Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Am J Cardiol ; 214: 1-7, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38110018

RESUMO

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Instrumentos Cirúrgicos , Desenho de Prótese , Fatores de Risco
2.
Circ Cardiovasc Interv ; 16(11): e013238, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37988439

RESUMO

BACKGROUND: Coronary accessibility following redo-transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 (P<0.001). Coronary accessibility improved with a 5-mm Evolut implant depth: 97% at node 4 and 65% at node 5 (P<0.001). When comparing 3- to 5-mm Evolut implant depth, sinus sequestration was the lowest with Sapien-3 outflow at Evolut node 4 (13% versus 2%; P<0.001), and the highest at Evolut node 5 (61% versus 32%; P<0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT02701283.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Tomografia Computadorizada por Raios X , Desenho de Prótese
3.
JTCVS Tech ; 21: 45-55, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37854813

RESUMO

Transaxillary access has been the most frequently used nonfemoral access route for transcatheter aortic valve replacement (TAVR) with a self-expanding valve. Use of transcarotid TAVR is increasing; however, comparative data on these methods are limited. We compared outcomes following transcarotid or transaxillary TAVR with a self-expanding, supra-annular valve. Methods: The Transcatheter Valve Therapy Registry was queried for TAVR procedures using transaxillary and transcarotid access between July 2015 and June 2021. Patients received a self-expanding Evolut R, PRO, or PRO + valve (Medtronic) and had 1-year follow-up. Thirty-day and 1-year outcomes were compared in transcarotid and transaxillary groups after 1:2 propensity score-matching. Multivariable regression models were fitted to identify predictors of key end points. Results: The propensity score-matched cohort included 576 patients receiving transcarotid and 1142 receiving transaxillary access. Median procedure time (99 vs 118 minutes; P < .001) and hospital stay (2 vs 3 days; P < .001) were shorter with transcarotid versus transaxillary access. At 30 days, patients with transcarotid access had similar mortality (Kaplan-Meier estimates 3.7% vs 4.3%, P = .57) but significantly lower stroke (3.1% vs 5.9%; P = .017) and mortality or stroke (6.0% vs 8.9%; P = .033) compared with patients receiving transaxillary access. Similar differences were observed at 1 year. Transaxillary access was associated with increased risk of 30-day stroke (hazard ratio, 2.14; 95% confidence interval, 1.27-3.58) by multivariable regression analysis. Conclusions: Transcarotid versus transaxillary access for TAVR using a self-expanding valve is associated with procedural benefits and significantly lower stroke and mortality or stroke at 30 days. In patients with unsuitable femoral anatomy, transcarotid access may be the preferred delivery route for self-expanding valves.

4.
JACC Cardiovasc Interv ; 15(4): 368-377, 2022 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-35210043

RESUMO

OBJECTIVES: This study sought to determine the degree of Evolut (Medtronic) leaflet pinning, diameter expansion, leaflet overhang, and performance at different implant depths of the balloon-expandable Sapien 3 (S3, Edwards Lifesciences LLC) transcatheter heart valve (THV) within the Evolut THV. BACKGROUND: Preservation of coronary access and flow is a major factor when considering the treatment of failed Evolut THVs. METHODS: An in vitro study was performed with 20-, 23-, 26-, and 29-mm S3 THVs deployed within 23-, 26-, 29-, and 34-mm Evolut R THVs, respectively. The S3 outflow was positioned at various depths at node 4, 5, and 6 of the Evolut R. Neoskirt height, leaflet overhang, performance, and Evolut R valve housing diameter expansion were assessed under physiological conditions as per ISO 5840-3 standard. RESULTS: The neoskirt height for the Evolut R was shorter when the S3 outflow was positioned at node 4 compared with node 6 (node 4 height for 23 mm = 16.3 mm, 26 mm = 17.1 mm, 29 mm = 18.3 mm, and 34 mm = 19.9 mm vs node 6 height for 23 mm = 23.9 mm, 26 mm = 23.4 mm, 29 mm = 24.7 mm, and 34 mm = 27 mm Evolut R). All configurations exhibited acceptable hydrodynamic performance irrespective of the degree of leaflet overhang, except the 29-mm S3 implanted in 34-mm Evolut R at node 4 (regurgitant fraction >20%). The valve housing radius of the index Evolut R increased when the S3 was implanted, with the increase ranging from 0 to 2.5 mm. CONCLUSIONS: Placement of the S3 at a lower implant position within an index Evolut R reduces the neoskirt height with no significant compromise to S3 valve function despite a higher degree of leaflet overhang. Low S3 implantation may facilitate future coronary access after redo transcatheter aortic valve replacement.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Humanos , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Ann Thorac Surg ; 105(2): 484-490, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29174390

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) using a self-expanding valve has been shown to be superior to an open operation in high-risk patients. Extensive iliofemoral peripheral vascular disease can prohibit femoral access. In these cases, direct aortic (DA) implantation may be a suitable option. METHODS: The current analysis compared outcomes in patients undergoing TAVR with the self-expanding CoreValve prosthesis (Medtronic, Minneapolis, MN) by direct aortic (DA) access vs iliofemoral (IF) access. Patients treated in the CoreValve US High Risk and Extreme Risk Pivotal Trials and Continued Access Study were included. Propensity score matching was used to account for differences in baseline characteristics between groups. Clinical outcomes were compared at 30 days and 1 year. RESULTS: We identified 394 matched pairs of IF and DA patients. The all-cause mortality rate was significantly higher in the DA group than in the IF group at 30 days (10.9% vs 4.1%, p < 0.001), but this difference was reduced at 1 year (28.1% vs 23.2%, p = 0.063). All-cause mortality or major stroke was significantly higher for DA vs IF access at 30 days (13.5% vs 5.3%, p < 0.001) and at 1 year (30.4% vs 24.2%, p = 0.025). Major/life-threatening bleeding and acute kidney injury were significantly greater in the DA group at 30 days (66.7% vs 35.4% and 19.7% vs 10.0%, respectively, both p < 0.001). CONCLUSIONS: When femoral access is not feasible, DA access allows effective delivery of the valve but incurs an increased risk of death and adverse events, potentially the result of procedural differences.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Pontuação de Propensão , Substituição da Valva Aórtica Transcateter/métodos , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese , Fatores de Tempo , Resultado do Tratamento
8.
J Am Coll Cardiol ; 66(12): 1327-34, 2015 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-26383718

RESUMO

BACKGROUND: We reported favorable 1-year outcomes in patients unsuitable for surgery who underwent self-expanding transcatheter aortic valve replacement (TAVR) compared with an objective performance goal. Longer-term outcomes in these patients are not known. OBJECTIVES: This study sought to evaluate the 2-year safety and efficacy in patients with severe aortic stenosis (AS) at extreme risk of surgery treated with self-expanding TAVR. METHODS: We performed a prospective, multicenter, controlled, nonrandomized investigation of self-expanding TAVR in patients with severe AS and prohibitive surgical risk. We report the 2-year clinical outcomes in these patients. RESULTS: A total of 489 extreme-risk patients were treated transfemorally with a self-expanding aortic bioprosthesis at 41 centers. The rate of all-cause mortality or major stroke was 38.0% at 2 years (all-cause mortality, 36.5%; major stroke, 5.1%). The rates of all-cause mortality, cardiovascular mortality, and major stroke were 36.6%, 26.2%, and 5.1%, respectively, at 2 years. Between 1 and 2 years, the incremental all-cause mortality, cardiovascular mortality, and major stroke rates were 12.3%, 7.9%, and 0.8%, respectively. Multivariable predictors of all-cause mortality at 2 years included the presence of coronary artery disease and admission from an assisted living center. A Society of Thoracic Surgeons score >15% was also predictive of 2-year all-cause mortality. At 2 years, 94% of patients had New York Heart Association functional class I or II symptoms. The frequency of moderate or severe paravalvular regurgitation (4.3% at 1 year; 4.4% at 2 years) was unchanged between the first and second year. CONCLUSIONS: Patients with severe AS at extreme surgical risk treated with self-expanding TAVR continued to show good clinical outcomes and hemodynamic valve performance at 2 years. The presence of comorbid conditions rather than valve performance affected 2-year outcomes in these patients. (Safety and Efficacy Study of the Medtronic CoreValve System in the Treatment of Symptomatic Severe Aortic Stenosis in High Risk and Very High Risk Subjects Who Need Aortic Valve Replacement; NCT01240902).


Assuntos
Estenose da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Estados Unidos/epidemiologia
9.
J Thorac Cardiovasc Surg ; 138(1): 125-32, 2009 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19577069

RESUMO

OBJECTIVE: During coronary surgery, proximal vein graft anastomoses have been performed by using an aortic partial occlusion clamp to allow for a hand-sewn anastomosis. The purpose of this multicenter, prospective, randomized trial was to evaluate the efficacy of the PAS-Port device (Cardica, Inc, Redwood City, Calif), which allows an automated proximal anastomosis to be performed without aortic clamping. METHODS: Between June 22, 2006, and March 22, 2007, 220 patients requiring coronary artery bypass grafting with at least 2 vein grafts were enrolled. Within each patient, 1 graft was randomly assigned to receive a PAS-Port device, and the other was assigned to receive a hand-sewn anastomosis to the ascending aorta. The primary end point was angiographic patency (<50% stenosis) 9 months after surgical intervention. Secondary end points included average time to complete each anastomosis and 9-month freedom from major adverse cardiac events. RESULTS: One hundred eighty-three patients received matched grafts that were angiographically assessed at 9 months. The 9-month graft patency was 82.0% (150/183) for hand-sewn and 80.3% (147/183) for PAS-Port grafts. The patency rate of PAS-Port anastomoses was statistically noninferior to that of hand-sewn anastomoses (95% lower confidence limit for difference, -7.95%). The freedom from major adverse cardiac events at 9 months was 97.7% for PAS-Port (95% confidence interval, 94.5%-99.0%) and 98.2% for hand-sewn (95% confidence interval, 95.1%-99.3%) grafts. The PAS-port device was associated with a 4.6 +/- 3.9-minute reduction in anastomotic time compared with that seen with a hand-sewn anastomosis (P < .001). CONCLUSIONS: The PAS-Port proximal anastomotic device produces an effective anastomosis with a 9-month patency rate that is comparable with that of a hand-sewn anastomosis. It allows for construction of a proximal anastomosis without aortic clamping and requires less time than a hand-sewn anastomosis.


Assuntos
Anastomose Cirúrgica/instrumentação , Ponte de Artéria Coronária/instrumentação , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica/efeitos adversos , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida , Grau de Desobstrução Vascular
10.
Virology ; 346(1): 151-68, 2006 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-16325880

RESUMO

While DNA vaccines have been shown to prime cellular immune responses, levels are often low in nonhuman primates or humans. Hence, efforts have been directed toward boosting responses by combining DNA with different vaccination modalities. To this end, a polyvalent DNA prime/protein boost vaccine, consisting of codon optimized HIV-1 env (A, B, C, E) and gag (C) and homologous gp120 proteins in QS-21, was evaluated in rhesus macaques and BALB/c mice. Humoral and cellular responses, detected following DNA immunization, were increased following protein boost in macaques and mice. In dissecting cellular immune responses in mice, protein-enhanced responses were found to be mediated by CD4+ and CD8+ T cells with a Th1 cytokine bias. Our study reveals that, in addition to augmenting humoral responses, protein boosting of DNA-primed animals augments cellular immune responses mediated by CD8+ CTL, CD4+ T-helper cells and Th1 cytokines; thus, offering much promise in controlling HIV-1 in vaccinees.


Assuntos
Vacinas contra a AIDS/administração & dosagem , Vacinas contra a AIDS/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Imunização Secundária/métodos , Vacinas de DNA/administração & dosagem , Vacinas de DNA/imunologia , Vacinas contra a AIDS/genética , Animais , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/imunologia , Citocinas/metabolismo , Produtos do Gene env/genética , Produtos do Gene env/imunologia , Produtos do Gene gag/genética , Produtos do Gene gag/imunologia , Anticorpos Anti-HIV/sangue , Humanos , Imunidade Celular , Imunização , Esquemas de Imunização , Macaca mulatta , Camundongos , Camundongos Endogâmicos BALB C , Células Th1/imunologia
11.
Ann Thorac Surg ; 80(5): 1706-11, 2005 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-16242443

RESUMO

BACKGROUND: Functional ischemic mitral regurgitation (MR) frequently arises after myocardial infarction; it is characterized by annular enlargement or lateral displacement of the subvalvular apparatus. Coapsys is a ventricular-annular remodeling device designed to treat functional ischemic MR; it does not require cardiopulmonary bypass. Initial intraoperative results of the RESTOR-MV randomized clinical trial are presented. METHODS: Patients referred for coronary artery bypass grafting with preoperative MR grade of 2 or greater were studied, excluding those with structural valve abnormalities. The Coapsys device, which consists of two epicardial pads connected by a flexible cord, was surgically implanted in 19 patients. Under epicardial echocardiographic guidance, the cord was passed through the left ventricle and tightened externally to improve leaflet coaptation and stabilize the ventricular wall; tightening was conducted with color flow Doppler imaging. RESULTS: Patients were 64.5 +/- 9.2 years old with an ejection fraction of 0.383 +/- 0.089 and received 2.7 +/- 1.1 grafts. Intraoperative MR grade was 2.7 +/- 0.8 after induction and was reduced to 0.4 +/- 0.7 after implantation (p < 0.0001). Mean epicardial dimension was reduced from 8.5 +/- 1.2 to 6.4 +/- 0.9 cm (p < 0.0001). Intraoperative MR was reduced in 95% (18 of 19) of patients, and 84% (16 of 19) had MR grade 1 or less after implantation. All implants were performed without cardiopulmonary bypass or conversion to standard annuloplasty. No hemodynamic compromise or structural damage to the mitral apparatus was noted. Significant acute remodeling was noted in the left ventricular dimensions. CONCLUSIONS: In patients without structural valve disease, the Coapsys device acutely reduces functional MR. Further randomized evaluation will assess long-term stability and compare it with standard annuloplasty techniques.


Assuntos
Desenho de Equipamento/instrumentação , Período Intraoperatório , Insuficiência da Valva Mitral/cirurgia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência da Valva Mitral/etiologia , Estudos Multicêntricos como Assunto , Ensaios Clínicos Controlados Aleatórios como Assunto
12.
J Thorac Cardiovasc Surg ; 126(1): 168-77; discussion 177-8, 2003 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-12878952

RESUMO

OBJECTIVES: To evaluate the safety and effectiveness of a self-closing surgical clip with an interrupted technique in left internal thoracic artery to left anterior descending artery bypass grafting. METHODS: Eighty-two patients were enrolled and treated (February 2000 through August 2001) in a prospective, nonrandomized, multicenter trial. Left internal thoracic artery to left anterior descending artery anastomoses were performed in 60 off-pump coronary artery bypasses (73%), 12 conventional coronary artery bypass grafting (15%), and 10 minimally invasive direct coronary artery bypass (12%) procedures. Angiograms (64 to 383 days, mean 200 days) were obtained on 63 patients (77%). Qualitative and quantitative angiographic assessment was performed by an independent core laboratory. RESULTS: The self-closing surgical clip was used for 82 left internal thoracic artery to left anterior descending artery interrupted anastomoses without the requirement for knot tying or primary suture management. Minimum left internal thoracic artery to left anterior descending artery anastomosis time was 3 minutes. There was one perioperative and one late death (both not heart related) and one reexploration for bleeding unrelated to the anastomotic site. FitzGibbon grades were as follows: A (n = 60, 95.2%), B (n = 3, 4.8%) including one kinked left internal thoracic artery, and O (n = 0, 0%). Quantitative analysis (n = 57) showed mean lumen diameters of left internal thoracic artery proximal to the anastomosis of 2.1 mm, at anastomosis of 2.0 mm, and in the left anterior descending artery distal to the anastomosis of 1.9 mm. The average ratio of the anastomosis to the left anterior descending artery diameter was 1.14 (0.45 to 1.93). Anastomotic stenosis as a percentage of average left internal thoracic artery to left anterior descending artery diameter was -2.3%, comparing favorably with results (23% to 24%) reported from the Patency, Outcomes, Economics, Minimally invasive direct coronary artery (POEM) bypass study. CONCLUSIONS: The interrupted technique, facilitated by a self-closing anastomotic clip, yields favorable 6-month angiographic results when compared with other published studies.


Assuntos
Angiografia Coronária , Ponte de Artéria Coronária/instrumentação , Vasos Coronários/cirurgia , Instrumentos Cirúrgicos , Adulto , Idoso , Idoso de 80 Anos ou mais , Anastomose Cirúrgica , Velocidade do Fluxo Sanguíneo/fisiologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/fisiopatologia , Doença da Artéria Coronariana/cirurgia , Vasos Coronários/fisiopatologia , Segurança de Equipamentos/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Grau de Desobstrução Vascular/fisiologia
13.
Heart Surg Forum ; 5(4): 319-26; discussion 327, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12538111

RESUMO

BACKGROUND: Interrupted suture technique avoids the "purse string" and puckering effects frequently seen with continuous suture techniques and should represent the standard of care in the creation of high-quality vascular anastomoses. This clinical study evaluated the safety and effectiveness of a self-closing surgical clip (Coalescent Surgical U-CLIP Anastomotic Device [U-CLIP]) designed to facilitate this interrupted technique. Left internal mammary artery (LIMA) to left anterior descending (LAD) coronary bypass grafting was studied. METHODS: Eighteen patients meeting inclusion criteria were enrolled (October 2000 through September 2001) into this prospective study. Anastomoses were performed using a beating-heart median sternotomy procedure (off-pump coronary artery bypass) in 17 cases (94%) and a minimally invasive beating-heart procedure (minimally invasive direct coronary artery bypass [MIDCAB]) in one case (6%). Six-month follow-up was completed on 18 patients (100%), with angiograms performed on 17 patients (94%) at a mean of 179 days (range, 168-191 days). Qualitative and quantitative angiographic assessment was performed by an independent core laboratory. RESULTS: The U-CLIP was used for 18 LIMA-to-LAD interrupted anastomoses without the requirement for knot tying or suture management and with no device-related morbidity or mortality. Mean LIMA-to-LAD anastomosis time was 8.6 minutes (range, 5-14 minutes). All anastomoses were FitzGibbon grade A at 6 months postprocedure. Quantitative analysis showed mean luminal diameters proximal to the anastomosis of 2.32 mm, at the anastomosis of 2.25 mm, and immediately distal to anastomosis of 1.99 mm. The average ratio of anastomosis to LAD diameter was 1.17 (range, 0.93- 1.93). Anastomotic stenosis as a percentage of average LIMA/LAD diameter was a negative 4.2%, comparing favorably with the 23% to 24% reported in the POEM (Patency, Outcomes, Economics of MIDCAB) study. CONCLUSIONS: The interrupted technique, facilitated by a self-closing anastomotic clip, yielded 6-month follow-up and angiographic results that compared favorably with results of other published studies.


Assuntos
Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/instrumentação , Prótese Vascular/efeitos adversos , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/instrumentação , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Instrumentos Cirúrgicos/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/fisiopatologia , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA