Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
1.
Front Cardiovasc Med ; 11: 1341663, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38590698

RESUMO

Introduction: Dyslipidemia is common in patients with abdominal aortic aneurysm (AAA). However, there is insufficient research on the impact of dyslipidemia on the postoperative outcomes of patients with AAA after endovascular aortic aneurysm repair (EVAR). This study aimed to determine the impact of dyslipidemia on the prognosis of patients with AAA treated with EVAR. Method: We retrospectively reviewed patients with AAA who underwent EVAR at our hospital between 2010 and 2020. The baseline characteristics and prognoses of patients in the dyslipidemia and non-dyslipidemia groups were analyzed. Results: A total of 641 patients were included; the prevalence of dyslipidemia in patients with AAA was 42.3% (271/641), and the mean follow-up time was 63.37 ± 26.49 months. The prevalence of diabetes (10.0% vs. 15.1%, P = 0.050), peripheral arterial disease (17.3% vs. 25.8%, P = 0.018), and chronic kidney disease (3.0% vs. 6.3%, P = 0.043) was higher in the dyslipidemia group. The three-year all-cause mortality rate after EVAR was 9.98% (64/641), and there was no difference in the incidence of all-cause mortality (10.27% vs. 9.59%, P = 0.778) between the two groups. A total of 36 (5.62%) major adverse cardiovascular and cerebrovascular events (MACCEs) were observed within 3 years and were more common in patients with dyslipidemia (2.97% vs. 9.59%, P < 0.001). The incidence of stent-related complications in all patients was 19.97% (128/641), and there was no difference in the incidence of stent-related complications between the two groups (22.16% vs. 16.97%, P = 0.105); however, the incidence of type I endoleak in the dyslipidemia group was lower than that in the non-dyslipidemia group (9.19% vs. 4.06%, P = 0.012). Cox-regression analysis showed that high level of high-density lipoprotein cholesterol (HDL-C) was the protective factor (HR, 0.203, 95% CI, 0.067-0.616, P = 0.005) for MACCES, but it was the risk factor for type I endoleak (HR, 2.317, 95% CI, 1.202-4.466, P = 0.012). Conclusion: Dyslipidemia did not affect the mortality of patients with AAA who underwent EVAR; however, it may increase the incidence of MACCEs. Dyslipidemia may decrease the incidence of type I endoleaks after EVAR; however, further studies are warranted. We should strengthen the postoperative management of patients with dyslipidemia, prevent the occurrence of MACCEs.

2.
Phys Chem Chem Phys ; 26(3): 2058-2065, 2024 Jan 17.
Artigo em Inglês | MEDLINE | ID: mdl-38126702

RESUMO

We investigated the linear and nonlinear response of the localized surface plasmons (LSPs) and surface plasmon polaritons (SPPs) in metal and MoS2 nanostructures. The results show that the response of LSPs and SPPs has an important influence on the energy exchange. SPPs with unique non-radiative characteristics can be used as energy recovery tanks to reuse the radiated energy of LSPs and promote the production of hot carriers. The energy exchange through plasmon modes can promote the transfer of hot electrons in the Au grating, the MoS2 layer, and the metal film. The fundamental field induces the increase of the second harmonic wave by introducing the second-order nonlinear source. In addition, the evolution of the lifetime of linear and nonlinear plasmonic modes is also investigated to study the underlying mechanism of the micro process in the plasmonic-photonic interaction. The plasmonic energy exchanging configuration overcomes the challenge by utilizing hot carriers. It is instructive in terms of improving the linear and nonlinear performance of plasmonic opto-electronic devices.

4.
Front Pediatr ; 11: 1257491, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37800010

RESUMO

Neonatal gastric perforation (NGP) is a rare, but life-threatening condition that can lead to serious conditions, such as capillary leak syndrome (CLS). Here, we present the case of a preterm male infant with NGP complicated by CLS after stomach repair. The patient was born at 33 2/7 weeks, weighed 1,770 g, and was diagnosed with respiratory distress syndrome. On the fourth day of life, the patient presented with distention and an unstable cardiovascular system. Routine blood tests revealed a white blood cell count of 2.4 × 109/L. Chest and abdominal radiography revealed a pneumoperitoneum, suggesting a gastrointestinal perforation. The patient was urgently transferred to a tertiary hospital for exploratory laparotomy, where a 2 cm diameter perforation was discovered in the stomach wall and subsequently repaired. Pathological findings indicated the absence of a muscular layer in the stomach wall. The patient unexpectedly developed CLS postoperatively, leading to multiorgan dysfunction and eventual death. The underlying pathological mechanism of NGP-induced CLS may be related to severe chemical peritonitis, sepsis, endothelial glycocalyx dysfunction, enhanced systemic inflammation, and translocation of the gut microbiota, causing endothelial hyperpermeability. Notablely, abdominal surgery itself can be a significant triggering factor for CLS occurrence. Complications of NGP and CLS are extremely dangerous. Investigating the mechanism by which NGP triggers CLS could potentially improve the prognosis. Conservative treatment for pneumoperitoneum secondary to gastric perforation may be a reasonable option, especially when the condition of the patient is unstable.

5.
Huan Jing Ke Xue ; 44(10): 5464-5477, 2023 Oct 08.
Artigo em Chinês | MEDLINE | ID: mdl-37827764

RESUMO

Accurately predicting energy consumption and carbon emission is important for China to make energy and carbon emission policy formulation more scientific and to achieve the goal of carbon peak before 2030 and carbon neutrality before 2060. Since energy demand is affected by numerous complex factors, it is hard to capture the dynamically developing rules of energy consumption comprehensively. Therefore, a novel two-layer decomposition-ensemble forecasting approach that was optimized by an improved particle swarm optimization algorithm based on simulation anneal and position disturbance strategy (IPSO) was proposed. Firstly, trend decomposition (TD) was utilized to break energy consumption time series down into a trend and a non-trend subseries. Then, empirical mode decomposition (EMD) was adopted to break the non-trend subseries down into several intrinsic mode functions (IMFs) and a residuum subseries. Subsequently, the aforementioned trend subseries, intrinsic mode functions, and residuum series were respectively modeled for prediction. The trend subseries was predicted using the multivariate linear regression model (MLR), which was optimized using IPSO. Both IMFs and residuum series were predicted using long short-term memory (LSTM). Finally, the final prediction of energy consumption was obtained by integrating the forecasting results of these subseries. According to China's energy consumption empirical analysis, the proposed IPSO-MLR-LSTM forecasting model based on the two-layer decomposition-ensemble approach using TD-EMD combined the advantages of TD, EMD, IPSO, and LSTM, which could comprehensively extract the developing rules of energy consumption by implementing a deeper decomposition strategy. Therefore, it is feasible and effective to apply the proposed forecasting model for energy consumption prediction. Finally, the energy consumption and carbon emissions of China under different energy consumption structure, economic growth, population, energy efficiency, and household energy consumption per capita scenarios in 2021-2035 were predicted. Then, some relevant policies and suggestions were put forward based on the forecasting results.

6.
J Clin Med ; 12(9)2023 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-37176518

RESUMO

Artificial intelligence (AI) is an interdisciplinary field that encompasses a wide range of computer science disciplines, including image recognition, machine learning, human-computer interaction, robotics and so on. Recently, AI, especially deep learning algorithms, has shown excellent performance in the field of image recognition, being able to automatically perform quantitative evaluation of complex medical image features to improve diagnostic accuracy and efficiency. AI has a wider and deeper application in the medical field of diagnosis, treatment and prognosis. Nasopharyngeal carcinoma (NPC) occurs frequently in southern China and Southeast Asian countries and is the most common head and neck cancer in the region. Detecting and treating NPC early is crucial for a good prognosis. This paper describes the basic concepts of AI, including traditional machine learning and deep learning algorithms, and their clinical applications of detecting and assessing NPC lesions, facilitating treatment and predicting prognosis. The main limitations of current AI technologies are briefly described, including interpretability issues, privacy and security and the need for large amounts of annotated data. Finally, we discuss the remaining challenges and the promising future of using AI to diagnose and treat NPC.

7.
Semin Cancer Biol ; 91: 124-142, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36906112

RESUMO

Based on the advantages of revealing the functional status and molecular expression of tumor cells, positron emission tomography (PET) imaging has been performed in numerous types of malignant diseases for diagnosis and monitoring. However, insufficient image quality, the lack of a convincing evaluation tool and intra- and interobserver variation in human work are well-known limitations of nuclear medicine imaging and restrict its clinical application. Artificial intelligence (AI) has gained increasing interest in the field of medical imaging due to its powerful information collection and interpretation ability. The combination of AI and PET imaging potentially provides great assistance to physicians managing patients. Radiomics, an important branch of AI applied in medical imaging, can extract hundreds of abstract mathematical features of images for further analysis. In this review, an overview of the applications of AI in PET imaging is provided, focusing on image enhancement, tumor detection, response and prognosis prediction and correlation analyses with pathology or specific gene mutations in several types of tumors. Our aim is to describe recent clinical applications of AI-based PET imaging in malignant diseases and to focus on the description of possible future developments.


Assuntos
Inteligência Artificial , Neoplasias , Humanos , Processamento de Imagem Assistida por Computador/métodos , Tomografia por Emissão de Pósitrons , Neoplasias/diagnóstico por imagem , Oncologia
8.
J Endovasc Ther ; 30(6): 892-903, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-35786093

RESUMO

PURPOSE: To investigate the safety and efficacy of fast-track management of concurrent percutaneous coronary intervention (PCI) in patients with abdominal aortic aneurysm scheduled for endovascular aortic aneurysm repair (EVAR). MATERIALS AND METHODS: Eligible patients with abdominal aortic aneurysm who received EVAR from January 2011 to December 2019 were included in this retrospective cohort study. Propensity score (PS)-matched analysis was used to balance the baseline between the fast-track and standard control (EVAR without significant coronary artery disease) groups. Effects of fast-track management on short-term and midterm outcomes were evaluated via Cox proportional hazard regression and logistic regression analyses with corresponding hazard ratio (HR) or odds ratio (OR) and associated 95% confidence intervals (95% CIs), respectively. RESULTS: The study included 669 patients (73 fast-track and 596 standard control). Compared with the standard control group, no significant difference was found regarding major adverse cardiac events (HR 0.78, 95% CI [0.36, 1.68], p=0.519), overall mortality (HR 0.63, 95% CI [0.25, 1.55], p=0.315), and 30-day major hemorrhage events (OR 1.01, 95% CI [0.99, 1.03], p=0.514). The results were consistent in the PS-matched cohorts regarding major adverse cardiac events (HR 0.57, 95% CI [0.25, 1.29], p=0.176), overall mortality (HR 0.43, 95% CI [0.17, 1.11], p=0.820), and 30-day major hemorrhage events (OR 1.00, 95% CI [0.05, 10.61], p=0.999). Similar results were found in the subgroup analyses concerning fast-track management of 2-week intervals and patients with high age-adjusted Charlson comorbidity index. CONCLUSIONS: Under appropriate perioperative care, shortening the time interval between PCI and EVAR to 1 month, or even 2 weeks, seemed to be safe and effective. Short-term and midterm cardiovascular and survival outcomes were comparable with patients who underwent standard EVAR without significant coronary artery disease.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Doença da Artéria Coronariana , Procedimentos Endovasculares , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Resultado do Tratamento , Complicações Pós-Operatórias/etiologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Hemorragia/etiologia , Fatores de Risco
9.
Sichuan Da Xue Xue Bao Yi Xue Ban ; 53(6): 988-992, 2022 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-36443039

RESUMO

Objective: To summarize our hospital's single-center experience of and reflections on the treatment of chronic limb-threatening ischemia (CLTI) of lower limbs combined with diabetes in the past 5 years. Methods: We retrospectively analyzed cases of lower limb CLTI combined with diabetes diagnosed at our hospital from March 2017 to June 2021. The baseline data, surgical information, and follow-up results of the patients were collected. The primary outcome indicator was the patency rate of lower limb target artery within 1 year post-op, and the secondary indicators were the reoperation rate within 1 year post-op and the amputation rate within 1 year post-op. Results: A total of 89 patients with lower limb CLTI combined with diabetes were included in the study. A total of 85 patients underwent percutaneous transluminal angioplasty and the operation of 7 patients ended in failure, with the operation success rate reaching 91.76% (78/85). Three patients underwent femoral popliteal artery bypass grafting with artificial blood vessels and one patient underwent iliac femoral artery bypass grafting with artificial blood vessels, with the success rate of the operations reachign 100% (4/4). Among 78 patients who successfully underwent percutaneous transluminal angioplasty, the median follow-up time was 33 months (13, 64). Two patients died within one year after operation, with the post-op one-year survival rate being 97.44% (76/78). The post-op 1-year reoperation rate was 19.23% (15/78), the 1-year target vascular patency rate (deaths not included) was 85.53% (65/76), and the 1-year amputation rate was 3.85% (3/78). Among the patients who underwent bypass surgery, the follow-up period was 13-48 months. No thrombosis in or re-occlusion of the artificial blood vessels were observed during the follow-up period, and the artificial blood vessels remained unoccluded. Conclusion: Transluminal angioplasty has a relatively ideal rate of postoperative vascular patency. In addition, it is a minimally invasive procedure involving low perioperative risks and is performed under local anesthesia. Therefore, it can be used as the preferred treatment for patients with CLTI. On the other hand, bypass surgery has good long-term patency rate, but it involves higher perioperative risks and the procedure is more invasive. Therefore, bypass surgery can be used as an alternative when transluminal angioplasty ends in failure.


Assuntos
Substitutos Sanguíneos , Diabetes Mellitus , Humanos , Isquemia Crônica Crítica de Membro , Estudos Retrospectivos , Extremidade Inferior
10.
World J Clin Cases ; 10(17): 5798-5804, 2022 Jun 16.
Artigo em Inglês | MEDLINE | ID: mdl-35979095

RESUMO

BACKGROUND: Hepatic artery aneurysm (HAA) is the second most common visceral aneurysm. A significant number of hepatic aneurysms are found accidentally on examination. However, their natural history is characterized by their propensity to rupture, which is very serious and requires urgent treatment. An emergent giant hepatic aneurysm with an abdominal aortic dissection is less commonly reported. CASE SUMMARY: We report the complicated case of a giant hepatic aneurysm with an abdominal aortic dissection. A 66-year-old female presented with the complaint of sudden upper abdominal pain accompanied by vomiting. Physical examination showed that her blood pressure was 214/113 mmHg. Her other vital signs were stable. Computed tomography found a giant hepatic proper aneurysm and dissection of the lower segment of the abdominal aorta. Furthermore, angiography showed a HAA with the maximum diameter of approximately 56 mm originating from the proper hepatic artery and located approximately 15 mm from the involved bifurcation of the left and right hepatic arteries with no collateral circulation. Therefore, we decided to use a stent to isolate the abdominal aortic dissection first, and then performed open repair. After the operation, the patient recovered well without complications, and her 3-month follow-up checkup did not reveal any late complications. CONCLUSION: Open surgery is a proven method for treating giant hepatic aneurysms. If the patient's condition is complex, staged surgery is an option.

11.
Front Plant Sci ; 13: 888939, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35720571

RESUMO

Gray mold caused by Botrytis cinerea, which is considered to be the second most destructive necrotrophic fungus, leads to major economic losses in strawberry (Fragaria × ananassa) production. B. cinerea preferentially infects strawberry flowers and fruits, leading to flower blight and fruit rot. Compared with those of the fruit, the mechanisms of flower defense against B. cinerea remain largely unexplored. Therefore, in this study, we aimed to unveil the resistance mechanisms of strawberry flower through dynamic and comparative transcriptome analysis with resistant and susceptible strawberry cultivars. Our experimental data suggest that resistance to B. cinerea in the strawberry flower is probably regulated at the transcriptome level during the early stages of infection and strawberry flower has highly complex and dynamic regulatory networks controlling a multi-layered defense response to B. cinerea. First of all, the higher expression of disease-resistance genes but lower expression of cell wall degrading enzymes and peroxidases leads to higher resistance to B. cinerea in the resistant cultivar. Interestingly, CPKs, RBOHDs, CNGCs, and CMLs comprised a calcium signaling pathway especially play a crucial role in enhancing resistance by increasing their expression. Besides, six types of phytohormones forming a complex regulatory network mediated flower resistance, especially JA and auxin. Finally, the genes involved in the phenylpropanoid and amino acids biosynthesis pathways were gene sets specially expressed or different expression genes, both of them contribute to the flower resistance to B. cinerea. These data provide the foundation for a better understanding of strawberry gray mold, along with detailed genetic information and resistant materials to enable genetic improvement of strawberry plant resistance to gray mold.

12.
Trials ; 23(1): 392, 2022 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-35549760

RESUMO

BACKGROUND: Covered stent has become one of the mainstream therapies for aortoiliac obstructive disease (AIOD), with a higher patency rate than bare metal stent. Covered balloon-expandable (CBE) stent can be placed more accurately with higher a radial support force, while covered self-expanding (CSE) stent has greater elasticity and higher trackability. However, there is no level I evidence regarding the comparison safety and efficacy between the CSE stent and CBE stent in AIOD to date. Therefore, this study aims to compare the efficacy and safety of CBE stent (BARD®LIFESTREAM™) and CSE stent (GORE® VIABAHN™) in AIOD. METHODS: This trial is a prospective, single-center, parallel, noninferiority, randomized controlled trial. A total of 106 patients will be enrolled and these patients will be randomized to either the CBE stent group or the CSE stent group. The primary end point of the study is the occurrence of target lesion revascularization (TLR) at 12 months after the intervention. DISCUSSION: To our knowledge, the ballooN sElf cOver steNt AorToiliAc occuLusive (NEONATAL) trial is the first RCT to compare CBE and CSE stent in AIOD patients. The main aim is to compare the TLR of the target lesion between CBE stent and CSE stent at 12 months post-procedure. The results of clinical trials may contribute to establishing a strategic guideline for choosing the optimal type of covered stent in the treatment of AIOD patients. TRIAL REGISTRATION: Chinese Clinical Trials Registry ChiCTR2100046734. Registered on 27 May 2021.


Assuntos
Angioplastia com Balão , Aterosclerose , Angioplastia com Balão/efeitos adversos , Humanos , Recém-Nascido , Estudos Prospectivos , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Stents , Resultado do Tratamento , Grau de Desobstrução Vascular
13.
Ann Vasc Surg ; 85: 1-8.e5, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35561891

RESUMO

BACKGROUND: Recent evidence raised the concern that paclitaxel-containing therapy was associated with an increased risk of mortality in patients with peripheral artery diseases (PADs). However, it is unclear whether drug-eluting stent (DES) versus drug-coated balloon (DCB) have a different effect on mortality of PAD patients. Our study aimed to systematically review current literature comparing clinical outcomes of patients treated with DES versus DCB for PAD. METHODS: MEDLINE and Embase were searched for eligible studies from January 2000 to December 31, 2020. Randomized controlled trials (RCTs) or cohort studies that reported outcomes of DES versus DCB were included in our study. The primary outcome was 12-month all-cause mortality. A random-effect model was used to pool the odds ratios (ORs) and related 95% confidence intervals (CIs). RESULTS: Our review included 7 studies, involving 2 RCTs and 5 cohort studies. A total of 4,237 patients with DES and 9,234 patients with DCB were analyzed. All included cohort studies were of high quality with Newcastle-Ottawa scores from 7 to 8. No significant difference in 12-month all-cause mortality was found between DES and DCB without significant heterogeneity (OR 1.02, 95% CI 0.91-1.14, I2 = 0%). As for primary patency, no significant difference between treatments was observed (OR 1.27, 95% CI 0.75-2.15, I2 = 55%). Similar results were observed for freedom from target lesion revascularization (OR 0.94, 95% CI 0.64-1.40, I2 = 0%). CONCLUSIONS: This systematic review and meta-analysis suggest that no significant difference in 12-month all-cause mortality was found between DES and DCB. Primary patency and freedom from target lesion revascularization of lower extremity PAD were also comparable between the 2 groups.


Assuntos
Angioplastia com Balão , Stents Farmacológicos , Doença Arterial Periférica , Angioplastia com Balão/efeitos adversos , Materiais Revestidos Biocompatíveis , Artéria Femoral/diagnóstico por imagem , Humanos , Extremidade Inferior , Paclitaxel/efeitos adversos , Doença Arterial Periférica/diagnóstico por imagem , Doença Arterial Periférica/etiologia , Doença Arterial Periférica/terapia , Artéria Poplítea/diagnóstico por imagem , Ensaios Clínicos Controlados Aleatórios como Assunto , Resultado do Tratamento
14.
Front Surg ; 9: 791553, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35433820

RESUMO

Hepatic artery pseudoaneurysm is a rare arterial disease. This case report describes a patient with hepatic artery pseudoaneurysm who presented with recurrent epigastric pain over a 4-month period. Computed tomography angiography (CTA) showed aneurysmal enlargement of the hepatic artery measuring 55 mm × 46 mm. The angiographic information is as follows: (1) the common hepatic artery originated from the superior mesenteric artery; (2) the proper hepatic artery originated from the common hepatic artery; (3) the proper hepatic aneurysmal disease had no collateral circulation. After careful consideration, the patient underwent an open surgical repair (OSR). The patient recovered well without any associated complications. The 1-year follow-up of patients did not reveal any relevant complications. The treatment choice, puzzles, and reflections of this case are all discussed in this article.

15.
J Vasc Surg ; 76(4): 1089-1098.e8, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35314303

RESUMO

OBJECTIVE: Iliac branch devices (IBDs) have been used in the treatment of aortoiliac and isolated iliac artery aneurysms. The aim of this systematic review and meta-analysis was to investigate the clinical effectiveness and safety of IBDs. METHODS: A systematic review of the literature was conducted by identifying studies in the Medline, EMBASE, and Cochrane databases regarding the outcomes of IBDs in aortoiliac or isolated iliac artery aneurysms between May 2006 and December 2020. Individual studies were evaluated for the following major outcomes: technical success, 30-day mortality, primary patency, endoleak, reintervention, and rates of pelvic ischemia. Furthermore, subgroup meta-analyses were performed to compare the pelvic ischemic events in patients with bilateral IBDs, unilateral IBDs, and bilateral internal iliac artery (IIA) embolization/coverage. RESULTS: Forty-five studies with a total of 2736 patients undergoing unilateral or bilateral IBDs met inclusion criteria and were included in the analysis. The pooled technical success rate of IBDs was 98.0% (confidence interval [CI]: 97.3%-98.7%). After IBD treatment, the 30-day mortality rate was 0.4% (CI: 0.07%-0.70%); 30-day patency was 98.4% (CI: 97.7%-99.0%); buttock claudication developed in 1.84% (CI: 1.26%-2.41%); and endoleak occurred in 11.9% (CI: 9.2%-14.7%) and reintervention in 7.6% (CI: 5.65%-9.58%). Furthermore, in patients with bilateral iliac artery involvement, the pooled estimate rates of buttock claudication were 0.7% in the bilateral IBD group, 7.9% in unilateral IBD with contralateral IIA embolization patients, and 33.8% in bilateral IIA embolization/coverage patients, which were statistically significant among the three groups. Sexual dysfunction was 5.0% in the bilateral IIA occlusion group, which was significantly higher than that in IBD groups. CONCLUSIONS: The utilization of IBDs in the treatment of aortoiliac or isolated iliac artery aneurysms is associated with high technical success rates as well as low incidences of pelvic ischemia. The risk of postoperative buttock claudication can be further decreased with both IIA preservation if patients are anatomically suitable for bilateral IBDs.


Assuntos
Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma Ilíaco , Prótese Vascular/efeitos adversos , Endoleak/etiologia , Humanos , Aneurisma Ilíaco/diagnóstico por imagem , Aneurisma Ilíaco/cirurgia , Artéria Ilíaca/diagnóstico por imagem , Artéria Ilíaca/cirurgia , Claudicação Intermitente , Isquemia/etiologia , Isquemia/terapia , Desenho de Prótese , Stents/efeitos adversos , Resultado do Tratamento
16.
J Vasc Interv Radiol ; 33(4): 375-383.e5, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34952197

RESUMO

PURPOSE: To assess the predictive value of geometric parameters for type Ia endoleak (T1AEL) after endovascular abdominal aortic aneurysm repair and to determine the range of optimal oversizing ratio (OSR) in patients with an elliptical cross-section of the aneurysm neck. MATERIALS AND METHODS: A propensity score-matched case-control study was conducted. Case patients were those who were diagnosed with T1AEL and control patients were those who did not have T1AEL after endovascular aneurysm repair during the period from 2012 to 2018. Geometric and oversizing parameters were compared based on both 2-dimensional (2D) and 3-dimensional measurements. Net reclassification improvement was used to measure the prediction increment of an elliptical model (major axis OSR, neck length, and severe neck angulation) compared with that of the conventional model (OSR 2D, neck length, and severe neck angulation). RESULTS: Nineteen case patients and 111 control patients were included. The median OSR 2D of patients with T1AEL was 17% (interquartile range, 15%-22%), but the median major axis OSR was only 7% (interquartile range, 5%-12%). For the geometric parameters, axis difference had the highest area under the curve (AUC) (0.74; 95% CI, 0.63-0.84) for predicting T1AEL. For the elliptical oversizing parameters, the major axis OSR had an AUC of 0.89 (95% CI, 0.78-0.97), with a cutoff value of 13%. The elliptical model had a higher discriminating ability for T1AEL than the conventional model (AUC 0.91 vs 0.86, respectively; P = .045), with an improved reclassification ability (net reclassification improvement, 27.93%; 95% CI, 19.22%-36.64%; P < .0001). CONCLUSIONS: Elliptical aneurysm neck cross-section, assessed by the difference between axis dimensions in the plane orthogonal to the centerline, was associated with an increased risk of T1AEL. The prescription of major axis oversizing of at least 13% can significantly reduce the risk of T1AEL formation in patients with an elliptical aneurysm neck.


Assuntos
Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/cirurgia , Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Estudos de Casos e Controles , Endoleak/diagnóstico por imagem , Endoleak/etiologia , Procedimentos Endovasculares/efeitos adversos , Humanos , Desenho de Prótese , Estudos Retrospectivos , Fatores de Risco , Stents/efeitos adversos , Resultado do Tratamento
17.
Chin Med J (Engl) ; 135(23): 2836-2842, 2022 Dec 05.
Artigo em Inglês | MEDLINE | ID: mdl-36728509

RESUMO

BACKGROUND: Endovascular abdominal aortic aneurysm repair (EVAR) is the major treatment for abdominal aortic aneurysm (AAA); however, EVAR still carries a considerable risk of acute kidney injury (AKI). The present study aimed to investigate the risk factors for AKI after elective EVAR procedures. METHODS: This was a retrospective observational study. Eligible patients who underwent EVAR from September 2011 to March 2019 in West China Hospital were included. The primary outcome was the occurrence of AKI within two days after EVAR, which was defined by the Kidney Disease Improving Global Outcomes Clinical Practice Guideline. Demographics, comorbidities, medications, laboratory tests, anatomical parameters of AAA, and relative operative details were collected as variables. Univariable and multivariable logistic regression analyses were applied to identify the risk factors among variables, and covariate interactions were further assessed. RESULTS: A total of 679 eligible patients were included. The incidence of postoperative AKI was 8.2% (56/679) in the whole cohort, and it was associated with a lower 5-year survival rate (63.5% vs . 80.9%; χ 2  = 4.10; P  = 0.043). The multivariable logistic regression showed that chronic kidney disease (OR, 5.06; 95% CI: 1.43-17.95; P  = 0.012), angiotensin-converting enzyme inhibitors (ACEIs)/angiotensin receptor blockers (ARBs) (OR, 2.60; 95% CI: 1.17-5.76; P  = 0.019), and short neck (OR, 2.85; 95% CI: 1.08-7.52; P  = 0.035) were independent risk factors for postoperative AKI. In the covariate interaction analysis, the effect of ACEIs/ARBs use on postoperative AKI was similar across all subgroups ( P  > 0.05), thereby suggesting a robust effect of ACEIs/ARBs use in all patients undergoing elective endovascular abdominal aortic aneurysm repair. CONCLUSIONS: Postoperative AKI was associated with lower survival rate, and the use of ACEIs/ARBs was the only adjustable independent risk factor. Clinicians should consider withdrawing ACEIs/ARBs in high-risk patients undergoing elective endovascular abdominal aortic aneurysm repair to prevent postoperative AKI.


Assuntos
Injúria Renal Aguda , Aneurisma da Aorta Abdominal , Implante de Prótese Vascular , Procedimentos Endovasculares , Humanos , Antagonistas de Receptores de Angiotensina/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Inibidores da Enzima Conversora de Angiotensina/efeitos adversos , Complicações Pós-Operatórias/tratamento farmacológico , Complicações Pós-Operatórias/epidemiologia , Injúria Renal Aguda/etiologia , Fatores de Risco , Estudos Retrospectivos , Aneurisma da Aorta Abdominal/cirurgia , Resultado do Tratamento
19.
Langmuir ; 36(32): 9540-9550, 2020 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-32698587

RESUMO

Microdrop generation with excellent controllability and volume precision is of paramount significance for a large variety of microfluidic applications. In this work, we propose a new configuration comprising only stripped electrodes of rectangular shape for the closed electrowetting-on-dielectric digital microfluidic (EWOD DMF) system and investigate its parallel microdrop generation outcomes via a numerical approach. The microfluidic droplet motion is solved by a finite-volume scheme on a fixed computational domain. The numerical model is verified by an experimental study of microdrop production from an EWOD DMF device with three different electrode designs. After model verification, we examine the influences of the equilibrium contact angle and the spacing of the microchannel on stripped electrode based microdrop generation outcomes and discover five different regimes including the phenomena of satellite droplet formation and separation cessation. Despite the various generation outcomes, the daughter droplet size is found to vary linearly with a dimensionless EWOD parameter κ*. More importantly, for all successful generations, the deviation of the daughter droplet size from that of the stripped electrode is smaller than 3.5%, which even reaches zero in proper conditions. This new configuration can be utilized as a convenient alternative for electrowetting-induced parallel microdrop production with excellent precision and controllability.

20.
J Vasc Surg ; 72(6): 2186-2196.e3, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32540324

RESUMO

OBJECTIVE: The comparison between paclitaxel-coated balloon (PCB) angioplasty and plain balloon angioplasty (PBA) for hemodialysis (HD) access stenosis or occlusion has not been well investigated. The objectives of this systematic review and meta-analysis were to compare all-cause mortality, HD access primary patency, and circuit primary patency after endovascular maintenance procedures using PCB angioplasty vs PBA. METHODS: MEDLINE, Embase, and Cochrane Databases were systematically searched to identify all the relevant studies on paclitaxel-coated devices for stenosis or thrombosis of HD access. A random effects model was applied to pool the effect measures. Dichotomous data were presented using an odds ratio (OR). Effect data were presented using pooled hazard ratio (HR) with 95% confidence interval (CI). RESULTS: A total of 16 studies were included in this meta-analysis, 12 randomized controlled trials and 4 cohort studies involving 1086 patients who underwent endovascular treatment for HD access stenosis or occlusion. All-cause mortality rates at 6, 12, and 24 months after intervention were similar between the PCB and PBA groups (6 months: OR, 1.06 [95% CI, 0.38-2.96; P = .907; I2 = 19.2%]; 12 months: OR, 1.20 [95% CI, 0.66-2.16; P = .554; I2 = 0%]; 24 months: OR, 1.43 [95% CI, 0.83-2.45; P = .195; I2 = 0%]). There was a significant improvement of primary patency in the PCB group compared with the PBA group (HR, 0.47; 95% CI, 0.33-0.69; P < .001; I2 = 67.3%). This benefit was consistent with the analysis of randomized controlled trials, whereas cohort studies were excluded. Further subgroup analysis of target lesions demonstrated that primary patency was significantly higher in the PCB group than in the PBA group, not only for arteriovenous fistula (HR, 0.54; 95% CI, 0.30-0.98; P = .041; I2 = 76.8%) but also for central venous stenosis (HR, 0.39; 95% CI, 0.22-0.71; P = .002; I2 = 0%). The PCB group was associated with higher 6-month (OR, 0.40; 95% CI, 0.27-0.59; P < .001) and 24-month lesion primary patency (OR, 0.28; 95% CI, 0.11-0.72; P = .009) than PBA and was marginally associated with 12-month lesion primary patency (OR, 0.52; 95% CI, 0.26-1.03; P = .06). Circuit primary patency analysis showed a marginal trend toward better outcome in the PCB group (HR, 0.63; 95% CI, 0.40-1.00) but no statistical significance (P = .052). CONCLUSIONS: This systematic review and meta-analysis demonstrated that PCB angioplasty is associated with significantly improved primary patency of arteriovenous fistula and central venous stenosis for HD access maintenance, with no evidence of increasing all-cause mortality based on short-term and midterm follow-up. Further large cohort study is needed to investigate long-term mortality.


Assuntos
Angioplastia com Balão/instrumentação , Derivação Arteriovenosa Cirúrgica/efeitos adversos , Implante de Prótese Vascular/efeitos adversos , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Oclusão de Enxerto Vascular/terapia , Paclitaxel/administração & dosagem , Diálise Renal , Dispositivos de Acesso Vascular , Grau de Desobstrução Vascular , Idoso , Idoso de 80 Anos ou mais , Angioplastia com Balão/efeitos adversos , Angioplastia com Balão/mortalidade , Derivação Arteriovenosa Cirúrgica/mortalidade , Implante de Prótese Vascular/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Oclusão de Enxerto Vascular/etiologia , Oclusão de Enxerto Vascular/mortalidade , Oclusão de Enxerto Vascular/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA