Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Med ; 12(19)2023 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-37834843

RESUMO

This study aimed to estimate scattered radiation and its spatial distribution around three cone-beam computed tomography (CBCT) devices, in order to determine potential positions for an operator to stand if they needed to be inside the CBCT room. The following devices were tested: Morita Accuitomo (CBCT1), Newtom Giano HR (CBCT2), Newtom VGi (CBCT3). Scattered radiation measurements were performed using different kVp, mA, and Field of View (FOV) options. An anthropomorphic phantom (NATHANIA) was placed inside the X-ray gantry to simulate clinical conditions. Scattered measurements were taken with the Inovision model 451P Victoreen ionization chamber once placed at fixed distances from each irradiation isocenter, away from the primary beam. A statistically significant (p < 0.001) difference was found in the mean value of the scattered radiation estimations between the CBCT devices. Scattered radiation was reduced with a different rate for each CBCT device as distance was increased. For CBCT1 the reduction was 0.047 µGy, for CBCT2 it was 0.036 µGy, and for CBCT3 it was 0.079 µGy, for every one meter from the X-ray gantry. Therefore, at certain distances from the central X-ray, the scattered radiation was below the critical level of 1 mGy, which is defined by the radiation protection guidelines as the exposure radiation limit of the general population. Consequently, an operator could stay inside the room accompanying the patient being scanned, if necessary.

2.
Diagnostics (Basel) ; 13(10)2023 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-37238271

RESUMO

This study aimed to assess and analyze the morphology and dimensions of the nasopalatine canal (NPC), as well as the adjacent buccal osseous plate (BOP), and to investigate the effect of gender, edentulism, NPC types, absence of maxillary central incisors (ACI) and age on the NPC and BOP, using cone beam computed tomography (CBCT). A total of 124 CBCT examinations (67 female and 57 male patients) were retrospectively included and evaluated. The assessment of the dimensions of the NPC, as well as the dimensions of the adjacent BOP, was performed by three Oral and Maxillofacial Radiologists on reconstructed sagittal and coronal CBCT sections under standardized conditions. Regarding the dimensions of the NPC and the adjacent BOP, the mean values were significantly higher among males than females. Furthermore, edentulous patients showed a significant reduction in BOP dimensions. Additionally, NPC types showed a significant effect on the length of the NPC, and the ACI had a significant effect on reducing BOP dimensions. Age had a significant effect on the diameter of the incisive foramen, with the mean values generally increasing with an increasing age. CBCT imaging of this anatomical structure contributes significantly to its full assessment.

3.
Int J Implant Dent ; 7(1): 40, 2021 05 24.
Artigo em Inglês | MEDLINE | ID: mdl-34027572

RESUMO

BACKGROUND: This study aims at determining the biological effect of 75/25 w/w nano-hydroxyapatite/chitosan (nHAp/CS) scaffolds on bone regeneration, in terms of fraction of bone regeneration (FBR), total number of osteocytes (Ost), and osteocyte cell density (CD), as well as its biodegradability. METHODS: Two critical-size defects (CSDs) were bilaterally trephined in the parietal bone of 36 adult Sprague-Dawley rats (18 males and 18 females); the left remained empty (group A), while the right CSD was filled with nHAp/CS scaffold (group B). Two female rats died postoperatively. Twelve, 11, and 11 rats were euthanized at 2, 4, and 8 weeks post-surgery, respectively. Subsequently, 34 specimens were resected containing both CSDs. Histological and histomorphometric analyses were performed to determine the FBR, calculated as [the sum of areas of newly formed bone in lateral and central regions of interest (ROIs)]/area of the original defect, as well as the Ost and the CD (Ost/mm2) in each ROI of both groups (A and B). Moreover, biodegradability of the nHAp/CS scaffolds was estimated via the surface area of the biomaterial (BmA) in the 2nd, 4th, and 8th week post-surgery. RESULTS: The FBR of group B increased significantly from 2nd to 8th week compared to group A (P = 0.009). Both the mean CD and the mean Ost values of group B increased compared to group A (P = 0.004 and P < 0.05 respectively). Moreover, the mean value of BmA decreased from 2nd to 8th week (P = 0.001). CONCLUSIONS: Based on histological and histomorphometric results, we support that 75/25 w/w nHAp/CS scaffolds provide an effective space for new bone formation.


Assuntos
Quitosana , Durapatita , Animais , Regeneração Óssea , Feminino , Masculino , Osteogênese , Ratos , Ratos Sprague-Dawley
4.
Clin Oral Investig ; 24(1): 437-446, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31104110

RESUMO

OBJECTIVES: Τhis study aims at determining the ability of cone beam computed tomography (CBCT) to visualize critical-size defects (CSD) created at rat calvaria and filled with 75/25 w/w nano-hydroxyapatite/chitosan (nHAp/CS) scaffolds, prior to their histological investigation. MATERIALS AND METHODS: Thirty adult Sprague Dawley rats, 15 males and 15 females, were used. Two CSD, 5 mm in diameter, were bilaterally trephined in the parietal bone. The right CSD was filled with nHAp/CS scaffold, while the left CSD remained empty, as the control group. Two female rats died post-operatively. Rats were euthanized at 2, 4, and 8 weeks post-surgery. Twenty-eight specimens (15 × 2 × 10 mm) were resected-containing both CSDs-and then scanned using a NewTom VGi CBCT imaging unit (Verona, Italy). The manufacturer's software trace region profile tool (NNT v6.2, Verona, Italy) was used in selected axial slices. The greyscale value (in VGiHU) and the traced/selected region of interest (ROI, in mm2) of those areas were automatically calculated. Subsequently, all specimens were histologically examined. RESULTS: An increased VGiHU (P = 0.000), was observed in the experimental group relative to the control group. The ROI of CSD (in mm2) was significantly reduced (P = 0.001) from the fourth to the eighth week in both groups. No statistically significant difference between male and female rats (P = 0.188) was observed with respect to VGiHU. CONCLUSIONS: The nHAp/CS scaffolds are easily visualized using a particular high-resolution CBCT device. CLINICAL RELEVANCE: Both the CBCT measurements and also the histological results suggest that the nHAp/CS scaffold presence contributes to new bone formation in rat calvarial CSD.


Assuntos
Quitosana , Tomografia Computadorizada de Feixe Cônico , Durapatita , Animais , Feminino , Itália , Masculino , Ratos , Ratos Sprague-Dawley , Crânio/diagnóstico por imagem , Crânio/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA