Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
PLoS One ; 15(12): e0242983, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33259507

RESUMO

BACKGROUND: Antepartum fetal monitoring aims to assess fetal development and wellbeing throughout pregnancy. Current methods utilised in clinical practice are intermittent and only provide a 'snapshot' of fetal wellbeing, thus key signs of fetal demise could be missed. Continuous fetal monitoring (CFM) offers the potential to alleviate these issues by providing an objective and longitudinal overview of fetal status. Various CFM devices exist within literature; this review planned to provide a systematic overview of these devices, and specifically aimed to map the devices' design, performance and factors which affect this, whilst determining any gaps in development. METHODS: A systematic search was conducted using MEDLINE, EMBASE, CINAHL, EMCARE, BNI, Cochrane Library, Web of Science and Pubmed databases. Following the deletion of duplicates, the articles' titles and abstracts were screened and suitable papers underwent a full-text assessment prior to inclusion in the review by two independent assessors. RESULTS: The literature searches generated 4,885 hits from which 43 studies were included in the review. Twenty-four different devices were identified utilising four suitable CFM technologies: fetal electrocardiography, fetal phonocardiography, accelerometry and fetal vectorcardiography. The devices adopted various designs and signal processing methods. There was no common means of device performance assessment between different devices, which limited comparison. The device performance of fetal electrocardiography was reduced between 28 to 36 weeks' gestation and during high levels of maternal movement, and increased during night-time rest. Other factors, including maternal body mass index, fetal position, recording location, uterine activity, amniotic fluid index, number of fetuses and smoking status, as well as factors which affected alternative technologies had equivocal effects and require further investigation. CONCLUSIONS: A variety of CFM devices have been developed, however no specific approach or design appears to be advantageous due to high levels of inter-device and intra-device variability.


Assuntos
Monitorização Fetal/instrumentação , Cuidado Pré-Natal , Acelerometria , Eletrocardiografia , Feminino , Movimento Fetal , Idade Gestacional , Frequência Cardíaca Fetal/fisiologia , Humanos , Gravidez , Processamento de Sinais Assistido por Computador
2.
IEEE Trans Pattern Anal Mach Intell ; 42(7): 1642-1653, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32305899

RESUMO

Camera sensors rely on global or rolling shutter functions to expose an image. This fixed function approach severely limits the sensors' ability to capture high-dynamic-range (HDR) scenes and resolve high-speed dynamics. Spatially varying pixel exposures have been introduced as a powerful computational photography approach to optically encode irradiance on a sensor and computationally recover additional information of a scene, but existing approaches rely on heuristic coding schemes and bulky spatial light modulators to optically implement these exposure functions. Here, we introduce neural sensors as a methodology to optimize per-pixel shutter functions jointly with a differentiable image processing method, such as a neural network, in an end-to-end fashion. Moreover, we demonstrate how to leverage emerging programmable and re-configurable sensor-processors to implement the optimized exposure functions directly on the sensor. Our system takes specific limitations of the sensor into account to optimize physically feasible optical codes and we evaluate its performance for snapshot HDR and high-speed compressive imaging both in simulation and experimentally with real scenes.

3.
Artigo em Inglês | MEDLINE | ID: mdl-21768017

RESUMO

This paper describes the design of a programmable transmit beamformer application-specific integrated circuit (ASIC) with 8 channels for ultrasound imaging systems. The system uses a 20-MHz reference clock. A digital delay-locked loop (DLL) was designed with 50 variable delay elements, each of which provides a clock with different phase from a single reference. Two phase detectors compare the phase difference of the reference clock with the feedback clock, adjusting the delay of the delay elements to bring the feedback clock signal in phase with the reference clock signal. Two independent control voltages for the delay elements ensure that the mark space ratio of the pulses remain at 50%. By combining a 10- bit asynchronous counter with the delays from the DLL, each channel can be programmed to give a maximum time delay of 51 µs with 1 ns resolution. It can also give bursts of up to 64 pulses. Finally, for a single pulse, it can adjust the pulse width between 9 ns and 100 ns by controlling the current flowing through a capacitor in a one-shot circuit, for use with 40-MHz and 5-MHz transducers, respectively.


Assuntos
Processamento de Sinais Assistido por Computador , Ultrassonografia/instrumentação , Desenho de Equipamento , Retroalimentação
4.
Artigo em Inglês | MEDLINE | ID: mdl-19686993

RESUMO

A scanning head has been designed and fabricated that incorporates a 20-MHz, 128-element linear transducer. The scanning head also incorporates -200 V pulsers and a custom 16-channel amplifier. The transducer was constructed with 28 microm PVDF film with an element pitch of 250 microm. The transducer showed an average -20 dB pulse length of 69 ns. The elements of the PVDF array were tested and found to have 7.5 mPa/ radical Hz equivalent noise pressure. The radiated power level for 32 pulsed elements was approximately 1 MPa. An imaging test shows that the system achieves axial and lateral resolutions of 40 microm and 0.2 mm, respectively. The entire scanning head dissipates approximately 1.6 W at a pulse repetition rate of 750 Hz.


Assuntos
Modelos Teóricos , Polivinil/química , Transdutores , Ultrassonografia/instrumentação , Algoritmos , Amplificadores Eletrônicos , Braço/irrigação sanguínea , Braço/diagnóstico por imagem , Desenho de Equipamento , Humanos , Pele/diagnóstico por imagem
5.
Appl Opt ; 44(31): 6578-92, 2005 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-16270546

RESUMO

Design requirements for an 8000 frame/s dual-wavelength ratiometric chemical species tomography system, intended for hydrocarbon vapor imaging in one cylinder of a standard automobile engine, are examined. The design process is guided by spectroscopic measurements on iso-octane and by comprehensive results from laboratory phantoms and research engines, including results on temporal resolution performance. Novel image reconstruction techniques, necessary for this application, are presented. Recent progress toward implementation, including details of the optical access arrangement employed and signal-to-noise issues, is described. We present first cross-cylinder IR absorption measurements from a reduced channel-count (nontomographic) system and discuss the prospects for imaging.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA