Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
J Artif Organs ; 27(1): 57-64, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36752993

RESUMO

The AtriClip device enables the safe and reproducible epicardial clipping of the left atrial appendage. Transapical off-pump beating heart mitral valve repair using NeoChord DS100 Artificial Chordae Delivery System has matured and become more standardized. We aim to evaluate the feasibility of combining NeoChord repair and left atrial appendage exclusion in a single procedure through the same minithoracotomy in patients with mitral valve prolapse and atrial fibrillation. From 2018 to 2019, seven patients with severe mitral regurgitation and atrial fibrillation underwent transesophageal echocardiography-guided transapical off-pump mitral valve repair with the novel NeoChord DS 1000 system and concomitant left atrial appendage exclusion using the AtriClip Pro II device. Both procedures were performed via left mini-thoracotomy. The AtriClip device was applied after the NeoChord repair was done. All seven patients had less than moderate mitral regurgitation after the NeoChord repair and successful left atrial appendage occlusion. There were no device or procedure-related complications. Clinical follow-up revealed significant symptomatic improvement, and no cardiovascular complications were reported. Transesophageal echocardiography at 6-12 months post-procedure showed stable left atrial appendage occlusion with no residual flow between the left atrium and the left atrial appendage and a stump of less than 5 mm. Beating heart epicardial clipping of the left atrial appendage using AtriClip concomitant with transapical mitral valve repair using Neochord DS 1000 system is a feasible and safe treatment option in mitral valve prolapse and atrial fibrillation in patients with limited indications. However, its safety needs to be confirmed in a larger series of patients.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Prolapso da Valva Mitral , Humanos , Insuficiência da Valva Mitral/complicações , Insuficiência da Valva Mitral/cirurgia , Prolapso da Valva Mitral/complicações , Prolapso da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Estudos de Viabilidade , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Cordas Tendinosas
2.
Front Cardiovasc Med ; 9: 985644, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36440013

RESUMO

Transapical Neochord mitral valve repair has been proven to be a technically safe procedure to correct primary mitral regurgitation (MR). Recurrent MR due to ruptured artificial chords is rare. Here, we present 2 cases of recurrent severe MR due to the detached or partially ruptured artificial chords after the Neochord procedure.

3.
J Am Heart Assoc ; 11(10): e024060, 2022 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-35574957

RESUMO

Background Strategies to improve long-term prediction of heart failure and death in valvular surgery are urgently needed because of an increasing number of procedures globally. This study sought to report the prevalence, changes, and prognostic implications of concomitant hepatorenal dysfunction and malnutrition in valvular surgery. Methods and Results In 909 patients undergoing valvular surgery, 3 groups were defined based on hepatorenal function (the modified model for end-stage liver disease excluding international normalized ratio score) and nutritional status (Controlling Nutritional Status score): normal hepatorenal function and nutrition (normal), hepatorenal dysfunction or malnutrition alone (mild), and concomitant hepatorenal dysfunction and malnutrition (severe). Overall, 32%, 46%, and 19% of patients were classified into normal, mild, and severe groups, respectively. Over a 4.1-year median follow-up, mild and severe groups incurred a higher risk of mortality (hazard ratio [HR], 3.17 [95% CI, 1.40-7.17] and HR, 9.30 [95% CI, 4.09-21.16], respectively), cardiovascular death (subdistribution HR, 3.29 [95% CI, 1.14-9.52] and subdistribution HR, 9.29 [95% CI, 3.09-27.99]), heart failure hospitalization (subdistribution HR, 2.11 [95% CI, 1.25-3.55] and subdistribution HR, 3.55 [95% CI, 2.04-6.16]), and adverse outcomes (HR, 2.11 [95% CI, 1.25-3.55] and HR, 3.55 [95% CI, 2.04-6.16]). Modified model for end-stage liver disease excluding international normalized ratio and controlling nutritional status scores improved the predictive ability of European System for Cardiac Operative Risk Evaluation (area under the curve: 0.80 versus 0.73, P<0.001) and Society of Thoracic Surgeons score (area under the curve: 0.79 versus 0.72, P=0.004) for all-cause mortality. One year following surgery (n=707), patients with persistent concomitant hepatorenal dysfunction and malnutrition (severe) experienced worse outcomes than those without. Conclusions Concomitant hepatorenal dysfunction and malnutrition was frequent and strongly linked to heart failure and mortality in valvular surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Doença Hepática Terminal , Insuficiência Cardíaca , Desnutrição , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Doença Hepática Terminal/complicações , Doença Hepática Terminal/diagnóstico , Doença Hepática Terminal/cirurgia , Humanos , Desnutrição/complicações , Desnutrição/diagnóstico , Desnutrição/epidemiologia , Estado Nutricional , Prognóstico , Fatores de Risco , Índice de Gravidade de Doença
4.
Asian Cardiovasc Thorac Ann ; 30(7): 816-818, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35234054

RESUMO

A 71-year-old lady with dextrocardia and pure aortic regurgitation was treated with transcatheter aortic valve replacement using the transapical J-valve system. Good clinical and echocardiographic results were demonstrated at one-year follow-up. Herewith we describe this simple, safe, and a minimally invasive aortic valve replacement option for this condition.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Dextrocardia , Próteses Valvulares Cardíacas , Situs Inversus , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Dextrocardia/complicações , Dextrocardia/diagnóstico por imagem , Feminino , Humanos , Situs Inversus/complicações , Situs Inversus/diagnóstico por imagem , Resultado do Tratamento
5.
Front Cardiovasc Med ; 9: 686208, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35155624

RESUMO

BACKGROUND: The presence of tricuspid regurgitation (TR) is very common in patients with concomitant left-sided valve disease. Recent studies have advocated an additional grading of massive TR that is beyond severe. The present study sought to characterize the spectrum of TR in patients undergoing tricuspid annuloplasty (TA) and to evaluate the prognostic value of TR severity for post-operative outcome following TA. METHODS: A total of 176 patients who underwent TA with combined left-sided valve surgery, secondary to rheumatic valvular heart disease, were prospectively evaluated. The severity of TR was quantified by effective regurgitant orifice area (EROA) using the proximal isovelocity surface area method. Patients were categorized as having non-massive TR (EROA < 0.6 cm2) or massive TR (EROA ≥ 0.6 cm2). Adverse outcome was defined as all-cause mortality or heart failure requiring hospital admission following TA. RESULTS: A total of 55 (31%) patients were considered to have massive TR. Patients with massive TR had a greater right ventricular dimension but a smaller left ventricular dimension compared with those with non-massive TR. After a median follow-up of 39 months, 35 adverse events occurred. Cox-regression analysis showed that both continuous EROA and dichotomized EROA (massive vs. non-massive TR) were independently associated with adverse events even after multivariable adjustment. Further, Harrell C index demonstrated that the addition of massive TR provided better discrimination ability of a prediction model to known prognosticators following TA. CONCLUSIONS: Massive TR is common and up to 31% of study population had massive TR. Massive TR was associated with adverse outcome in patients undergoing TA. Classification of the severity of TR by quantitative measures and identification of massive TR in patients with concomitant left-sided valve disease are essential when considering the optimal timing of corrective surgery.

7.
J Am Soc Echocardiogr ; 32(12): 1516-1525, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31563435

RESUMO

BACKGROUND: The advent of three-dimensional echocardiography (3DE) enables detailed evaluation of the tricuspid valve (TV) apparatus; nonetheless, the clinical value of preoperative 3DE is unknown in patients undergoing tricuspid annuloplasty (TA). The aim of this study was to evaluate the prognostic value of TV geometric parameters and leaflet coaptation status evaluated by 3DE in patients undergoing TA. METHODS: A total of 122 patients who underwent TA during left-sided heart valve surgery were prospectively evaluated. Detailed 3DE was performed before surgery. Adverse outcome was defined as the occurrence of heart failure requiring hospital admission or all-cause mortality following TA. RESULTS: A total of 33 adverse events (17 heart failures and 16 deaths) occurred during a median follow-up of 36 months. Tethering volume (hazard ratio = 1.32; 95% CI = 1.05-1.66; P = .01) and ratio of total leaflet length to closure length (hazard ratio = 1.07; 95% CI = 1.03-1.12; P < .01) were associated with adverse events after adjustment for age, sex, and tricuspid regurgitation vena contracta width. Receiver-operator characteristic curve analysis revealed that tethering volume (area under curve = 0.73) and ratio of total leaflet length to closure length (area under curve = 0.75) were most associated with adverse events at 1-year follow-up. The presence of either a large tethering volume or a low ratio of total leaflet length to closure length was predictive of an adverse outcome 1 year following TA. CONCLUSIONS: Our study suggests that 3DE-derived TV tethering volume and ratio of total leaflet length to closure length are important preoperative measures associated with adverse events in patients undergoing TA.


Assuntos
Anuloplastia da Valva Cardíaca/métodos , Ecocardiografia Tridimensional/métodos , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Idoso , Estudos de Coortes , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Estudos Prospectivos , Curva ROC , Medição de Risco , Resultado do Tratamento , Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA