Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Vox Sang ; 109(4): 414-6, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26031441

RESUMO

Amotosalen-HCl-UVA (AI) is a process to inactivate pathogens in therapeutic plasma (FFP). Tolerance is the main residual issue in FFP transfusion, and only large series observations are powered enough to identify significantly elevated levels of hazards. We report here on 15,133 new transfusions of AI-FFP, over the previously published 36,035, which in all represents one of the largest series observed by means of a highly standardized surveillance (51.168 observations). There is no noticeable difference in terms of tolerance of AI-FFP compared to 5875 transfusions of Quarantine (Q)-FFP. There was no significant difference in terms of advance events, between the two types of FFP (P = 0.98); further, no difference was recorded either when the total number of AI-FFP (51,168) was compared to the corresponding number of Q-FFP (5875; P = 0.62).


Assuntos
Preservação de Sangue/métodos , Furocumarinas/efeitos adversos , Hipersensibilidade/epidemiologia , Reação Transfusional , Raios Ultravioleta/efeitos adversos , Preservação de Sangue/efeitos adversos , Transfusão de Sangue/estatística & dados numéricos , França , Humanos , Hipersensibilidade/etiologia
2.
Transfus Clin Biol ; 21(1): 31-6, 2014 Mar.
Artigo em Francês | MEDLINE | ID: mdl-24560485

RESUMO

In France, three varieties of therapeutic plasma are being processed, distributed and delivered, currently; however, many more varieties are in use worldwide, which go by the property of labile blood component or plasma derived medicines. For one type of component (one given name), several devices and bags and so on are used to concur to its process, which makes that one type of therapeutic plasma may significantly differ from one production setting to one other. This may affect (more or less) the component properties as well as the possibly reported adverse events. This review aims thus, firstly at stressing on the difficulty in comparing data obtained in different contexts, and secondly at making the point on future directions to process therapeutic plasma.


Assuntos
Transfusão de Sangue/classificação , Plasma , Humanos
3.
Vox Sang ; 104(4): 337-41, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-23294315

RESUMO

BACKGROUND AND OBJECTIVES: Our objective was to compare the frequency of adverse events (AEs) due to any of the 4 types of fresh-frozen plasma (FFP) prepared and delivered by the French Blood Establishment (EFS) over a 10-year period. Surveillance of AEs and vigilance was performed according to a homogeneous policy. The four types of FFP comprised of one type (methylene blue [MB) that was stopped since then and of another type [amotosalen (AI)] that was recently introduced, along with two conventional products [quarantine (Q) and solvent-detergent (SD)]. MATERIALS AND METHODS: This is a retrospective study based on the national AE reporting database and on the regional database system for deliveries. AEs recorded after the delivery of 1 of the 4 types of FFP were pairwise compared, with appropriate statistical corrections. RESULTS: 105,964 FFP units were delivered (38.4% Q, 17.9% SD, 9.7% MB and 34% AI). Statistical comparisons of AEs identified only a difference in AE rates between quarantine and solvent-detergent plasma. CONCLUSIONS: FFP was confirmed to be extremely safe in general, especially if one considers 'severe' AEs. All types of FFP were associated with extremely low occurrences of AEs. Q, SD, MB and AI led, respectively, to 7.14, 4.86, 1.05 and 4.16 AEs per 10,000 deliveries.


Assuntos
Segurança do Sangue/métodos , Transfusão de Sangue/normas , Plasma/química , Segurança do Sangue/instrumentação , Coleta de Dados , França , Humanos , Estudos Retrospectivos
4.
Transfus Clin Biol ; 18(4): 472-7, 2011 Aug.
Artigo em Francês | MEDLINE | ID: mdl-21783400

RESUMO

In the past few years, pathogen reduction technologies for labile blood products have been part of the enhancement of global transfusion safety regarding residual risks of transmitting infectious pathogens. Having carried out a feasibility study for the implementation of pathogen inactivation of platelet concentrates by means of the amotosalen/HCl/UVA (Intercept™) technology, and participated to a reinforced haemovigilance study, we took the opportunity to analyze the organization consequences for platelet concentrates inventory and distribution. This impact study first indicated that those novel needs forced the blood donation service, as well as the labile blood product preparation laboratory, to review and improve practices; secondly, it showed that the routine implementation has little (no major) consequence in the overall organization, independently of the economic consequences (not covered here).


Assuntos
Patógenos Transmitidos pelo Sangue , Controle de Infecções/métodos , Transfusão de Plaquetas/efeitos adversos , Humanos , Controle de Infecções/organização & administração
5.
Transfus Clin Biol ; 18(1): 20-5, 2011 Feb.
Artigo em Francês | MEDLINE | ID: mdl-21237687

RESUMO

PURPOSE OF THE STUDY: Like every actor in transfusion, staff members practising within blood banks of healthcare establishments have to follow a specific initial training and must frequently update their knowledge in blood transfusion. METHODS: To address this need from these professionals, the Établissement français du sang Auvergne-Loire set up training sessions which content regularly evolved according to regulation recommendations. Every cycle consists in a total of 35hours of training, divided in five one-day modules. The comparison of the evaluation questionnaires offered at the beginning and at the end of each day allowed to measure the benefits provided by every module and to compare progress according to the number of modules previously followed. The analysis of satisfaction surveys contributed to improving the education towards a high level of satisfaction of every participant. RESULTS CONCLUSION: At the end of its third year of existence, the 35hours education programme permitted to achieve a better level of training for all the staffs and the evolution towards an on-site continuing education format seems to better correspond to the personnel's expectations.


Assuntos
Bancos de Sangue , Educação Continuada , Transfusão de Sangue , Currículo , Avaliação Educacional , França , Humanos , Capacitação em Serviço , Satisfação no Emprego , Prática Profissional , Avaliação de Programas e Projetos de Saúde , Inquéritos e Questionários
6.
Vox Sang ; 100(2): 247-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20735811

RESUMO

BACKGROUND AND OBJECTIVES: INTERCEPT Blood System™ is a pathogen inactivation system for blood components. The initial approval required a platelet component to be suspended in a combination of plasma and Platelet additive Solution/PAS-III. Improved platelet storage has been reported with Mg++ and K+ supplementation (PAS-IIIM). This study validated the use of INTERCEPT™/PAS-IIIM for apheresis and pooled buffy-coat platelet components. MATERIALS AND METHODS: The platelet dose and pH throughout 5 days of storage met the European and French requirements for quality standards. RESULTS AND CONCLUSION: Additional metabolic and activation assessments of the treated platelets confirmed the previously reported superiority of PAS-IIIM over PAS-III, but extended it to the INTERCEPT™ process.


Assuntos
Remoção de Componentes Sanguíneos , Plaquetas , Preservação de Sangue , Desinfecção , Raios Ultravioleta , Desinfecção/instrumentação , Desinfecção/métodos , Feminino , Furocumarinas/farmacologia , Humanos , Concentração de Íons de Hidrogênio , Masculino , Fatores de Tempo
7.
Transfus Clin Biol ; 17(1): 9-13, 2010 Feb.
Artigo em Francês | MEDLINE | ID: mdl-20106699

RESUMO

We recently observed a near fatal case of transfusion-transmitted infection with standard platelet concentrate. Streptococcus dysgalactiae subspecies equisimilis was isolated both from donor, residual component container and cultures of the patient's blood. This should question the usefulness of systematic bacterial detection in platelet concentrates, however a lethal accident has occurred recently which escaped bacterial detection. This observation calls for implementation of pathogen inactivation procedures for platelets concentrates.


Assuntos
Bacteriemia/transmissão , Transfusão de Plaquetas/efeitos adversos , Choque Séptico/etiologia , Infecções Estreptocócicas/transmissão , Streptococcus/isolamento & purificação , Bacteriemia/diagnóstico , Bacteriemia/microbiologia , Técnicas de Tipagem Bacteriana , Doadores de Sangue , Contaminação de Equipamentos , Feminino , Humanos , Leucemia Mieloide Aguda/complicações , Programas de Rastreamento , Pessoa de Meia-Idade , Faringe/microbiologia , Transfusão de Plaquetas/instrumentação , Choque Séptico/microbiologia , Especificidade da Espécie , Infecções Estreptocócicas/diagnóstico , Trombocitopenia/etiologia , Trombocitopenia/terapia
8.
Transfus Clin Biol ; 16(1): 4-11, 2009 Mar.
Artigo em Francês | MEDLINE | ID: mdl-19324582

RESUMO

We represent an organization of transfusionnel advice at a regional level and we develop arguments and stages having allowed us to lead to this choice. This target was reached in two stages, which took place over 3 years. The regional transfusionnel advice leans on three fundamental points: a planned permanent organization, skilled and formed actors as well as adapted tools. Tending to a homogeneous organization between every blood bank center seems to be coherent towards the current configuration of blood donation in France.


Assuntos
Bancos de Sangue/organização & administração , Transfusão de Sangue , Consultores , Aconselhamento/organização & administração , Transfusão de Componentes Sanguíneos , Preservação de Sangue/métodos , Preservação de Sangue/normas , Tomada de Decisões , França , Hospitais Universitários/organização & administração , Humanos , Prescrições , Avaliação de Programas e Projetos de Saúde , Meios de Transporte
9.
Int J Immunopathol Pharmacol ; 18(1): 65-74, 2005.
Artigo em Inglês | MEDLINE | ID: mdl-15698512

RESUMO

With the addition of various cytokines, the CD40-CD40 ligand (CD40L) system can act as a T-helper cell surrogate to permit B lymphocytes to produce large amounts of polyclonal Ig. In the present study, we tested six CD40-CD40L stimulation models: (i, ii) soluble agonistic 89 and G28.5 mAbs ; (iii, iv) 89 and G28.5 bound via their Fc fragments on CDw32-transfected mouse fibroblasts; (v) purified, soluble, trimeric human CD40L molecules (sCD40L); and (vi) human CD40L expressed by a CD40L-transfected mouse fibroblastic cell line (LCD40L). Target B cells consisted of purified blood and tonsillar CD19+ lymphocytes cultured in the presence of CD40 stimuli and IL-2 and IL-10, added at the onset of each B cell culture. A) There was differential expression of CD69, CD80 and CD86 exposure to sCD40L and LCD40L was ensued by the strongest % MFI changes over control. B) In blood B cells, mAbs and sCD40L induced IgA, IgM and IgG production almost equally well; LCD40L proved less efficient. In contrast, in tonsil B cells, LCD40L induced significantly more IgA, IgG1, IgG3 and IgM production than other signals. Using certain CD40/CD40L stimuli to model in vitro Ig production, a system used regularly in many laboratories, may affect the interpretation based on the cell type and on the CD40/CD40L system used.


Assuntos
Anticorpos Monoclonais/farmacologia , Linfócitos B/metabolismo , Antígenos CD40/metabolismo , Animais , Antígenos CD19/farmacologia , Diferenciação Celular/fisiologia , Membrana Celular/metabolismo , Células Cultivadas , Ensaio de Imunoadsorção Enzimática , Fibroblastos/metabolismo , Citometria de Fluxo , Humanos , Imunoglobulina A/imunologia , Fragmentos Fc das Imunoglobulinas/imunologia , Imunoglobulina G/imunologia , Cadeias Pesadas de Imunoglobulinas/imunologia , Imunoglobulina M/imunologia , Indicadores e Reagentes , Camundongos , Tonsila Palatina/citologia , Transfecção
10.
Clin Exp Immunol ; 132(2): 304-8, 2003 May.
Artigo em Inglês | MEDLINE | ID: mdl-12699421

RESUMO

HIV1-gp160 holds promises in anti-HIV vaccinal strategies. However, this molecule has been described to exhibit superantigenic activities. The present study aimed at examining the effect(s) of HIV1-gp160 on human B cells and in particular on B cells originating from HIV- donors. We purified human B cells of various origins, i.e. from blood and from tonsils (representing a mucosal-type origin), and we tested these cells (stimulated with a polyclonal B cell activator, interleukin (IL)-2 and IL-10 as cytokines, and recombinant HIV1-gp160) for the production of IgG and IgA in an in vitro model. Gp160 induced significantly less total IgG by blood - but not tonsil-originating - B cells and did not affect total IgA production. Further, HIV1-gp160 up-regulated IL-2-, IL-4- and IL-10-mRNA levels in stimulated blood B cells (these cytokines are known to be active on B cell activation and differentiation). Interestingly, HIV1-gp160 also up-regulated IL-1beta-, transforming growth factor (TGF)-beta-, interferon (IFN)-gamma- and IL-12-mRNA levels in stimulated mucosal-type, tonsil-originating, B cells. As these latter cytokines are involved in proinflammatory activities, HIV-gp160 delivery at the mucosal sites would be compatible with an adjuvant activity.


Assuntos
Linfócitos B/imunologia , Citocinas/biossíntese , Proteína gp160 do Envelope de HIV/farmacologia , Soronegatividade para HIV/imunologia , Imunoglobulinas/biossíntese , Tonsila Palatina/imunologia , Células Cultivadas , Citocinas/genética , Humanos , Imunoglobulina A/biossíntese , Imunoglobulina G/biossíntese , Interleucina-1/biossíntese , Interleucina-1/genética , Interleucina-10/farmacologia , Interleucina-12/biossíntese , Interleucina-12/genética , Interleucina-2/farmacologia , Interleucina-6/biossíntese , Interleucina-6/genética , Ativação Linfocitária , RNA Mensageiro/análise , Reação em Cadeia da Polimerase Via Transcriptase Reversa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA