Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
J Tissue Eng Regen Med ; 13(7): 1253-1264, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31050859

RESUMO

The protection from ischaemia-reperfusion-associated myocardial infarction worsening remains a big challenge. We produced a bioartificial 3D cardiac patch with cardioinductive properties on stem cells. Its multilayer structure was functionalised with clinically relevant doses of adenosine. We report here the first study on the potential of these cardiac patches in the controlled delivery of adenosine into the in vivo ischaemic-reperfused pig heart. A Fourier transform infrared chemical imaging approach allowed us to perform a characterisation, complementary to the histological and biochemical analyses on myocardial samples after in vivo patch implantation, increasing the number of investigations and results on the restricted number of pigs (n = 4) employed in this feasibility step. In vitro tests suggested that adenosine was completely released by a functionalised patch, a data that was confirmed in vivo after 24 hr from patch implantation. Moreover, the adenosine-loaded patch enabled a targeted delivery of the drug to the ischaemic-reperfused area of the heart, as highlighted by the activation of the pro-survival signalling reperfusion injury salvage kinases pathway. At 3 months, though limited to one animal, the used methods provided a picture of a tissue in dynamic conditions, associated to the biosynthesis of new collagen and to a non-fibrotic outcome of the healing process underway. The synergistic effect between the functionalised 3D cardiac patch and adenosine cardioprotection might represent a promising innovation in the treatment of reperfusion injury. As this is a feasibility study, the clinical implications of our findings will require further in vivo investigation on larger numbers of ischaemic-reperfused pig hearts.


Assuntos
Adenosina , Gelatina , Traumatismo por Reperfusão Miocárdica/tratamento farmacológico , Miocárdio , Copolímero de Ácido Poliláctico e Ácido Poliglicólico , Adenosina/química , Adenosina/farmacologia , Animais , Modelos Animais de Doenças , Implantes de Medicamento/química , Implantes de Medicamento/farmacologia , Feminino , Gelatina/química , Gelatina/farmacologia , Traumatismo por Reperfusão Miocárdica/metabolismo , Traumatismo por Reperfusão Miocárdica/patologia , Miocárdio/metabolismo , Miocárdio/patologia , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/química , Copolímero de Ácido Poliláctico e Ácido Poliglicólico/farmacologia , Suínos
2.
Biomed Pharmacother ; 90: 194-202, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28364596

RESUMO

The calcitonin-gene-related-peptide (CGRP) release is coupled to the signaling of Angeli's salt in determining vasodilator effects. However, it is unknown whether CGRP is involved in Angeli's salt cardioprotective effects and which are the mechanisms of protection. We aimed to determine whether CGRP is involved in myocardial protection induced by Angeli's salt. We also analyzed the intracellular signaling pathway activated by CGRP. Isolated rat hearts were pre-treated with Angeli's salt or Angeli's salt plus CGRP8-37, a specific CGRP-receptor antagonist, and subjected to ischemia (30-min) and reperfusion (120-min). Moreover, we studied CGRP-induced protection during oxidative stress (H2O2) and hypoxia/reoxygenation protocols in H9c2 cardiomyocytes. Cell vitality and mitochondrial membrane potential (ΔYm, MMP) were measured using MTT and JC-1 dyes. Angeli's salt reduced infarct size and ameliorated post-ischemic cardiac function via a CGRP-receptor-dependent mechanism. Pre-treatment with CGRP increased H9c2 survival upon challenging with either H2O2 (redox stress) or hypoxia/reoxygenation (H/R stress). Under these stress conditions, reduction in MMP and cell death were partly prevented by CGRP. These CGRP beneficial effects were blocked by CGRP8-37. During H/R stress, pre-treatment with either CGRP-receptor, protein kinase C (PKC) or mitochondrial KATP channel antagonists, and pre-treatment with an antioxidant (2-mercaptopropionylglycine) blocked the protection mediated by CGRP. In conclusion, CGRP is involved in the cardioprotective effects of Angeli's salt. In H9c2 cardiomyocytes, CGRP elicits PKC-dependent and mitochondrial-KATP-redox-dependent mechanisms. Hence, CGRP is an important factor in the redox-sensible cardioprotective effects of Angeli's salt.


Assuntos
Peptídeo Relacionado com Gene de Calcitonina/farmacologia , Coração/efeitos dos fármacos , Miócitos Cardíacos/efeitos dos fármacos , Oxirredução/efeitos dos fármacos , Substâncias Protetoras/farmacologia , Transdução de Sinais/efeitos dos fármacos , Animais , Antioxidantes/metabolismo , Peróxido de Hidrogênio/farmacologia , Masculino , Potencial da Membrana Mitocondrial/efeitos dos fármacos , Miocárdio/metabolismo , Miócitos Cardíacos/metabolismo , Canais de Potássio/metabolismo , Proteína Quinase C/metabolismo , Ratos , Ratos Wistar , Receptores de Peptídeo Relacionado com o Gene de Calcitonina/metabolismo
3.
Anal Bioanal Chem ; 405(1): 321-9, 2013 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23052887

RESUMO

The vast majority of stent thrombosis occurs in the acute and sub-acute phases and is more common in patients with acute coronary syndromes, due to the thrombotic milieu where stent struts are positioned. Stent thrombosis is likely due to incomplete tissue coverage of metallic stents as the contact between metallic stents and blood elements may lead to platelet adhesion and trigger vessel thrombosis. If a stent is covered after 7 days, the risk that it will be found uncovered at later stages is very low (<1%). In this article, we demonstrate that diamond-like carbon (DLC) coatings, deposited by physical vapour deposition, promote rapid endothelisation of coronary stent devices, with very low platelets activation, reducing thrombotic clots. We relate these behaviours to the surface and bulk material properties of the DLC films, subjected to a comprehensive chemico-physical characterisation using several techniques (X-ray photoelectron spectroscopy, atomic force microscopy, field-emission scanning electron microscope, transmission electron microscopy combined with electron energy loss spectroscopy, Raman and dispersive X-ray spectroscopy). In vivo studies, conducted on 24 pigs, have shown complete endothelisation after 7 days, with no fibrin mesh and with only rare monocytes scattered on the endothelial layer while 30 and 180 days tests have shown reduced inflammatory activation and a complete stabilisation of the vessel healing, with a minimal neointimal proliferation. The integral and permanent DLC film coating improves haemo- and bio-compatibility and leads to an excellent early vessel healing of the stent whilst the extremely thin strut thickness reduces the amount of late neointima and consequently the risk of late restenosis. These data should translate into a reduced acute and sub-acute stent thrombosis.


Assuntos
Físico-Química/métodos , Materiais Revestidos Biocompatíveis/química , Síndrome Coronariana Aguda/metabolismo , Adsorção , Albuminas/química , Animais , Materiais Biocompatíveis/química , Plaquetas/metabolismo , Carbono/química , Proliferação de Células , Elétrons , Células Endoteliais/metabolismo , Fibrinogênio/química , Inflamação , Microscopia de Força Atômica/métodos , Microscopia Eletrônica de Varredura/métodos , Microscopia Eletrônica de Transmissão/métodos , Análise Espectral Raman/métodos , Stents , Propriedades de Superfície , Suínos , Trombose , Fatores de Tempo
4.
EuroIntervention ; 7(9): 1087-94, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-22130128

RESUMO

AIMS: This new generation of DES has attempted to improve clinical safety by avoiding the presence of polymers. The present preclinical in vivo study was designed to investigate the safety profile of Cre8™ stent. This is a new coronary stent based on Amphilimus™, a sirolimus formulated with a polymer-free amphiphilic carrier released from reservoirs machined onto the abluminal stent surface. METHODS AND RESULTS: Cre8™ stents were compared with two controls: R3 (the same platform only loaded with an amphiphilic carrier) and the Cypher Select Plus® stent (Cordis, Johnson & Johnson, Warren, NJ, USA). All devices (48 stents) were implanted in porcine coronary arteries with subsequent histological and morphometric evaluations at seven, 30 and 90 days. Early endothelisation at seven days was almost complete in all stents. Vessel wall histology at 30 days demonstrated a mild inflammation score in all groups (an inflammation score lower than 1 was observed in 100% of Cre8 stent, 71.5% for R3 and 66.7% for Cypher; p=n.s.) while morphometry showed a significantly smaller neointimal area in Cre8™ (Cre8 0.93±0.43 mm2; R3 1.49±0.67 mm2; Cypher 1.81±0.94 mm2; Cre8 vs. Cypher p<0.05); this difference was maintained after 90 days (inflammation score lower than 1 in 100% of Cre8 stent, 100% for R3 and 66.7% for Cypher; p=n.s. Neointimal area was 1.27±0.56 mm2 for Cre8, 1.74±0.60 mm2 for R3 and 2.79±1.14 mm2 for Cypher; Cre8 and R3 vs. Cypher p<0.05 while neointimal thickness was 0.15±0.07 mm for Cre8, 0.21±0.12 mm for R3 and 0.31±0.15 mm for Cypher; Cre8 vs. Cypher p<0.05). CONCLUSIONS: The most significant experimental evidence appears to be the absence of chronic inflammatory response in Cre8™ stent. This is expressed by a reduced neointimal thickness and inflammatory score at all follow-ups. Such an outcome positively compares with the other DES where a trend to neointimal growth and increased cell infiltration was observed.


Assuntos
Vasos Coronários/patologia , Stents Farmacológicos/efeitos adversos , Neointima/epidemiologia , Neointima/etiologia , Polímeros , Sirolimo , Animais , Angiografia Coronária , Incidência , Inflamação/epidemiologia , Inflamação/etiologia , Modelos Animais , Suínos , Fatores de Tempo
5.
Calcif Tissue Int ; 88(5): 409-15, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-21331568

RESUMO

The fatigue life of a structure is also influenced by its size. Statistically, a bone from a large animal is expected to bear a higher risk of stress fracture if compared to the same bone from a small animal of the same species. This is not documented in the dog, where individuals can have a 40 times difference in body mass. We investigated the effect of body size on cortical bone microdamage accumulation, cortical microstructural organization (porosity, osteon area, and osteocyte lacunar density), and turnover in dogs with a wide body mass range. The aim was to understand and mathematically model how the bone tissue copes with the microdamage accumulation linked to body mass increase. Calcified transverse cortical sections of 18 canine radii of remarkably different size were examined by means of a standard bulk-staining technique and histomorphometric standard algorithms. Relationships between the investigated histomorphometric variables age, sex and mass were analyzed by general linear multivariate models and exponential equations. Type and location of microdamage and bone turnover were not influenced by body mass. Gender did not influence any parameter. Age influenced bone turnover and activation frequency. Microcrack density was influenced by bone mass. Bones had a similar microstructural organization within the same species regardless of the subject's dimension. Microdamage accumulation is inversely related to bone mass, whereas bone turnover is mass-invariant. We theorize a mass-related change in the bone fracture toughness targeted to reach an optimal unique dimensionless curve for fatigue life.


Assuntos
Índice de Massa Corporal , Osso e Ossos/fisiopatologia , Calcinose/fisiopatologia , Modelos Teóricos , Algoritmos , Animais , Cães , Feminino , Fraturas Ósseas/epidemiologia , Masculino , Modelos Animais , Fatores de Risco , Especificidade da Espécie
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA