Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
JACC Clin Electrophysiol ; 9(6): 836-847, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36752462

RESUMO

BACKGROUND: Multicenter ventricular tachycardia (VT) ablation studies have shown poorer outcomes compared with single-center experiences. This difference could be related to heterogeneous mapping and ablation strategies. OBJECTIVES: This study evaluated a homogenous simplified catheter ablation strategy for different substrates and compared the results with those of a single referral center. METHODS: This was a multicenter prospective VT ablation registry of patients with the following 4 causes of VT: previous myocardial infarction; previous myocarditis; arrhythmogenic right ventricular dysplasia; or idiopathic dilated cardiomyopathy. The procedural protocol included precise mapping and ablation steps with the combined endpoint of late potential (LP) abolition and noninducibility of VT. The long-term primary efficacy endpoint was freedom from VT. RESULTS: A total of 309 patients were enrolled. LPs were present in 70% of patients and were abolished in 83%. At the end of the procedure 74% of LPs were noninducible. The primary combined endpoint of LP abolition and noninducibility was achieved in 64% of patients with LPs at baseline. Freedom from VT at 12 months was observed in 67% of patients. In the overall study group, VT inducibility was the only predictor of freedom from VT (P = 0.013). In patients with LPs, the VT recurrence rate was lower both for patients with complete LP abolition (P = 0.040) and for patients meeting the composite endpoint (P = 0.035). CONCLUSIONS: A standardized VT mapping and ablation technique reproduced the procedural outcomes of a single referral center in a multicenter prospective study. LP abolition and noninducibility were effective in reducing VT recurrences in patients with 4 causes of cardiomyopathy. (Ventricular Tachycardia Ablation Registry; NCT03649022).


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Estudos Prospectivos , Resultado do Tratamento , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/cirurgia , Taquicardia Ventricular/etiologia , Lipopolissacarídeos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
2.
Minerva Cardiol Angiol ; 71(1): 91-99, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35080355

RESUMO

BACKGROUND: Catheter ablation (CA) of atrial fibrillation (AF) is used routinely to establish rhythm control. There is mounting evidence that CA procedures should be performed during continuous oral anticoagulation and direct oral anticoagulants (DOACs) are considered the first anticoagulation strategy. Few real-life data are now available and even less in the Italian panorama. METHODS: IRIS is an Italian multicenter, non-interventional, prospective study which will be enrolled consecutive AF patients eligible for CA and treated with Rivaroxaban; patients in treatment with Rivaroxaban proceeded directly to CA while Rivaroxaban-naive patients were scheduled for CA after 4 weeks of uninterrupted anticoagulation unless the exclusion of atrial thrombi. Rivaroxaban was uninterrupted or shortly uninterrupted (<24 hours) prior CA, in line with routinely practice of each operator. Patients will be followed on continuous anticoagulation for 1 month after the ablation. The primary efficacy outcome is the cumulative incidence of all-cause death and systemic embolism while the primary safety outcome is the incidence of major bleeding events. The secondary outcomes are represented by non-major bleeding events. All events must be occurred within the first 30 days after the procedure. RESULTS: Two hundred fifty patients are expected to be enrolled and the study is estimated to be completed by the end of 2022. Up to now 56 patients have been enrolled. CONCLUSIONS: This study is the first large Italian prospective study on the management of Rivaroxaban in patients undergoing CA of AF. It aims to depict a comprehensive view of anticoagulation strategy prior CA in several Italian electrophysiology labs.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Rivaroxabana/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Inibidores do Fator Xa/efeitos adversos , Resultado do Tratamento , Hemorragia/induzido quimicamente , Hemorragia/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Sistema de Registros
4.
Heart Rhythm ; 18(8): 1292-1300, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33838316

RESUMO

BACKGROUND: Sporadic high impedance values without other anomalies detected by remote monitoring of hybrid cardiac implantable electronic device systems have been described recently. The clinical significance and related hazard of this phenomenon are not fully understood. OBJECTIVE: The purpose of this study was to describe the prevalence, management, and outcomes associated with hybrid implantable cardioverter-defibrillator (ICD) systems. METHODS: We collected data on patients with sporadic high lead impedance alert on remote monitoring who had undergone implantation with a hybrid ICD system between January 2015 and December 2019. Pacing thresholds, sensing and impedance values, and temporal pattern of impedance values were collected by remote monitoring, at implantation, and during an in-office visit. RESULTS: Among 92 patients receiving a hybrid ICD, 15 (16.3%) had high impedance alert on remote monitoring (14 Boston Scientific and 1 St. Jude Medical ICD canisters paired with Medtronic or Biotronik DF-1 leads). Four patients had a cardiac resynchronization therapy-defibrillator (CRT-D), 7 a dual-chamber ICD, and 4 a single-chamber ICD. Three patients presented with high atrial lead impedance, 7 high right ventricular lead impedance, 1 high left ventricular impedance, and 2 high shock impedance values. All patients underwent follow-up by remote monitoring. Sporadic high impedance values were not associated with an adverse outcome or need for revision in all but 1 patient, who had continuously increasing pacing thresholds due to lead microfracture. CONCLUSION: In the absence of clear signs of lead fracture or connection issues, sporadic high pacing and shock impedance in hybrid implantable defibrillator systems can be safely managed by close follow-up.


Assuntos
Arritmias Cardíacas/terapia , Terapia de Ressincronização Cardíaca/métodos , Desfibriladores Implantáveis , Monitorização Fisiológica/métodos , Telemedicina/métodos , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Impedância Elétrica , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
5.
J Cardiovasc Electrophysiol ; 31(7): 1694-1701, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-32369225

RESUMO

BACKGROUND: Ablation index (AI) is a new lesion quality marker that has been demonstrated to allow a high single-procedure arrhythmia-free survival in single-center studies. This prospective, multi-center study was designed to evaluate the reproducibility of pulmonary vein (PV) isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV isolation and were divided in four study groups according to operator's preference in choosing the ablation catheter (a contact force (ST) or contact force surround flow (STSF) catheter) and the AI setting (330-450 or 380-500 at anterior wall or posterior wall, respectively). RESULTS: At 12 months a high rate of freedom from AF recurrences was observed in patients with both paroxysmal and persistent AF (91% vs 83.3%; P = .039). There was no difference in the rate of AF recurrence among the four study groups (4.5% in group ST330-450, 12.2% in group ST 380-500, 14.9% in group STSF330-450, 9.4% in group STSF380-500; P = .083). Recurrence was also similar between patients treated with a ST (8%) or STSF catheter (12.1%; P = .2), and within patients targeting an AI settings of 330 to 450 (10.9%) or 380 to 500 (10.3%; P = .64). In patients with paroxysmal AF, there was no difference (P = .12) in the 1-year freedom from AF recurrence among 14 operators that performed ≥10 ablation procedure. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion resulted in high rate of 1-year freedom from AF recurrence, irrespective of the ablation catheters, AI settings, and operator.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Reprodutibilidade dos Testes , Resultado do Tratamento
6.
Pacing Clin Electrophysiol ; 42(7): 874-881, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31045257

RESUMO

BACKGROUND: Atrial fibrillation (AF) ablation outcome is still operator dependent. Ablation Index (AI) is a new lesion quality marker that has been demonstrated to allow acute durable pulmonary vein (PV) isolation followed by a high single-procedure arrhythmia-free survival. This prospective, multicenter study was designed to evaluate the reproducibility of acute PV isolation guided by the AI. METHODS: A total of 490 consecutive patients with paroxysmal (80.4%) and persistent AF underwent first time PV encircling and were divided in four study groups according to operator preference in choosing the ablation catheter (a contact force [ST] or contact force surround flow [STSF] catheter) and the AI setting (330 at posterior and 450 at anterior wall or 380 at posterior and 500 at anterior wall). Radiofrequency was delivered targeting interlesion distance ≤6 mm. RESULTS: The rate of first-pass PV isolation (ST330 90 ± 16%, ST380 87 ± 19%, STSF330 90 ± 17%, STSF380 91 ± 15%, P = .585) was similar among the four study groups, whereas procedure (ST330 129 ± 44 minutes, ST380 144 ± 44 minutes, STSF330 120 ± 72 minutes, STSF380 125 ± 73 minutes, P < .001) and fluoroscopy time (ST330 542 ± 285 seconds, ST380 540 ± 416 seconds, STSF330 257 ± 356 seconds, STSF380 379 ± 454 seconds, P < 0.001) significantly differed. The difference in the rate of first-pass isolation was not statistical different (P = .06) among the 12 operators that performed at least 15 procedures. CONCLUSIONS: An ablation protocol respecting strict criteria for contiguity and quality lesion results in high and comparable rate of acute PV isolation among operator performing ablation with different catheters, AI settings, procedure, and fluoroscopy times.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Sistema de Registros , Reprodutibilidade dos Testes
7.
Circ J ; 82(4): 974-982, 2018 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-29415917

RESUMO

BACKGROUND: Our aim was to evaluate the clinical outcome of paroxysmal atrial fibrillation (AF) ablation with contact force technology, using an automated lesion tagging system (VISITAGTM module) with strict criteria of catheter stability.Methods and Results:We enrolled 200 consecutive patients who underwent pulmonary vein isolation (PVI) in 11 centers and were followed up for 12 months. The stability setting was within 3 mm for ≥10 s and for ≥15 s in 47% and 53% of patients, respectively. A mean of 67.2±21.9 VISITAGs was acquired. Freedom from atrial tachyarrhythmias at follow-up was 77.5% (155/200), and the contiguity between lesions was associated with a higher chronic success rate (96% vs. 77.1%; log-rank P=0.036). Radiofrequency (RF), fluoroscopy times, and recurrence rates at the 12-month follow-up were significantly lower than in a comparison group of 80 patients without VISITAGTM module (42.7±14.5 vs. 50.9±23.6 min; P=0.032; 11.6±7.8 vs. 18.4±12.8 min; P=0.003 and 22.5% vs. 41.2%; P=0.02). Two major complications (1 cardiac tamponade and 1 minor stroke) were observed only in the control group. CONCLUSIONS: Paroxysmal AF ablation with contact force technology and strict criteria of stability using the VISITAG module was a safe procedure, associated with an improvement in efficiency and a reduction of atrial tachyarrhythmia recurrence at the 12-month follow-up compared with manual annotation. Contiguity between lesions seemed to enhance effectiveness outcomes.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter/métodos , Veias Pulmonares/fisiopatologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Casos e Controles , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Taquicardia/patologia , Taquicardia/prevenção & controle , Resultado do Tratamento , Adulto Jovem
8.
J Cardiovasc Echogr ; 25(1): 26-28, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-28465924

RESUMO

A 55-year-old man complaining of worsening dyspnea on exertion was diagnosed with restrictive interventricular septal defect, left ventricular noncompaction (LVNC), mild aortic valve stenosis and aorto-right ventricular fistula. He underwent surgical aortic valve replacement with a mechanical bileaflet valve (St. Jude n. 23) and contextual direct suture of interventricular septal defect and closure of aorto-right ventricular fistula. At 2 years of follow-up, the patient was in good general condition. A complete echocardiographic examination showed normalization of left ventricular dimensions and ejection fraction. Furthermore, left ventricular trabeculations became less evident and no longer met the diagnostic criteria for noncompaction. In our case, the expected left ventricular reverse remodeling after cardiac surgery was associated with a significant reduction in LVNC features. In conclusion, physicians should be careful in avoiding overdiagnosis of LVNC, whose features may indeed reflect only the hypertrabeculated morphology of a normal or pathological heart.

9.
J Interv Card Electrophysiol ; 42(1): 21-6, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25378035

RESUMO

PURPOSE: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicenter prospective study, we assessed the relationship between catheter contact force (CF) during RFCA for paroxysmal atrial fibrillation (AF) and clinical recurrences over a mid-term follow-up. METHODS: All patients underwent RFCA for paroxysmal AF by antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. A new open-irrigated tip catheter with CF sensing (SmartTouch(TM), Biosense Webster Inc. CA) was used. All patients were followed for at least 12 months and the relationship between CF and clinical outcomes assessed. RESULTS: One year follow-up was available in 92/95 of the patients enrolled. Acute PV isolation was achieved in 100 % of the veins. Mean CF during RFCA was 12.2 ± 3.9 g. Mean force-time integral (FTI) was 733 ± 505 gs. Following the 3-month blanking period, 17 (18 %) patients experienced at least 1 atrial tachyarrhythmia relapse. There was no statistical difference in mean CF (13 ± 3.4 g vs 12 ± 4 g, p = 0.32) and mean FTI (713 ± 487 gs vs 822 ± 590 gs, p = 0.42) between patients with and without arrhythmia recurrences. Recurrences were recorded in 22 % of patients achieving a mean FTI value below the median of 544 gs and in 15 % of patients with a mean FTI value above the median (p = 0.64). CONCLUSIONS: RFCA with CF data during PV isolation for paroxysmal AF improves physician's knowledge on catheter-tissue contact. In the present dataset, however, higher CF values did not impact mid-term clinical RFCA outcome.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Sistema de Condução Cardíaco/cirurgia , Veias Pulmonares/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/prevenção & controle , Desenho de Equipamento , Análise de Falha de Equipamento , Seguimentos , Humanos , Itália , Estudos Longitudinais , Pessoa de Meia-Idade , Recidiva , Estresse Mecânico , Resultado do Tratamento
11.
Europace ; 16(3): 335-40, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24337158

RESUMO

AIMS: Catheter-tissue contact is critical for effective lesion creation in radiofrequency catheter ablation (RFCA). In a multicentre prospective study, we assessed the effect of direct contact force (CF) measurement on acute procedural parameters during RFCA of atrial fibrillation (AF). METHODS AND RESULTS: A new open-irrigated tip catheter with CF sensing (SmartTouch™, Biosense Webster Inc.) was used. All the patients underwent the first ablation procedure for paroxysmal AF with antral pulmonary vein (PV) isolation, aiming at entry and exit conduction block in all PVs. Ninety-five patients were enroled in nine centres and successfully underwent ablation. Overall procedure time, fluoroscopy time, and ablation time were 138.0 ± 67.0, 14.3 ± 11.2, and 33.8 ± 19.4 min, respectively. The mean CF value during ablation was 12.2 ± 3.9 g. Force time integral (FTI) analysis showed that patients achieving a value below the median of 543.0gs required longer procedural (158.0 ± 74.0 vs. 117.0 ± 52.0 min, P = 0.004) and fluoroscopy (17.5 ± 13.0 vs. 11.0 ± 7.7 min, P = 0.007) times as compared with those in whom FTI was above this value. Patients in whom the mean CF during ablation was >20 g required shorter procedural time (92.0 ± 23.0 vs. 160.0 ± 67.0 min, P = 0.01) as compared with patients in whom this value was <10 g. Four groin haematomas were the only complications observed. CONCLUSION: Contact force during RFCA for PV isolation affects procedural parameters, in particular procedural and fluoroscopy times, without increasing complications.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Fluoroscopia , Sistema de Condução Cardíaco/cirurgia , Duração da Cirurgia , Veias Pulmonares/cirurgia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Ablação por Cateter/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estresse Mecânico , Tato , Transdutores , Resultado do Tratamento , Adulto Jovem
12.
Eur Heart J ; 33(11): 1344-50, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22285581

RESUMO

AIMS: Patients at risk of sudden cardiac death (SCD) after myocardial infarction (MI) can be offered therapy with implantable cardioverter defibrillators (ICDs). Whether plasma biomarkers can help risk stratify for SCD and ventricular arrhythmias (VT/VF) is unclear. METHODS AND RESULTS: The primary objective of the CAMI-GUIDE study is to assess the predictive role of C-reactive protein for SCD or VT/VF in ischaemic patients with the ejection fraction <30% and ICDs. Secondary endpoints included all-cause mortality, hospitalizations, and death from heart failure. Additional analyses incorporated cystatin-C and NT-ProBNP in multi-marker approach for the prediction of adverse outcomes. A total of 300 patients were enrolled. All-cause mortality at 2 years was 22.6%, mortality from heart failure was 8.3%. Primary endpoint occurred in 17.3%. At a competing risk multivariable analysis adjusted for baseline variables, no significant difference in primary endpoint was found between patients with C-reactive protein ≤3 vs. >3 mg/L [heart rate (HR) 0.91 (0.50-1.64) P = 0.76], while C-reactive protein >3 mg/L was strongly associated with mortality due to heart failure [HR: 3.17 (1.54-6.54) P = 0.002]. NT-proBNP above median was significantly associated with the primary endpoint [adjusted HR: 1.46 (1.020-2.129) P = 0.042]. A risk function, including the three biomarkers, NYHA class and resting HR, allowed stratification of patient mortality risk from 5 to 50%. CONCLUSION: C-reactive protein >3 mg/L is not associated with SCD or fast VT/VF, however, is a strong predictor of HF mortality. Biomarkers combined with clinical markers allow an excellent risk stratification of mortality at 2 years.


Assuntos
Proteína C-Reativa/metabolismo , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Infarto do Miocárdio/sangue , Taquicardia Ventricular/terapia , Idoso , Biomarcadores/metabolismo , Métodos Epidemiológicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Taquicardia Ventricular/sangue , Taquicardia Ventricular/mortalidade
14.
J Cardiovasc Med (Hagerstown) ; 8(4): 293-9, 2007 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-17413310

RESUMO

BACKGROUND: Patients at risk of sudden cardiac death (SCD) after myocardial infarction (MI) can currently be offered effective means of prevention, such as implantable cardioverter-defibrillators (ICD). However, predictors of SCD able to identify those patients who are at higher risk are still lacking. Whether C-reactive protein (CRP), a serum inflammatory marker with established prognostic accuracy after MI, can also be a predictor of SCD is unclear. METHODS: The CAMI GUIDE study is designed to evaluate the prognostic role of CRP in patients undergoing ICD implantation after MI according to MADIT II criteria (i.e. left ventricular ejection fraction

Assuntos
Proteína C-Reativa/metabolismo , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Infarto do Miocárdio/terapia , Biomarcadores/sangue , Estudos de Coortes , Interpretação Estatística de Dados , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Seguimentos , Humanos , Itália/epidemiologia , Infarto do Miocárdio/sangue , Infarto do Miocárdio/complicações , Infarto do Miocárdio/mortalidade , Seleção de Pacientes , Valor Preditivo dos Testes , Prognóstico , Estudos Prospectivos , Projetos de Pesquisa , Medição de Risco , Fatores de Risco , Tamanho da Amostra , Taquicardia Ventricular/sangue , Taquicardia Ventricular/prevenção & controle , Resultado do Tratamento , Fibrilação Ventricular/sangue , Fibrilação Ventricular/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA