Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Integr Environ Assess Manag ; 14(3): 316-334, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29424474

RESUMO

Per- and polyfluoroalkyl substances (PFAS) are a group of fluorinated substances that are in the focus of researchers and regulators due to widespread presence in the environment and biota, including humans, of perfluorooctane sulfonate (PFOS) and perfluorooctanoic acid (PFOA). Fluoropolymers, high molecular weight polymers, have unique properties that constitute a distinct class within the PFAS group. Fluoropolymers have thermal, chemical, photochemical, hydrolytic, oxidative, and biological stability. They have negligible residual monomer and oligomer content and low to no leachables. Fluoropolymers are practically insoluble in water and not subject to long-range transport. With a molecular weight well over 100 000 Da, fluoropolymers cannot cross the cell membrane. Fluoropolymers are not bioavailable or bioaccumulative, as evidenced by toxicology studies on polytetrafluoroethylene (PTFE): acute and subchronic systemic toxicity, irritation, sensitization, local toxicity on implantation, cytotoxicity, in vitro and in vivo genotoxicity, hemolysis, complement activation, and thrombogenicity. Clinical studies of patients receiving permanently implanted PTFE cardiovascular medical devices demonstrate no chronic toxicity or carcinogenicity and no reproductive, developmental, or endocrine toxicity. This paper brings together fluoropolymer toxicity data, human clinical data, and physical, chemical, thermal, and biological data for review and assessment to show that fluoropolymers satisfy widely accepted assessment criteria to be considered as "polymers of low concern" (PLC). This review concludes that fluoropolymers are distinctly different from other polymeric and nonpolymeric PFAS and should be separated from them for hazard assessment or regulatory purposes. Grouping fluoropolymers with all classes of PFAS for "read across" or structure-activity relationship assessment is not scientifically appropriate. Integr Environ Assess Manag 2018;14:316-334. © 2018 The Authors. Integrated Environmental Assessment and Management published by Wiley Periodicals, Inc. on behalf of Society of Environmental Toxicology & Chemistry (SETAC).


Assuntos
Polímeros de Fluorcarboneto/química , Polímeros de Fluorcarboneto/toxicidade , Poluentes Químicos da Água/química , Poluentes Químicos da Água/toxicidade , Monitoramento Ambiental/legislação & jurisprudência , Substâncias Perigosas , Humanos
2.
J Emerg Med ; 46(5): 620-3, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24440619

RESUMO

BACKGROUND: There are several previously documented findings for electrocardiograms (ECGs) of spontaneous pneumothorax. These findings include axis deviation, T-wave inversion, and right bundle branch block. When an ECG has the arm leads incorrectly placed, the ECG will display right axis deviation and inversion of the P waves in lead I. There have been no previously published ECGs of spontaneous pneumothorax that have shown the same findings as reversal of the limb leads of an ECG. OBJECTIVES: A possible finding of spontaneous pneumothorax is an identical finding to that of an ECG that has been flagged for limb lead reversal. CASE REPORT: A patient presented in the emergency setting with acute chest pain and shortness of breath caused by a tension pneumothorax. An ECG was administered; findings indicated reversal of the arm leads (right axis deviation and inverted P waves in lead I), but there was no actual limb lead reversal present. ECG findings resolved upon resolution of the pneumothorax. CONCLUSIONS: If a patient presents with chest pain and shortness of breath, and the patient's ECG is flagged for limb lead reversal despite being set up correctly, the physician should raise clinical suspicion for a possible spontaneous pneumothorax.


Assuntos
Pneumotórax/diagnóstico , Idoso , Dor no Peito/etiologia , Eletrocardiografia , Humanos , Masculino , Pneumotórax/complicações , Pneumotórax/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA