Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Children (Basel) ; 10(5)2023 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-37238407

RESUMO

Treatment options for hypoplastic borderline left ventricle (LV) are critically dependent on the development of the LV itself and include different types of univentricular palliation or biventricular repair performed at birth. Since hybrid palliation allows deferring major surgery to 4-6 months, in borderline cases, the decision can be postponed until the LV has expressed its growth potential. We aimed to evaluate anatomic modifications of borderline LV after hybrid palliation. We retrospectively reviewed data from 45 consecutive patients with hypoplastic LV who underwent hybrid palliation at birth between 2011 and 2015. Sixteen patients (mean weight 3.15 Kg) exhibited borderline LV and were considered for potential LV growth. After 5 months, five patients underwent univentricular palliation (Group 1), eight biventricular repairs (Group 2) and three died before surgery. Echocardiograms of Groups 1 and 2 were reviewed, comparing LV structures at birth and after 5 months. Although, at birth, all LV measurements were far below the normal limits, after 5 months, LV mass in Group 2 was almost normal, while in Group 1, no growth was evident. However, aortic root diameter and long axis ratio were significantly higher in Group 2 already at birth. Hybrid palliation can be positively considered as a "bridge-to-decision" for borderline LV. Echocardiography plays a key role in monitoring the growth of borderline LV.

2.
Front Pediatr ; 10: 1073412, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36683796

RESUMO

A limiting factor in using vascular conduits in the pediatric/newborn population is their inability to grow. Many complex congenital heart diseases require palliative surgery, but using rigid and nonexpandable conduits does not allow the structures to grow and anticipates the need for redo surgery. In newborns, a way to increase the palliation time according to the patient's growth is desirable. In recent years, expandable shunts (exGraft™ PECA) have been developed. According to recent material studies, a shunt could increase diameter after endovascular balloon dilatation. In this case report, we describe the first case of endovascular Blalock-Thomas-Taussig shunt (mBT) shunt expansion in a Tetralogy of Fallot / atrial-ventricular Septal Defect complete (TOFAVSDc) patient with trisomy 21 who went to palliative treatment for tracheomalacia (noncardiac lesion association), severe pulmonary arteries hypoplasia, and low weight. This case introduces the "Smart Palliation concept" in the clinical scenario of selected growing patients where the lifetime of the Blalock-Thomas-Taussig (BT) shunt, anatomic substrates, and complexity of clinical status may require an additional palliation time. The limitation of endovascular conduit expansion is the fragility of the anastomosis site. The anastomosis site is a lesser strength structure of the conduit, and dilatation could develop procedure complications. For this reason, in this paper, we introduced our project design: a new technique (Clepsydra Shape) that consists, before surgical implantation, of pre-expansion of the proximal and distal anastomotic parts of the shunt to obtain an increase of 30% in size of both anastomotic sides, preventing stress- and stretch-related lesion of future balloon dilatation.

3.
Interact Cardiovasc Thorac Surg ; 27(5): 761-764, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29860487

RESUMO

Transcatheter creation or enlargement of an atrial septal defect has been used to promote adequate blood flow and mixing in some forms of congenital heart defects or as a relief valve in right or left atrial hypertension, resulting in better cardiac output and/or systemic saturation. We report a case of a 4-year-old male affected by complex congenital heart disease who was admitted for management of severe cyanosis following a staged pericardial fenestrated Fontan procedure. Transoesophageal echocardiogram showed a wide fenestration of 9 mm in size with a severely dilated pericardial Fontan system. To avoid a new surgical procedure and as part of a compassionate use programme, we decided to implant an atrial flow regulator device (4 mm in diameter) with percutaneous approach with the goal of reducing the right-to-left shunt and increasing the pulmonary flow. Preprocedural oxygen saturation was 75%, whereas after 2 months of follow-up, we observed a progressive increase of up to 95% with significant reduction in the pericardial Fontan system dimensions at echocardiography.


Assuntos
Cateterismo Cardíaco/métodos , Técnica de Fontan/métodos , Átrios do Coração/cirurgia , Comunicação Interatrial/cirurgia , Débito Cardíaco/fisiologia , Pré-Escolar , Ecocardiografia , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/diagnóstico , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA