Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
J Laryngol Otol ; 137(2): 158-162, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35027097

RESUMO

OBJECTIVE: To evaluate patients' hearing outcomes after ossicular chain reconstruction using unmodified autologous incus. METHODS: A single-centred, retrospective study of patients who underwent incus interposition between June 2010 and October 2017 was conducted at a Dutch secondary referral centre. This paper describes a chart review of patients who presented with erosion of the long process of the incus due to atelectasis or cholesteatoma who were treated with an unmodified incus interposition. The main outcome measures were: post-operative air-bone gap and level of air-bone gap closure. RESULTS: Thirty-three ears of 32 patients were included. Follow-up duration ranged from six weeks to seven years. A mean post-operative air-bone gap under 25 dB was considered successful; this was achieved in 25 patients (76 per cent), 20 (91 per cent) in the partial ossicular reconstruction prosthesis group and 5 (45 per cent) in the total ossicular reconstruction prosthesis group. This difference was statistically significant (p = 0.007). CONCLUSION: Successful preservation and improvement of hearing was observed in most patients. As expected, the closure rate in the partial ossicular reconstruction prosthesis group was better. Longer follow-up studies with larger case numbers are needed to assess whether further reconstruction techniques are necessary.


Assuntos
Prótese Ossicular , Substituição Ossicular , Humanos , Bigorna/cirurgia , Estudos Retrospectivos , Análise Custo-Benefício , Resultado do Tratamento , Timpanoplastia/métodos , Substituição Ossicular/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA