RESUMO
INTRODUCTION: Staged treatment of high-energy periarticular tibia fractures involves temporization with closed reduction and external fixation, aiming to provide early reduction and stabilization while mitigating soft-tissue complications. Various external fixator configurations exist, including those that use a "multipin" clamp capable of holding multiple pins but limiting pin placement to a single plane. The purpose of this study was to compare clinical and radiographic outcomes and associated costs of standard and multipin outrigger clamp constructs in tibial plateau and pilon fractures treated with temporary external fixation. We hypothesized that use of the multipin clamp may be associated with poorly aligned reductions and increased complication rates. METHODS: A retrospective review of 100 patients with periarticular tibial plateau (AO/OTA: 41B/C) or pilon (43B/C) fracture at a Level 1 trauma center from 2014 to 2023 was conducted. Patient, injury, and complication characteristics were collected. Patients were categorized based on the external fixator clamp used: multipin (MP) or standard (S). Clinical outcomes and complication rates were assessed. Radiographic alignment was evaluated by the change in anterior and lateral distal tibial angles, and sagittal plane translation for pilon fractures, and medial and posterior proximal tibial angles for plateau fractures. RESULTS: 70 patients underwent standard (25 pilon, 45 plateau) and 30 multipin (10 pilon, 20 plateau) external fixation. MP and S groups showed no notable differences in demographics or injury characteristics. Both groups demonstrated comparable complication rates and radiological alignment outcomes, with no notable differences observed. MP constructs were more costly than standard systems. CONCLUSION: In this retrospective study of 100 patients, there was no difference in radiographic or clinical outcomes between the standard frame and multipin frame groups. Typical costs for the multipin frame constructs were $635 to $1249 more than the standard frame constructs.
Assuntos
Fixadores Externos , Fixação de Fratura , Fraturas da Tíbia , Humanos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Estudos Retrospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Fixação de Fratura/métodos , Fixação de Fratura/instrumentação , Resultado do Tratamento , Radiografia , IdosoRESUMO
Case report: Chopart joint fracture-dislocations are rare injuries. The purpose of this report is to present the management of a high energy trans-cuboid Chopart dislocation. This fracture-dislocation dislocation was treated with closed reduction, provisional fixation, and definitively with a combination of open reduction internal fixation (ORIF) and a lateral column external fixator. Due to persistent pain and Chopart joint collapse, the patient ultimately required a double arthrodesis. Conclusion: While rare, Chopart joint fracture-dislocations are impactful injuries that require prompt diagnosis and specialized management. The description of this high energy trans-cuboid Chopart dislocation and the stepwise approach for its management may be useful for other surgeons who encounter similar injuries.
RESUMO
Background: Provisional stabilization of high-energy tibia fractures using temporary plate fixation (TPF) or external fixation (ex-fix) prior to definitive medullary nailing (MN) is a strategy common in damage control orthopaedics. There is a lack of comprehensive data evaluating outcomes between these methods. This study compares outcomes of patients stabilized with either TPF or ex-fix, and with early definitive MN only, assessing complications including nonunion and deep infection. Methods: A retrospective review was performed on adult patients with tibia fractures treated with MN followed until fracture union (≥3 months) at a single level-1 trauma center from 2014 to 2022. Medical records were evaluated for nonunion and deep infection. Demographics, injury characteristics, and fixation methods were recorded. Significance between patients who underwent TPF and ex-fix was compared with a matched cohort of early MN using Pearson's exact tests, independent t-tests, and one-way ANOVA, depending on the appropriate variable. Results: 81 patients were included; 27 were temporized with TPF (n = 12) or ex-fix (n = 15). 54 early MN cases defined the matched cohort. All groups had similar patient and fracture characteristics. The difference in rates of nonunion between groups was significant, with TPF, ex-fix, and early MN groups at 17, 40, and 11% respectively (p = 0.027). Early MN had lower rates of nonunion (11% vs. 40%, p = 0.017) and deep infection (13% vs. 40%, p = 0.028) compared to ex-fix. Conclusion: Temporary ex-fix followed by staged MN was associated with higher rates of nonunion and deep infection. There was no difference in complication rates between TPF and early definitive MN. These data suggest that ex-fix followed by MN of tibia fractures should be avoided in favor of early definitive MN when possible. If temporization is needed, TPF may be a better option than ex-fix. Level of Evidence: IV.
Assuntos
Placas Ósseas , Fraturas da Tíbia , Humanos , Fraturas da Tíbia/cirurgia , Masculino , Estudos Retrospectivos , Feminino , Adulto , Pessoa de Meia-Idade , Resultado do Tratamento , Fixação de Fratura/métodos , Fixadores Externos , Fixação Intramedular de Fraturas/métodos , Consolidação da Fratura , Idoso , Fraturas não Consolidadas/cirurgiaRESUMO
PURPOSE: To identify a cohort of isolated medial tibial plateau fractures treated with surgical fixation and to categorize them by Moore and Wahlquist classifications in order to determine the rate of complications with each fracture morphology and the predictive value of each classification system. We hypothesized there would be high rates of neurovascular injury, compartment syndrome, and complications overall with a higher incidence of neurovascular injury in Moore type III rim avulsion fractures and Wahlquist type C fractures that enter the plateau lateral to the tibial spines. METHODS: Patients who presented to six Level I trauma centers between 2010 and 2021 who underwent surgical fixation for isolated medial tibial plateau fractures were retrospectively reviewed. Data including demographics, radiographs, complications, and functional outcomes were collected. RESULTS: One hundred and fifty isolated medial tibial plateau fractures were included. All patients were classified by the Wahlquist classification of medial tibial plateau fractures, and 139 patients were classifiable by the Moore classification of tibial plateau fracture-dislocations. Nine percent of fractures presented with neurovascular injury: 5 % with isolated vascular injury and 6 % with isolated nerve injury. There were no significant differences in neurovascular injury by fracture type (Wahlquist p = 0.16, Moore p = 0.33). Compartment syndrome developed in two patients (1.3 %). The average final range of motion was 0.8-122° with no difference by Wahlquist or Moore classifications (p = 0.11, p = 0.52). The overall complication rate was 32 % without differences by fracture morphology. The overall rate of return to the operating room (OR) was 25 %. CONCLUSIONS: Isolated medial tibial plateau fractures often represent fracture-dislocations of the knee and should receive a meticulous neurovascular exam on presentation with a high suspicion for neurovascular injury. No specific fracture pattern was found to be predictive of neurovascular injuries, complications, or final knee range of motion. Patients should be counseled pre-operatively regarding high rates of return to the OR after the index surgery.
Assuntos
Fixação Interna de Fraturas , Amplitude de Movimento Articular , Fraturas da Tíbia , Humanos , Fraturas da Tíbia/cirurgia , Fraturas da Tíbia/diagnóstico por imagem , Fraturas da Tíbia/complicações , Masculino , Feminino , Estudos Retrospectivos , Pessoa de Meia-Idade , Adulto , Fixação Interna de Fraturas/métodos , Resultado do Tratamento , Complicações Pós-Operatórias/epidemiologia , Idoso , Lesões do Sistema Vascular/fisiopatologia , Lesões do Sistema Vascular/cirurgia , Síndromes Compartimentais/etiologia , Síndromes Compartimentais/cirurgia , Centros de Traumatologia , Radiografia , Fraturas do Planalto TibialRESUMO
PURPOSE: The retrograde femoral nailing advanced (RFNA) system (DePuy synthes) is a commonly used implant for the fixation of low distal femur and periprosthetic fractures. There is concern that the rate of distal interlock screw back-out may be higher for the RFNA compared to other nails (ON). The purpose of this study was to evaluate the incidence of interlock screw back-out and associated screw removal for RFNA versus ON, along with associated risk factors. METHODS: A retrospective comparative study of patients who underwent retrograde nailing for a distal femur fracture at an academic level one trauma center was performed. The incidence of distal interlock screw back-out and need for screw removal were compared for RFNA versus a propensity score matched cohort who received other nails. RESULTS: One hundred and ten patients underwent retrograde nailing with the RFNA for a distal femur fracture from 2015 to 2022 (average age: 66, BMI: 32, 52.7% smokers, 54.5% female, 61.8%). There was a significantly higher rate of interlock back-out in the RFNA group compared to the ON (27 patients, 24.5% vs 12 patients, 10.9%, p = 0.01), which occurred 6.3 weeks postoperatively. Screw removal rates for back-out were not significantly different for the RFNA group versus ON (8 patients, 7.3% vs 3 patients, 2.7%, p = 0.12). CONCLUSION: In this retrospective comparative study of distal femur fractures treated with retrograde nailing, the RFNA implant was associated with an increased risk of distal interlock screw back-out compared to other nails.
Assuntos
Pinos Ortopédicos , Parafusos Ósseos , Remoção de Dispositivo , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Humanos , Feminino , Fraturas do Fêmur/cirurgia , Masculino , Estudos Retrospectivos , Idoso , Fixação Intramedular de Fraturas/instrumentação , Fixação Intramedular de Fraturas/métodos , Fixação Intramedular de Fraturas/efeitos adversos , Remoção de Dispositivo/estatística & dados numéricos , Remoção de Dispositivo/métodos , Pessoa de Meia-Idade , Fatores de Risco , Pontuação de Propensão , Fraturas Femorais DistaisRESUMO
OBJECTIVES: Voxelotor can increase hemoglobin levels in patients living with sickle cell disease (SCD). A clinician who is monitoring voxelotor response may want to know whole-blood voxelotor concentration, but this cannot be measured in most clinical settings. However, voxelotor has been demonstrated to cause "peak splitting" in common methods of hemoglobin measurement such as capillary zone electrophoresis (CZE) and high-performance liquid chromatography (HPLC). We hypothesized that we could use the size of the peak split to estimate the whole-blood concentration. METHODS: Blood from people with SCD was dosed with known concentrations of voxelotor, and multiparameter regression was used to derive the relationship of voxelotor concentration to the degree of peak splitting observed. To validate these equations, 21 patients started on voxelotor at 1500 mg/d had blood samples drawn at days 0, 14, 30, and 60. Samples were sent out for gold standard voxelotor concentration testing. The derived equations were then used to calculate voxelotor concentration. RESULTS: Calculated concentrations correlated strongly with measured concentrations for both CZE (R2 = 0.83, P < .001) and HPLC (R2 = 0.76, P < .001). Voxelotor concentration also had a significant effect on increases in hemoglobin (R2 = 0.40, P < .001). CONCLUSIONS: Thus, peak splitting CZE and HPLC can be used to estimate voxelotor concentration.
Assuntos
Anemia Falciforme , Humanos , Anemia Falciforme/sangue , Cromatografia Líquida de Alta Pressão/métodos , Eletroforese Capilar/métodos , Pirazinas/sangue , Adulto , Masculino , Feminino , Hemoglobinas/análise , Benzaldeídos , PirazóisRESUMO
SUMMARY: Tibial plateau fractures with severely displaced articular injuries and significant deformity to the surrounding metaphyseal bone (including the hyperextension varus bicondylar pattern) can be challenging to stabilize due to resulting large bone voids uncontained by metaphyseal cortex. The purpose of this report was to describe a technique to support the plateau articular surface in these cases and report on outcomes of a small series. This technique uses a small or mini fragment plate, contoured to function as an intraosseous shelf plate, with the "shelf" portion inserted into the bone beneath the articular surface to support it. This technique provides fixed-angle support to the fragment. There are some advantages of this technique compared to structural allograft, large volume ceramic bone void filler, a spine cage, or other trabecular metal object, including the ability to remove the plate later, ability to tension the plate against the depressed articular surface, ability to place screws or other allograft near the implant, wide availability of the implant, and familiarity of orthopaedic trauma surgeons with placing plates and screws to hold reductions. The technique is particularly useful in patterns with uncontained articular depression and a large metaphyseal void.
Assuntos
Placas Ósseas , Fixação Interna de Fraturas , Fraturas da Tíbia , Humanos , Fraturas da Tíbia/cirurgia , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Masculino , Pessoa de Meia-Idade , Feminino , Adulto , Resultado do Tratamento , Idoso , Adulto Jovem , Fraturas do Planalto TibialRESUMO
Genetic oscillations are generated by delayed transcriptional negative feedback loops, wherein repressor proteins inhibit their own synthesis after a temporal production delay. This delay is distributed because it arises from a sequence of noisy processes, including transcription, translocation, translation, and folding. Because the delay determines repression timing and, therefore, oscillation period, it has been commonly believed that delay noise weakens oscillatory dynamics. Here, we demonstrate that noisy delay can surprisingly denoise genetic oscillators. Specifically, moderate delay noise improves the signal-to-noise ratio and sharpens oscillation peaks, all without impacting period and amplitude. We show that this denoising phenomenon occurs in a variety of well-studied genetic oscillators, and we use queueing theory to uncover the universal mechanisms that produce it.
RESUMO
We describe a trifocal femur injury with intracapsular femoral neck fracture, diaphyseal fracture with bone loss, and distal complete articular (AO/OTA C type) fracture, an injury rarely described in the literature. Surgical management utilized a not-yet-reported implant combination: screw-side plate device for the intracapsular femoral neck, retrograde nail for the diaphysis, and lag screws plus mini fragment buttress plating for the distal fracture. The patient had uneventful fracture union with no changes in alignment. Given the rarity and complexity of this injury, there is little consensus on surgical technique and implant choice. This case demonstrates a modernized approach that may be useful for surgeons who encounter similar fracture patterns in their practice.
RESUMO
Around 60% of people who are incarcerated have insomnia; 6-10 times more prevalent than the general population. Yet, there is no standardized, evidence-based approach to insomnia treatment in prison. We assessed the feasibility of a treatment pathway for insomnia in a high-secure prison to inform a future randomized controlled trial (RCT) and initial efficacy data for sleep and mental health outcomes. We used a within-participants pre-post design. The stepped-care pathway included: self-management with peer support, environmental aids, and cognitive behavioral therapy for insomnia (CBTi). Assessment measures for insomnia, well-being, mood, anxiety, suicidality, overall health, sleepiness, fatigue, and cognitive functioning were administered at baseline and pathway exit. Feasibility criteria included eligibility to participate, CBTi uptake, and assessment completion. Forty-two adult males who are incarcerated were approached of which 95.2% were eligible. Of those deemed eligible, most participated (36/40, 90.0%). Most who completed baseline completed post-assessments (28/36, 77.8%) and of these, most showed improvements in their subjective sleep (27/28, 96.4%). Large reductions were found from pre- to posttreatment in insomnia severity (dâ =â -1.81, 95% CI: 8.3 to 12.9) and 57.0% reported no clinically significant insomnia symptoms at post-assessment. There was no overall change in actigraphy-measured sleep. Large treatment benefits were found for depression, anxiety, well-being, and cognitive functioning, with a medium benefit on suicidal ideation. The treatment pathway for insomnia in prison was feasible and may be an effective treatment for insomnia in people who are incarcerated, with additional promising benefits for mental health. A pragmatic RCT across different prison populations is warranted. This paper is part of the Sleep and Circadian Health in the Justice System Collection.
RESUMO
OBJECTIVES: To compare clinical and radiographic outcomes after retrograde intramedullary nailing (rIMN) versus locked plating (LP) of "extreme distal" periprosthetic femur fractures, defined as those that contact or extend distal to the anterior flange. DESIGN: Retrospective review. SETTING: Eight academic level I trauma centers. PATIENT SELECTION CRITERIA: Adult patients with periprosthetic distal femur fractures at or distal to the anterior flange (OTA/AO 33B-C[VB1]) treated with rIMN or LP. OUTCOME MEASURES AND COMPARISONS: The primary outcome was reoperation to promote healing or to treat infection (reoperation for elective removal of symptomatic hardware was excluded from this analysis). Secondary outcomes included nonunion, delayed union, fixation failure, infection, overall reoperation rate, distal femoral alignment, and ambulatory status at final follow-up. Outcomes were compared between patients treated with rIMN or LP. RESULTS: Seventy-one patients treated with rIMN and 224 patients treated with LP were included. The rIMN group had fewer points of fixation in the distal segment (rIMN: 3.5 ± 1.1 vs. LP: 6.0 ± 1.1, P < 0.001) and more patients who were allowed to weight-bear as tolerated immediately postoperatively (rIMN: 45%; LP: 9%, P < 0.01). Reoperation to promote union and/or treat infection was 8% in the rIMN group and 16% in the LP group ( P = 0.122). There were no significant differences in nonunion ( P > 0.999), delayed union ( P = 0.079), fixation failure ( P > 0.999), infection ( P = 0.084), or overall reoperation rate ( P > 0.999). Significantly more patients in the rIMN group were ambulatory without assistive devices at final follow-up (rIMN: 35%, LP: 18%, P = 0.008). CONCLUSIONS: rIMN of extreme distal periprosthetic femur fractures has similar complication rates compared with LP, with a possible advantage of earlier return to weight-bearing. Surgeons can consider this treatment strategy in all fractures with stable implants and amenable prosthesis geometry, even extreme distal fractures. LEVEL OF EVIDENCE: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
Assuntos
Artroplastia do Joelho , Fraturas do Fêmur , Fixação Intramedular de Fraturas , Fraturas Periprotéticas , Adulto , Humanos , Fixação Intramedular de Fraturas/efeitos adversos , Estudos Retrospectivos , Fraturas do Fêmur/etiologia , Consolidação da Fratura , Placas Ósseas/efeitos adversos , Fixação Interna de Fraturas , Fêmur/cirurgia , Fraturas Periprotéticas/complicações , Artroplastia do Joelho/efeitos adversos , Resultado do TratamentoAssuntos
Diagnóstico Tardio , Equimose , Humanos , Masculino , Pessoa de Meia-Idade , Equimose/diagnóstico , Edema/diagnóstico , Hispânico ou LatinoRESUMO
OBJECTIVES: The sagittal plane of the distal tibia has not been well-described. This study sought to characterize sagittal plane morphology, determine symmetry from side to side, and identify differences based on hindfoot alignment. METHODS: One hundred twelve bilateral lateral weight-bearing ankle radiographs were retrospectively evaluated (224 ankles). Hindfoot alignment was classified as neutral, planus, or cavus using the Meary angle. The angle between the diaphyseal and distal tibia axes was measured, and the apex location relative to the plafond was recorded. RESULTS: A mean distal tibia apex posterior angulation (DTAPA) of 2.0° (range -2° to 7°, SD = 2.06°) was located 8.0 cm proximal to the plafond. No difference was observed from side to side in DTAPA magnitude (P = 0.36) or location (P = 0.90). Planus alignment was associated with a significantly greater DTAPA (3.05°) as compared with neutral (1.89°) (P = 0.002) and cavus (1.25°) (P < 0.001) alignment. CONCLUSION: The distal tibia has an apex posterior angulation, suggesting that the true anatomic axis of the tibia terminates just posterior to the plafond center. Hindfoot alignment is related to distal tibia morphology. DTAPA symmetry indicates that contralateral imaging can be used to guide reconstruction of patient-specific anatomy and alignment. Knowledge of the DTAPA may help mitigate sagittal malalignment during distal tibia fracture surgery.
Assuntos
Pé , Tíbia , Humanos , Tíbia/diagnóstico por imagem , Tíbia/cirurgia , Estudos Retrospectivos , Extremidade Inferior , TornozeloRESUMO
PURPOSE: Interfragmentary strain influences whether a fracture will undergo direct and indirect fracture healing. Orthopedic trauma surgeons modulate strain and create optimal biomechanical environments for specific fracture patterns using fixation constructs. However, objective intraoperative interfragmentary strain measurement does not currently inform fixation strategy in common practice. This review identifies potential methods and technologies to enable intraoperative strain measurement for guiding optimal fracture fixation strategies. METHODS: PubMed, Scopus, and Web of Science were methodologically queried for manuscripts containing terms related to "bone fracture," "strain," "measurement," and "intraoperative." Manuscripts were systematically screened for relevance and adjudicated by three reviewers. Relevant articles describing methods to measure interfragmentary strain intraoperatively were summarized. RESULTS: After removing duplicates, 1404 records were screened initially. There were 49 manuscripts meeting criteria for in-depth review. Of these, four reports were included in this study that described methods applicable to measuring interfragmentary strain intraoperatively. Two of these reports described a method using instrumented staples, one described optical tracking of Kirschner wires, and one described using a digital linear variable displacement transducer with a custom external fixator. CONCLUSION: The four reports identified by this review describe potential methods to quantify interfragmentary strain after fixation. However, further studies are needed to confirm the precision and accuracy of these measurements across a range of fractures and fixation methods. Additionally, described methods require the insertion and likely removal of additional implants into the bone. Ideally, innovations that measure interfragmentary strain intraoperatively would provide dynamic biomechanical feedback for the surgeon to proactively modulate construct stability.
Assuntos
Fixação Interna de Fraturas , Fraturas Ósseas , Humanos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Fios Ortopédicos , Consolidação da Fratura , Tomada de Decisões , Fenômenos BiomecânicosRESUMO
Modern blocking techniques are useful to achieve anatomic alignment and stable fixation during end-segment nailing. Whether with screws or drill bits, blocking implants can correct both angular and translational deformities. Understanding the biomechanics of blocking implants allows the surgeon to properly plan their placement based on principles rather than dogma. We use case examples to highlight updates in blocking techniques during acute surgical fixation and chronic deformity correction.
Assuntos
Fixação Intramedular de Fraturas , Humanos , Fixação Intramedular de Fraturas/métodos , Parafusos Ósseos , Extremidade InferiorRESUMO
Case report: Traumatic hip dislocations require prompt diagnosis and reduction to preserve the native joint. The classic irreducible posterior hip fracture-dislocation has been described as an immobile, slightly flexed, and internally rotated hip on physical exam. Classically, this irreducible pattern is associated with an ipsilateral femoral head fracture. The purpose of our report is to present an irreducible posterior hip dislocation with preserved motion in the setting of an unstable pelvic ring injury without associated femoral head pathology. Despite lacking clinical features of an irreducible hip, closed reduction in the emergency and operating rooms was unsuccessful, even after frame application for pelvis stability. Persistent irreducibility necessitated open reduction, where the femoral head was found to be buttonholed through the posterior hip capsule and blocking reduction. Conclusion: A posteriorly dislocated hip with preserved motion in the setting of a concomitant unstable pelvic ring injury may belie the true locked nature of the femoroacetabular dislocation and high suspicion for femoral head incarceration is required. The description of this unique irreducible fracture pattern and the stepwise approach used for reduction may be useful for other surgeons who may encounter similar patterns of injury.
RESUMO
Background: Cancer patients show increased morbidity with COVID-19 and need effective immunization strategies. Many healthcare regulatory agencies recommend administering 'booster' doses of COVID-19 vaccines beyond the standard two-dose series, for this group of patients. Therefore, studying the efficacy of these additional vaccine doses against SARS-CoV-2 and variants of concern is of utmost importance in this immunocompromised patient population. Methods: We conducted a prospective single arm clinical trial enrolling patients with cancer that had received two doses of mRNA or one dose of AD26.CoV2.S vaccine and administered a third dose of mRNA vaccine. We further enrolled patients that had no or low responses to three mRNA COVID vaccines and assessed the efficacy of a fourth dose of mRNA vaccine. Efficacy was assessed by changes in anti-spike antibody, T-cell activity, and neutralization activity, which were again assessed at baseline and 4 weeks. Results: We demonstrate that a third dose of COVID-19 vaccine leads to seroconversion in 57% of patients that were seronegative after primary vaccination series. The immune response is durable as assessed by anti-SARS-CoV-2 (anti-S) antibody titers, T-cell activity, and neutralization activity against wild-type (WT) SARS-CoV2 and BA1.1.529 at 6 months of follow-up. A subset of severely immunocompromised hematologic malignancy patients that were unable to mount an adequate immune response (titer <1000 AU/mL) after the third dose and were treated with a fourth dose in a prospective clinical trial which led to adequate immune boost in 67% of patients. Low baseline IgM levels and CD19 counts were associated with inadequate seroconversion. Booster doses induced limited neutralization activity against the Omicron variant. Conclusions: These results indicate that third dose of COVID vaccine induces durable immunity in cancer patients and an additional dose can further stimulate immunity in a subset of patients with inadequate response. Funding: Leukemia Lymphoma Society, National Cancer Institute. Clinical trial number: NCT05016622.
People with cancer have a higher risk of death or severe complications from COVID-19. As a result, vaccinating cancer patients against COVID-19 is critical. But patients with cancer, particularly blood or lymphatic system cancers, are less likely to develop protective immunity after COVID-19 vaccination. Immune suppression caused by cancer or cancer therapies may explain the poor vaccine response. Booster doses of the vaccine may improve the vaccine response in patients with cancer. But limited information is available about how well booster doses protect patients with cancer against COVID-19. Thakkar et al. show that a third dose of a COVID-19 vaccine can induce a protective immune response in half of the patients with cancer with no immunity after the first two doses. In the experiments, Thakkar et al. tracked the immune reaction to COVID-19 booster shots in 106 cancer patients. A third booster dose protected patients for up to four to six months and reduced breakthrough infection rates to low levels. Eighteen patients with blood cancers and severe immune suppression had an inadequate immune response after three doses of the vaccine; a fourth dose boosted the immune response for two-thirds of them, which for some included neutralization of variants such as Omicron. The experiments show that booster doses can increase COVID-19 vaccine protection for patients with cancer, even those who do not respond to the initial vaccine series. Thakkar et al. also show that pre-vaccine levels of two molecules linked to the immune system, (immunoglobin M and the CD19 antigen) predicted the patients' vaccine response, which might help physicians identify which individuals would benefit from booster doses.
Assuntos
COVID-19 , Neoplasias , Humanos , Vacinas contra COVID-19 , Ad26COVS1 , Estudos Prospectivos , RNA Viral , COVID-19/prevenção & controle , SARS-CoV-2 , Neoplasias/terapia , Imunidade , Anticorpos AntiviraisRESUMO
INTRODUCTION: An understanding of the sagittal plane morphology of the humerus is relevant during surgical fixation of humeral fractures but is not well described in the literature. The purpose of this study was to better characterize the native sagittal plane morphology of the humerus. MATERIALS AND METHODS: 170 patients with uninjured full length lateral humerus radiographs were retrospectively evaluated. The angle between the proximal humeral diaphyseal axis and the distal humeral diaphyseal axis was identified and measured. The proximal axis was defined by two points equidistant from the anterior and posterior cortex 10 mm and 100 mm distal to the metaphyseal flare, and the distal axis by two points at 10 mm and 50 mm proximal to the capitellum/trochlea. The relative location of the center of rotation of angulation (CORA) was calculated as a percentage of humeral length. RESULTS: 114 radiographs were included in the analysis (66 right humeri, 48 left humeri). The average apex posterior angulation was 6.5 +/- 2.9°. The CORA occurred at an average of 80% (SD+/-13%) of the length of the humerus (proximal to distal). Total humeral length and absolute distance to CORA were greater in males compared to females (364 ± 50 mm versus 326 ± 30 mm; p<0.001; 290 ± 68 mm versus 260 ± 48 mm; p=0.003), but there were no significant sex differences with respect to magnitude of the apex posterior angulation (p=0.077) or location of CORA as a percentage of total humeral length (p=0.916). There were no statistically significant associations between age and total humeral length (p=0.056), distance to CORA (p=0.130), location of CORA as percentage of total humeral length (p=0.753), or magnitude of angulation (p=0.075). CONCLUSION: An apex posterior bow consistently exists in the distal one-quarter of the humerus that is consistent across ages and between sexes. This normal anatomic bow is important to recognize to avoid an extension malreduction and has implications for implant fit and contouring.