Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Eur J Obstet Gynecol Reprod Biol ; 299: 136-142, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38865740

RESUMO

BACKGROUND: Prior studies have shown that maternal deaths due to sepsis occur due to delays in recognition, treatment, and escalation of care through medical chart reviews. This study was conducted to obtain the patient perspective for near-miss and maternal mortality cases due to sepsis. OBJECTIVE: To identify quality improvement opportunities for improving maternal sepsis through patient and support person experiences. STUDY DESIGN: Twenty semi-structured interviews and three follow-up focus groups with patients who experienced critical illness from maternal sepsis in the United States and their support persons (when available) were conducted from May 23, 2022, through October 14, 2022. In this qualitative study, data were analyzed using inductive thematic analysis. RESULTS: In this qualitative study of patients with maternal sepsis and their support persons, four main quality improvement themes were identified. The themes were the following: (1) participants reported a lack of awareness of pregnancy-related warning signs and symptoms of when to seek care, (2) many of the presenting symptoms participants experienced were not typical of expected warning signs of maternal sepsis, such as severe pain, overwhelming tiredness, and lack of fever (3) participant concerns were met with dismissal leading to delays in diagnosis, (4) participants experienced long-term sequelae but had difficulty receiving screening and referrals for treatment. CONCLUSIONS: The findings of this study suggest that standardized patient education about the warning signs of maternal sepsis and provider education about the presentation of maternal sepsis, improved listening to patients, and follow-up for sequalae of sepsis are needed.


Assuntos
Pesquisa Qualitativa , Sepse , Sobreviventes , Humanos , Feminino , Gravidez , Adulto , Sepse/mortalidade , Sepse/terapia , Sobreviventes/psicologia , Mortalidade Materna , Complicações Infecciosas na Gravidez/mortalidade , Complicações Infecciosas na Gravidez/terapia , Complicações Infecciosas na Gravidez/psicologia , Near Miss/estatística & dados numéricos , Melhoria de Qualidade , Estados Unidos/epidemiologia , Grupos Focais
2.
Obstet Gynecol ; 143(3): 336-345, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38086052

RESUMO

OBJECTIVE: To evaluate the performance characteristics of existing screening tools for the prediction of sepsis during antepartum and postpartum readmissions. METHODS: This was a case-control study using electronic health record data obtained between 2016 and 2021 from 67 hospitals for antepartum sepsis admissions and 71 hospitals for postpartum readmissions up to 42 days. Patients in the sepsis case group were matched in a 1:4 ratio to a comparison cohort of patients without sepsis admitted antepartum or postpartum. The following screening criteria were evaluated: the CMQCC (California Maternal Quality Care Collaborative) initial sepsis screen, the non-pregnancy-adjusted SIRS (Systemic Inflammatory Response Syndrome), the MEWC (Maternal Early Warning Criteria), UKOSS (United Kingdom Obstetric Surveillance System) obstetric SIRS, and the MEWT (Maternal Early Warning Trigger Tool). Time periods were divided into early pregnancy (less than 20 weeks of gestation), more than 20 weeks of gestation, early postpartum (less than 3 days postpartum), and late postpartum through 42 days. False-positive screening rates, C-statistics, sensitivity, and specificity were reported for each overall screening tool and each individual criterion. RESULTS: We identified 525 patients with sepsis during an antepartum hospitalization and 728 patients with sepsis during a postpartum readmission. For early pregnancy and more than 3 days postpartum, non-pregnancy-adjusted SIRS had the highest C-statistics (0.78 and 0.83, respectively). For more than 20 weeks of gestation and less than 3 days postpartum, the pregnancy-adjusted sepsis screening tools (CMQCC and UKOSS) had the highest C-statistics (0.87-0.94). The MEWC maintained the highest sensitivity rates during all time periods (81.9-94.4%) but also had the highest false-positive rates (30.4-63.9%). The pregnancy-adjusted sepsis screening tools (CMQCC, UKOSS) had the lowest false-positive rates in all time periods (3.9-10.1%). All tools had the lowest C-statistics in the periods of less than 20 weeks of gestation and more than 3 days postpartum. CONCLUSION: For admissions early in pregnancy and more than 3 days postpartum, non-pregnancy-adjusted sepsis screening tools performed better than pregnancy-adjusted tools. From 20 weeks of gestation through up to 3 days postpartum, using a pregnancy-adjusted sepsis screening tool increased sensitivity and minimized false-positive rates. The overall false-positive rate remained high.


Assuntos
Infecção Puerperal , Sepse , Gravidez , Feminino , Humanos , Estudos de Casos e Controles , Período Pós-Parto , Hospitalização , Sepse/diagnóstico , Sepse/epidemiologia , Síndrome de Resposta Inflamatória Sistêmica , Estudos Retrospectivos
3.
Obstet Gynecol ; 143(3): 326-335, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38086055

RESUMO

OBJECTIVE: To evaluate the screening performance characteristics of existing tools for the diagnosis of sepsis during delivery admissions. METHODS: This was a case-control study using electronic health record data, including vital signs and laboratory results, for all delivery admissions of patients with sepsis from 59 nationally distributed hospitals. Patients with sepsis were matched by gestational age at delivery in a 1:4 ratio with patients without sepsis to create a comparison group. Patients with chorioamnionitis and sepsis were compared with a complete cohort of patients with chorioamnionitis without sepsis. Multiple screening criteria for sepsis were evaluated: the CMQCC (California Maternal Quality Care Collaborative), SIRS (Systemic Inflammatory Response Syndrome), the MEWC (the Maternal Early Warning Criteria), UKOSS (United Kingdom Obstetric Surveillance System), and the MEWT (Maternal Early Warning Trigger Tool). Sensitivity, false-positive rates, and C-statistics were reported for each screening tool. Analyses were stratified into cohort 1, which excluded patients with chorioamnionitis-endometritis, and cohort 2, which included those patients. RESULTS: Delivery admissions at 59 hospitals were extracted for patients with sepsis. Cohort 1 comprised 647 patients with sepsis, including 228 with end-organ injury, matched with a control group of 2,588 patients without sepsis. Cohort 2 comprised 14,591 patients with chorioamnionitis-endometritis, of whom 1,049 had sepsis and 238 had end-organ injury. In cohort 1, the CMQCC and the UKOSS pregnancy-adjusted criteria had the lowest false-positive rates (6.9% and 9.6%, respectively) and the highest C-statistics (0.92 and 0.91, respectively). Although other screening criteria, such as SIRS and the MEWC, had similar sensitivities, it was at the cost of much higher false-positive rates (21.3% and 38.3%, respectively). In cohort 2, including all patients with chorioamnionitis-endometritis, the highest C-statistics were again for the CMQCC (0.67) and UKOSS (0.64). All screening tools had high false-positive rates, but the false-positive rates for the CMQCC and UKOSS were substantially lower than those for SIRS and the MEWC. CONCLUSION: During delivery admissions, the CMQCC and UKOSS pregnancy-adjusted screening criteria have the lowest false-positive results while maintaining greater than 90% sensitivity rates. Performance of all screening tools was degraded in the setting of chorioamnionitis-endometritis.


Assuntos
Corioamnionite , Endometrite , Sepse , Gravidez , Feminino , Humanos , Corioamnionite/diagnóstico , Corioamnionite/epidemiologia , Estudos de Casos e Controles , Estudos Retrospectivos , Sepse/diagnóstico , Síndrome de Resposta Inflamatória Sistêmica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA