Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Pediatr Res ; 87(Suppl 1): 50-58, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-32218536

RESUMO

INTRODUCTION: Very and extremely preterm infants frequently have brain injury-related long-term neurodevelopmental problems. Altered perfusion, for example, seen in the context of a hemodynamically significant patent ductus arteriosus (PDA), has been linked to injury of the immature brain. However, a direct relation with outcome has not been reviewed systematically. METHODS: A systematic review was conducted to provide an overview of the value of different cerebral arterial blood flow parameters assessed by Doppler ultrasound, in relation to brain injury, to predict long-term neurodevelopmental outcome in preterm infants. RESULTS: In total, 23 studies were included. Because of heterogeneity of studies, a meta-analysis of results was not possible. All included studies on resistance index (RI) showed significantly higher values in subjects with a hemodynamically significant PDA. However, absolute differences in RI values were small. Studies using Doppler parameters to predict brain injury and long-term neurodevelopmental outcome were inconsistent. DISCUSSION: There is no clear evidence to support the routine determination of RI or other Doppler parameters in the cerebral arteries to predict brain injury and long-term neurodevelopmental outcome in the preterm infant. However, there is evidence that elevated RI can point to the presence of a hemodynamically significant PDA.


Assuntos
Lesões Encefálicas/diagnóstico por imagem , Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Circulação Cerebrovascular , Doenças do Prematuro/diagnóstico por imagem , Neonatologia/métodos , Ultrassonografia Doppler/métodos , Permeabilidade do Canal Arterial/diagnóstico por imagem , Hemodinâmica , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Perfusão , Valor Preditivo dos Testes
2.
Pediatr Radiol ; 46(9): 1291-300, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27259991

RESUMO

BACKGROUND: Little is known about cerebral artery resistive index values in infants born extremely preterm. OBJECTIVE: To report resistive index values in various cerebral arteries in a prospective cohort of preterm infants born at <29 weeks' gestation, and to compare resistive index in these arteries and assess the relationship between resistive index and hemodynamically significant patent ductus arteriosus. MATERIALS AND METHODS: Using Doppler imaging, we obtained resistive index values of internal carotid arteries, basilar artery, anterior cerebral artery, and pial and striatal arteries in the first 3 days of age and weekly thereafter until discharge or death. We analyzed paired observations using the Wilcoxon signed-rank test, between-group comparisons with the Mann-Whitney test. RESULTS: We performed 771 examinations in 235 infants. Resistive indices differed among arteries: vessels with larger diameters showed significantly higher resistive indices. Resistive index in infants without patent ductus arteriosus was lower than that in infants with hemodynamically significant patent ductus arteriosus (median in anterior cerebral artery: 0.75 and 0.82, respectively; P<0.001), though this was not statistically significant in all arteries. There was no difference in pre- and post-ligation resistive indices in infants who underwent patent ductus arteriosus ligation. CONCLUSION: For accurate follow-up and comparison of cerebral artery resistive index, the same artery should be examined on each occasion.


Assuntos
Artérias Cerebrais/diagnóstico por imagem , Artérias Cerebrais/fisiopatologia , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Ultrassonografia Doppler Dupla , Resistência Vascular/fisiologia , Feminino , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Masculino , Estudos Prospectivos
3.
J Vis Exp ; (96): e52238, 2015 Feb 02.
Artigo em Inglês | MEDLINE | ID: mdl-25742241

RESUMO

Cranial ultrasound (CUS) is a reputable tool for brain imaging in critically ill neonates. It is safe, relatively cheap and easy to use, even when a patient is unstable. In addition it is radiation-free and allows serial imaging. CUS possibilities have steadily expanded. However, in many neonatal intensive care units, these possibilities are not optimally used. We present a comprehensive approach for neonatal CUS, focusing on optimal settings, different probes, multiple acoustic windows and Doppler techniques. This approach is suited for both routine clinical practice and research purposes. In a live demonstration, we show how this technique is performed in the neonatal intensive care unit. Using optimal settings and probes allows for better imaging quality and improves the diagnostic value of CUS in experienced hands. Traditionally, images are obtained through the anterior fontanel. Use of supplemental acoustic windows (lambdoid, mastoid, and lateral fontanels) improves detection of brain injury. Adding Doppler studies allows screening of patency of large intracranial arteries and veins. Flow velocities and indices can be obtained. Doppler CUS offers the possibility of detecting cerebral sinovenous thrombosis at an early stage, creating a window for therapeutic intervention prior to thrombosis-induced tissue damage. Equipment, data storage and safety aspects are also addressed.


Assuntos
Encéfalo/anatomia & histologia , Ecoencefalografia/métodos , Encéfalo/irrigação sanguínea , Encefalopatias/diagnóstico por imagem , Ecoencefalografia/instrumentação , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal , Ultrassonografia Doppler Transcraniana/instrumentação , Ultrassonografia Doppler Transcraniana/métodos
4.
Front Hum Neurosci ; 8: 1068, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25628560

RESUMO

INTRODUCTION: Preterm infants are born during critical stages of brain development, in which the adaptive capacity of the fetus to extra-uterine environment is limited. Inadequate brain perfusion has been directly linked to preterm brain damage. Advanced high-frequency ultrasound probes and processing algorithms allow visualization of microvessels and depiction of regional variation. To assess whether visualization and flow velocity estimates of preterm cerebral perfusion using Doppler techniques are accurate, we conducted an in vitro experiment using a microvessel flow phantom. MATERIALS AND METHODS: An in-house developed flow phantom containing two microvessels (inner diameter 200 and 700 µm) with attached syringe pumps, filled with blood-mimicking fluid, was used to generate non-pulsatile perfusion of variable flow. Measurements were performed using an Esaote MyLab70 scanner. RESULTS: Microvessel mimicking catheters with velocities as low as 1 cm/s were adequately visualized with a linear ultrasound probe. With a convex probe, velocities <2 cm/s could not be depicted. Within settings, velocity and diameter measurements were highly reproducible [intra-class correlation 0.997 (95% CI 0.996-0.998) and 0.914 (0.864-0.946)]. Overall, mean velocity was overestimated up to threefold, especially in high velocity ranges. Significant differences were seen in velocity measurements when using steer angle correction and in vessel diameter estimation (p < 0.05). CONCLUSION: Visualization of microvessel-size catheters mimicking small brain vessels is feasible. Reproducible velocity and diameter results can be obtained, although important overestimation of the values is observed. Before velocity estimates of microcirculation can find its use in clinical practice, calibration of the ultrasound machine for any specific Doppler purpose is essential. The ultimate goal is to develop a sonographic tool that can be used for objective study of regional perfusion in routine practice.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA