Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 47
Filtrar
2.
Gastroenterol Hepatol ; 47(3): 246-252, 2024 Mar.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-37236304

RESUMO

BACKGROUND AND OBJECTIVES: There are few scales with prospective validation for the assessment of the upper gastrointestinal mucosal cleanliness during an esophagogastroduodenoscopy (EGD). The aim of this study was to develop a valid and reproducible cleanliness scale for use during an EGD. METHODS: We developed a cleanliness scale (Barcelona scale) with a score (0-2 points) of five segments of the upper gastrointestinal tract with thorough cleaning techniques (esophagus, fundus, body, antrum, and duodenum). First, 125 photos (25 of each area) were assessed, and a score was assigned to each image by consensus among 7 experts endoscopists. Subsequently, 100 of the 125 images were selected and the inter- and intra-observer variability of 15 previously trained endoscopists was evaluated using the same images at two different times. RESULTS: In total, 1500 assessments were performed. In 1336/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.83 (0.45-0.96). In the second evaluation, in 1330/1500 observations (89%) there was agreement with the consensus score, with a mean kappa value of 0.82 (0.45-0.93). The intra-observer variability was 0.89 (0.76-0.99). CONCLUSIONS: The Barcelona cleanliness scale is a valid measure and reproducible with minimal training. Its application in clinical practice is a significant step to standardize the quality of the EGD.


Assuntos
Duodeno , Mucosa , Humanos , Consenso , Endoscopia do Sistema Digestório
3.
Cancers (Basel) ; 15(12)2023 Jun 08.
Artigo em Inglês | MEDLINE | ID: mdl-37370732

RESUMO

BACKGROUND AND AIMS: Colonoscopy is currently the most effective way of detecting colorectal cancer and removing polyps, but it has some drawbacks and can miss up to 22% of polyps. Microwave imaging has the potential to provide a 360° view of the colon and addresses some of the limitations of conventional colonoscopy. This study evaluates the feasibility of a microwave-based colonoscopy in an in vivo porcine model. METHODS: A prototype device with microwave antennas attached to a conventional endoscope was tested on four healthy pigs and three gene-targeted pigs with mutations in the adenomatous polyposis coli gene. The first four animals were used to evaluate safety and maneuverability and compatibility with endoscopic tools. The ability to detect polyps was tested in a series of three gene-targeted pigs. RESULTS: the microwave-based device did not affect endoscopic vision or cause any adverse events such as deep mural injuries. The microwave system was stable during the procedures, and the detection algorithm showed a maximum detection signal for adenomas compared with healthy mucosa. CONCLUSIONS: Microwave-based colonoscopy is feasible and safe in a preclinical model, and it has the potential to improve polyp detection. Further investigations are required to assess the device's efficacy in humans.

4.
Dig Dis Sci ; 68(4): 1447-1454, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36104534

RESUMO

BACKGROUND: Motorized Spiral Enteroscopy (MSE) reduces procedure time and increases insertion depth into the small bowel; however, there is scarce evidence on factors affecting MSE efficacy. AIMS: To evaluate diagnostic yield and adverse events of MSE including patients with prior major abdominal surgery. METHODS: A prospective observational study was conducted on patients undergoing MSE from June 2019 to December 2021. Demographic characteristics, procedure time, depth of maximum insertion (DMI), technical success, diagnostic yield, and adverse events were collected. RESULTS: Seventy-four anterograde (54.4%) and 62 retrograde (45.6%) enteroscopies were performed in 117 patients (64 males, median age 67 years). Fifty patients (42.7%) had prior major abdominal surgery. Technical success was 91.9% for anterograde and 90.3% for retrograde route. Diagnostic yield was 71.6% and 61.3%, respectively. The median DMI was 415 cm (264-585) for anterograde and 120 cm (37-225) for retrograde enteroscopy. In patients with prior major abdominal surgery, MSE showed significantly longer small bowel insertion time (38 vs 29 min, p = 0.004), with similar diagnostic yield (61 vs 71.4%, p = 0.201) and DMI (315 vs 204 cm, p = 0.226). The overall adverse event rate was 10.3% (SAE 1.5%), with no differences related to prior abdominal surgery (p = 0.598). Patients with prior surgeries directly involving the gastrointestinal tract showed lower DMI (189 vs 374 cm, p = 0.019) with equal exploration time (37.5 vs 38 min, p = 0.642) compared to those with other abdominal surgeries. CONCLUSIONS: MSE is effective and safe in patients with major abdominal surgery, although longer procedure times were observed. A lower depth of insertion was detected in patients with gastrointestinal surgery.


Assuntos
Enteropatias , Laparoscopia , Masculino , Humanos , Idoso , Enteropatias/diagnóstico , Endoscopia Gastrointestinal/efeitos adversos , Endoscopia Gastrointestinal/métodos , Estudos Prospectivos , Intestino Delgado/cirurgia , Enteroscopia de Duplo Balão/métodos
5.
Gastroenterol Hepatol ; 46(5): 360-368, 2023 May.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36179948

RESUMO

BACKGROUND: Barrett's esophagus (BE) is an entity with a known histological progression to malignancy. The insulin-like growth factor (IGF) system is involved in the carcinogenesis through obesity-related mechanisms that include IGF and it has been associated with several types of cancer. OBJECTIVES: To evaluate the serological levels of IGF-1 and IGFBP-3 in patients with BE and esophageal adenocarcinoma. PATIENTS AND METHODS: Prospective study of patients with BE and esophageal adenocarcinoma who underwent upper endoscopy between September 2012 and December 2015. A baseline determination of IGF-1 and IGFBP-3 was performed. We included a control group of patients without BE. RESULTS: One hundred sixteen patients were included: 36 controls, 62 with BE (42 without dysplasia and 20 with dysplasia) and 18 with adenocarcinoma. IGF-1 and IGF-1/IGFBP-3 molar ratio showed a progression to high levels in BE and adenocarcinoma than in controls (IGF-1: 135.55±66.07ng/ml, 148.33±81.5ng/ml, 108.19±46.69ng/ml, respectively; P=.049) (molar ratio: 0.23±0.91, 0.29±0.11, 0.19±0.06, respectively; P=.001), without differences between the histological types of BE. Fifty-four out of the 65 patients with BE were followed up (median of 58.50 months, range 12-113) and 11 of them (20.4%) presented progression to low-grade dysplasia (n=8) or high-grade dysplasia/adenocarcinoma (n=3), without differences in the IGF system compared with patients without progression. CONCLUSIONS: Patients with BE and esophageal adenocarcinoma have changes in the IGF system although the serological levels of IGF-1 and IGFBP-3 do not correlate with histological progression of BE.


Assuntos
Adenocarcinoma , Esôfago de Barrett , Neoplasias Esofágicas , Humanos , Esôfago de Barrett/metabolismo , Esôfago de Barrett/patologia , Estudos Longitudinais , Proteína 3 de Ligação a Fator de Crescimento Semelhante à Insulina , Fator de Crescimento Insulin-Like I/metabolismo , Estudos Prospectivos , Progressão da Doença , Neoplasias Esofágicas/patologia , Adenocarcinoma/patologia
6.
Gastroenterol Hepatol ; 46(6): 483-488, 2023.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-36195279

RESUMO

Helicobacter pylori (H. pylori) infection is highly prevalent in our environment and is associated with highly relevant gastric disease, both benign and malignant. The gold standard for diagnosis is histological confirmation by biopsy. However, there is increasing evidence that optical endoscopic diagnosis could have a fundamental role in avoiding unnecessary biopsies in certain cases. Specifically, the regular distribution of the collecting venules (RAC pattern) seems to have a high negative predictive value (NPV) to rule out infection. This review describes the most outstanding endoscopic findings with the best diagnostic potential for H. pylori infection after an exhaustive search comparing the most relevant studies that have been carried out in Europe and the East.


Assuntos
Gastrite , Infecções por Helicobacter , Helicobacter pylori , Humanos , Gastroscopia , Mucosa Gástrica , Gastrite/diagnóstico , Infecções por Helicobacter/diagnóstico , Biópsia
8.
Endosc Int Open ; 10(9): E1201-E1207, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36118638

RESUMO

Background and study aims Artificial intelligence is currently able to accurately predict the histology of colorectal polyps. However, systems developed to date use complex optical technologies and have not been tested in vivo. The objective of this study was to evaluate the efficacy of a new deep learning-based optical diagnosis system, ATENEA, in a real clinical setting using only high-definition white light endoscopy (WLE) and to compare its performance with endoscopists. Methods ATENEA was prospectively tested in real life on consecutive polyps detected in colorectal cancer screening colonoscopies at Hospital Clínic. No images were discarded, and only WLE was used. The in vivo ATENEA's prediction (adenoma vs non-adenoma) was compared with the prediction of four staff endoscopists without specific training in optical diagnosis for the study purposes. Endoscopists were blind to the ATENEA output. Histology was the gold standard. Results Ninety polyps (median size: 5 mm, range: 2-25) from 31 patients were included of which 69 (76.7 %) were adenomas. ATENEA correctly predicted the histology in 63 of 69 (91.3 %, 95 % CI: 82 %-97 %) adenomas and 12 of 21 (57.1 %, 95 % CI: 34 %-78 %) non-adenomas while endoscopists made correct predictions in 52 of 69 (75.4 %, 95 % CI: 60 %-85 %) and 20 of 21 (95.2 %, 95 % CI: 76 %-100 %), respectively. The global accuracy was 83.3 % (95 % CI: 74%-90 %) and 80 % (95 % CI: 70 %-88 %) for ATENEA and endoscopists, respectively. Conclusion ATENEA can accurately be used for in vivo characterization of colorectal polyps, enabling the endoscopist to make direct decisions. ATENEA showed a global accuracy similar to that of endoscopists despite an unsatisfactory performance for non-adenomatous lesions.

9.
Dig Dis ; 40(3): 376-384, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34348294

RESUMO

BACKGROUND: Regular arrangement of collecting venules (RAC) in gastric mucosa accurately identifies patients without Helicobacter pylori (H pylori) infection. The aim of our study was to evaluate the reproducibility of RAC using white light endoscopy without magnification, in a European country, and to assess the impact of proton pump inhibitors (PPIs). METHODS: A multicenter prospective study with image capture of the distal lesser gastric curvature and gastric biopsies was performed. The presence of starfish-like minute points regularly distributed throughout lesser curvature was considered as RAC positive (RAC+). A set of 20 images was used for the training phase and inter and intra-observer agreements were calculated. RESULTS: 174 patients were included and 85 (48.9%) were taking PPIs. Kappa values for interobserver and intra-observer agreements were substantial (0.786) and excellent (0.906), respectively. H. pylori infection was diagnosed in 29 patients (16.7%): 10/85 with PPIs and 19/89 without PPIs (11.8% vs. 21.3%; p = 0.09). All RAC + patients were free of H. pylori infection, with a sensitivity and negative predictive value of 100%, regardless of PPI intake. CONCLUSION: The endoscopic diagnosis of H. pylori by RAC is an easy-to-learn and highly reproducible technique, even with PPI intake. Our results warrant RAC as a real-time diagnostic method for H. pylori-negative infection in Western practice.


Assuntos
Infecções por Helicobacter , Helicobacter pylori , Mucosa Gástrica/patologia , Gastroscopia/métodos , Infecções por Helicobacter/diagnóstico , Humanos , Variações Dependentes do Observador , Estudos Prospectivos , Reprodutibilidade dos Testes , Vênulas/patologia
10.
Gastroenterol Rep (Oxf) ; 9(4): 299-305, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34567561

RESUMO

BACKGROUND: Biliary sphincter disorders after liver transplantation (LT) are poorly described. We aim to describe the presence and outcome of patients with papillary stenosis (PS) and functional biliary sphincter disorders (FBSDs) after LT according to the updated Rome IV criteria. METHODS: We reviewed all endoscopic retrograde cholangiopancreatographies (ERCPs) performed in LT recipients between January 2003 and December 2019. Information on clinical and endoscopic findings was obtained from electronic health records and endoscopy databases. Laboratory and clinical findings were collected at the time of ERCP and 1 month after ERCP. RESULTS: Among the 1,307 LT recipients, 336 underwent 849 ERCPs. Thirteen (1.0%) patients met the updated Rome IV criteria for PS [former sphincter of Oddi dysfunction (SOD) type I] and 14 patients (1.0%) met the Rome IV criteria for FBSD (former SOD type II). Biliary sphincterotomy was performed in 13 PS and 10 FBSD cases. One month after sphincterotomy, bilirubin, gamma-glutamyl transferase and alkaline phosphatase levels decreased in 85%, 61%, and 92% of those in the PS group (P = 0.019, 0.087, and 0.003, respectively) and in 50%, 70%, and 80% of those in the FBSD group (P = 0.721, 0.013, and 0.093, respectively). All the 14 patients initially suspected of having a FBSD turned out to have a different diagnosis during the follow-up. CONCLUSIONS: PS after LT is uncommon and occurs in only 1% of LT recipients. Our data do not support the presence of an FBSD after LT. Sphincterotomy is a safe and effective procedure in LT recipients with PS.

11.
Dig Dis ; 39(3): 179-189, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33002891

RESUMO

BACKGROUND: Guidelines give robust recommendations on which biopsies should be taken when there is endoscopic suggestion of gastric inflammation. Adherence to these guidelines often seems arbitrary. This study aimed to give an overview on current practice in tertiary referral centres across Europe. METHODS: Data were collected at 10 tertiary referral centres. Demographic data, the indication for each procedure, endoscopic findings, and the number and sampling site of biopsies were recorded. Findings were compared between centres, and factors influencing the decision to take biopsies were explored. RESULTS: Biopsies were taken in 56.6% of 9,425 procedures, with significant variation between centres (p < 0.001). Gastric biopsies were taken in 43.8% of all procedures. Sampling location varied with the procedure indication (p < 0.001) without consistent pattern across the centres. Fewer biopsies were taken in centres which routinely applied the updated Sydney classification for gastritis assessment (46.0%), compared to centres where this was done only upon request (75.3%, p < 0.001). This was the same for centres stratifying patients according to the OLGA system (51.8 vs. 73.0%, p < 0.001). More biopsies were taken in centres following the MAPS guidelines on stomach surveillance (68.1 vs. 37.1%, p < 0.001). Biopsy sampling was more likely in younger patients in 8 centres (p < 0.05), but this was not true for the whole cohort (p = 0.537). The percentage of procedures with biopsies correlated directly with additional costs charged in case of biopsies (r = 0.709, p = 0.022). CONCLUSION: Adherence to guideline recommendations for biopsy sampling at gastroscopy was inconsistent across the participating centres. Our data suggest that centre-specific policies are applied instead.


Assuntos
Endoscopia Gastrointestinal , Encaminhamento e Consulta , Centros de Atenção Terciária , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Adulto Jovem
12.
Eur J Cancer Prev ; 30(6): 431-436, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33369947

RESUMO

INTRODUCTION: Gastric premalignant conditions (GPC) surveillance has been proposed to improve the prognosis of gastric cancer (GC), but the early GC detection rate remaining low, and missing GC during an esophago-gastro-duodenoscopy is still a problem. We aimed to explore the gastroenterologists' attitudes on the detection and management of GPC. METHODS: A cross-sectional study was designed based on a survey among gastroenterologists from Asociación Española de Gastroenterología. RESULTS: The participation rate was 12% (146/1243). Eighty-one percent worked at secondary or tertiary-care hospitals with the capability to perform mucosectomy (80%), but with a lesser availability of endoscopic submucosal dissection (35%). Most respondents had high-definition endoscopes (88%), and virtual chromoendoscopy (86%), but during performing an upper endoscopy, 34% never or rarely use chromoendoscopy, and 73% apply a biopsy protocol often/very often when atrophy or intestinal metaplasia (IM) is suspected. Half of the respondents self-reported their ability to recognize atrophy or IM ≤7 (on a scale from 0 to 10), whereas ≤6 for dysplasia or early GC. Helicobacter pylori infection is eradicated and verified by ≥90%. Endoscopic surveillance of atrophy/IM is performed by 62%. An immediate endoscopy for dysplasia is not always performed. For low-grade dysplasia, 97.6% consider endoscopic management, but for high-grade dysplasia, 23% regard gastric surgery. CONCLUSION: There is a wide variability in the detection and management of GPC among Spanish gastroenterologists, and compliance with guidelines and biopsy protocols could be improved. Performance of high-quality gastroscopies including use of virtual chromoendoscopy, that might allow an improvement in the GPC detection, needs also to be generalized.


Assuntos
Gastroenterologistas , Infecções por Helicobacter , Helicobacter pylori , Lesões Pré-Cancerosas , Neoplasias Gástricas , Atrofia , Atitude , Estudos Transversais , Infecções por Helicobacter/patologia , Humanos , Metaplasia , Lesões Pré-Cancerosas/diagnóstico , Lesões Pré-Cancerosas/patologia , Espanha/epidemiologia , Neoplasias Gástricas/diagnóstico , Neoplasias Gástricas/epidemiologia , Neoplasias Gástricas/terapia , Inquéritos e Questionários
13.
BMC Med ; 18(1): 255, 2020 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-32943059

RESUMO

BACKGROUND: Colon capsule endoscopy (CCE) and CT colonography (CTC) are minimally invasive techniques for colorectal cancer (CRC) screening. Our objective is to compare CCE and CTC for the identification of patients with colorectal neoplasia among participants in a CRC screening programme with positive faecal immunochemical test (FIT). Primary outcome was to compare the performance of CCE and CTC in detecting patients with neoplastic lesions. METHODS: The VICOCA study is a prospective, single-centre, randomised trial conducted from March 2014 to May 2016; 662 individuals were invited and 349 were randomised to CCE or CTC before colonoscopy. Endoscopists were blinded to the results of CCE and CTC. RESULTS: Three hundred forty-nine individuals were included: 173 in the CCE group and 176 in the CTC group. Two hundred ninety individuals agreed to participate: 147 in the CCE group and 143 in the CTC group. In the intention-to-screen analysis, sensitivity, specificity and positive and negative predictive values for the identification of individuals with colorectal neoplasia were 98.1%, 76.6%, 93.7% and 92.0% in the CCE group and 64.9%, 95.7%, 96.8% and 57.7% in the CTC group. In terms of detecting significant neoplastic lesions, the sensitivity of CCE and CTC was 96.1% and 79.3%, respectively. Detection rate for advanced colorectal neoplasm was higher in the CCE group than in the CTC group (100% and 93.1%, respectively; RR = 1.07; p = 0.08). Both CCE and CTC identified all patients with cancer. CCE detected more patients with any lesion than CTC (98.6% and 81.0%, respectively; RR = 1.22; p = 0.002). CONCLUSION: Although both techniques seem to be similar in detecting patients with advanced colorectal neoplasms, CCE is more sensitive for the detection of any neoplastic lesion. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02081742 . Registered: September 16, 2013.


Assuntos
Endoscopia por Cápsula/métodos , Colonografia Tomográfica Computadorizada/métodos , Neoplasias Colorretais/diagnóstico por imagem , Neoplasias Colorretais/diagnóstico , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos , Neoplasias Colorretais/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
14.
Gastroenterol Hepatol ; 43(10): 589-597, 2020 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32674879

RESUMO

INTRODUCTION: In a previous study we demonstrated that a simple training programme improved quality indicators of Oesophagogastroduodenoscopy (OGD) achieving the recommended benchmarks. However, the long-term effect of this intervention is unknown. The aim of this study was to assess the quality of OGDs performed 3 years after of having completed a training programme. MATERIAL AND METHODS: A comparative study of 2 cohorts was designed as follows: Group A included OGDs performed in 2016 promptly after a training programme and Group B with OGDs performed from January to March 2019, this group was also divided into 2 subgroups: subgroup B1 of Endoscopists who had participated in the previous training programme and subgroup B2 of Endoscopists who had not. The intra-procedure quality indicators proposed by ASGE-ACG were used. RESULTS: A total of 1236 OGDs were analysed, 600 from Group A and 636 from Group B (439 subgroup B1 and 197 subgroup B2). The number of complete examinations was lower in Group B (566 [94.3%] vs. 551 [86.6%]; p<0.001). A significant decrease was observed in nearly all quality indicators and they did not reach the recommended benchmarks: retroflexion in the stomach (96% vs. 81%; p<0.001); Seattle biopsy protocol (86% vs. 50%; p=0.03), description of the upper GI bleeding lesion (100% vs. 62%; p<0.01), sufficient intestinal biopsy specimens (at least 4) in suspected coeliac disease (92.5% vs. 18%; p<0.001), photo documentation of the lesion (94% vs. 90%; p<0.05). Regarding the overall assessment of the procedure (including correct performance and adequate photo documentation), a significant decrease was also observed (90.5% vs. 62%; p<0.001). There were no differences between subgroups B1 and B2. CONCLUSIONS: The improvement observed in 2016 after a training programme did not prevail after 3 years. In order to keep the quality of OGDs above the recommended benchmarks, it is necessary to implement continuous training programmes.


Assuntos
Benchmarking , Duodenoscopia/normas , Esofagoscopia/normas , Gastroscopia/normas , Indicadores de Qualidade em Assistência à Saúde/normas , Biópsia/normas , Doença Celíaca/patologia , Estudos de Coortes , Duodenoscopia/educação , Duodenoscopia/estatística & dados numéricos , Esofagoscopia/educação , Esofagoscopia/estatística & dados numéricos , Hemorragia Gastrointestinal/diagnóstico por imagem , Gastroscopia/educação , Gastroscopia/estatística & dados numéricos , Humanos , Intestinos/patologia , Fotografação , Desenvolvimento de Programas , Padrões de Referência , Sociedades Médicas , Fatores de Tempo
16.
Gastroenterol Hepatol ; 43(4): 222-232, 2020 Apr.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-32143918

RESUMO

Computer-aided diagnosis (CAD) is a tool with great potential to help endoscopists in the tasks of detecting and histologically classifying colorectal polyps. In recent years, different technologies have been described and their potential utility has been increasingly evidenced, which has generated great expectations among scientific societies. However, most of these works are retrospective and use images of different quality and characteristics which are analysed off line. This review aims to familiarise gastroenterologists with computational methods and the particularities of endoscopic imaging, which have an impact on image processing analysis. Finally, the publicly available image databases, needed to compare and confirm the results obtained with different methods, are presented.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Diagnóstico por Computador/métodos , Pólipos do Colo/patologia , Bases de Dados Factuais , Humanos , Aprendizado de Máquina , Reprodutibilidade dos Testes
17.
Surg Endosc ; 34(4): 1887-1889, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32048018

RESUMO

BACKGROUND: Content-based image retrieval (CBIR) is an application of machine learning used to retrieve images by similarity on the basis of features. Our objective was to develop a CBIR system that could identify images containing the same polyp ('polyp fingerprint'). METHODS: A machine learning technique called Bag of Words was used to describe each endoscopic image containing a polyp in a unique way. The system was tested with 243 white light images belonging to 99 different polyps (for each polyp there were at least two images representing it in two different temporal moments). Images were acquired in routine colonoscopies at Hospital Clínic using high-definition Olympus endoscopes. The method provided for each image the closest match within the dataset. RESULTS: The system matched another image of the same polyp in 221/243 cases (91%). No differences were observed in the number of correct matches according to Paris classification (protruded: 90.7% vs. non-protruded: 91.3%) and size (< 10 mm: 91.6% vs. > 10 mm: 90%). CONCLUSIONS: A CBIR system can match accurately two images containing the same polyp, which could be a helpful aid for polyp image recognition.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonoscopia/métodos , Interpretação de Imagem Assistida por Computador/métodos , Armazenamento e Recuperação da Informação/métodos , Aprendizado de Máquina , Humanos
18.
Gastroenterol Hepatol ; 43(1): 46-56, 2020 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-31813615

RESUMO

Colorectal cancer is a major health problem. An improvement to its survival has been demonstrated by performing colonoscopy screenings and removing its precursor lesions: polyps. However, colonoscopy is not infallible and multiple strategies have been proposed aimed at improving the quality thereof. This report describes the endoscopic systems available to improve the detection and characterization of polyps, the different classifications for histological prediction and the current indications of advanced endoscopic diagnostic techniques.


Assuntos
Pólipos do Colo/diagnóstico por imagem , Colonoscópios/normas , Colonoscopia/métodos , Pólipos Intestinais/diagnóstico por imagem , Lesões Pré-Cancerosas/diagnóstico por imagem , Doenças Retais/diagnóstico por imagem , Colonoscopia/instrumentação , Neoplasias Colorretais/diagnóstico por imagem , Desenho de Equipamento , Humanos , Pólipos Intestinais/classificação
19.
Gastrointest Endosc ; 90(3): 461-466, 2019 09.
Artigo em Inglês | MEDLINE | ID: mdl-31108089

RESUMO

BACKGROUND AND AIMS: Helicobacter pylori is the major cause of gastritis and gastritis-associated diseases. Detection of a regular arrangement of collecting venules (RAC) in the lesser gastric curvature correlates with negative H pylori status with a sensitivity and negative predictive value (NPV) higher than 90% in Asian countries. The aim of the study was to evaluate the value of RAC as a diagnostic method of H pylori infection in a European population. METHODS: A prospective study with high-definition endoscopes without magnification was performed by 3 endoscopists. The presence of starfish-like minute points regularly distributed throughout the lesser curvature of the gastric body was considered RAC positive (RAC+). Gastric biopsies were performed during the procedure for H pylori diagnosis. RESULTS: One hundred forty patients were included from February 2017 to May 2018. The prevalence of H pylori infection was 31% and 47 of 140 patients (34%) were RAC+; 13 of 23 patients in whom H pylori was eradicated were RAC+. The mean age of RAC+ patients was lower (44.4 vs 52.4 years, P = .004) and they had less- significant endoscopic findings (9; 19.1% vs 38; 80.9%; P = .017). Gender, use of nonsteroidal anti-inflammatory drugs, antithrombotic or anticoagulants treatments, and a history of H pylori eradication did not show differences in the RAC pattern. The absence of RAC was associated with H pylori infection in 47.3% (44/93) of cases. In contrast, all RAC+ patients were free of H pylori infection, with sensitivity and NPV of 100% for the exclusion of H pylori infection. CONCLUSION: The presence of RAC+ in the lesser curvature evaluated with high-definition endoscopy can accurately identify patients without H pylori.


Assuntos
Gastroscopia , Infecções por Helicobacter/diagnóstico , Estômago/patologia , Vênulas/patologia , População Branca , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Infecções por Helicobacter/patologia , Helicobacter pylori , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Sensibilidade e Especificidade , Estômago/irrigação sanguínea , Adulto Jovem
20.
Endosc Int Open ; 7(4): E576-E582, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30994113

RESUMO

Background and study aims Endoscopic resection requires use of submucosal injection. This study was conducted to assess efficacy and impact on early healing of hyaluronic acid combined with chondroitin sulfate and poloxamer 407 (Ziverel) when used as a solution for submucosal injection. Materials and methods Prospective and comparative study of gastric endoscopic mucosal resection (EMR) with three groups of two Yorkshire pigs. Six submucosal cushions were created in each animal by injecting 2 mL of Ziverel (Group 1) or succinylated gelatin (SG) (Group 2), enabling 12 EMR in each group. Submucosal cushions were created with Ziverel in Group 3, without resection. Electrosurgery unit settings were the same in all cases. EMR defects and injection sites were marked with clips. The animals were sacrificed 7 days later. EMR specimen size and duration of procedure were recorded. EMR specimens and EMR scars and injection sites were evaluated by a blinded pathologist. Results We successfully performed 24 EMR (15 en-bloc and 9 piecemeal, without differences between groups 1 and 2). Mean EMR specimen dimensions were significantly larger in Group 1 (median 19 mm, range 6 - 40 vs 16.6 mm, range 5­25; P  = 0.019), without changing the electrocautery unit settings. Blinded histopathologist assessment of EMR specimens showed less fibrosis in the submucosa and a trend to fewer cautery artifacts with Ziverel and did not identify any significant differences in early healing of resection sites. Conclusion The combination of Ziverel enables EMR and does not negatively affect early healing.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA