 89-93, 2007 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-18001753

RESUMO

A sensitive and selective method for the analysis of aliphatic low molecular mass organic acids (LMMOAs) in natural waters is presented. The method is based on separation with ion exclusion chromatography and detection with electrospray ionization tandem mass spectrometry (LC-MS/MS). The extra selectivity gained by applying MS/MS allows for a minimum of sample preparation and the use of a sub-optimal mobile phase regarding chromatographic resolution. Instead the mobile phase, comprising aqueous formic acid with methanol as organic modifier, was mainly optimized for maximum sensitivity and long term MS stability. Detection limits for malonic, fumaric, maleic, succinic, citraconic, glutaric, malic, alpha-ketoglutaric, tartaric, shikimic, trans-aconitic, cis-aconitic, isocitric and citric acid were in the range 1-50 nM, while the detection limits for pyruvic, oxalic and lactic acid were around 250 nM for an injection volume of 100 microL. Due to their metal-chelating properties, these LMMOAs are all considered to affect the bioavailability of metals and to be involved in soil forming processes. It is thus of interest to be able to monitor their presence in natural waters, and the method developed within this work was successfully applied for the analysis of LMMOAs in soil solution and stream water samples.


Assuntos
Ácidos/análise , Cromatografia em Gel/métodos , Compostos Orgânicos/análise , Espectrometria de Massas em Tandem/métodos , Água/química , Peso Molecular , Sensibilidade e Especificidade
14.
J Chromatogr A ; 1172(2): 135-50, 2007 Nov 23.
Artigo em Inglês | MEDLINE | ID: mdl-17959187

RESUMO

Four data pre-processing methods have been applied with different settings to data sets obtained from the analysis of a pharmaceutical drug and its degradation products by liquid chromatography-mass spectrometry (LC-MS). The methods compared were the frequently used component detection algorithm (CODA) and three kinds of digital filters--matched filtration (MF), Gaussian second derivative (GSD) and Savitzky-Golay. The aim was to evaluate the performance and robustness of these methods for extracted ion chromatogram (XIC), total ion chromatogram (TIC) and base peak chromatogram (BPC) in the presence of different types of noise. In accordance with theory, the best improvements in signal-to-noise ratio (S/N) of the XICs were obtained with MF under the ideal case with random white noise. However, when highly coloured noise was present, it was found that no improvements in XIC S/N could be obtained with any of the pre-processing methods studied. GSD and CODA did, however, improve the S/N for both TIC and BPC. GSD and CODA also significantly reduced the background in the spectral domain, thereby facilitating the interpretation of the mass spectra. Another advantage associated with CODA and to some extent also with GSD is their data reduction ability.


Assuntos
Algoritmos , Interpretação Estatística de Dados , Processamento de Sinais Assistido por Computador/instrumentação , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão , Análise de Fourier , Preparações Farmacêuticas , Análise de Regressão , Reprodutibilidade dos Testes , Espectrometria de Massas por Ionização por Electrospray/estatística & dados numéricos , Espectrofotometria Ultravioleta/métodos , Espectrometria de Massas em Tandem/estatística & dados numéricos
15.
Appl Environ Microbiol ; 73(18): 5857-64, 2007 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-17675442

RESUMO

The siderophore production of the facultative anaerobe Pseudomonas stutzeri, strain CCUG 36651, grown under both aerobic and anaerobic conditions, was investigated by liquid chromatography and mass spectrometry. The bacterial strain has been isolated at a 626-m depth at the Aspö Hard Rock Laboratory, where experiments concerning the geological disposal of nuclear waste are performed. In bacterial culture extracts, the iron in the siderophore complexes was replaced by gallium to facilitate siderophore identification by mass spectrometry. P. stutzeri was shown to produce ferrioxamine E (nocardamine) as the main siderophore together with ferrioxamine G and two cyclic ferrioxamines having molecular masses 14 and 28 atomic mass units lower than that of ferrioxamine E, suggested to be ferrioxamine D(2) and ferrioxamine X(1), respectively. In contrast, no siderophores were observed from anaerobically grown P. stutzeri. None of the siderophores produced by aerobically grown P. stutzeri were found in anaerobic natural water samples from the Aspö Hard Rock Laboratory.


Assuntos
Aerobiose , Anaerobiose , Pseudomonas stutzeri/metabolismo , Sideróforos/biossíntese , Regulação Bacteriana da Expressão Gênica , Pseudomonas stutzeri/genética , Pseudomonas stutzeri/crescimento & desenvolvimento , Sideróforos/química , Sideróforos/metabolismo
16.
J Mass Spectrom ; 41(10): 1334-45, 2006 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17016860

RESUMO

The feasibility and advantages of using sophisticated chemometric tools in combination with the execution of thoroughly planned experiments to determine experimental conditions for optimal performance of an LC-ESI-MS/MS analysis is demonstrated. A stepwise strategy is proposed, which provides a controlled optimization procedure of the chromatographic quality (in terms of separation among the sample constituents) and maximizes the mass spectrometric signal of the selected product ions. Design of experiments (DOE) and response surface methodology are applied throughout the procedure. The stepwise approach has the advantage of dealing with the different optimization criteria separately, i.e. first ensuring sufficient chromatographic separation, then maximizing the amount of precursor ion entering the mass spectrometer, and finally generating high amounts of selected product ions. The experiments are performed on a linear ion trap mass spectrometer. Retention mapping using the band-tracking model is applied during LC development, which facilitates the optimization of segmented gradients. A set of different siderophores, strong iron chelates, is used as the model substances.

17.
Biometals ; 19(3): 269-82, 2006 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-16799865

RESUMO

Concentrations up to 2 and 12 nM of the hydroxamate siderophores ferrichrome and ferricrocin, respectively, were identified in soil solutions of podzolic forest soils at four sites in both northern and southern Sweden. No ferrichrysin was detected. As with the dissolved organic carbon and low molecular mass organic acids, the highest concentrations of the siderophores were found in the upper layers i.e. the mor layer, the eluvial and upper illuvial horizons. At the southern sites, the concentrations of ferrichrome and ferricrocin were both of similar magnitude and did not differ between the two sites. In contrast, soil solutions at the two northern sites contained more ferricrocin than ferrichrome; the ferricrocin concentrations were also higher at the northern sites than at the southern sites. Analyses were performed by high performance liquid chromatography with a porous graphitic carbon column on which ferrichrome, ferricrocin and ferrichrysin were separated. Detection by electrospray ionization mass spectrometry (ESI-MS) combined with on-line sample pre-concentration, by means of column-switching, enabled detection limits of 0.1-0.2 nM for ferrichrome, ferrichrysin and ferricrocin. The structural identities of the siderophores were further verified by MS/MS fragmentation. Fragmentation of ferrichrome, ferricrocin and ferrichrysin occurred mainly via peptide cleavage. The most intense fragments were typified by the loss of one of the three iron(III) chelating hydroxamate residues, i.e N(5)-acyl-N(5)-hydroxy ornithine.


Assuntos
Ferricromo/análogos & derivados , Ferricromo/análise , Sideróforos/análise , Solo/análise , Cromatografia Líquida de Alta Pressão , Espectrometria de Massas por Ionização por Electrospray , Suécia
18.
J Am Soc Mass Spectrom ; 17(3): 318-24, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16442303

RESUMO

Ions that are observed in a mass spectrum obtained with electrospray mass spectrometry can be assumed to originate preferentially from ions that have a high distribution to the surface of the charged droplets. In this study, a relation between chromatographic retention and electrophoretic mobility to the ion distribution (derived from measured signal intensities in mass spectra and electrospray current) within electrosprayed droplets for a series of tetraalkylammonium ions, ranging from tetramethyl to tetrapentyl, is presented. Chromatographic retention in a reversed-phase system was taken as a measure of the analyte's surface activity, which was found to have a large influence on the ion distribution within electrosprayed droplets. In addition, different transport mechanisms such as electrophoretic migration and diffusion can influence the surface partitioning coefficient. The viscosity of the solvent system is affected by the methanol content and will influence both diffusion and ion mobility. However, as diffusion and ion mobility are proportional to each other, we have, in this study, chosen to focus on the ion mobility parameter. It was found that the influence of ion mobility relative to surface activity on the droplet surface partitioning of analyte ions decreases with increasing methanol content. This effect is most probably coupled to the decrease in droplet size caused by the decreased surface tension at increasing methanol content. The same observation was made upon increasing the ionic strength of the solvent system, which is also known to give rise to a decreased initial droplet size. The observed effect of ionic strength on the droplet surface partitioning of analyte ions could also be explained by the fact that at higher ionic strength, a larger number of ions are initially closer to the droplet surface and, thus, the contribution of ionic transport from the bulk liquid to the liquid/air surface interface (jet and droplet surface), attributable to migration or diffusion will decrease.


Assuntos
Cromatografia Líquida/métodos , Coloides/análise , Coloides/química , Eletroforese/métodos , Modelos Químicos , Espectrometria de Massas por Ionização por Electrospray/métodos , Misturas Complexas/análise , Misturas Complexas/química , Simulação por Computador , Íons , Soluções
19.
J Mass Spectrom ; 40(3): 317-24, 2005 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-15674864

RESUMO

The feasibility of experimental design in combination with subsequent response surface modelling was illustrated for the prediction and interpretation of tandem mass spectrometric (MS/MS) fragmentation data using a linear quadrupole ion trap under various experimental conditions. The instrumental parameters included were (i) the pressure of the collision gas, (ii) the collision energy, (iii) the fill time of the linear ion trap and (iv) the scan rate. The spectral intensity and width of five fragment ions of the doubly charged neuro-active peptide bombesin were used for evaluation, and all experiments were performed so as to resemble the results obtained from a liquid chromatographic peak. The reported results show how fairly simple mathematical tools can be utilized successfully to describe fundamental mechanisms associated with multiple collisional activation and collision-induced dissociation processes without an extensively controlled experimental environment. Most beneficial, using the suggested approach, is the ability to study interaction (synergistic) effects between various parameters. As was realized from the results, many interaction effects are indeed significant. For example, the effect on the signal intensity of different collision gas pressure settings is strongly dependent on the settings of the other parameters. The described approach can easily be adopted for optimization purposes of any MS/MS experiment.

20.
Electrophoresis ; 25(13): 2100-2107, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15237411

RESUMO

A chemometrics approach has been used for evaluating the effect of four experimental parameters when coupling capillary electrophoresis (CE) to electrospray ionization-mass spectrometry (ESI-MS). Electrospray voltage, sheath-liquid flow rate, nebulizing gas flow rate, and spray needle position in respect to the MS orifice were varied according to a full factorial design. In addition to main effects, two interaction effects could be identified as significant when measuring the peak intensity of the analytes, from a sample mixture containing peptides and pharmaceuticals. The first interaction effects, between the nebulizing gas flow rate and the sheath-liquid flow rate, and the second interaction effect, between the nebulizing gas flow rate and the spray position, could further explain the impact that these variables have on the spray performance. The number of theoretical plates and the baseline noise were also measured. The sheath-liquid flow was found to significantly affect the separation efficiency, while the noise level mainly was controlled by the nebulizing gas flow. The same factorial design was also used for a CE capillary with lower internal diameter (ID) and the effects of the same variables were compared on those capillaries using equal injection volume for both capillaries. Similar trends were obtained in both capillaries but capillary ID was shown to be a significant variable when evaluating both capillaries in a single model. It was found that a capillary with 25 microm ID provided improved CE-MS performance over than corresponding 50 microm ID capillary. Enhanced sensitivity was obtained using the narrow-bore capillary, and at lower sheath-liquid flow rate the 25 microm ID capillary also gave rise to more efficient peaks.


Assuntos
Eletroforese Capilar/métodos , Espectrometria de Massas por Ionização por Electrospray/métodos , Eletroforese Capilar/instrumentação , Nebulizadores e Vaporizadores , Ruído , Peptídeos/análise , Peptídeos/química , Preparações Farmacêuticas/análise , Preparações Farmacêuticas/química , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA