Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Thorac Cancer ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38831606

RESUMO

In this article, the multidisciplinary team of the Taiwan Academy of Tumor Ablation, who have expertise in treating lung cancer, present their perspectives on percutaneous image-guided thermal ablation (IGTA) of lung tumors. The modified Delphi technique was applied to reach a consensus on clinical practice guidelines concerning ablation procedures, including a comprehensive literature review, selection of panelists, creation of a rating form and survey, and arrangement of an in-person meeting where panelists agreed or disagreed on various points. The conclusion was a final rating and written summary of the agreement. The multidisciplinary expert team agreed on 10 recommendations for the use of IGTA in the lungs. These recommendations include terms and definitions, line of treatment planning, modality, facility rooms, patient anesthesia settings, indications, margin determination, post-ablation image surveillance, qualified centers, and complication ranges. In summary, IGTA is a safe and feasible approach for treating primary and metastatic lung tumors, with a relatively low complication rate. However, decisions regarding the ablation technique should consider each patient's specific tumor characteristics.

2.
Updates Surg ; 2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38872023

RESUMO

Lung nodule localization using conventional image-guided video-assisted thoracoscopic surgery involves lung puncture, which increases the risk of needle-related complications. We aimed to evaluate the feasibility and safety of a single-stage non-invasive laser-guided stamping localization technique followed by resection under general anesthesia in a hybrid operating room. We retrospectively reviewed consecutive patients who underwent thoracoscopic surgery for small pulmonary nodules using laser-guided dye-stamping localization methods in a hybrid operating room between June 2023 and October 2023. During the study period, 18 patients with 20 lesions underwent single-stage intraoperative image-guided stamping video-assisted thoracoscopic surgery in the hybrid operating room. The median size of the nodules was 7.4 mm (interquartile range [IQR] 5.7-9.8 mm), and median distance from the pleural surface was 9.8 mm (IQR 7.7-14.6 mm). The median localization time was 26 min (IQR 23-34 min), whereas median operation time was 69 min (IQR 62-87 min). The total median operating room time was 146 min (IQR 136-157 min). Twelve patients underwent less than two cone-beam computed tomography scans, while 6 underwent more than two scans. The total median dose area product, including cone-beam computed tomography scans, was 5731.4 uGym2. No localization-related complications were observed, and the postoperative length of stay was 1 day (IQR 1-2 days). The single-stage image-guided pleural stamping technique for localizing small pulmonary nodules in a hybrid operating room is feasible and safe. Future research with larger cohorts is required to further explore the benefits of this workflow.

3.
Acad Radiol ; 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38862349

RESUMO

RATIONALE AND OBJECTIVES: Percutaneous lung tumor ablations are mostly performed in computed tomography (CT) rooms under local anesthesia with conscious sedation. However, maintaining the breath-hold phase during this can be challenging, affecting image quality and increasing complications. With the advent of hybrid operating rooms (HORs), this procedure can be performed with endotracheal tube (ETGA) intubation under general anesthesia with lung separation, ensuring precise imaging in a single-stage setting. Lung separation provides surgical exposure of one lung while ensuring ample gas exchange with the other. This study evaluated tumor ablations performed in an HOR equipped with cone beam CT and laser guidance. MATERIALS AND METHODS: This retrospective study included patients who underwent lung tumor ablation under general anesthesia with an ETGA in an HOR between July 2020 and May 2023. Anesthesia considerations, perioperative management, and postoperative follow-ups were evaluated. RESULTS: 65 patients (78 tumors) underwent ablation using two types of lung ventilation methods including a single-lumen tube with a blocker (SLT/BL) (n = 15) and double-lumen tube (DLT) (n = 50). Most patients experienced desaturation during the apnea phase of dynamic CT and needling. The average SpO2 value was significantly lower in the DLT group than in the SLT/BL group during the procedure (81.1% versus 88.7%, P = 0.033). Five, three, and two patients developed pneumothorax, subcutaneous emphysema, and pleural effusion, respectively. CONCLUSION: Percutaneous ablation under general anesthesia with endotracheal intubation and lung separation performed in HORs was feasible and safe. The setup minimized complication risks and maintained a balance between patient safety and successful procedures.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38696085

RESUMO

PURPOSE: We developed a novel augmented fluoroscopy-guided intrathoracic stamping technique for localizing small pulmonary nodules in the hybrid operating room. We conducted an observational study to investigate the feasibility of this technique and retrospectively compared two augmented fluoroscopy-guided approaches: intrathoracic and transbronchial. METHODS: From August 2020 to March 2023, consecutive patients underwent single-stage augmented fluoroscopy-guided localization under general anaesthesia. This included intrathoracic stamping and bronchoscopic lung marking, followed by thoracoscopic resection in a hybrid operating room. Comparative analyses were performed between the two groups. RESULTS: The data of 50 patients in the intrathoracic stamping and 67 patients in the bronchoscopic lung marking groups were analysed. No significant difference was noted in demographic data between the groups, except a larger lesion depth in the bronchoscopic lung marking group (14.7 ± 11.7 vs 11.0 ± 5.8 mm, p = 0.029). Dye localization was successfully performed in 49 intrathoracic stamping group patients (98.0%) and 67 bronchoscopic lung marking group patients (100%). No major procedure-related complications occurred in either group; however, the time flow (total anaesthesia time/global operating room time) was longer, and the radiation exposure (fluoroscopy duration/total dose area product) was larger in the bronchoscopic lung marking group. CONCLUSIONS: Augmented fluoroscopic stamping localization under intubated general anaesthesia is feasible and safe, providing an alternative with less global operating room time and lower radiation exposure for image-guided thoracoscopic surgery in the hybrid operating room.

5.
Int J Infect Dis ; 139: 118-123, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37977501

RESUMO

OBJECTIVES: Persistent growth of Mycobacterium abscessus complex (MABC) in the respiratory system is not uncommon and may indicate continuous infection of MABC lung disease (MABC-LD), but its prevalence, risk factors, and clinical impact have not been investigated. METHODS: The present study was conducted in two medical centers in northern Taiwan. We enrolled patients with MABC-LD and investigated the prevalence and predictors of persistent culture positivity (MABC-PP). Furthermore, we analyzed the association between MABC-PP and radiographic or clinical progression. RESULTS: Among 189 patients with MABC-LD, 58 were in the MABC-PP group. Independent predictors for MABC-PP included an increasing radiographic score and highest acid-fast stain (AFS) of strong positivity (3-4+) at initial diagnosis (compared with negative AFS). MABC-PP and highest AFS were independently associated with MABC-LD progression by the multivariable analysis model. The adjusted hazard ratio increased to 3.56 when the two independent factors existed. CONCLUSIONS: MABC-PP accounted for 30.7% and was predicted by initial AFS grade and radiographic score. Patients with MABC-PP, and highest AFS grade might have disease progression.


Assuntos
Pneumopatias , Infecções por Mycobacterium não Tuberculosas , Mycobacterium abscessus , Humanos , Infecções por Mycobacterium não Tuberculosas/microbiologia , Prevalência , Pneumopatias/microbiologia , Fatores de Risco , Antibacterianos/uso terapêutico
6.
Eur Radiol ; 2023 Nov 06.
Artigo em Inglês | MEDLINE | ID: mdl-37926741

RESUMO

OBJECTIVES: The experience of thermal ablation of lung lesions is limited, especially performing the procedure under localisation by cone-beam CT in the hybrid operation room (HOR). Here, we present the experience of microwave ablation (MWA) of lung nodules in the HOR. METHODS: We reviewed patients who underwent image-guide percutaneous MWA for lung nodules in the HOR under general anaesthesia between July 2020 and July 2022. The workflow in the HOR including the pre-procedure preparation, anaesthesia consideration, operation methods, and postoperative care was clearly described. RESULTS: Forty lesions in 33 patients who underwent MWA under general anaesthesia (GA) in the HOR were analysed. Twenty-seven patients had a single pulmonary nodule, and the remaining six patients had multiple nodules. The median procedure time was 41.0 min, and the median ablation time per lesion was 6.75 min. The median global operation room time was 115.0 min. The median total dose area product was 14881 µGym2. The median ablation volume was 111.6 cm3. All patients were discharged from the hospital with a median postoperative stay of 1 day. Four patients had pneumothorax, two patients had pleural effusion during the first month of outpatient follow-up, and one patient reported intercostal neuralgia during the 3-month follow-up. CONCLUSIONS: Thermal ablation of pulmonary nodules under GA in the HOR can be performed safely and efficiently if we follow the workflow provided. The procedure provides an alternative to managing pulmonary nodules in patients. CLINICAL RELEVANCE STATEMENT: Thermal ablation of pulmonary nodules under GA in the HOR can be performed safely and efficiently if the provided workflow is followed. KEY POINTS: • We tested the feasibility of microwave ablation of lung lesions performed in a hybrid operating room. • To this end, we provide a description of microwave ablation of the lung under cone-beam CT localisation. • We describe a workflow by which ablation of the pulmonary nodule can be performed safely under general anaesthesia.

7.
Diagnostics (Basel) ; 13(6)2023 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-36980363

RESUMO

Lung cancer is the most lethal cancer type in Taiwan and worldwide. Early detection and treatment advancements have improved survival. However, small peripheral pulmonary nodules (PPN) biopsy is often challenging, relying solely on bronchoscopy with radial endobronchial ultrasound (EBUS). Augmented fluoroscopy overlays the intra-procedural cone-beam computed tomography (CBCT) images with fluoroscopy enabling real-time three-dimensional localization during bronchoscopic transbronchial biopsy. The hybrid operating room (HOR), equipped with various types of C-arm CBCT, is a perfect suite for PPN diagnosis and other interventional pulmonology. This study shares the single institute experience of EBUS transbronchial biopsy of PPN with the aid of augmented fluoroscopic bronchoscopy (AFB) and CBCT in an HOR. We retrospectively enrolled patients who underwent robotic CBCT, augmented fluoroscopy-guided, radial endobronchial ultrasound-confirmed transbronchial biopsy and cryobiopsy in a hybrid operating room. Patient demographic characteristics, computed tomography images, rapid on-site evaluation cytology, and final pathology reports were collected. Forty-one patients underwent transbronchial biopsy and 6 received additional percutaneous transthoracic core-needle biopsy during the same procedure. The overall diagnostic yield was 88%. The complications included three patients with pneumothorax after receiving subsequent CT-guided percutaneous transthoracic needle biopsy, and two patients with hemothorax who underwent transbronchial cryobiopsy. Overall, the bronchoscopic biopsy of PPN using AFB and CBCT as precise guidance in the hybrid operating room is feasible and can be performed safely with a high diagnostic yield.

8.
Eur J Cardiothorac Surg ; 63(1)2022 12 02.
Artigo em Inglês | MEDLINE | ID: mdl-36377779

RESUMO

OBJECTIVES: Hybrid operating rooms (HOR) have been increasingly used for image-guided lung surgery, and most surgical teams have used percutaneous localization for small pulmonary nodules. We evaluated the feasibility and safety of augmented fluoroscopic bronchoscopy localization under endotracheal tube intubation general anaesthesia followed by thoracoscopic surgery as a single-stage procedure in ab HOR. METHODS: We retrospectively reviewed clinical records of patients who underwent single-stage augmented fluoroscopic bronchoscopy localization under general anaesthesia followed by thoracoscopic surgery in an HOR between August 2020 and March 2022. RESULTS: Single-stage localization and resection were performed for 85 nodules in 74 patients. The median nodule size was 8 mm [interquartile range (IQR), 6-9 mm], and the median distance from the pleural space was 10.9 mm (IQR, 8-20 mm). All nodules were identifiable on cone-beam computed tomography images and marked transbronchially with indigo carmine dye (median markers per lesion: 3); microcoils were placed for deep margins in 16 patients. The median localization time was 30 min (IQR 23-42 min), and the median fluoroscopy duration was 3.3 min (IQR 2.2-5.3 min). The median radiation exposure (expressed as the dose area product) was 4303.6 µGym2 (IQR 2879.5-6268.7 µGym2). All nodules were successfully marked and resected, and the median global operating room time was 178.5 min (IQR 153.5-204 min). There were no localization-related complications, and the median length of postoperative stay was 1 day (IQR, 1-2 days). CONCLUSIONS: Single-stage augmented fluoroscopic bronchoscopy localization under general anaesthesia followed by thoracoscopic surgery was feasible and safe.


Assuntos
Neoplasias Pulmonares , Nódulos Pulmonares Múltiplos , Nódulo Pulmonar Solitário , Humanos , Salas Cirúrgicas , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/cirurgia , Estudos Retrospectivos , Broncoscopia , Cirurgia Torácica Vídeoassistida/métodos , Tomografia Computadorizada por Raios X/métodos , Nódulos Pulmonares Múltiplos/cirurgia , Fluoroscopia , Nódulo Pulmonar Solitário/cirurgia
9.
Dig Endosc ; 33(3): 458-463, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32462727

RESUMO

Adrenocorticotropic hormone (ACTH)-producing neuroendocrine neoplasm (NEN) of the thymus is rare. Lymph nodes and bones are the most common metastatic sites. Most cases present with florid Cushing's syndrome (CS). Here, we reported a 58-year-old woman, who presented with intermittent flush and weight loss. Imaging studies revealed tumors in the mediastinum, pancreas, and bones. Contrast-enhanced harmonic endoscopic ultrasound (EUS) of the pancreatic tumors showed heterogeneous and hyperenhancing characteristics. EUS elastography revealed a heterogeneous stiff pattern. EUS-fine needle biopsy to the pancreatic lesion confirmed the NEN nature. Serum ACTH and cortisol levels were abnormally high. Immunohistochemical staining of the thymic and pancreatic specimens was positive for ACTH. However, the patient did not have obvious CS appearance. The patient underwent surgery, radiation, EUS-guided ethanol injection, and anti-cancer medications, but the disease still progressed. The patient died from infection 16 months after NEN was diagnosed. In conclusion, the pancreas can be a metastatic site for ACTH-producing thymic NEN. EUS-associated procedures can help in the diagnosis and treatment of pancreatic metastatic NEN.


Assuntos
Tumores Neuroendócrinos , Neoplasias Pancreáticas , Hormônio Adrenocorticotrópico , Endossonografia , Feminino , Humanos , Pessoa de Meia-Idade , Tumores Neuroendócrinos/diagnóstico por imagem , Tumores Neuroendócrinos/cirurgia , Pâncreas , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/cirurgia
10.
Respirol Case Rep ; 8(2): e00532, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32042433

RESUMO

Current National Comprehensive Cancer Network (NCCN) guidelines suggest plasma-based testing (liquid biopsy) for T790M in epidermal growth factor receptor (EGFR)-mutated non-small cell lung carcinoma (NSCLC) with acquired resistance to first-/second-generation EGFR tyrosine kinase inhibitors (TKIs). Positivity for resistant mutation on liquid biopsy may obviate the need for invasive tissue biopsy. We report a rare case of primary resistance to osimertinib, although liquid biopsy revealed EGFR T790M positivity. A 63-year-old male, never smoker, was diagnosed with stage IV lung adenocarcinoma with EGFR exon 19 deletion. Treatment started with erlotinib and was continued for 15 months until disease progression. Osimertinib was initiated when liquid biopsy showed EGFR T790M positivity. However, primary resistance to osimertinib was noted on follow-up imaging. Re-biopsy revealed small cell lung cancer. Detection of T790M via liquid biopsy among NSCLC patients with acquired resistance to EGFR-TKI might miss other possible resistant mechanisms. Tissue biopsy should be considered to exclude small cell lung carcinoma (SCLC) transformation.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA