Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Circ Arrhythm Electrophysiol ; 17(2): e012377, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38288627

RESUMO

BACKGROUND: The incidence and prognosis of right bundle branch block (RBBB) following transcatheter aortic valve replacement (TAVR) are unknown. Hence, we sought to characterize the incidence of post-TAVR RBBB and determine associated risks of permanent pacemaker (PPM) implantation and mortality. METHODS: All patients 18 years and above without preexisting RBBB or PPM who underwent TAVR at US Mayo Clinic sites and Mayo Clinic Health Systems from June 2010 to May 2021 were evaluated. Post-TAVR RBBB was defined as new-onset RBBB in the postimplantation period. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. The risks of PPM implantation (within 90 days) and mortality following TAVR were compared for patients with and without post-TAVR RBBB using Kaplan-Meier analysis and Cox proportional hazards modeling. RESULTS: Of 1992 patients, 15 (0.75%) experienced new RBBB post-TAVR. There was a higher degree of valve oversizing among patients with new RBBB post-TAVR versus those without (17.9% versus 10.0%; P=0.034). Ten patients (66.7%) with post-TAVR RBBB experienced high-grade atrioventricular block and underwent PPM implantation (median 1 day; Q1, 0.2 and Q3, 4), compared with 268/1977 (13.6%) without RBBB. Following propensity score adjustment for covariates (age, sex, balloon-expandable valve, annulus diameter, and valve oversizing), post-TAVR RBBB was significantly associated with PPM implantation (hazard ratio, 8.36 [95% CI, 4.19-16.7]; P<0.001). No statistically significant increase in mortality was seen with post-TAVR RBBB (hazard ratio, 0.83 [95% CI, 0.33-2.11]; P=0.69), adjusting for age and sex. CONCLUSIONS: Although infrequent, post-TAVR RBBB was associated with elevated PPM implantation risk. The mechanisms for its development and its clinical prognosis require further study.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Bloqueio de Ramo/diagnóstico , Bloqueio de Ramo/epidemiologia , Bloqueio de Ramo/etiologia , Estenose da Valva Aórtica/cirurgia , Incidência , Estimulação Cardíaca Artificial/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Valva Aórtica/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA