Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Stroke ; 52(1): 203-212, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33317416

RESUMO

BACKGROUND AND PURPOSE: There is interest in what happens over time to the thrombus after intravenous alteplase. We study the effect of alteplase on thrombus structure and its impact on clinical outcome in patients with acute stroke. METHODS: Intravenous alteplase treated stroke patients with intracranial internal carotid artery or middle cerebral artery occlusion identified on baseline computed tomography angiography and with follow-up vascular imaging (computed tomography angiography or first run of angiography before endovascular therapy) were enrolled from INTERRSeCT study (Identifying New Approaches to Optimize Thrombus Characterization for Predicting Early Recanalization and Reperfusion With IV Alteplase and Other Treatments Using Serial CT Angiography). Thrombus movement after intravenous alteplase was classified into complete recanalization, thrombus migration, thrombus fragmentation, and no change. Thrombus migration was diagnosed when occlusion site moved distally and graded according to degrees of thrombus movement (grade 0-3). Thrombus fragmentation was diagnosed when a new distal occlusion in addition to the primary occlusion was identified on follow-up imaging. The association between thrombus movement and clinical outcome was also evaluated. RESULTS: Among 427 patients in this study, thrombus movement was seen in 54% with a median time of 123 minutes from alteplase administration to follow-up imaging, and sub-classified as marked (thrombus migration grade 2-3 + complete recanalization; 27%) and mild to moderate thrombus movement (thrombus fragmentation + thrombus migration grade 0-1; 27%). In patients with proximal M1/internal carotid artery occlusion, marked thrombus movement was associated with a higher rate of good outcome (90-day modified Rankin Scale, 0-2) compared with mild to moderate movement (52% versus 27%; adjusted odds ratio, 5.64 [95% CI, 1.72-20.10]). No difference was seen in outcomes between mild to moderate thrombus movement and no change. In M1 distal/M2 occlusion, marked thrombus movement was associated with improved 90-day good outcome compared with no change (70% versus 56%; adjusted odds ratio, 2.54 [95% CI, 1.21-5.51]). CONCLUSIONS: Early thrombus movement is common after intravenous alteplase. Marked thrombus migration leads to good clinical outcomes. Thrombus dynamics over time should be further evaluated in clinical trials of acute reperfusion therapy.


Assuntos
Fibrinolíticos/uso terapêutico , Trombose Intracraniana/diagnóstico por imagem , Trombose Intracraniana/tratamento farmacológico , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Administração Intravenosa , Idoso , Idoso de 80 Anos ou mais , Artéria Carótida Interna , Estenose das Carótidas/diagnóstico por imagem , Estenose das Carótidas/tratamento farmacológico , Angiografia por Tomografia Computadorizada , Feminino , Fibrinolíticos/administração & dosagem , Humanos , Infarto da Artéria Cerebral Média/diagnóstico por imagem , Infarto da Artéria Cerebral Média/tratamento farmacológico , Masculino , Pessoa de Meia-Idade , Reperfusão , Terapia Trombolítica , Ativador de Plasminogênio Tecidual/administração & dosagem , Tomografia Computadorizada por Raios X , Resultado do Tratamento
2.
Rev Neurol ; 57(6): 251-7, 2013 Sep 16.
Artigo em Espanhol | MEDLINE | ID: mdl-24008935

RESUMO

INTRODUCTION: Implantable loop recorders (ILR) may allow detection of occult paroxysmal atrial fibrillation (PAF) in patients with cryptogenic ischemic stroke. However, optimal selection algorithm and ideal duration of monitoring remain unclear. AIM. To determine the incidence and time-profile of PAF in patients with cryptogenic ischemic stroke studied with Reveal XT ILR, who were selected based on a high suspicion of cerebral embolism. SELECTION CRITERIA: absence of stroke etiology after complete study including vascular imaging, transesophageal echocardiography and at least 24 hours of cardiac rhythm monitoring, and confirmation of acute embolic occlusion of intracranial artery by transcranial duplex or characteristics of acute ischemic lesion on neuroimaging suggesting embolic mechanism of ischemia. After implanting Reveal XT ILR, patients were trained to perform transmissions monthly or when symptoms occurred. We reviewed the information online each month and patients underwent clinical visits at 3rd and 6th month and then every six months. RESULTS: We included 101 patients with cryptogenic ischemic stroke and at least one month of follow-up after ILR implant. Mean age was 67 years, 54 women (53.5%). Mean follow-up after implantation was 281 ± 212 days. Occult PAF was detected in 34 patients (33.7%). Frequency of false positives: 22.8%. Median time from implant to arrhythmia detection was 102 days (range: 26-240 days). 24 (70%) patients with PAF had several arrhythmic episodes detected with ILR. The majority of events (75%) were detected during the first six months of monitoring. CONCLUSIONS: In our patients with probably embolic cryptogenic ischemic stroke, PAF was detected by Reveal XT ILR in 33.7%. One in four events occurred after the first six months of monitoring.


TITLE: Alto rendimiento del holter implantable en la deteccion de fibrilacion auricular paroxistica oculta en pacientes con ictus criptogenico y sospecha de mecanismo embolico.Introduccion. El holter implantable permite detectar fibrilacion auricular paroxistica (FAP) oculta en pacientes con ictus criptogenico, pero se desconoce que algoritmo de seleccion tiene un mayor rendimiento y la duracion optima de monitorizacion. Objetivo. Conocer la frecuencia y el tiempo hasta detectar la FAP mediante un holter implantable Reveal XT ® en pacientes con ictus criptogenico seleccionados por sospecha elevada de embolismo cerebral. Pacientes y metodos. Criterios de seleccion: ausencia de etiologia del ictus tras el estudio completo incluyendo un ecocardiograma transesofagico, monitorizacion ECG y holter de 24 horas, asi como confirmacion de oclusion aguda embolica de la arteria intracraneal por duplex transcraneal o bien alta sospecha de embolismo por caracteristicas de neuroimagen. Tras implantar el holter Reveal XT se formo a los pacientes para que emprendieran transmisiones todos los meses o ante sintomas. Se reviso la informacion online mensualmente y se realizaron visitas clinicas en las unidades de Neurologia y Cardiologia. Resultados. Se incluyeron 101 pacientes con ictus criptogenico y al menos un mes de seguimiento: edad media de 67 años, 54 mujeres (53,5%). Tiempo medio de seguimiento: 281 ± 212 dias. Se detecto FAP oculta en 34 pacientes (33,7%) y falsos positivos en 23 (22,8%). Mediana desde el implante hasta la deteccion de la arritmia: 102 dias (rango: 26-240 dias). En un 70% de los pacientes se registraron multiples episodios de FAP. El 75% de los eventos se detectaron durante los primeros seis meses de monitorizacion. Conclusiones. El algoritmo de seleccion de pacientes con ictus criptogenico segun sospecha de embolismo cerebral se asocio a una elevada frecuencia (33,7%) de FAP oculta con holter implantable. Uno de cada cuatro eventos sucedio tras los primeros seis meses de monitorizacion.


Assuntos
Fibrilação Atrial/diagnóstico , Eletrocardiografia Ambulatorial/instrumentação , Embolia Intracraniana/etiologia , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Infarto Cerebral/diagnóstico por imagem , Infarto Cerebral/etiologia , Reações Falso-Positivas , Feminino , Seguimentos , Humanos , Embolia Intracraniana/diagnóstico por imagem , Ataque Isquêmico Transitório/diagnóstico por imagem , Ataque Isquêmico Transitório/etiologia , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Seleção de Pacientes , Próteses e Implantes , Reprodutibilidade dos Testes , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA