Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 109
Filtrar
1.
ANZ J Surg ; 94(4): 697-701, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38041237

RESUMO

BACKGROUND: Prolonged postoperative ileus (PPOI) is associated with higher morbidity and extended inpatient stay. Although evidence suggests that PPOI is more common following right-sided resections, it is uncertain if return to bowel function is similar following extended right (ERH) versus right hemicolectomy (RH). METHODS: The recovery of patients undergoing ERH and RH in a regional hospital in New Zealand was retrospectively compared, from 2012 to 2021. Rates of PPOI, return of bowel function and postoperative complications were compared. Other factors potentially relating to PPOI were analysed. RESULTS: 293 patients were included (42 who underwent ERH, and 251 RH). PPOI was more common following ERH than RH (43% vs. 25%, P = 0.02). When accounting for the operative approach, rate of PPOI was not significantly different (42% open ERH vs. 36% open RH; P = 0.56). Excluding PPOI, return of bowel function did not differ between groups. Patient undergoing ERH versus RH had significantly higher length of stay (1 day) and Hb drop (2.5 g/L) postoperatively. CONCLUSION: Higher rates of PPOI have been demonstrated in ERH versus RH however when controlling for approach, there was not a significant difference. Further interrogation into rates of PPOI (particularly after laparoscopic surgery) are warranted to tailor locoregional ERAS protocols.


Assuntos
Íleus , Laparoscopia , Humanos , Estudos Retrospectivos , Defecação , Colectomia/efeitos adversos , Colectomia/métodos , Laparoscopia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Íleus/epidemiologia , Íleus/etiologia
2.
Am J Gastroenterol ; 119(2): 331-341, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-37782524

RESUMO

INTRODUCTION: Gastric emptying testing (GET) assesses gastric motility, however, is nonspecific and insensitive for neuromuscular disorders. Gastric Alimetry (GA) is a new medical device combining noninvasive gastric electrophysiological mapping and validated symptom profiling. This study assessed patient-specific phenotyping using GA compared with GET. METHODS: Patients with chronic gastroduodenal symptoms underwent simultaneous GET and GA, comprising a 30-minute baseline, 99m TC-labelled egg meal, and 4-hour postprandial recording. Results were referenced to normative ranges. Symptoms were profiled in the validated GA App and phenotyped using rule-based criteria based on their relationships to the meal and gastric activity: (i) sensorimotor, (ii) continuous, and (iii) other. RESULTS: Seventy-five patients were assessed, 77% female. Motility abnormality detection rates were as follows: GET 22.7% (14 delayed, 3 rapid), GA spectral analysis 33.3% (14 low rhythm stability/low amplitude, 5 high amplitude, and 6 abnormal frequency), and combined yield 42.7%. In patients with normal spectral analysis, GA symptom phenotypes included sensorimotor 17% (where symptoms strongly paired with gastric amplitude, median r = 0.61), continuous 30%, and other 53%. GA phenotypes showed superior correlations with Gastroparesis Cardinal Symptom Index, Patient Assessment of Upper Gastrointestinal Symptom Severity Index, and anxiety scales, whereas Rome IV Criteria did not correlate with psychometric scores ( P > 0.05). Delayed emptying was not predictive of specific GA phenotypes. DISCUSSION: GA improves patient phenotyping in chronic gastroduodenal disorders in the presence and absence of motility abnormalities with increased correlation with symptoms and psychometrics compared with gastric emptying status and Rome IV criteria. These findings have implications for the diagnostic profiling and personalized management of gastroduodenal disorders.


Assuntos
Duodenopatias , Gastroparesia , Humanos , Feminino , Masculino , Esvaziamento Gástrico/fisiologia , Gastroparesia/diagnóstico por imagem , Cintilografia
3.
Transl Vis Sci Technol ; 12(12): 19, 2023 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-38127324

RESUMO

Purpose: This optical bench study was designed to evaluate and compare the halos generated by presbyopia-correcting intraocular lenses (PCIOLs) and monofocal intraocular lenses (IOLs), with or without lens decentration, using an optical bench to simulate the headlight of a distant vehicle in mesopic conditions. Methods: Halos generated by six nondiffractive and 10 diffractive IOLs with different dioptric add powers were evaluated using a high dynamic range bench system. Halo intensities were compared by assessing the area under the measured intensity profile curve to compute the relative halo magnitude (RHM). Results: Nondiffractive PCIOLs produced smaller and less intense bench halo images than diffractive ones. RHM measurements ranged from 964 to 1896. Monofocal IOLs produced lower RHM values, whereas diffractive PCIOLs generated higher ones. When decentered by 0.5 mm with respect to the system aperture, more obviously asymmetric halo image profiles were observed in diffractive compared with nondiffractive PCIOLs. Conclusions: Simulated bench halos of nondiffractive PCIOLs are smaller and less intense than those of diffractive PCIOLs. Additional clinical studies assessing standardized patient-reported outcomes measures are required to correlate these bench results with patient satisfaction. Translational Relevance: This study contrasts the design-related simulated bench halos of nondiffractive and diffractive PCIOLs, aiming to elucidate their impact on halo perception.


Assuntos
Lentes Intraoculares , Presbiopia , Humanos , Presbiopia/cirurgia
5.
Urol Pract ; 10(5): 475, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37409953
6.
Pain Med ; 24(12): 1332-1340, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37428157

RESUMO

BACKGROUND: Genicular nerve radiofrequency ablation (GNRFA) is an effective treatment for chronic knee pain. However, there has been minimal investigation of real-world, long-term outcomes and factors that predict treatment success after GNRFA. OBJECTIVES: To evaluate the effectiveness of GNRFA for chronic knee pain in a real-world population and identify predictive factors. METHODS: Consecutive patients who underwent GNRFA at a tertiary academic center were identified. Demographic, clinical, and procedural characteristics were collected from the medical record. Outcome data were numeric rating scale (NRS) pain reduction and Patient Global Impression of Change (PGIC). Data were collected by standardized telephone survey. Predictors of success were evaluated with logistic and Poisson regression analyses. RESULTS: Of the 226 total patients identified, 134 (65.6 ± 12.7; 59.7% female) were successfully contacted and analyzed, with a mean follow-up time of 23.3 ± 11.0 months. Of those, 47.8% (n = 64; 95% CI: 39.5%-56.2%) and 61.2% (n = 82; 95% CI: 52.7%-69.0%) reported ≥50% NRS score reduction and ≥2-point NRS score reduction, respectively, and 59.0% (n = 79; 95% CI: 50.5%-66.9%) reported "much improved" on the PGIC questionnaire. Factors associated with a greater likelihood of treatment success (P < .05) were higher Kellgren-Lawrence osteoarthritis grade (2-4 vs 0-1); no baseline opioid, antidepressant, or anxiolytic medication use; and >3 nerves targeted. CONCLUSION: In this real-world cohort, approximately half of the participants experienced clinically meaningful improvements in knee pain after GNRFA at an average follow-up time of nearly 2 years. Factors associated with higher likelihood of treatment success were more advanced osteoarthritis (Kellgren-Lawrence Grade 2-4); no opioid, antidepressant, or anxiolytic medication use; and >3 nerves targeted.


Assuntos
Ansiolíticos , Osteoartrite do Joelho , Ablação por Radiofrequência , Humanos , Feminino , Masculino , Estudos de Coortes , Osteoartrite do Joelho/complicações , Prognóstico , Articulação do Joelho/cirurgia , Articulação do Joelho/inervação , Resultado do Tratamento , Dor/complicações , Antidepressivos , Artralgia/cirurgia , Artralgia/complicações
7.
Hematol Oncol Clin North Am ; 37(5): 877-892, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37330345

RESUMO

The incidence of renal cancer has increased over the past several decades, but mortality has declined. This is thought to be related in part to earlier detection of renal masses which portend excellent 5-year survival rates. Management of small renal masses and localized disease include both nonsurgical and surgical options. The choice of intervention is ultimately based on comprehensive evaluation and shared decision-making. This article provides a comprehensive review of the current surgical management options for localized renal cancer.


Assuntos
Carcinoma de Células Renais , Neoplasias Renais , Humanos , Nefrectomia , Rim , Neoplasias Renais/cirurgia , Neoplasias Renais/diagnóstico , Carcinoma de Células Renais/cirurgia , Taxa de Sobrevida
8.
medRxiv ; 2023 May 25.
Artigo em Inglês | MEDLINE | ID: mdl-37292604

RESUMO

Objectives: Gastric emptying testing (GET) assesses gastric motility, however is non-specific and insensitive for neuromuscular disorders. Gastric Alimetry® (GA) is a new medical device combining non-invasive gastric electrophysiological mapping and validated symptom profiling. This study assessed patient-specific phenotyping using GA compared to GET. Methods: Patients with chronic gastroduodenal symptoms underwent simultaneous GET and GA, comprising a 30-minute baseline, 99m TC-labelled egg meal, and 4-hour postprandial recording. Results were referenced to normative ranges. Symptoms were profiled in the validated GA App and phenotyped using rule-based criteria based on their relationships to the meal and gastric activity: i) sensorimotor; ii) continuous; and iii) other. Results: 75 patients were assessed; 77% female. Motility abnormality detection rates were: GET 22.7% (14 delayed, 3 rapid); GA spectral analysis 33.3% (14 low rhythm stability / low amplitude; 5 high amplitude; 6 abnormal frequency); combined yield 42.7%. In patients with normal spectral analysis, GA symptom phenotypes included: sensorimotor 17% (where symptoms strongly paired with gastric amplitude; median r=0.61); continuous 30%; other 53%. GA phenotypes showed superior correlations with GCSI, PAGI-SYM, and anxiety scales, whereas Rome IV Criteria did not correlate with psychometric scores (p>0.05). Delayed emptying was not predictive of specific GA phenotypes. Conclusions: GA improves patient phenotyping in chronic gastroduodenal disorders in the presence and absence of motility abnormalities with improved correlation with symptoms and psychometrics compared to gastric emptying status and Rome IV criteria. These findings have implications for the diagnostic profiling and personalized management of gastroduodenal disorders. Study Highlights: 1) WHAT IS KNOWN Chronic gastroduodenal symptoms are common, costly and greatly impact on quality of lifeThere is a poor correlation between gastric emptying testing (GET) and symptomsGastric Alimetry® is a new medical device combining non-invasive gastric electrophysiological mapping and validated symptom profiling 2) WHAT IS NEW HERE Gastric Alimetry generates a 1.5x higher yield for motility abnormalities than GETWith symptom profiling, Gastric Alimetry identified 2.7x more specific patient categories than GETGastric Alimetry improves clinical phenotyping, with improved correlation with symptoms and psychometrics compared to GET.

9.
Neurogastroenterol Motil ; 35(2): e14418, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-35699340

RESUMO

BACKGROUND: Disorders of gastric function are highly prevalent, but diagnosis often remains symptom-based and inconclusive. Body surface gastric mapping is an emerging diagnostic solution, but current approaches lack scalability and are cumbersome and clinically impractical. We present a novel scalable system for non-invasively mapping gastric electrophysiology in high-resolution (HR) at the body surface. METHODS: The system comprises a custom-designed stretchable high-resolution "peel-and-stick" sensor array (8 × 8 pre-gelled Ag/AgCl electrodes at 2 cm spacing; area 225 cm2 ), wearable data logger with custom electronics incorporating bioamplifier chips, accelerometer and Bluetooth synchronized in real-time to an App with cloud connectivity. Automated algorithms filter and extract HR biomarkers including propagation (phase) mapping. The system was tested in a cohort of 24 healthy subjects to define reliability and characterize features of normal gastric activity (30 m fasting, standardized meal, and 4 h postprandial). KEY RESULTS: Gastric mapping was successfully achieved non-invasively in all cases (16 male; 8 female; aged 20-73 years; BMI 24.2 ± 3.5). In all subjects, gastric electrophysiology and meal responses were successfully captured and quantified non-invasively (mean frequency 2.9 ± 0.3 cycles per minute; peak amplitude at mean 60 m postprandially with return to baseline in <4 h). Spatiotemporal mapping showed regular and consistent wave activity of mean direction 182.7° ± 73 (74.7% antegrade, 7.8% retrograde, 17.5% indeterminate). CONCLUSIONS AND INFERENCES: BSGM is a new diagnostic tool for assessing gastric function that is scalable and ready for clinical applications, offering several biomarkers that are improved or new to gastroenterology practice.


Assuntos
Motilidade Gastrointestinal , Estômago , Humanos , Masculino , Feminino , Reprodutibilidade dos Testes , Motilidade Gastrointestinal/fisiologia , Estômago/fisiologia , Eletrodos , Eletrônica
10.
Am J Gastroenterol ; 118(6): 1047-1057, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36534985

RESUMO

INTRODUCTION: Body surface gastric mapping (BSGM) is a new noninvasive test of gastric function. BSGM offers several novel and improved biomarkers of gastric function capable of differentiating patients with overlapping symptom profiles. The aim of this study was to define normative reference intervals for BSGM spectral metrics in a population of healthy controls. METHODS: BSGM was performed in healthy controls using Gastric Alimetry (Alimetry, New Zealand) comprising a stretchable high-resolution array (8 × 8 electrodes; 196 cm 2 ), wearable Reader, and validated symptom-logging App. The evaluation encompassed a fasting baseline (30 minutes), 482 kCal meal, and 4-hour postprandial recording. Normative reference intervals were calculated for BSGM metrics including the Principal Gastric Frequency, Gastric Alimetry Rhythm Index (a measure of the concentration of power in the gastric frequency band over time), body mass index (BMI)-adjusted amplitude (µV), and fed:fasted amplitude ratio. Data were reported as median and reference interval (5th and/or 95th percentiles). RESULTS: A total of 110 subjects (55% female, median age 32 years [interquartile range 24-50], median BMI 23.8 kg/m 2 [interquartile range 21.4-26.9]) were included. The median Principal Gastric Frequency was 3.04 cycles per minute; reference interval: 2.65-3.35 cycles per minute. The median Gastric Alimetry Rhythm Index was 0.50; reference interval: ≥0.25. The median BMI-adjusted amplitude was 37.6 µV; reference interval: 20-70 µV. The median fed:fasted amplitude ratio was 1.85; reference interval ≥1.08. A higher BMI was associated with a shorter meal-response duration ( P = 0.014). DISCUSSION: This study provides normative reference intervals for BSGM spectral data to inform diagnostic interpretations of abnormal gastric function.


Assuntos
Jejum , Estômago , Humanos , Feminino , Adulto , Masculino , Valores de Referência , Estômago/diagnóstico por imagem , Índice de Massa Corporal , Período Pós-Prandial
11.
Sci Transl Med ; 14(663): eabq3544, 2022 Sep 21.
Artigo em Inglês | MEDLINE | ID: mdl-36130019

RESUMO

Chronic nausea and vomiting syndromes (NVSs) are prevalent and debilitating disorders. Putative mechanisms include gastric neuromuscular disease and dysregulation of brain-gut interaction, but clinical tests for objectively defining gastric motor function are lacking. A medical device enabling noninvasive body surface gastric mapping (BSGM) was developed and applied to evaluate NVS pathophysiology. BSGM was performed in 43 patients with NVS and 43 matched controls using Gastric Alimetry (Alimetry), a conformable high-resolution array (8 × 8 electrodes; 20-mm interelectrode spacing), wearable reader, and validated symptom-logging app. Continuous measurement encompassed a fasting baseline (30 minutes), 482-kilocalorie meal, and 4-hour postprandial recording, followed by spectral and spatial biomarker analyses. Meal responses were impaired in NVS, with reduced amplitudes compared to controls (median, 23.3 microvolts versus 38.0 microvolts, P < 0.001), impaired fed-fasting power ratios (1.1 versus 1.6, P = 0.02), and disorganized slow waves (spatial frequency stability, 13.6 versus 49.5; P < 0.001). Two distinct NVS subgroups were evident with indistinguishable symptoms (all P > 0.05). Most patients (62%) had normal BSGM studies with increased psychological comorbidities (43.5% versus 7.7%; P = 0.03) and anxiety scores (median, 16.5 versus 13.0; P = 0.035). A smaller subgroup (31%) had markedly abnormal BSGM, with biomarkers correlating with symptoms (nausea, pain, excessive fullness, early satiety, and bloating; all r > 0.35, P < 0.05). Patients with NVS share overlapping symptoms but comprise distinct underlying phenotypes as revealed by a BSGM device. These phenotypes correlate with symptoms, which should inform clinical management and therapeutic trial design.


Assuntos
Esvaziamento Gástrico , Náusea , Esvaziamento Gástrico/fisiologia , Humanos , Estômago , Síndrome , Vômito
12.
Diagnostics (Basel) ; 12(3)2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35328163

RESUMO

Medical imaging devices often use automated processing that creates and displays a self-normalized image. When improperly executed, normalization can misrepresent information or result in an inaccurate analysis. In the case of diagnostic imaging, a false positive in the absence of disease, or a negative finding when disease is present, can produce a detrimental experience for the patient and diminish their health prospects and prognosis. In many clinical settings, a medical technical specialist is trained to operate an imaging device without sufficient background information or understanding of the fundamental theory and processes involved in image creation and signal processing. Here, we describe a user-friendly image processing algorithm that mitigates user bias and allows for true signal to be distinguished from background. For proof-of-principle, we used antibody-targeted molecular imaging of colorectal cancer (CRC) in a mouse model, expressing human MUC1 at tumor sites. Lesion detection was performed using targeted magnetic resonance imaging (MRI) of hyperpolarized silicon particles. Resulting images containing high background and artifacts were then subjected to individualized image post-processing and comparative analysis. Post-acquisition image processing allowed for co-registration of the targeted silicon signal with the anatomical proton magnetic resonance (MR) image. This new methodology allows users to calibrate a set of images, acquired with MRI, and reliably locate CRC tumors in the lower gastrointestinal tract of living mice. The method is expected to be generally useful for distinguishing true signal from background for other cancer types, improving the reliability of diagnostic MRI.

14.
Neurogastroenterol Motil ; 34(8): e14331, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35156270

RESUMO

BACKGROUND: Functional gastroduodenal disorders include functional dyspepsia, chronic nausea and vomiting syndromes, and gastroparesis. These disorders are common, but their overlapping symptomatology poses challenges to diagnosis, research, and therapy. This study aimed to introduce and validate a standardized patient symptom-logging system and App to aid in the accurate reporting of gastroduodenal symptoms for clinical and research applications. METHODS: The system was implemented in an iOS App including pictographic symptom illustrations, and two validation studies were conducted. To assess convergent and concurrent validity, a diverse cohort with chronic gastroduodenal symptoms undertook App-based symptom logging for 4 h after a test meal. Individual and total post-prandial symptom scores were averaged and correlated against two previously validated instruments: PAGI-SYM (for convergent validity) and PAGI-QOL (for concurrent validity). To assess face and content validity, semi-structured qualitative interviews were conducted with patients. KEY RESULTS: App-based symptom reporting demonstrated robust convergent validity with PAGI-SYM measures of nausea (rS  =0.68), early satiation (rS  =0.55), bloating (rS  =0.48), heartburn (rS  =0.47), upper gut pain (rS  =0.40), and excessive fullness (rS  =0.40); all p < 0.001 (n = 79). The total App-reported Gastric Symptom Burden Score correlated positively with PAGI-SYM (rS  =0.56; convergent validity; p < 0.001), and negatively with PAGI-QOL (rS  = -0.34; concurrent validity; p = 0.002). Interviews demonstrated that the pictograms had adequate face and content validity. CONCLUSIONS AND INFERENCES: The continuous patient symptom-logging App demonstrated robust convergent, concurrent, face, and content validity when used within a 4-h post-prandial test protocol. The App will enable standardized symptom reporting and is anticipated to provide utility in both research and clinical practice.


Assuntos
Duodenopatias , Gastroparesia , Aplicativos Móveis , Esvaziamento Gástrico , Gastroparesia/diagnóstico , Humanos , Náusea , Qualidade de Vida , Índice de Gravidade de Doença , Inquéritos e Questionários
15.
Dig Dis Sci ; 67(3): 773-785, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-33956280

RESUMO

BACKGROUND: Functional nausea and vomiting syndromes and gastroparesis, collectively grouped as nausea and vomiting syndromes (NVS), are overlapping conditions with incompletely understood pathophysiology. Gastric slow wave abnormalities are thought to contribute. AIMS: This study aimed to systematically review and meta-analyze the prevalence of slow wave abnormalities measured by electrogastrography (EGG) in patients with NVS. METHODS: MEDLINE, EMBASE, EMBASE classic, and CENTRAL databases were systematically searched for articles using EGG in adults (≥ 18 years) with NVS. EGG metrics of interest were percentage time in bradygastria, normogastria, and tachygastria as well as dominant frequency and dominant power. Outcomes were also compared with functional dyspepsia (FD), gastroesophageal reflux disease (GORD), and control cohorts. RESULTS: Seven hundred and sixty NVS patients and 308 controls were included from 24 studies. Overall, 64% of patients had EGG abnormalities. Average percent time in normogastria was low during fasting (50%; 95% CI 40-63%) and fed (53%; 95% CI 41-68%) states in patients, with substantial periods in fasting bradygastria (34.1%; 95% CI 25-47%) and postprandial tachygastria (21%; 95% CI 17-26%). Across gastric disorders, pooling of 84 studies showed a comparably high prevalence of EGG abnormalities in NVS (24 studies; n = 760) and GORD (13 studies; n = 427), compared to FD (47 studies; n = 1751) and controls (45 studies; n = 1027). CONCLUSIONS: Frequency-based gastric slow wave abnormalities are prominent in NVS. The strength and consistency of these associations across many studies suggests that gastric dysrhythmia may be an important factor in NVS, motivating the development of more reliable methods for their clinical assessment.


Assuntos
Dispepsia , Gastrite , Refluxo Gastroesofágico , Gastroparesia , Adulto , Esvaziamento Gástrico , Gastroparesia/diagnóstico , Humanos , Náusea , Estômago , Síndrome , Vômito/diagnóstico
16.
Colorectal Dis ; 23(12): 3113-3122, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34714601

RESUMO

AIM: Prolonged postoperative ileus (PPOI) is a common complication following colonic surgery, and is associated with longer hospital stay, greater risk of complications and substantial cost for patients and hospitals. Some reports have recently suggested that gastrointestinal (GI) recovery varies based on the side of resection (i.e., right-sided vs. left-sided colectomy). This systematic review and meta-analysis aimed to compare GI recovery by resection side. METHODS: The MEDLINE, Embase, Cochrane Library and CENTRAL databases were systematically searched for articles reporting GI recovery outcomes in adults undergoing elective right- versus left-sided colectomy (excluding with ileostomy) of any surgical approach. The primary outcome was PPOI, and secondary outcomes included time to first passage of flatus, stool and tolerance of solid diet, and postoperative complications. Subgroup analyses of laparoscopic procedures and cohorts without inflammatory bowel disease and sensitivity analysis of adjusted multivariate results were also performed. RESULTS: Nine studies were identified, of which seven were included in the meta-analysis, comprising 29 068 colectomies (14 581 right-sided; 14 487 left-sided). PPOI was heterogeneously defined and was significantly more likely following right-sided compared to left-sided colectomy regardless of the surgical approach (OR 1.78, 95% CI 1.32-2.39; P < 0.01; I2  = 51%), as well as on subgroup analyses and adjusted multivariate meta-analysis. Secondary outcomes were reported in only a few small studies; hence meta-analysis did not produce reliable results. CONCLUSION: Based on heterogeneous definitions, consistently higher rates of PPOI were observed following right- versus left-sided colectomy. These differences are currently unexplained and highlight the need for further research into the pathophysiology of ileus.


Assuntos
Íleus , Laparoscopia , Adulto , Colectomia/efeitos adversos , Procedimentos Cirúrgicos Eletivos , Humanos , Íleus/epidemiologia , Íleus/etiologia , Laparoscopia/efeitos adversos , Tempo de Internação , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia
17.
Artigo em Inglês | MEDLINE | ID: mdl-33982426

RESUMO

Silicon-based micro and nanoparticles are ideally suited for use as biomedical imaging agents because of their biocompatibility, biodegradability, and simple surface chemistry that facilitates drug loading and targeting. A method to hyperpolarize silicon particles using dynamic nuclear polarization (DNP), which increases magnetic resonance (MR) imaging signals by several orders-of-magnitude through enhanced nuclear spin alignment, was developed to allow silicon particles to function as contrast agents for in vivo magnetic resonance imaging. In this review, we describe the application of the DNP technique to silicon particles and nanoparticles for background-free real-time molecular MR imaging. This review provides a summary of the state-of-the-science in silicon particle hyperpolarization with a detailed protocol for hyperpolarizing silicon particles. This information will foster awareness and spur interest in this emerging area of nanoimaging and provide a path to new developments and discoveries to further advance the field. This article is categorized under: Diagnostic Tools > In Vivo Nanodiagnostics and Imaging Therapeutic Approaches and Drug Discovery > Nanomedicine for Oncologic Disease Therapeutic Approaches and Drug Discovery > Emerging Technologies.


Assuntos
Nanopartículas , Silício , Meios de Contraste , Imageamento por Ressonância Magnética , Nanomedicina
18.
J Pediatr Gastroenterol Nutr ; 73(1): 9-16, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33797449

RESUMO

ABSTRACT: Electrogastrography (EGG) is a non-invasive method of measuring gastric electrophysiology. Abnormal gastric electrophysiology is thought to contribute to disease pathophysiology in patients with gastroduodenal symptoms but this has not been comprehensively quantified in pediatric populations. This study aimed to quantify the abnormalities in gastric electrophysiology on EGG in neonatal and pediatric patients.Databases were systematically searched for articles utilizing EGG in neonatal and pediatric patients (≤18 years). Primary outcomes were prevalence of abnormality, percentage of time in normal rhythm, and power ratio. Secondary outcomes were correlations between patient symptoms and abnormal gastric electrophysiology on EGG.A total of 33 articles (1444 participants) were included. EGG methodologies were variable. Pooled prevalence of abnormalities on EGG ranged from 61% to 86% in patients with functional dyspepsia (FD), gastro-esophageal reflux disease (GERD), and type 1 diabetes mellitus (T1DM). FD patients averaged 20.8% (P = 0.011) less preprandial and 21.6% (P = 0.031) less postprandial time in normogastria compared with controls. Electrophysiological abnormalities were inconsistent in GERD. T1DM patients averaged 46.2% (P = 0.0003) less preprandial and similar (P = 0.32) postprandial time in normogastria compared with controls, and had a lower power ratio (SMD -2.20, 95% confidence interval [CI]: -4.25 to -0.15; P = 0.036). Symptom correlations with gastric electrophysiology were inconsistently reported.Abnormalities in gastric electrophysiology were identifiable across a range of pediatric patients with gastroduodenal symptoms on meta-analysis. However, techniques have been inconsistent, and standardized and more reliable EGG methods are desirable to further define these findings and their potential utility in clinical practice.


Assuntos
Dispepsia , Gastropatias , Criança , Dispepsia/diagnóstico , Esvaziamento Gástrico , Humanos , Recém-Nascido , Período Pós-Prandial , Estômago
19.
Neurogastroenterol Motil ; 33(12): e14151, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33830590

RESUMO

BACKGROUND: Functional dyspepsia (FD) is a common gastroduodenal disorder, yet its pathophysiology remains poorly understood. Bioelectrical gastric slow-wave abnormalities are thought to contribute to its multifactorial pathophysiology. Electrogastrography (EGG) has been used to record gastric electrical activity; however, the clinical associations require further evaluation. AIMS: This study aimed to systematically assess the clinical associations of EGG in FD. METHODS: MEDLINE, EMBASE, and CENTRAL databases were systematically searched for articles using EGG in adults with FD. Primary outcomes were percentage normal versus abnormal rhythm (bradygastria, normogastria, and tachygastria). Secondary outcomes were dominant power, dominant frequency, percentage coupling, and the meal responses. RESULTS: 1751 FD patients and 555 controls from 47 studies were included. FD patients spent less time in normogastria while fasted (SMD -0.74; 95%CI -1.22 to -0.25) and postprandially (-0.86; 95%CI -1.35 to -0.37) compared with controls. FD patients also spent more fasted time in bradygastria (0.63; 95%CI 0.33-0.93) and tachygastria (0.45; 95%CI 0.12-0.78%). The power ratio (-0.17; 95%CI -0.83-0.48) and dominant frequency meal-response ratio (0.06; 95%CI -0.08-0.21) were not significantly different to controls. Correlations between EGG metrics and the presence and timing of FD symptoms were inconsistent. EGG methodologies were diverse and variably applied. CONCLUSION: Abnormal gastric slow-wave rhythms are a consistent abnormality present in FD, as defined by EGG and, therefore, likely play a role in pathophysiology. The aberrant electrophysiology identified in FD warrants further investigation, including into underlying mechanisms, associated spatial patterns, and symptom correlations.


Assuntos
Dispepsia/fisiopatologia , Esvaziamento Gástrico/fisiologia , Gastropatias/fisiopatologia , Estômago/fisiopatologia , Dispepsia/complicações , Eletromiografia , Humanos , Gastropatias/complicações
20.
Esophagus ; 18(3): 425-435, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33594598

RESUMO

BACKGROUND: Gastroesophageal reflux disease (GERD) is a commonly diagnosed gastrointestinal disorder, with a substantial impact on the quality of life. The underlying pathophysiology of GERD is multifactorial and incompletely understood. Abnormal gastric electrical activity, measured using electrogastrography (EGG), may contribute. This study aimed to systematically review and meta-analyse the existing literature in which EGG was used in patients with GERD. METHODS: Databases were systematically searched for studies using EGG in adults with GERD. The primary outcome was the percentage of recording time in the normogastric frequency range. Secondary outcomes were dominant frequency, dominant power, power ratio and prevalence of any EGG abnormality. RESULTS: In total, 591 participants (427 patients with GERD; 164 healthy controls) from 13 studies were included. GERD patients spent 17.3% (SMD - 1.18, 95%CI: - 1.84, - 0.52) and 18.7% (SMD - 1.11, 95%CI: - 1.55, - 0.68) less of the preprandial and postprandial recording time in normogastric frequency ranges, respectively, compared to healthy controls. The dominant frequency, dominant power and power ratio were not significantly different to healthy controls in the preprandial and postprandial periods. The pooled prevalence of any EGG abnormality was significantly greater in patients with GERD than in healthy controls [46% (95%CI: 39-64%) vs. 10% (95%CI: 4-23%); p < 0.0001]. Correlations between GERD symptoms and EGG recordings were inconsistently studied. EGG techniques were heterogeneous. CONCLUSIONS: Consistent abnormalities in gastric slow-wave activity, as measured by EGG, were identified in adults with GERD. Further investigation into these abnormalities using novel emerging electrophysiology techniques is desirable, to better define their contribution toward GERD pathophysiology.


Assuntos
Refluxo Gastroesofágico , Qualidade de Vida , Adulto , Eletromiografia , Refluxo Gastroesofágico/complicações , Humanos , Período Pós-Prandial , Estômago
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA