Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Front Optoelectron ; 17(1): 16, 2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38833110

RESUMO

In current documented studies, it has been observed that wavelength converters utilizing AlGaAsOI waveguides exhibit suboptimal on-chip wavelength conversion efficiency from the C-band to the 2 µm band, generally falling below -20.0 dB. To address this issue, we present a novel wavelength conversion device assisted by a waveguide amplifier, incorporating both AlGaAs wavelength converter and erbium-ytterbium co-doped waveguide amplifier, thereby achieving a notable conversion efficiency exceeding 0 dB. The noteworthy enhancement in efficiency can be attributed to the specific dispersion design of the AlGaAs wavelength converter, which enables an upsurge in conversion efficiency to -15.54 dB under 100 mW of pump power. Furthermore, the integration of an erbium-ytterbium co-doped waveguide amplifier facilitates a loss compensation of over 15 dB. Avoiding the use of external optical amplifiers, this device enables efficient and high-bandwidth wavelength conversion, showing promising applications in various fields, such as optical communication, sensing, imaging, and beyond.

2.
Opt Express ; 32(11): 18562-18571, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38859009

RESUMO

The relative intensity noise (RIN) characteristics of a continuous-wave diamond Raman laser are investigated for the first time. The results reveal the parasitic stimulated Brillouin scattering (SBS) that usually occurred with higher-order spatial modes in the diamond Raman resonator is a pivotal factor impacting the Raman longitudinal modes and deteriorating the RIN level. The diamond Raman laser automatically switches to single-longitudinal-mode operation and the RIN level is significantly decreased in the frequency range of 200 Hz to 1 MHz after the parasitic SBS is effectively suppressed through inserting a spatial aperture or a χ(2) nonlinear crystal into the cavity. Due to the introduction of additional nonlinear loss to the high intensity Raman fluctuations and the non-lasing spontaneous Raman modes, the χ(2) nonlinear crystal enables better performance in the RIN-level reduction compared to the spatial aperture which can only achieve SBS inhibition. The RIN reduction routes are well suited for various crystalline Raman media to achieve high power and low intensity noise laser at different wavelengths.

3.
Opt Express ; 32(9): 16199-16211, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38859254

RESUMO

Single-crystal silicon (c-Si) is a vital component of photonic devices and has obvious advantages. Moreover, femtosecond-pulsed laser interactions with matter have been widely applied in micro/nanoscale processing. In this paper, we report the modification mechanisms of c-Si induced by a femtosecond laser (350 fs, 520 nm) at different pulse fluences, along with the mechanism of this technique to trim the phase error of c-Si-based devices. In this study, several distinct types of final micro/nanostructures, such as amorphization and ablation, were analyzed. The near-surface morphology was characterized using optical microscopy, scanning electron microscopy, and atomic force microscopy. The main physical modification processes were further analyzed using a two-temperature model. By employing Raman spectroscopy, we demonstrated that a higher laser fluence significantly contributes to the formation of more amorphous silicon components. The thickness of the amorphous layer was almost uniform (approximately 30 nm) at different induced fluences, as determined using transmission electron microscopy. From the ellipsometry measurements, we demonstrated that the refractive index increases for amorphization while the ablation decreases. In addition, we investigated the ability of the femtosecond laser to modify the effective index of c-Si microring waveguides by either amorphization or ablation. Both blue and red shifts of resonance spectra were achieved in the microring devices, resulting in double-direction trimming. Our results provide further insight into the femtosecond laser modification mechanism of c-Si and may be a practical method for dealing with the fabrication errors of c-Si-based photonic devices.

4.
Opt Express ; 32(12): 21870-21886, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38859531

RESUMO

In contrast to the passive remote sensing of global CO2 column concentrations (XCO2), active remote sensing with a lidar enables continuous XCO2 measurements throughout the entire atmosphere in daytime and nighttime. The lidar could penetrate most cirrus and is almost unaffected by aerosols. Atmospheric environment monitoring satellite (AEMS, also named DQ-1) aerosol and carbon dioxide detection Lidar (ACDL) is a novel spaceborne lidar that implements a 1572 nm integrated path differential absorption (IPDA) method to measure the global XCO2 for the first time. In this study, special methods have been developed for ACDL data processing and XCO2 retrieval. The CO2 measurement data products of ACDL, including the differential absorption optical depth between the online and offline wavelengths, the integral weighting function, and XCO2, are presented. The results of XCO2 measurements over the period from 1st June 2022 to 30th June 2022 (first month data of ACDL) are analyzed to demonstrate the measurement capabilities of the spaceborne ACDL system.

5.
Appl Opt ; 63(9): 2121-2131, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38568563

RESUMO

An integrated path differential absorption (IPDA) lidar can accurately measure regional C O 2 weighted column average concentrations (X C O 2), which are crucial for understanding the carbon cycle in climate change studies. To verify the performance and data inversion methods of space-borne IPDA lidar, in July 2021, we conducted an airborne lidar validation experiment in Dunhuang, Gansu Province, China. An aircraft was equipped with a lidar system developed to measure X C O 2 and an in situ greenhouse gas analyzer (GGA). To minimize measurement errors, energy monitoring was optimized. The system bias error of the DAOD was determined by changing the laser output mode from the off/on to the on/on mode. The X C O 2 inversion results obtained through comparing the schemes of averaging signals before "log (logarithm)" and averaging after "log" indicate that the former performs better. The IPDA lidar measured X C O 2 over the validation site at 405.57 ppm, and both the IPDA lidar and GGA measured sudden changes in the C O 2 concentration. The assimilation data showed a similar trend according to the altitude to the data measured by the in situ instrument. A comparison of the mean X C O 2 derived from the GGA results and assimilation data with the IPDA lidar measurements showed biases of 0.80 and 1.12 ppm, respectively.

6.
Appl Opt ; 62(29): 7844-7851, 2023 Oct 10.
Artigo em Inglês | MEDLINE | ID: mdl-37855495

RESUMO

In the development of the Cold Atom Physics Research Rack (CAPR) on board the Chinese Space Station, the laser system plays a critical role in preparing the all-optical 87 R b Bose-Einstein condensates (BECs). An all-fiber laser system has been developed for CAPR to provide the required optical fields for atom interaction and to maintain the beam pointing in long-term operation. The laser system integrates a 780 nm fiber laser system and an all-fiber optical control module for sub-Doppler cooling, as well as an all-fiber 1064 nm laser system for evaporative cooling. The high-power, single-frequency 780 nm lasers are achieved through rare-Earth doped fiber amplification, fiber frequency-doubling, and frequency stabilization technology. The all-fiber optical control module divides the output of the 780 nm laser system into 15 channels and regulates them for cooling, trapping, and probing atoms. Moreover, the power consistency of each pair of cooling beams is ensured by three power tracking modules, which is a prerequisite for maintaining stable MOT and molasses. A high-power, compact, controlled-flexible, and highly stable l064 nm all-fiber laser system employing two-stage ytterbium-doped fiber amplifier (YDFA) technology has been designed for evaporative cooling in the optical dipole trap (ODT). Finally, an all-optical 87 R b BEC is realized with this all-fiber laser system, which provides an alternative solution for trapping and manipulating ultra-cold atoms in challenging environmental conditions.

7.
Opt Express ; 31(16): 26078-26091, 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37710477

RESUMO

We have designed and fabricated a hybrid integrated laser source with full C-band wavelength tunability and high-power output. The external cavity laser is composed of a gain chip and a dual micro-ring narrowband filter integrated on the silicon nitride photonic chip to achieve a wavelength tuning range of 55 nm and a SMSR higher than 50 dB. Through the integration of the semiconductor optical amplifier in the miniaturized package, the laser exhibits an output power of 220 mW and linewidth narrower than 8 kHz over the full C-band. Such a high-power, narrow-linewidth laser diode with a compact and low-cost design could be applied whenever coherence and interferometric resolutions are needed, such as silicon optical coherent transceiver module for space laser communication, light detection and ranging (LiDAR).

8.
Research (Wash D C) ; 6: 0201, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37475723

RESUMO

Measuring the characteristics of seawater constituent is in great demand for studies of marine ecosystems and biogeochemistry. However, existing techniques based on remote sensing or in situ samplings present various tradeoffs with regard to the diversity, synchronism, temporal-spatial resolution, and depth-resolved capacity of their data products. Here, we demonstrate a novel oceanic triple-field-of-view (FOV) high-spectral-resolution lidar (HSRL) with an iterative retrieval approach. This technique provides, for the first time, comprehensive, continuous, and vertical measurements of seawater absorption coefficient, scattering coefficient, and slope of particle size distribution, which are validated by simulations and field experiments. Furthermore, it depicts valuable application potentials in the accuracy improvement of seawater classification and the continuous estimation of depth-resolved particulate organic carbon export. The triple-FOV HSRL with high performance could greatly increase the knowledge of seawater constituents and promote the understanding of marine ecosystems and biogeochemistry.

9.
Sensors (Basel) ; 23(11)2023 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-37299855

RESUMO

A tunable and narrow-bandwidth Q-switched ytterbium-doped fiber (YDF) laser is investigated in this paper. The non-pumped YDF acts as a saturable absorber and, together with a Sagnac loop mirror, provides a dynamic spectral-filtering grating to achieve a narrow-linewidth Q-switched output. By adjusting an etalon-based tunable fiber filter, a tunable wavelength from 1027 nm to 1033 nm is obtained. When the pump power is 1.75 W, the Q-switched laser pulses with a pulse energy of 10.45 nJ, and a repetition frequency of 11.98 kHz and spectral linewidth of 112 MHz are obtained. This work paves the way for the generation narrow-linewidth Q-switched lasers with tunable wavelengths in conventional ytterbium, erbium, and thulium fiber bands to address critical applications such as coherent detection, biomedicine, and nonlinear frequency conversion.


Assuntos
Lasers , Itérbio , Desenho de Equipamento , Luz , Érbio
10.
Opt Express ; 31(7): 11846-11863, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37155811

RESUMO

CO2 column-weighted dry-air mixing ratio (XCO2) products with high precision and spatial resolution are essential for inverting CO2 fluxes and promoting our understanding of global climate change. Compared with passive remote sensing methods, IPDA LIDAR, as an active remote sensing technique, offers many advantages in measuring XCO2. However, a significant random error in IPDA LIDAR measurements causes XCO2 values calculated directly from LIDAR signals to be unqualified as the final XCO2 products. Hence, we propose an efficient particle filter-based inversion of CO2 for single observation (EPICSO) algorithm to precisely retrieve the XCO2 of every LIDAR observation while preserving the high spatial resolution of LIDAR measurements. The EPICSO algorithm adopts the sliding average results as the first estimate of the local XCO2; subsequently, it estimates the difference between two adjacent XCO2 points and calculates the posterior probability of XCO2 based on particle filter theory. To evaluate the performance of the EPICSO algorithm numerically, we perform an EPICSO to process pseudo-observation data. The simulation results show that the results retrieved by the EPICSO algorithm satisfy the required high precision and that the algorithm is robust to a significant amount of random errors. In addition, we utilize LIDAR observation data from actual experiments in Hebei, China, to validate the performance of the EPICSO algorithm. The results retrieved by the EPICSO algorithm are more consistent with the actual local XCO2 than those of the conventional method, indicating that the EPICSO algorithm is efficient and practical for retrieving XCO2 with high precision and spatial resolution.

11.
Opt Express ; 31(8): 12311-12327, 2023 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-37157393

RESUMO

An in-situ laser Doppler current probe (LDCP) for the simultaneous measurements of the micro-scale subsurface current speed and the characterizations of micron particles is dedicated in this paper. The LDCP performs as an extension sensor for the state-of-the-art laser Doppler anemometry (LDA). The all-fiber LDCP utilized a compact dual wavelength (491 nm and 532 nm) diode pumped solid state laser as the light source to achieve the simultaneous measurements of the two components of the current speed. Besides its ability for the measurements of the current speed, the LDCP is also capable of obtaining the equivalent spherical size distribution of the suspended particles within small size range. The micro-scale measurement volume formed by two intersecting coherent laser beams makes it possible to accurately estimate the size distribution of the micron suspended particles with high temporal and spatial resolution. With its deployment during the field campaign at Yellow Sea, the LDCP has been experimentally demonstrated as an effective instrument to capture the micro-scale subsurface ocean current speed. The algorithm for retrieving the size distribution of the small suspended particles (2∼7.5µm) has been developed and validated. The combined LDCP system could be applied to the continuous long-term observations of plankton community structure, ocean water optical parameter over a wide range, and useful to elucidate the processes and interactions of the carbon cycles in the upper ocean.

12.
Opt Express ; 31(6): 10019-10026, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-37157553

RESUMO

In this work, we present a monolithic single-frequency, single-mode and polarization maintaining Yb-doped fiber (YDF) amplifier delivering up to 6.9 W at 972 nm with a high efficiency of 53.6%. Core pumping at 915 nm and elevated temperature of 300 °C were applied to suppress the unwanted 977 nm and 1030 nm ASE in YDF, so as to improve the 972 nm laser efficiency. In addition, the amplifier was further used to generate a single-frequency 486 nm blue laser with 590 mW of output power by single-pass frequency doubling.

13.
Natl Sci Rev ; 10(4): nwac180, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37089193

RESUMO

The invention of laser cooling has fundamentally influenced the research frontier of atomic physics and quantum physics, and recently an intense focus has been on the studies of cold atom physics in microgravity environments. Herein, we report the results of our laser cooling experiment in TianGong-2 space lab, which operated for 34 consecutive months in orbit. Over such an extended operation time, the quality of laser cooling did not experience any significant decline, while the properties of laser cooling in orbital microgravity were systematically studied. In particular, we demonstrate magneto-optical trapping and polarization-gradient cooling in orbit and carefully examine their performances. A comparison of the in-orbit and on-ground results indicates that a higher cooling efficiency exists in microgravity, including a smaller loss rate during the trapping and cooling process and lower ultimate temperature of laser-cooled atoms. Our progress has laid the technical foundations for future applications of cold atoms in space missions with operation times of the order of years.

14.
Opt Express ; 30(20): 35146-35162, 2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36258473

RESUMO

The spaceborne IPDA LIDAR has the potential to measure the global atmosphere CO2 column concentrations with high accuracy. For this kind of LIDAR, system calibration experiments in the laboratory are of high importance. In this study, a specially-customized CO2 absorption cell is employed to simulate the CO2 column absorption of the spaceborne platform. Then calibration experiments are constructed for the receiving system and the entire LIDAR system. The absorption of several different XCO2 concentrations from 400 to 415 ppm in the atmosphere is equivalent to that of the absorption cell charged with different pressures of pure CO2. Under the zero pressure of the absorption cell, the calculated equivalent column average concentration (XCO2) is 12.53 ppm, which acts as system bias. In the calibration experiments, the absolute errors are all less than 1 ppm. And the standard deviations (STDs) are less than 1.1 ppm (148-shot averaging) and 0.8 ppm (296-shot averaging) for receiving system and less than 1.2 ppm and 0.9 ppm for the IPDA LIDAR system. All the results of different average times are close to each other and less than 1 ppm, which proves the high accuracy of the IPDA LIDAR system. In addition, the XCO2 concentrations Allan deviation of 0.25 ppm and 0.35 ppm at 100 s shows that the receiving system and IPDA LIDAR system function with long-term stability. Using a CO2 absorption cell as a standard calibration device in the laboratory validates the measurement accuracy and stability of the spaceborne IPDA LIDAR prototype. Furthermore, the proposed absorption cell may serve as a standard calibration device for related atmosphere trace gases sounding research.

15.
J Cardiothorac Surg ; 17(1): 142, 2022 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-35668492

RESUMO

BACKGROUND: Bronchial rupture in children is a rare but dangerous complication after chest trauma and is associated with increased mortality. Veno-venous (V-V) extracorporeal membrane oxygenation (ECMO) is reported as one of the treatments for this life-threatening complication. CASE PRESENTATION: A 4-year-old boy with bronchial rupture and traumatic wet lung complicated by cardiac arrest after chest trauma was admitted to an adult ECMO centre. He experienced two cardiac arrests, one before and one during the operation. The total duration of cardiac arrest was 30 min. V-V ECMO was initiated because of severe hypoxia and hypercapnia during the operation. ECMO was performed for 6 days, and mechanical ventilation lasted 11 days. On the 31st day after surgery, he had recovered completely and was discharged without neurological deficit. CONCLUSION: V-V ECMO can be considered for supportive care in children with severe acute respiratory failure after bronchial rupture. In an emergency, V-V ECMO can be carried out effectively in a qualified and experienced adult ECMO centre. However, the application of ECMO in children is different from that in adults and requires more refined management.


Assuntos
Oxigenação por Membrana Extracorpórea , Parada Cardíaca , Lesão Pulmonar , Síndrome do Desconforto Respiratório , Traumatismos Torácicos , Adulto , Criança , Pré-Escolar , Parada Cardíaca/etiologia , Parada Cardíaca/terapia , Humanos , Masculino , Síndrome do Desconforto Respiratório/etiologia , Síndrome do Desconforto Respiratório/terapia , Ruptura , Traumatismos Torácicos/complicações
16.
Sensors (Basel) ; 22(10)2022 May 11.
Artigo em Inglês | MEDLINE | ID: mdl-35632065

RESUMO

Over the last two decades, Geiger-mode lidar (GML) systems have been developing rapidly in defense and commercial applications, demonstrating high point density and great collection efficiency. We presented a circular scanning GML system simulation model for performance prediction and developed a GML system for civilian mapping. The lidar system used an eye-safe fiber laser at 1545 nm coupled with a 64 × 64 pixels photon-counting detector array. A real-time data compression algorithm was implanted to reduce half of the data transmission rate and storage space compared to the uncompressing situation. The GML system can operate at aircraft above-ground levels (AGLs) between 0.35 km and 3 km, and at speeds in excess of 220 km/h. The initial flight tests indicate that the GML system can operate day and night with an area coverage of 366 km2/h. The standard deviations of the relative altimetric accuracy and the relative planimetric accuracy are 0.131 m and 0.152 m, respectively. The findings presented in this article guide the implementation of designing an airborne GML system and the data compression method.

17.
Biol Chem ; 403(3): 317-329, 2022 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-34882999

RESUMO

Abnormal proliferation of vascular smooth muscle cells (VSMCs) induced by insulin resistance facilitates intimal hyperplasia of type 2 diabetes mellitus (T2DM) and N6-methyladenosine (m6A) methylation modification mediates the VSMC proliferation. This study aimed to reveal the m6A methylation modification regulatory mechanism. In this study, m6A demethylase FTO was elevated in insulin-treated VSMCs and T2DM mice with intimal injury. Functionally, FTO knockdown elevated m6A methylation level and further restrained VSMC proliferation and migration induced by insulin. Mechanistically, FTO knockdown elevated Smooth muscle 22 alpha (SM22α) expression and m6A-binding protein IGF2BP2 enhanced SM22α mRNA stability by recognizing and binding to m6A methylation modified mRNA. In vivo studies confirmed that the elevated m6A modification level of SM22α mRNA mitigated intimal hyperplasia in T2DM mice. Conclusively, m6A methylation-mediated elevation of SM22α restrained VSMC proliferation and migration and ameliorated intimal hyperplasia in T2DM.


Assuntos
Diabetes Mellitus Tipo 2 , Insulinas , Animais , Movimento Celular/fisiologia , Proliferação de Células , Células Cultivadas , Diabetes Mellitus Tipo 2/metabolismo , Hiperplasia/metabolismo , Hiperplasia/patologia , Insulinas/metabolismo , Metilação , Camundongos , Músculo Liso Vascular/patologia , RNA Mensageiro/metabolismo
18.
Appl Opt ; 60(28): 8930-8938, 2021 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-34613122

RESUMO

With the development of laser communication networking, laser-ranging technology is becoming more and more applicable. In this paper, high-accuracy ranging is implemented based on intradyne coherent detection at a communication rate of 1048.576 Mbps. The ranging accuracy is affected by clock phase calculation error and code loop track error. Parallel clock phase difference calculation, frame head correlation, and ranging ambiguity region handle are combined with the ranging calibration method, realizing millimeter-level corrected distance measurement. Dynamic range measurement above 1 m is proven to be continuous through the ranging ambiguity region handle. In addition, high-precision clock frequency deviation between two asynchronous terminals can be obtained through derivation of one-way distance at static ranging or by derivative of distance difference at bidirectional ranging. The methods proposed in this paper are verified by inter-satellite laser-ranging on orbit, and the results are analyzed.

19.
Opt Express ; 29(18): 29449-29457, 2021 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-34615054

RESUMO

We report a diamond Raman laser that is continuously-tunable across the range from 590 nm to 625 nm producing continuous wave output with up to 8 W. The system is based on an all-fiber and tunable (1020-1072 nm) Yb-doped pump laser with a spectral linewidth of 25 GHz that is Raman-shifted and frequency doubled in a cavity containing diamond and a lithium triborate second harmonic crystal. Despite the broad pump spectrum, single frequency output is obtained across the tuning range 590-615 nm. The results reveal a practical approach to obtain tunable high-power single-frequency laser in a wavelength region not well served by other laser technologies.

20.
Appl Opt ; 59(10): C87-C91, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32400569

RESUMO

We have demonstrated a dual-wavelength blue-green laser for airborne ocean lidar based on an all-solid-state master oscillator power amplifier and nonlinear frequency conversion methods. A Q-switched pulsed laser with 10 mJ energy at 1064 nm was amplified to 108 mJ by a Nd:YAG amplifier side pumped by vertical-cavity surface-emitting laser modules. This fundamental laser was then frequency tripled to 355 nm wavelength by lithium triborate (LBO) crystals. With maximum pump energy of 43.5 mJ at 355 nm, 9.6 mJ of blue laser pulse at 486.1 nm was successfully obtained from an optical parametric oscillator unit using two beta-barium borate crystals. The energy of the residual 532 nm laser pulse was 10.6 mJ. Equipped with this laser system, an airborne blue-green lidar was developed, and ocean detection was carried out in the South China Sea, where an optical vertical profile at seawater depth of 94 m was obtained.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA