Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-38697283

RESUMO

INTRODUCTION AND OBJECTIVES: The multiparametric implantable cardioverter-defibrillator HeartLogic index has proven to be a sensitive and timely predictor of impending heart failure (HF) decompensation. We evaluated the impact of a standardized follow-up protocol implemented by nursing staff and based on remote management of alerts. METHODS: The algorithm was activated in HF patients at 19 Spanish centers. Transmitted data were analyzed remotely, and patients were contacted by telephone if alerts were issued. Clinical actions were implemented remotely or through outpatient visits. The primary endpoint consisted of HF hospitalizations or death. Secondary endpoints were HF outpatient visits. We compared the 12-month periods before and after the adoption of the protocol. RESULTS: We analyzed 392 patients (aged 69±10 years, 76% male, 50% ischemic cardiomyopathy) with implantable cardioverter-defibrillators (20%) or cardiac resynchronization therapy defibrillators (80%). The primary endpoint occurred 151 times in 86 (22%) patients during the 12 months before the adoption of the protocol, and 69 times in 45 (11%) patients (P<.001) during the 12 months after its adoption. The mean number of hospitalizations per patient was 0.39±0.89 pre- and 0.18±0.57 postadoption (P<.001). There were 185 outpatient visits for HF in 96 (24%) patients before adoption and 64 in 48 (12%) patients after adoption (P<.001). The mean number of visits per patient was 0.47±1.11 pre- and 0.16±0.51 postadoption (P<.001). CONCLUSIONS: A standardized follow-up protocol based on remote management of HeartLogic alerts enabled effective remote management of HF patients. After its adoption, we observed a significant reduction in HF hospitalizations and outpatient visits.

2.
Cardiol J ; 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36908163

RESUMO

BACKGROUND: Ablation of atrial fibrillation (AF), both cryoablation ablation (CBA) and radiofrequency catheter ablation (RFCA), have demonstrated to be safe and effective. About 1 in 3 patients may face a redo due to recurrence and the best technique is unknown. The aim of this study is to assess the efficacy of CBA as a repeat procedure in patients with prior CBA or RFCA. METHODS: A nation-wide CBA registry (RECABA) was analyzed and patients were compared who had previously undergone CBA (Prior-CB) or RFCA (Prior-RF). The primary endpoint was AF recurrence at 12 months after a 3-month blanking period. A survival analysis was performed, univariate and multivariate Cox models were also built. RESULTS: Seventy-four patients were included. Thirty-three (44.6%) were in the Prior-CB group and 41 (55.4%) in the Prior-RF. There were more reconnected pulmonary veins in the Prior-RF than in Prior-CB group (40.4% vs.16.5%, p = 0.0001). The 12-month Kaplan-Meier estimate of freedom from AF recurrence after the blanking period was 61.0% (95% confidence interval [CI] 41.4-75.8%) in the Prior-CB, and 89.2% (95% CI 73.6-95.9%) in the Prior-RF group (p = 0.002). Multivariate Cox regression pointed Prior-CB as the sole independent predictor of AF recurrence, with an adjusted HR of 2.67 (95% CI 1.05-6.79). CONCLUSIONS: Repeat CBA shows higher rates of AF recurrences compared to CBA after a previous RFCA despite presenting less reconnected veins at the procedure. These data suggest that patients with AF recurrence after CBA may benefit from other ablation techniques after a recurrence. RECABA is registered at clinicaltrials.gov with the Unique Identifier NCT02785991.

3.
Card Fail Rev ; 8: e13, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35516795

RESUMO

Telemonitoring through multiple variables measured on cardiac devices has the potential to improve the follow-up of patients with heart failure. The HeartLogic algorithm (Boston Scientific), implemented in some implantable cardiac defibrillators and cardiac resynchronisation therapy, allows monitoring of the nocturnal heart rate, respiratory movements, thoracic impedance, physical activity and the intensity of heart tones, with the aim of predicting major clinical events. Although HeartLogic has demonstrated high sensitivity for the detection of heart failure decompensations, its effects on hospitalisation and mortality in randomised clinical trials has not yet been corroborated. This review details how the HeartLogic algorithm works, compiles available evidence from clinical studies, and discusses its application in daily clinical practice.

4.
Rev Esp Cardiol (Engl Ed) ; 75(9): 709-716, 2022 Sep.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34896031

RESUMO

INTRODUCTION AND OBJECTIVES: HeartLogic is a multiparametric algorithm incorporated into implantable cardioverter-defibrillators (ICD). The associated alerts predict impending heart failure (HF) decompensations. Our objective was to analyze the association between alerts and clinical events and to describe the implementation of a protocol for remote management in a multicenter registry. METHODS: We evaluated study phase 1 (the investigators were blinded to the alert state) and phases 2 and 3 (after HeartLogic activation, managed as per local practice and with a standardized protocol, respectively). RESULTS: We included 288 patients from 15 centers. In phase 1, the median observation period was 10 months and there were 73 alerts (0.72 alerts/patient-y), with 8 hospitalizations and 2 emergency room admissions for HF (0.10 events/patient-y). There were no HF hospitalizations outside the alert period. In the active phases, the median follow-up was 16 (95%CI, 15-22) months and there were 277 alerts (0.89 alerts/patient-y); 33 were associated with HF hospitalizations or HF death (n=6), 46 with minor decompensations, and 78 with other events. The unexplained alert rate was 0.39 alerts/patient-y. Outside the alert state, there was only 1 HF hospitalization and 1 minor HF decompensation. Most alerts (82% in phase 2 and 81% in phase 3; P=.861) were remotely managed. The median NT-proBNP value was higher within than outside the alert state (7378 vs 1210 pg/mL; P <.001). CONCLUSIONS: The HeartLogic index was frequently associated with HF-related events and other clinically relevant situations, with a low rate of unexplained events. A standardized protocol allowed alerts to be safely and remotely detected and appropriate action to be taken on them.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Algoritmos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Sistema de Registros
5.
Rev Esp Cardiol (Engl Ed) ; 74(12): 1072-1083, 2021 Dec.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-34756575

RESUMO

INTRODUCTION AND OBJECTIVES: This article reports the results of the 2020 Spanish Catheter Ablation Registry, a year marked by the SARS-CoV-2 pandemic. METHODS: Data were collected retrospectively through completion and return of a specific form by the participating centers. RESULTS: Data from 97 centers (67 public, 30 private) were analyzed. A total of 15 169 ablation procedures were reported with a mean of 155±117 and a median [interquartile range] of 115 [62-227]. Because of the SARS-CoV-2 pandemic, both procedures and participating centers markedly decreased (-3380 procedures,-18%) and there were 5 centers less than in 2019. The most common procedure continued to be atrial fibrillation ablation (4513; 30%), well ahead of the remaining substrates, followed by ablation of the cavotricuspid isthmus (3188; 21%), and intranodal re-entry tachycardia (2808; 18%). Ablation of these 3 substrates continued to form the bulk of the procedures. The total success rate was slightly lower than in previous years (88%) with a similar complication rate (n=309; 2%) and mortality (n=7; 0.04%). A total of 243 procedures were performed in pediatric patients (1.6%). CONCLUSIONS: The Spanish Catheter Ablation Registry systematically and continuously reflects the national trajectory, which, in 2020, was markedly affected by the SARS-CoV-2 pandemic. Although slightly lower than in previous years, the success rate remained high, with a low complication rate.


Assuntos
Fibrilação Atrial , COVID-19 , Cardiologia , Ablação por Cateter , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Criança , Humanos , Sistema de Registros , Estudos Retrospectivos , SARS-CoV-2
6.
Rev Esp Cardiol ; 74(12): 1073-1084, 2021 Dec.
Artigo em Espanhol | MEDLINE | ID: mdl-34413566

RESUMO

INTRODUCTION AND OBJECTIVES: This article reports the results of the 2020 Spanish Catheter Ablation Registry, a year marked by the SARS-CoV-2 pandemic. METHODS: Data were collected retrospectively through completion and return of a specific form by the participating centers. RESULTS: Data from 97 centers (67 public, 30 private) were analyzed. A total of 15 169 ablation procedures were reported with a mean of 155 ± 117 and a median [interquartile range] of 115 [62-227]. Because of the SARS-CoV-2 pandemic, both procedures and participating centers markedly decreased (-3380 procedures, -18%) and there were 5 centers less than in 2019. The most common procedure continued to be atrial fibrillation ablation (4513; 30%), well ahead of the remaining substrates, followed by ablation of the cavotricuspid isthmus (3188; 21%), and intranodal re-entry tachycardia (2808; 18%). Ablation of these 3 substrates continued to form the bulk of the procedures. The total success rate was slightly lower than in previous years (88%) with a similar complication rate (n = 309; 2%) and mortality (n = 7; 0.04%). A total of 243 procedures were performed in pediatric patients (1.6%). CONCLUSIONS: The Spanish Catheter Ablation Registry systematically and continuously reflects the national trajectory, which, in 2020, was markedly affected by the SARS-CoV-2 pandemic. Although slightly lower than in previous years, the success rate remained high, with a low complication rate.Full English text available from:www.revespcardiol.org/en.

9.
Rev Esp Cardiol ; 64(12): 1198-201, 2011 Dec.
Artigo em Espanhol | MEDLINE | ID: mdl-21835534

RESUMO

Premature ventricular contractions originating in the right ventricular outflow tract may respond poorly to pharmacological treatment, and ablation using conventional fluoroscopically-guided systems may be complicated by the difficulty in inducing arrhythmias. We describe the use of a non-contact mapping system to ablate difficult-to-induce premature ventricular contractions originating in the right ventricular outflow tract. Five premature ventricular contractions sites in the right ventricular outflow tract were ablated in a prospective series of 4 patients. Patients had a poor quality of life and had not responded to antiarrhythmic drugs. A mean of 3 radiofrequency pulses per site was applied and mean application time was 113±15s. We achieved a 100% acute success rate and there were no complications. Patients were asymptomatic without drug therapy after a mean of 30±16 months of follow-up. The noncontact mapping system is highly effective in eliminating difficult to induce, isolated premature ventricular contractions.


Assuntos
Ablação por Cateter/métodos , Técnicas Eletrofisiológicas Cardíacas/métodos , Imageamento Tridimensional/métodos , Complexos Ventriculares Prematuros/terapia , Agonistas Adrenérgicos beta/uso terapêutico , Adulto , Antiarrítmicos/uso terapêutico , Eletrocardiografia , Feminino , Fluoroscopia , Ventrículos do Coração , Humanos , Isoproterenol/uso terapêutico , Masculino , Microeletrodos , Pessoa de Meia-Idade , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA