RESUMO
BACKGROUND: The combination of highly localized impedance (LI) and contact force (CF) may improve tissue characterization and lesion prediction during radiofrequency (RF) pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). OBJECTIVE: We report the outcomes of our acute and long-term clinical evaluation of CF-LI-guided PVI in consecutive AF ablation cases from an international multicenter clinical setting. METHODS: Three hundred twenty-four consecutive patients from 20 European centers undergoing RF catheter ablation with the Stablepoint™ catheter were enrolled in the CHARISMA registry. Of these, 275 had a minimum follow-up of 1 year and were included in the primary analysis. RESULTS: The mean procedure duration was 115 ± 47 min, and the mean fluoroscopy time was 9.9 ± 6 min. At the end of the procedures, all PVs had been successfully isolated in all study patients. Minor complications were reported in 12 patients (4.4%). At 1 year, 36 (13.1%) patients had had an AF recurrence, and freedom from antiarrhythmic drugs and AF recurrence was achieved in 228 (82.9%) patients. The recurrence rate was higher in patients with persistent AF (21/116, 18.1%) than in those with paroxysmal AF (15/159, 9.4%; p = 0.0459). On multivariate logistic analysis adjusted for baseline confounders, only time > 6 months from first diagnosis of AF to ablation (HR = 2.93, 95%CI 1.03 to 8.36, p = 0.0459) was independently associated with recurrences. CONCLUSION: An ablation strategy for PVI guided by CF-LI technology proved safe and effective and resulted in a low recurrence rate of AF over 1-year follow-up, irrespective of the underlying AF type. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice. (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.
RESUMO
AIMS: Superior vena cava (SVC) isolation during atrial fibrillation catheter ablation is limited by the risk of collateral damage to the sinus node and/or the phrenic nerve. Due to its tissue-specificity, we hypothesized the feasibility and safety of pulsed-field ablation (PFA)-based SVC isolation. METHODS AND RESULTS: One hundred and five consecutive patients undergoing PFA-based AF catheter ablation were prospectively included. After pulmonary vein isolation (±posterior wall isolation and electrical cardioversion), SVC isolation was performed using a standardized workflow. Acute SVC isolation was achieved in 105/105 (100%) patients after 6 ± 1 applications. Transient phrenic nerve stunning occurred in 67/105 (64%) patients but without phrenic nerve palsy at the end of the procedure and at hospital discharge. Transient high-degree sinus node dysfunction occurred in 5/105 (4.7%) patients, with no recurrence at the end of the procedure and until discharge. At the 3-month follow-up visit, no complication occurred. CONCLUSION: SVC isolation using a pentaspline PFA catheter is feasible and safe.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Estudos de Viabilidade , Veia Cava Superior , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Masculino , Feminino , Veia Cava Superior/cirurgia , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Estudos Prospectivos , Veias Pulmonares/cirurgia , Cateteres Cardíacos , Desenho de Equipamento , Nervo Frênico/lesõesRESUMO
BACKGROUND: Automated detection of sleep apnea (SA) by pacemaker (PM) has been proposed and exhibited good agreement with polysomnography to detect severe SA. We aimed to evaluate the usefulness of SA monitoring algorithm in elderly patients with diastolic dysfunction. METHODS: Consecutive patients referred to the Caen University Hospital for PM implantation between May 2016 and December 2018 presenting isolated diastolic dysfunction were eligible for the study. The respiratory disturbance index (RDI) measured by the PM, and the mean monthly RDI (RDIm), were compared to the apnea hypopnea index (AHI) assessed with portable monitor for severe SA diagnosis. RESULTS: During the study period, 68 patients were recruited, aged of 80.4 ± 8.2 years. 63 patients underwent polygraphy with a portable monitor: 57 presented SA (83.8%), including 16 with severe SA (23.5%). Eight were treated with continuous positive airway pressure (CPAP). We found the RDI cutoff value of 22 events/h to predict severe SA, with 71.4% sensitivity and 65.2%, specificity. The RDIm cutoff value to detect severe SA was 19 events/h, with a sensitivity of 60% and a specificity of 66%. There was a significant reduction in RDI (p = 0.041), RDIm (p = 0.039) and AHI (p = 0.002) after CPAP. Supraventricular arrhythmias were frequent in all patients, regardless of SA severity, considering either episodes occurrence or total burden. CONCLUSION: In a population of elderly patients with PM and diastolic dysfunction, the SA monitoring algorithm was able to detect severe SA, with good diagnostic performance values, but also to provide follow-up data for the patients treated with CPAP.
Assuntos
Marca-Passo Artificial , Síndromes da Apneia do Sono , Idoso , Humanos , Sono , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia , Polissonografia , AlgoritmosRESUMO
BACKGROUND: Very few data have been published on the use of subcutaneous implantable cardioverter-defibrillators (S-ICDs) in patients with congenital heart disease (CHD). OBJECTIVES: The aim of this study was to analyze outcomes associated with S-ICDs in patients with CHD. METHODS: This nationwide French cohort including all patients with an S-ICD was initiated in 2020 by the French Institute of Health and Medical Research. Characteristics at implantation and outcomes were analyzed in patients with CHD. RESULTS: From October 12, 2012, to December 31, 2019, among 4,924 patients receiving an S-ICD implant in 150 centers, 101 (2.1%) had CHD. Tetralogy of Fallot, univentricular heart, and dextro-transposition of the great arteries represented almost one-half of the population. Patients with CHD were significantly younger (age 37.1 ± 15.4 years vs 50.1 ± 14.9 years; P < 0.001), more frequently female (37.6% vs 23.0%; P < 0.001), more likely to receive an S-ICD for secondary prevention (72.3% vs 35.9%; P < 0.001), and less likely to have severe systolic dysfunction of the systemic ventricle (28.1% vs 53.1%; P < 0.001). Over a mean follow-up period of 1.9 years, 16 (15.8%) patients with CHD received at least 1 appropriate shock, with all shocks successfully terminating the ventricular arrhythmia. The crude risk of appropriate S-ICD shock was twice as high in patients with CHD compared with non-CHD patients (annual incidences of 9.0% vs 4.4%; HR: 2.1; 95% CI: 1.3-3.4); however, this association was no longer significant after propensity matching (especially considering S-ICD indication, P = 0.12). The burden of all complications (HR: 1.2; 95% CI: 0.7-2.1; P = 0.4) and inappropriate shocks (HR: 0.9; 95% CI: 0.4-2.0; P = 0.9) was comparable in both groups. CONCLUSIONS: In this nationwide study, patients with CHD represented 2% of all S-ICD implantations. Our findings emphasize the effectiveness and safety of S-ICD in this particularly high-risk population. (S-ICD French Cohort Study [HONEST]; NCT05302115).
Assuntos
Desfibriladores Implantáveis , Cardiopatias Congênitas , Transposição dos Grandes Vasos , Humanos , Feminino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Morte Súbita Cardíaca/etiologia , Estudos de Coortes , Resultado do Tratamento , Estudos Retrospectivos , Cardiopatias Congênitas/complicações , Cardiopatias Congênitas/terapiaRESUMO
Background: Highly localized impedance (LI) measurements during atrial fibrillation (AF) ablation have the potential to act as a reliable predictor of the durability of the lesions created. Objective: We aimed to collect data on the procedural parameters affecting LI-guided ablation in a large multicenter registry. Methods: A total of 212 consecutive patients enrolled in the CHARISMA registry and undergoing their first pulmonary vein (PV) isolation for paroxysmal and persistent AF were included. Results: In all, 13,891 radiofrequency (RF) applications of ≥3â s duration were assessed. The first-pass PV isolation rate was 93.3%. A total of 80 PV gaps were detected. At successful ablation spots, baseline LI and absolute LI drop were larger than at PV gap spots (161.4 ± 19â Ω vs. 153.0 ± 13â Ω, p < 0.0001 for baseline LI; 22.1 ± 9â Ω vs. 14.4 ± 5â Ω, p < 0.0001 for LI drop). On the basis of Receiver operating characteristic curve analysis, the ideal LI drop, which predicted successful ablation, was >21â Ω at anterior sites and >18â Ω at posterior sites. There was a non-linear association between the magnitude of LI drop and contact-force (CF) (r = 0.14, 95% CI: 0.13-0.16, p < 0.0001) whereas both CF and LI drop were inversely related with delivery time (DT) (-0.22, -0.23 to -0.20, p < 0.0001 for CF; -0.27, -0.29 to -0.26, p < 0.0001 for LI drop). Conclusion: An LI drop >21â Ω at anterior sites and >18â Ω at posterior sites predicts successful ablation. A higher CF was associated with an increased likelihood of ideal LI drop. The combination of good CF and adequate LI drop allows a significant reduction in RF DT. Clinical trial registration: http://clinicaltrials.gov/, identifier: NCT03793998.
RESUMO
AIMS: Heart transplantation (HT) can be proposed as a therapeutic strategy for patients with severe refractory electrical storm (ES). Data in the literature are scarce and based on case reports. We aimed at determining the characteristics and survival of patients transplanted for refractory ES. METHODS AND RESULTS: Patients registered on HT waiting list during the following days after ES and eventually transplanted, from 2010 to 2021, were retrospectively included in 11 French centres. The primary endpoint was in-hospital mortality. Forty-five patients were included [82% men; 55.0 (47.8-59.3) years old; 42.2% and 26.7% non-ischaemic dilated or ischaemic cardiomyopathies, respectively]. Among them, 42 (93.3%) received amiodarone, 29 received (64.4%) beta blockers, 19 (42.2%) required deep sedation, 22 had (48.9%) mechanical circulatory support, and 9 (20.0%) had radiofrequency catheter ablation. Twenty-two patients (62%) were in cardiogenic shock. Inscription on wait list and transplantation occurred 3.0 (1.0-5.0) days and 9.0 (4.0-14.0) days after ES onset, respectively. After transplantation, 20 patients (44.4%) needed immediate haemodynamic support by extracorporeal membrane oxygenation (ECMO). In-hospital mortality rate was 28.9%. Predictors of in-hospital mortality were serum creatinine/urea levels, need for immediate post-operative ECMO support, post-operative complications, and surgical re-interventions. One-year survival was 68.9%. CONCLUSION: Electrical storm is a rare indication of HT but may be lifesaving in those patients presenting intractable arrhythmias despite usual care. Most patients can be safely discharged from hospital, although post-operative mortality remains substantial in this context of emergency transplantation. Larger studies are warranted to precisely determine those patients at higher risk of in-hospital mortality.
Assuntos
Oxigenação por Membrana Extracorpórea , Transplante de Coração , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Arritmias Cardíacas/etiologia , Choque Cardiogênico/etiologia , Oxigenação por Membrana Extracorpórea/métodosRESUMO
BACKGROUND: Conduction system pacing (CSP) is an emerging and promising approach for physiological ventricular pacing. While data from randomized controlled trials are scarce, use of His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP) has increased in France. AIM: To perform a national snapshot survey for cardiac electrophysiologists to evaluate adoption of CSP in France. METHODS: An online survey, distributed to every senior cardiac electrophysiologist in France, was conducted in November 2022. RESULTS: A total of 120 electrophysiologists completed the survey. Eighty-three (69%) respondents reported experience in undertaking CSP procedures and 27 (23%) were planning to start performing CSP in the coming 2 years. The implantation techniques and criteria used for successful implantation differed significantly among operators. The most frequent indications for HBP and LBBAP were high-degree atrioventricular block with left ventricular ejection fraction (LVEF) < 40% (24 and 82%, respectively) or with LVEF ≥ 40% (27 and 74%, respectively), and after failure of a coronary sinus left ventricular lead (27 and 71%, respectively). The limitations respondents most frequently perceived when performing HBP were bad sensing/pacing parameters (45%), increased procedure duration (41%) and risk of lead dislodgement (30%). The most frequently perceived limitations to performing LBBAP were absence of guidelines or consensus (31%), lack of medical training (23%) and increased procedure duration (23%). CONCLUSIONS: Our national survey-based study supports wide adoption of CSP in France. CSP is currently used as a second-line approach for both antibradycardia and resynchronization indications, with important variations regarding implantation techniques and criteria for measuring success.
Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Humanos , Volume Sistólico , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Eletrocardiografia , Função Ventricular Esquerda , Terapia de Ressincronização Cardíaca/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.
Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do TratamentoRESUMO
INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.
Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , FluoroscopiaRESUMO
Background: Myocardial inflammation has been consistently associated with genetic arrhythmogenic cardiomyopathy (ACM) and it has been hypothesized that episodes mimicking acute myocarditis (AM) could represent early inflammatory phases of the disease. Objective: We evaluated the temporal association between recurrent acute myocarditis (RAM) episodes and the later diagnosis of a genetic ACM. Materials and methods: Between January 2012 and December 2021, patients with RAM and no previous cardiomyopathy were included (Recurrent Acute Myocarditis Registry, NCT04589156). A follow-up visit including clinical evaluation, resting and stress electrocardiogram, cardiac magnetic resonance imaging, and genetic testing was carried out. Endpoints of the study was the incidence of both ACM diagnosis criteria and ACM genetic mutation at the end of follow-up. Results: Twenty-one patients with RAM were included and follow-up was completed in 19/21 patients (90%). At the end of follow-up, 3.3 ± 2.9 years after the last AM episode, 14/21 (67%) patients with an ACM phenotype (biventricular: 10/14, 71%; left ventricular: 4/14, 29%) underwent genetic testing. A pathogenic or likely pathogenic mutation was found in 8/14 patients (57%), 5/8 in the Desmoplakin gene, 2/8 in the Plakophillin-2 gene, and 1/8 in the Titin gene. Family history of cardiomyopathy or early sudden cardiac death had a positive predictive value of 88% for the presence of an underlying genetic mutation in patients with RAM. Conclusion: RAM is a rare entity associated with the latter diagnosis of an ACM genetic mutation in more than a third of the cases. In those patients, RAM episodes represent early inflammatory phases of the disease. Including RAM episodes in ACM diagnosis criteria might allow early diagnosis and potential therapeutic interventions.
RESUMO
AIMS: Sudden cardiac arrest remains a major complication of acute myocardial infarction (AMI) and is frequently related to ventricular fibrillation (VF). Incidence and impact of VF among patients hospitalized for AMI were evaluated. METHODS AND RESULTS: Data from the FAST-MI programme consisting of 5 French nationwide prospective cohort studies between 1995 and 2015 were analysed, totally including 14 423 patients with AMI (66 ± 14 years, 72% males, 59% ST-elevation myocardial infarction). Overall, proportion of patients presenting in-hospital VF decreased from 3.9% in 1995 to 1.8% in 2015 (P < 0.001). One-year mortality decreased from 60.7% to 24.6% (P < 0.001). However, compared with patients who did not develop VF, the over-risk of 1-year mortality associated with VF was stable over time [hazard ratio (HR) 6.78, 95% confidence interval (CI) 5.03-9.14 in 1995 and HR 6.64, 95% CI 4.20-10.49 in 2015, P = 0.52]. This increased mortality in the VF group was mainly related to fatal events occurring prior to hospital discharge, representing 86.2% of 1-year mortality, despite the very low rate of implantable cardioverter defibrillator in the VF group (2.6%). CONCLUSION: This study demonstrates that in-hospital VF incidence and mortality in the setting of AMI have significantly decreased over the past 20 years. Nevertheless, VF remained steadily associated with approximately a 10-fold increased relative risk of in-hospital mortality, without an impact on post-discharge mortality. Beyond long-term cardiac defibrillation strategy, these results emphasize the need to identify in-hospital interventions to further reduce mortality in VF patients. STUDY REGISTRATION: ClinicalTrials.gov Identifier: NCT00673036, NCT01237418, NCT02566200.
Assuntos
Infarto do Miocárdio , Fibrilação Ventricular , Masculino , Humanos , Feminino , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Fibrilação Ventricular/terapia , Estudos Prospectivos , Assistência ao Convalescente , Alta do Paciente , Infarto do Miocárdio/complicações , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/terapia , Fatores de RiscoAssuntos
Ablação por Cateter , Taquicardia Supraventricular , Feminino , Fluoroscopia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Gravidez , Gestantes , Punções , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/etiologia , Resultado do TratamentoRESUMO
The IntellaMap OrionTM (Boston Scientific) is a 64-electrode basket catheter allowing for ultrahigh-density mapping of complex cardiac arrhythmias. We report the case of a basket catheter vascular entrapment, requiring surgical removal.
Assuntos
Flutter Atrial , Ablação por Cateter , Arritmias Cardíacas/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Eletrodos , Desenho de Equipamento , HumanosRESUMO
AIMS: The explosion of novel anticancer therapies has meant emergence of cardiotoxicity signals including atrial fibrillation (AF). Reliable data concerning the liability of anticancer drugs in inducing AF are scarce. Using the World Health Organization individual case safety report database, VigiBase®, we aimed to determine the association between anticancer drugs and AF. METHODS AND RESULTS: A disproportionality analysis evaluating the multivariable-adjusted reporting odds ratios for AF with their 99.97% confidence intervals was performed for 176 U.S. Food and Drug Administration (FDA)- or European Medicines Agency (EMA)-labelled anticancer drugs in VigiBase®, followed by a descriptive analysis of AF cases for the anticancer drugs identified in VigiBase®. ClinicalTrial registration number: NCT03530215. A total of 11 757 AF cases associated with at least one anticancer drug were identified in VigiBase® of which 95.8% were deemed serious. Nineteen anticancer drugs were significantly associated with AF of which 14 (74%) are used in haematologic malignancies and 9 (45%) represented new AF associations not previously confirmed in literature including immunomodulating agents (lenalidomide, pomalidomide), several kinase inhibitors (nilotinib, ponatinib, midostaurin), antimetabolites (azacytidine, clofarabine), docetaxel (taxane), and obinutuzumab, an anti-CD20 monoclonal antibody. CONCLUSION: Although cancer malignancy itself may generate AF, we identified 19 anticancer drugs significantly associated with a significant increase in AF over-reporting. This pharmacovigilance study provides evidence that anticancer drugs themselves could represent independent risk factors for AF development. Dedicated prospective clinical trials are now required to confirm these 19 associations. This list of suspected anticancer drugs should be known by physicians when confronted to AF in cancer patients, particularly in case of haematologic malignancies.