Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Arch Bronconeumol ; 52(1): 5-11, 2016 Jan.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-26071369

RESUMO

INTRODUCTION: Sedation during endobronchial ultrasound (EBUS) is essential due to the long duration of this procedure. We evaluated different models of sedation and their complications. METHOD: A multicenter, prospective, observational study of 307 patients undergoing EBUS was conducted. Patients were sedated with: a) midazolam bolus; b) propofol infusion; c) midazolam bolus and propofol infusion; d) propofol infusion and remifentanil infusión, or e) midazolam bolus and fentanyl bolus, and clinical variables were collected. Patients were asked to complete a satisfaction survey following the test. RESULTS: Patients per sedation model were: A 24, B 37, C 107, D 62 and E 77. Scores for perceived sensations of recall, pain, cough, dyspnea and prolonged examination (0.65±1.11; 0 3±0.73, 0.46±0.9, 0.29±0.73, and 0.59±0.96, respectively) were lower compared to fear and nervousness before the examination (1.26±1.37 and 1.5±1.41, respectively). High levels of indifference to repeating the procedure (1.49±1.3) and a reported pleasant feeling during the test (1.23±1.17), with low levels of anxiety (0.49±0.85) and discomfort (0.62±1.1), show that different models of sedation were well tolerated. Almost half the patients (46.6%) did not report any "worst moment" during the procedure, and 89.6% were willing to undergo a repeat test. The E and C models presented fewest complications (12.9 and 31.7%, respectively), and all were resolved with simple therapeutic measures. CONCLUSIONS: The models of sedation evaluated were well tolerated and most patients were willing to undergo repeat EBUS. Complications were few and easily resolved.


Assuntos
Broncoscopia , Sedação Consciente , Sedação Profunda , Endossonografia , Adulto , Idoso , Idoso de 80 Anos ou mais , Broncoscopia/efeitos adversos , Sedação Consciente/efeitos adversos , Sedação Profunda/efeitos adversos , Feminino , Humanos , Hipnóticos e Sedativos/uso terapêutico , Masculino , Pessoa de Meia-Idade , Modelos Teóricos , Satisfação do Paciente , Estudos Prospectivos
2.
Arch Bronconeumol ; 51(2): e8-e11, 2015 Feb.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-25443586

RESUMO

Real-time elastography performed during endoscopic ultrasonography is a relatively new method for characterizing tissue stiffness, and has been used successfully as a predictor of malignancy in mediastinal lymph nodes. This case report describes our practical experience with this technique using an ultrasound bronchoscope to examine mediastinal lymph nodes. We present a case of sectorial endobronchial ultrasound and the first published case of endoscopic ultrasound elastography using ultrasound bronchoscope in two patients with non-small cell lung carcinoma. Qualitative tissue color pattern was obtained in both cases and correlated with pathological evaluation. The initial feasibility results are promising and suggest that ultrasound bronchoscopy techniques, such as guided nodal staging, merit additional studies. It may be important to categorize the risk of malignancy to facilitate sampling decisions.


Assuntos
Broncoscopia/métodos , Carcinoma Pulmonar de Células não Pequenas/secundário , Carcinoma de Células Escamosas/secundário , Técnicas de Imagem por Elasticidade/métodos , Endossonografia/métodos , Neoplasias Pulmonares/patologia , Linfonodos/diagnóstico por imagem , Metástase Linfática/diagnóstico por imagem , Estadiamento de Neoplasias/métodos , Idoso , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma de Células Escamosas/diagnóstico por imagem , Comorbidade , Sistemas Computacionais , Técnicas de Imagem por Elasticidade/instrumentação , Humanos , Masculino , Mediastino/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA