Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 16(8): e0256469, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34432821

RESUMO

The current COVID-19 pandemic has led the world to an unprecedented global shortage of ventilators, and its sharing has been proposed as an alternative to meet the surge. This study outlines the performance of a preformed novel interface called 'ACRA', designed to split ventilator outflow into two breathing systems. The 'ACRA' interface was built using medical use approved components. It consists of four unidirectional valves, two adjustable flow-restrictor valves placed on the inspiratory limbs of each unit, and one adjustable PEEP valve placed on the expiratory limb of the unit that would require a greater PEEP. The interface was interposed between a ventilator and two lung units (phase I), two breathing simulators (phase II) and two live pigs with heterogeneous lung conditions (phase III). The interface and ventilator adjustments tested the ability to regulate individual pressures and the resulting tidal volumes. Data were analyzed using Friedman and Wilcoxon tests test (p < 0.05). Ventilator outflow splitting, independent pressure adjustments and individual tidal volume monitoring were feasible in all phases. In all experimental measurements, dual ventilation allowed for individual and tight adjustments of the pressure, and thus volume delivered to each paired lung unit without affecting the other unit's ventilation-all the modifications performed on the ventilator equally affected both paired lung units. Although only suggested during a dire crisis, this experiment supports dual ventilation as an alternative worth to be considered.


Assuntos
Pulmão/fisiopatologia , Síndrome do Desconforto Respiratório/fisiopatologia , Ventiladores Mecânicos , Animais , Pressão Sanguínea , Dióxido de Carbono/química , Simulação por Computador , Modelos Animais de Doenças , Frequência Cardíaca , Concentração de Íons de Hidrogênio , Suínos , Volume de Ventilação Pulmonar
2.
PLoS One ; 16(5): e0250672, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33945551

RESUMO

In this work a shared pressure-controlled ventilation device for two patients is considered. By the use of different valves incorporated to the circuit, the device enables the restriction of possible cross contamination and the individualization of tidal volumes, driving pressures, and positive end expiratory pressure PEEP. Possible interactions in the expiratory dynamics of different pairs of patients are evaluated in terms of the characteristic exhalatory times. These characteristic times can not be easily established using simple linear lumped element models. For this purpose, a 1D model using the Hydraulic and Mechanical libraries in Matlab Simulink was developed. In this sense, experiments accompany this study to validate the model and characterize the different valves of the circuit. Our results show that connecting two patients in parallel to a ventilator always resulted in delays of time during the exhalation. The size of this effect depends on different parameters associated with the patients, the circuit and the ventilator. The dynamics of the exhalation of both patients is determined by the ratios between patients exhalatory resistances, compliances, driving pressures and PEEPs. Adverse effects on exhalations became less noticeable when respiratory parameters of both patients were similar, flow resistances of valves added to the circuit were negligible, and when the ventilator exhalatory valve resistance was also negligible. The asymmetries of driving pressures, compliances or resistances exacerbated the possibility of auto-PEEP and the increase in relaxation times became greater in one patient than in the other. In contrast, exhalatory dynamics were less sensitive to the ratio of PEEP imposed to the patients.


Assuntos
Expiração , Respiração Artificial/instrumentação , Ventiladores Mecânicos , Humanos
3.
RSC Adv ; 10(9): 5361-5370, 2020 Jan 29.
Artigo em Inglês | MEDLINE | ID: mdl-35498312

RESUMO

This paper presents a methodology for cell detection and counting using a device that combines PDMS (polydimethylsiloxane) microfluidic multilayer channels with a single solid state micropore. Optimal conditions of solid-state micropore fabrication from crystalline silicon wafers are presented. Micropores of varying size can be obtained by directly etching using an etchant agent concentration of 50 wt% KOH, at varying temperatures (40, 60, 80 °C) and voltages (100, 500, 1000 mV). Scanning Electron Microscopy (SEM), and profilometry techniques have been used for the micropore characterization. In order to find optimal conditions for cell detection a COMSOL Multiphysics simulation was performed. Pressure drop, shear stress, fluid viscosities and flow rates parameters were evaluated. The potential viability of the device for cell detection and counting, avoiding cellular damage, is demonstrated.

4.
Lab Chip ; 14(23): 4506-12, 2014 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-25257193

RESUMO

We present a low-cost, portable microfluidic platform that uses laminated polymethylmethacrylate chips, peristaltic micropumps and LEGO® Mindstorms components for the generation of magnetoliposomes that does not require extrusion steps. Mixtures of lipids reconstituted in ethanol and an aqueous phase were injected independently in order to generate a combination of laminar flows in such a way that we could effectively achieve four hydrodynamic focused nanovesicle generation streams. Monodisperse magnetoliposomes with characteristics comparable to those obtained by traditional methods have been obtained. The magnetoliposomes are responsive to external magnetic field gradients, a result that suggests that the nanovesicles can be used in research and applications in nanomedicine.


Assuntos
Lipossomos/química , Imãs/química , Técnicas Analíticas Microfluídicas/métodos , Simulação por Computador , Desenho de Equipamento , Etanol , Hidrodinâmica , Lipídeos/química , Técnicas Analíticas Microfluídicas/instrumentação , Nanopartículas/química , Nefelometria e Turbidimetria
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA