Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
2.
Sci Rep ; 12(1): 1265, 2022 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-35075252

RESUMO

To identify predictors of neonatal ECMO circuit health, a retrospective analysis of circuit functional pressure and flow parameters as well as infant clotting values were collected 48 h prior to and 24 h post circuit change. Circuit impairment was defined as need for partial or total circuit change. Statistical analysis used multivariate statistics and non-parametric Mann-Whitney U-test with possible non-normality of measurements. A total of 9764 ECMO circuit and clotting values in 21 circuits were analyzed. Circuit delta-P mean, and maximum values increased from 8.62 to 48.59 mmHg (p < 0.011) and 16.00 to 53.00 mmHg (p < 0.0128) respectively prior to need for circuit change. Maximum and mean Pump Flow Revolutions per minute (RPM) increased by 75% (p < 0.0043) and 81% (p < 0.0057), respectively. Mean plasma free hemoglobin (pfHb) increased from 26.45 to 76.00 mg/dl, (p < 0.0209). Sweep, venous pressure, and clotting parameters were unaffected. ECMO circuit delta-P, RPM, and pfHb were early predictors of circuit impairment.


Assuntos
Oxigenação por Membrana Extracorpórea/instrumentação , Testes de Coagulação Sanguínea , Oxigenação por Membrana Extracorpórea/estatística & dados numéricos , Feminino , Humanos , Recém-Nascido , Masculino , Contagem de Plaquetas , Estudos Retrospectivos
3.
Crit Care Med ; 42(12): 2591-9, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25072753

RESUMO

OBJECTIVES: Fluid overload is associated with poor PICU outcomes in different populations. Little is known about fluid overload in children undergoing cardiac surgery. We described fluid overload after cardiac surgery, identified risk factors of worse fluid overload and also determined if fluid overload predicts longer length of PICU stay, prolonged mechanical ventilation (length of ventilation) and worse lung function as estimated by the oxygenation index. DESIGN: Retrospective cohort study. SETTING: Montreal Children's Hospital PICU, Montreal, Canada. PATIENTS: Patients 18 years or younger undergoing cardiac surgery (2005-2007). INTERVENTIONS: None. MEASUREMENTS AND MAIN RESULTS: Cumulative fluid overload % was calculated as [(total fluid in - out in L)/admission weight (kg) × 100] and expressed as PICU peak cumulative fluid overload % throughout admission and PICU day 2 cumulative fluid overload %. Primary outcomes were length of stay and length of ventilation. The secondary outcome was oxygenation index. Fluid overload risk factors were evaluated using stepwise linear regression. Fluid overload-outcome relations were evaluated using stepwise Cox regression (length of stay, length of ventilation) and generalized estimating equations (daily PICU cumulative fluid overload % and oxygenation index repeated measures). There were 193 eligible surgeries. Peak cumulative fluid overload % was 7.4% ± 11.2%. Fluid overload peaked on PICU day 2. Lack of past cardiac surgery (p = 0.04), cyanotic heart disease (p = 0.03), and early postoperative fluids (p = 0.0001) was independently associated with higher day 2 fluid overload %. Day 2 fluid overload % predicted longer length of stay (adjusted hazard ratio, 0.95; 95% CI, 0.92-0.99; p = 0.009) and length of ventilation (adjusted hazard ratio, 0.97; 95% CI, 0.94-0.99; p = 0.03). In patients without cyanotic heart disease, worse daily fluid overload % predicted worse daily oxygenation index. CONCLUSION: Fluid overload occurs early after cardiac surgery and is associated with prolonged PICU length of stay and ventilation. Future fluid overload avoidance trials may confirm or refute a true fluid overload-outcome causative association.


Assuntos
Líquidos Corporais/metabolismo , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Unidades de Terapia Intensiva Pediátrica/estatística & dados numéricos , Complicações Pós-Operatórias/mortalidade , Injúria Renal Aguda/epidemiologia , Procedimentos Cirúrgicos Cardíacos/mortalidade , Criança , Pré-Escolar , Feminino , Humanos , Incidência , Lactente , Tempo de Internação/estatística & dados numéricos , Masculino , Complicações Pós-Operatórias/epidemiologia , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos , Fatores de Risco , Fatores Sexuais
4.
World J Pediatr Congenit Heart Surg ; 1(1): 34-43, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23804721

RESUMO

Patients undergoing congenital heart surgery are at risk of morbidity and mortality. The reasons underlying this risk are complex. To identify opportunities to reduce adverse sequelae, the cardiovascular perfusion community was invited to amend existing perfusion-related fields as well as add new ones to the current version of the Society of Thoracic Surgeons Congenital Heart Surgery Database (STS-CHSD). The International Consortium for Evidence-Based Perfusion (ICEBP) was invited by the STS-CHSD Task Force to identify and resolve ambiguities related to definitions among the 3 current perfusion-related fields as well as to propose new variables (and definitions) for inclusion in the 2010 update of the STS-CHSD. The ICEBP used teleconferences, wiki-based communication software, and e-mail to discuss current definitions and create new fields with definitions. The ICEBP created modified definitions to existing fields related to cardiovascular perfusion and also developed and defined new fields that focus on (1) techniques of circulatory arrest and cerebral perfusion, (2) strategies of myocardial protection, and (3) techniques to minimize hemodilution and allogeneic blood transfusions. Three fields in the STS-CHSD related to perfusion were redefined, and 23 new variables and definitions were selected for inclusion. Identifying and defining fields specific to the practice of perfusion are requisite for assessing and subsequently improving the care provided to patients undergoing congenital heart surgery. The article describes the methods and justification for adjudicating extant and new perfusion-related fields added to the 2010 update of the STS-CHSD.

5.
Cardiol Young ; 18 Suppl 2: 206-14, 2008 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19063793

RESUMO

The International Consortium for Evidence-Based Perfusion (www.bestpracticeperfusion.org) is a collaborative partnership of societies of perfusionists, professional medical societies, and interested clinicians, whose aim is to promote the continuous improvement of the delivery of care and outcomes for patients undergoing extracorporeal circulation. Despite the many advances made throughout the history of cardiopulmonary bypass, significant variation in practice and potential for complication remains. To help address this issue, the International Consortium for Evidence-Based Perfusion has joined the Multi-Societal Database Committee for Pediatric and Congenital Heart Disease to develop a list of complications in congenital cardiac surgery related to extracorporeal circulation conducted via cardiopulmonary bypass, extracorporeal membrane oxygenation, or mechanical circulatory support devices, which include ventricular assist devices and intra-aortic balloon pumps. Understanding and defining the complications that may occur related to extracorporeal circulation in congenital patients is requisite for assessing and subsequently improving the care provided to the patients we serve. The aim of this manuscript is to identify and define the myriad of complications directly related to the extracorporeal circulation of congenital patients.


Assuntos
Procedimentos Cirúrgicos Cardíacos/estatística & dados numéricos , Bases de Dados Factuais , Circulação Extracorpórea/efeitos adversos , Cardiopatias Congênitas/cirurgia , Complicações Intraoperatórias/epidemiologia , Perfusão/efeitos adversos , Criança , Consenso , Humanos , Morbidade/tendências , Sistema de Registros/estatística & dados numéricos , Sociedades Médicas , Estados Unidos/epidemiologia
6.
Ann Thorac Surg ; 83(3): 1179-81, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17307489

RESUMO

We report the implantation of a Berlin Heart ventricular assist device (VAD) in a 4-year-old boy with hypoplastic left heart syndrome previously palliated with Norwood and Glenn operations, who presented with progressive ventricular failure and hypoxemia. Insertion of a 30-mL pneumatic pediatric pump with cannulation of the systemic right ventricle and aorta had a salutary effect on cardiac output, improving oxygen saturations. While awaiting heart transplantation, multiple thromboembolic complications developed and he died, despite therapeutic heparinization and aspirin therapy. Important lessons learned about VAD support in Glenn physiology, anticoagulation, and complications of the Berlin Heart are discussed.


Assuntos
Coração Auxiliar , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Aorta , Baixo Débito Cardíaco/etiologia , Cateterismo , Pré-Escolar , Evolução Fatal , Transplante de Coração , Ventrículos do Coração , Humanos , Síndrome do Coração Esquerdo Hipoplásico/complicações , Hipóxia/etiologia , Masculino , Listas de Espera
8.
J Extra Corpor Technol ; 36(2): 158-61, 2004 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15334757

RESUMO

There is a very limited published material about experience with long-term pediatric mechanical circulatory support as a bridge to heart transplant. We report on a 2-year-old, 12 kg boy admitted with 2-week history of low-grade fever, ear pain, pulmonary edema, and congestive heart failure. Trans-thoracic echocardiography confirmed severe myocardial dysfunction with a left ventricular ejection fraction of 0.20 and percentage shortening of 13. After 2 days of ventilatory and inotropic support, the patient continued to deteriorate and subsequently required femoro-femoral extracorporeal life support (ECLS). This was later complicated by a progressive coagulopathy and massive bleeding. On day 17, a pulsatile pediatric paracorporeal biventricular assist device (VAD) (Berlin Heart) was implanted. The patient's condition improved significantly with all coagulopathies corrected, and the patient was extubated 21 days later. After 109 days of bi-VAD support, the patient was successfully transplanted and discharged home 45 days post transplant. Our early experience with initial ECLS bridge to VAD and subsequently to transplant was encouraging. It allowed for additional time to select the ideal organ donor and optimize the recipient's comorbid condition and multiorgan failure. VAD provides an additional armamentarium of circulatory support in pediatric patients with severe heart failure.


Assuntos
Circulação Extracorpórea/instrumentação , Insuficiência Cardíaca/cirurgia , Transplante de Coração , Coração Auxiliar , Cuidados Pré-Operatórios , Pré-Escolar , Progressão da Doença , Humanos , Sistemas de Manutenção da Vida , Masculino , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA