Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Neuroimage ; 152: 299-311, 2017 05 15.
Artigo em Inglês | MEDLINE | ID: mdl-28254511

RESUMO

A comprehensive analysis of the Parkinson's Progression Markers Initiative (PPMI) Dopamine Transporter Single Photon Emission Computed Tomography (DaTscan) images is carried out using a voxel-based logistic lasso model. The model reveals that sub-regional voxels in the caudate, the putamen, as well as in the globus pallidus are informative for classifying images into control and PD classes. Further, a new technique called logistic component analysis is developed. This technique reveals that intra-population differences in dopamine transporter concentration and imperfect normalization are significant factors influencing logistic analysis. The interactions with handedness, sex, and age are also evaluated.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/diagnóstico por imagem , Imageamento Tridimensional/métodos , Doença de Parkinson/diagnóstico por imagem , Tomografia Computadorizada de Emissão de Fóton Único/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Núcleo Caudado/diagnóstico por imagem , Progressão da Doença , Feminino , Globo Pálido/diagnóstico por imagem , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Doença de Parkinson/classificação , Análise de Componente Principal , Putamen/diagnóstico por imagem , Processamento de Sinais Assistido por Computador , Tropanos/administração & dosagem
3.
IEEE Trans Med Imaging ; 31(6): 1213-27, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22328178

RESUMO

External beam radiation therapy (EBRT) for the treatment of cancer enables accurate placement of radiation dose on the cancerous region. However, the deformation of soft tissue during the course of treatment, such as in cervical cancer, presents significant challenges for the delineation of the target volume and other structures of interest. Furthermore, the presence and regression of pathologies such as tumors may violate registration constraints and cause registration errors. In this paper, automatic segmentation, nonrigid registration and tumor detection in cervical magnetic resonance (MR) data are addressed simultaneously using a unified Bayesian framework. The proposed novel method can generate a tumor probability map while progressively identifying the boundary of an organ of interest based on the achieved nonrigid transformation. The method is able to handle the challenges of significant tumor regression and its effect on surrounding tissues. The new method was compared to various currently existing algorithms on a set of 36 MR data from six patients, each patient has six T2-weighted MR cervical images. The results show that the proposed approach achieves an accuracy comparable to manual segmentation and it significantly outperforms the existing registration algorithms. In addition, the tumor detection result generated by the proposed method has a high agreement with manual delineation by a qualified clinician.


Assuntos
Algoritmos , Imageamento por Ressonância Magnética/métodos , Reconhecimento Automatizado de Padrão/métodos , Radioterapia Guiada por Imagem/métodos , Técnica de Subtração , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/radioterapia , Feminino , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Radioterapia Conformacional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
Inf Process Med Imaging ; 22: 525-37, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21761683

RESUMO

Image guided external beam radiation therapy (EBRT) for the treatment of cancer enables accurate placement of radiation dose to the cancerous region. However, the deformation of soft tissue during the course of treatment, such as in cervical cancer, presents significant challenges. Furthermore, the presence of pathologies such as tumors may violate registration constraints and cause registration errors. In this paper, we present a unified MAP framework that performs automatic segmentation, nonrigid registration and tumor detection simultaneously. It can generate a tumor probability map while progressively identifing the boundary of an organ of interest based on the achieved transformation. We demonstrate the approach on a set of 30 T2-weighted MR images, and the results show that the approach performs better than similar methods which separate the registration and segmentation problems. In addition, the detection result generated by the proposed method has a high agreement with the manual delineation by a qualified clinician.


Assuntos
Algoritmos , Interpretação de Imagem Assistida por Computador/métodos , Reconhecimento Automatizado de Padrão/métodos , Radioterapia Assistida por Computador/métodos , Técnica de Subtração , Neoplasias do Colo do Útero/patologia , Neoplasias do Colo do Útero/radioterapia , Inteligência Artificial , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Modelos Biológicos , Modelos Estatísticos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Med Image Anal ; 15(5): 772-85, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21646038

RESUMO

External beam radiotherapy (EBRT) has become the preferred options for nonsurgical treatment of prostate cancer and cervix cancer. In order to deliver higher doses to cancerous regions within these pelvic structures (i.e. prostate or cervix) while maintaining or lowering the doses to surrounding non-cancerous regions, it is critical to account for setup variation, organ motion, anatomical changes due to treatment and intra-fraction motion. In previous work, manual segmentation of the soft tissues is performed and then images are registered based on the manual segmentation. In this paper, we present an integrated automatic approach to multiple organ segmentation and nonrigid constrained registration, which can achieve these two aims simultaneously. The segmentation and registration steps are both formulated using a Bayesian framework, and they constrain each other using an iterative conditional model strategy. We also propose a new strategy to assess cumulative actual dose for this novel integrated algorithm, in order to both determine whether the intended treatment is being delivered and, potentially, whether or not a plan should be adjusted for future treatment fractions. Quantitative results show that the automatic segmentation produced results that have an accuracy comparable to manual segmentation, while the registration part significantly outperforms both rigid and nonrigid registration. Clinical application and evaluation of dose delivery show the superiority of proposed method to the procedure currently used in clinical practice, i.e. manual segmentation followed by rigid registration.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Algoritmos , Teorema de Bayes , Feminino , Humanos , Masculino , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Técnica de Subtração , Integração de Sistemas
6.
Artigo em Inglês | MEDLINE | ID: mdl-20879214

RESUMO

Many current image-guided radiotherapy (IGRT) systems incorporate an in-room cone-beam CT (CBCT) with a radiotherapy linear accelerator for treatment day imaging. Segmentation of key anatomical structures (prostate and surrounding organs) in 3DCBCT images as well as registration between planning and treatment images are essential for determining many important treatment parameters. Due to the image quality of CBCT, previous work typically uses manual segmentation of the soft tissues and then registers the images based on the manual segmentation. In this paper, an integrated automatic segmentation/constrained nonrigid registration is presented, which can achieve these two aims simultaneously. This method is tested using 24 sets of real patient data. Quantitative results show that the automatic segmentation produces results that have an accuracy comparable to manual segmentation, while the registration part significantly outperforms both rigid and non-rigid registration. Clinical application also shows promising results.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Radioterapia Assistida por Computador/métodos , Técnica de Subtração , Tomografia Computadorizada por Raios X/métodos , Humanos , Masculino , Intensificação de Imagem Radiográfica/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Integração de Sistemas
7.
Int J Radiat Oncol Biol Phys ; 65(2): 535-47, 2006 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-16690436

RESUMO

PURPOSE: To develop an accurate, fast, and robust algorithm for registering portal and computed tomographic (CT) images for radiotherapy using a combination of sparse and dense field data that complement each other. METHODS AND MATERIALS: Gradient Feature Weighted Minimax (GFW Minimax) method was developed to register multiple portal images to three-dimensional CT images. Its performance was compared with that of three others: Minimax, Mutual Information, and Gilhuijs' method. Phantom and prostate cancer patient images were used. Effects of registration errors on tumor control probability (TCP) and normal tissue complication probability (NTCP) were investigated as a relative measure. RESULTS: Registration of four portals to CTs resulted in 30% lower error when compared with registration with two portals. Computation time increased by nearly 50%. GFW Minimax performed the best, followed by Gilhuijs' method, the Minimax method, and Mutual Information. CONCLUSIONS: Using four portals instead of two lowered the registration error. Reduced fields of view images with full feature sets gave similar results in shorter times as full fields of view images. In clinical situations where soft tissue targets are of importance, GFW Minimax algorithm was significantly more accurate and robust. With registration errors lower than 1 mm, margins may be scaled down to 4 mm without adversely affecting TCP and NTCP.


Assuntos
Algoritmos , Imageamento Tridimensional/métodos , Neoplasias da Próstata/diagnóstico por imagem , Humanos , Masculino , Imagens de Fantasmas , Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiografia
8.
Phys Med Biol ; 49(8): 1387-408, 2004 Apr 21.
Artigo em Inglês | MEDLINE | ID: mdl-15152681

RESUMO

Compton cameras promise to improve the characteristics of nuclear medicine imaging, wherein mechanical collimation is replaced with electronic collimation. This leads to huge gains in sensitivity and, consequently, a reduction in the radiation dosage that needs to be administered to the patient. Design modifications that improve the sensitivity invariably compromise resolution. The scope of the current project was to determine an optimal design and configuration of a Compton camera that strikes a balance between these two properties. Transport of the photon flux from the source to the detectors was simulated with the camera geometry serving as the parameter to be optimized. Two variations of the Boltzmann photon transport equation, with and without photon polarization, were employed to model the flux. Doppler broadening of the energy spectra was also included. The simulation was done in a Monte Carlo framework using GEANT4. Two clinically relevant energies, 140 keV and 511 keV, corresponding to 99mTc and 18F were simulated. The gain in the sensitivity for the Compton camera over the conventional camera was 100 fold. Neither Doppler broadening nor polarization had any significant effect on the sensitivity of the camera. However, the spatial resolution of the camera was affected by these processes. Doppler broadening had a deleterious effect on the spatial resolution, but polarization improved the resolution when accounted for in the reconstruction algorithm.


Assuntos
Diagnóstico por Imagem/métodos , Câmaras gama , Ar , Algoritmos , Simulação por Computador , Meios de Contraste/farmacologia , Radioisótopos de Flúor/farmacologia , Humanos , Modelos Estatísticos , Modelos Teóricos , Método de Monte Carlo , Imagens de Fantasmas , Fótons , Radiometria/métodos , Sensibilidade e Especificidade , Silício , Iodeto de Sódio/química , Software , Tecnécio , Água
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA