Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 164
Filtrar
1.
J Orthop Translat ; 49: 1-10, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39398971

RESUMO

Background: The fracture of bone plate can cause considerable pain for the patient and increase the burden on the public finances. This study aims to explore the failure mechanism of 49 plates retrieved from revision surgery and introduce pure magnesium (Mg) block to improve the biomechanical performance of the plate via decreasing the stiffness and to stimulate the biological response of the plate potentially by the degradation of Mg block. Methods: The morphological analysis and component analysis of the plates were conducted to determine the fracture reason of the plates combining the clinical data. According to the structural feature, the 49 retrieved plates were divided into: traditional plate (TP), asymmetrical plate (AP), reconstructive plate (RP) and central enhancement plate (CEP), and their structure features are normalized in a commercial plate, respectively. The biomechanical performance of the plates was evaluated using a validated femoral finite element model. A block of pure Mg with a thickness of 1 mm, 1.5 mm and 2 mm was also incorporated into the CEP to be assessed. Results: The results indicated that the retrieved plates mainly failed due to fatigue fracture induced by delayed union or nonunion (44/49), and using pure titanium plates in weight-bearing areas increased the risk of fracture compared with Ti alloy plates when the delayed union or nonunion occurred. The TP demonstrated the highest compression resistance and bending resistance, while CEP had the highest rotational resistance. As the thickness of the Mg block was increased, the stress on the plate in compression decreased, but the stress in rotation increased. The plate with a 1.5 mm Mg block demonstrated excellent compression resistance, bending resistance and rotational resistance. Conclusion: Fatigue fracture resulting from the delayed union or nonunion is the primary failure reason of plates in clinic. The incorporation of Mg block into plate improves the biomechanical performance and has the potential to promote bone healing. The plate with a 1.5 mm Mg block may be suitable for use in orthopaedics. The translational potential of this article: This study assessed the failure mechanism of retrieved bone plates and used this data to develop a novel plate incorporating a 1.5 mm block of pure Mg block at the position corresponding to the fracture line. The novel plate exhibited excellent compression resistance, bending resistance and rotational resistance due to the alleviation of stress concentrations. The Mg block has the potential to degrade over time to promote fracture healing and prevents fatigue fracture of plates.

2.
Bioengineering (Basel) ; 11(9)2024 Sep 15.
Artigo em Inglês | MEDLINE | ID: mdl-39329667

RESUMO

Musculoskeletal injuries are increasing in conjunction with the aging of populations and the rising frequency of exercise [...].

3.
Bioengineering (Basel) ; 11(8)2024 Aug 07.
Artigo em Inglês | MEDLINE | ID: mdl-39199755

RESUMO

Background: Total joint arthroplasty (TJA) is an orthopedic procedure commonly used to treat damaged joints. Despite the efficacy of TJA, postoperative complications, including aseptic prosthesis loosening and infections, are common. Moreover, the effects of individual genetic susceptibility and modifiable risk factors on these complications are unclear. This study analyzed these effects to enhance patient prognosis and postoperative management. Methods: We conducted an extensive genome-wide association study (GWAS) and Mendelian randomization (MR) study using UK Biobank data. The cohort included 2964 patients with mechanical complications post-TJA, 957 with periprosthetic joint infection (PJI), and a control group of 398,708 individuals. Genetic loci associated with postoperative complications were identified by a GWAS analysis, and the causal relationships of 11 modifiable risk factors with complications were assessed using MR. Results: The GWAS analysis identified nine loci associated with post-TJA complications. Two loci near the PPP1R3B and RBM26 genes were significantly linked to mechanical complications and PJI, respectively. The MR analysis demonstrated that body mass index was positively associated with the risk of mechanical complications (odds ratio [OR]: 1.42; p < 0.001). Higher educational attainment was associated with a decreased risk of mechanical complications (OR: 0.55; p < 0.001) and PJI (OR: 0.43; p = 0.001). Type 2 diabetes was suggestively associated with mechanical complications (OR, 1.18, p = 0.02), and hypertension was suggestively associated with PJI (OR, 1.41, p = 0.008). Other lifestyle factors, including smoking and alcohol consumption, were not causally related to postoperative complications. Conclusions: The genetic loci near PPP1R3B and RBM26 influenced the risk of post-TJA mechanical complications and infections, respectively. The effects of genetic and modifiable risk factors, including body mass index and educational attainment, underscore the need to perform personalized preoperative assessments and the postoperative management of surgical patients. These results indicate that integrating genetic screening and lifestyle interventions into patient care can improve the outcomes of TJA and patient quality of life.

4.
Front Bioeng Biotechnol ; 12: 1437684, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39170062

RESUMO

Introduction: The biomechanical indication for combining anterolateral structures reconstruction (ASLR) with ACL reconstruction (ACLR) to reduce pivot shift in the knee remains unclear. This study aims to investigate knee functionality after ACL rupture with different combinations of injuries, and to compare the effectiveness of ALSR with ACLR for treating these injuries. Methods: A validated finite element model of a human cadaveric knee was used to simulate pivot shift tests on the joint in different states, including 1) an intact knee; 2) after isolated ACL rupture; 3) after ACL rupture combined with different knee injuries or defect, including a posterior tibial slope (PTS) of 20°, an injury to the anterolateral structures (ALS) and an injury to the posterior meniscotibial ligament of the lateral meniscus (LP); 4) after treating the different injuries using isolated ACLR; v. after treating the different injuries using ACLR with ALSR. The knee kinematics, maximum von Mises stress (Max.S) on the tibial articular cartilage (TC) and force in the ACL graft were compared among the different simulation groups. Results and discussion: Comparing with isolated ACL rupture, combined injury to the ALS caused the largest knee laxity, when a combined PTS of 20° induced the largest Max.S on the TC. The joint stability and Max.S on the TC in the knee with an isolated ACL rupture or a combined rupture of ACL and LP were restored to the intact level after being treated with isolated ACLR. The knee biomechanics after a combined rupture of ACL and ALS were restored to the intact level only when being treated with a combination of ACLR and ALSR using a large graft diameter (6 mm) for ALSR. However, for the knee after ACL rupture combined with a PTS of 20°, the ATT and Max.S on the TC were still greater than the intact knee even after being treated with a combination of ACLR and ALSR. The finite element analysis showed that ACLR should include ALSR when treating ACL ruptures accompanied by ALS rupture. However, pivot shift in knees with a PTS of 20° was not eliminated even after a combined ACLR and ALSR.

5.
Global Spine J ; : 21925682241270090, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-39078998

RESUMO

STUDY DESIGN: Biomechanical testings and finite element analysis. OBJECTIVES: This study aims to investigate how annulus fibrosus (AF) incision size (RIS, Ratio of incision width to AF height) and shape affect intervertebral disc (IVD) biomechanics. METHODS: A validated finite element model of lumbar spines simulated various incisions in the middle-right posterior region of the AF, with different sizes and shapes. Simulations included axial compression, flexion, extension, bending, and rotation. Parameters assessed included stability, re-herniation, and IVD degeneration by analyzing stress, height, Intradiscal pressure (IDP), and the range of motion (ROM). RESULTS: Incision increased AF stress and ROM under 3 Nm moment, with values rising as RIS increased. RIS exceeding 40% resulted in a 20% AF stress increase during compression and extension, while RIS over 50% led to over 20% AF stress increase during other motions. Incision stress also increased with higher RIS, particularly surpassing 50% RIS. IDP rose across all incision shapes. Endplate stress increased (9.9%-48.9%) with larger incisions, with average increases of 12.8%, 12.7%, 30.5%, and 22.8% for circular, oval, square, and rectangular incisions. Compression and rotation minimally affected NP pressure (<15%), while flexion (19.8%-38.8%) and bending (18.5%-43.9%) had a more pronounced effect. ROM increased with RIS (20.0% ∼ 77.4%), especially with an incision RIS exceeding 40%. CONCLUSIONS: AF injury elevates AF stress, reduces spine stability, heightens degeneration risk with increasing RIS. Reherniation risk rises when RIS exceeds 40%. Circular or oval incisions maintain spine biomechanics better than square or rectangular ones.

6.
J Arthroplasty ; 39(10): 2547-2554, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38851406

RESUMO

BACKGROUND: The present study aimed to identify the risk factors of periprosthetic femoral fracture (PFF) after cementless total hip arthroplasty and rank them based on importance. METHODS: The age, sex, body mass index (BMI), osteoporosis, canal flare index (CFI), canal bone ratio (CBR), canal calcar ratio (CCR), stem design, and stem canal fill ratio (P1, P2, P3, and P4) of the proximal femoral medullary cavity of 111 total hip arthroplasty patients who had PFF and 388 who did not have PFF were analyzed. Independent-samples student t-tests were used for continuous variables, and Chi-square tests were used for categorical variables. The importance rankings of influencing factors were assessed using a random forest algorithm. Dimensionally reduced variables were then incorporated into a binary logistic regression model to determine the PFF-related risk factors. RESULTS: The mean age, BMI, CBR, CCR, and incidence of osteoporosis were higher in cases of PFF (all P < .001), while the mean CFI, P1, P2, P3, and P4 were lower in cases of PFF (P < .001, P = .033, P = .008, P < .001, and P < .001, respectively). Additionally, the stem design was also statistically associated with PFF (P < .001). Multivariate logistic regression revealed that advanced age, higher BMI, osteoporosis, stem design, lower CFI, higher CBR, higher CCR, lower P1, lower P2, lower P3, and lower P4 were the risk factors of PFF (P < .001, P < .001, P < .001, P < .001, P < .001, P = .010, P < .001, P = .002, P < .001, P < .001, and P = .007, respectively). The ranked importance of the risk factors for PFF was P3, CFI, osteoporosis, CBR, age, P4, P1, stem design, CCR, BMI, and P2. CONCLUSIONS: Lower P3, lower CFI, osteoporosis, higher CBR, advanced age, lower P4, lower P1, stem design, higher CCR, higher BMI, and lower P2 increased the risk of PFF.


Assuntos
Artroplastia de Quadril , Fraturas do Fêmur , Prótese de Quadril , Fraturas Periprotéticas , Humanos , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/instrumentação , Feminino , Masculino , Fraturas Periprotéticas/etiologia , Fraturas Periprotéticas/epidemiologia , Fatores de Risco , Pessoa de Meia-Idade , Idoso , Fraturas do Fêmur/etiologia , Fraturas do Fêmur/cirurgia , Prótese de Quadril/efeitos adversos , Osteoporose/etiologia , Índice de Massa Corporal , Estudos Retrospectivos , Adulto , Idoso de 80 Anos ou mais , Fatores Etários , Fêmur/cirurgia , Desenho de Prótese
7.
Spine J ; 24(10): 2002-2012, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38914373

RESUMO

BACKGROUND CONTEXT: Large annulus fibrosus (AF) defects often lead to a high rate of reherniation, particularly in the medial AF region, which has limited self-healing capabilities. The increasing prevalence of herniated discs underscores the need for effective repair strategies. PURPOSE: The objectives of this study were to design an AF repair technique to reduce solve the current problems of insufficient mechanical properties and poor sealing capacity. STUDY DESIGN: In vitro biomechanical experiments and finite element analysis. METHODS: The materials used in this study were patches and hydrogels with good biocompatibility and sufficient mechanical properties to withstand loading in the lumbar spine. Five repair techniques were assessed in this study: hydrogel filler (HF), AF patch medial barrier (MB), AF patch medial barrier and hydrogel filler (MB&HF), AF patch medial-lateral barrier (MLB), and AF patch medial-lateral barrier and hydrogel filler (MLB&HF). The repair techniques were subjected to in vitro testing (400 N axial compression and 0-500 N fatigue loading at 5Hz) and finite element analysis (400 N axial compression) to evaluate the effectiveness at repairing large AF defects. The evaluation included repair tightness, spinal stability, and fatigue resistance. RESULTS: From the in vitro testing, the failure load of the repair techniques was in the following order HF MLB >MB&HF >MLB&HF. CONCLUSIONS: The combined use of patches and hydrogels exhibited promising mechanical properties postdiscectomy, providing a promising solution for addressing large AF defects and improving disc stability. CLINICAL SIGNIFICANCE: This study introduces a promising method for repairing large annular fissure (AF) defects after disc herniation, combining patch repair with a hydrogel filler. These techniques hold potential for developing clinical AF repair products to address this challenging issue.


Assuntos
Anel Fibroso , Hidrogéis , Deslocamento do Disco Intervertebral , Anel Fibroso/cirurgia , Deslocamento do Disco Intervertebral/cirurgia , Hidrogéis/administração & dosagem , Humanos , Análise de Elementos Finitos , Fenômenos Biomecânicos , Recidiva , Animais , Vértebras Lombares/cirurgia
8.
Front Bioeng Biotechnol ; 12: 1386401, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38751867

RESUMO

Background: Injury to the lateral collateral ligament of the ankle may cause ankle instability and, when combined with deltoid ligament (DL) injury, may lead to a more complex situation known as rotational ankle instability (RAI). It is unclear how DL rupture interferes with the mechanical function of an ankle joint with RAI. Purpose: To study the influence of DL injury on the biomechanical function of the ankle joint. Methods: A comprehensive finite element model of an ankle joint, incorporating detailed ligaments, was developed from MRI scans of an adult female. A range of ligament injury scenarios were simulated in the ankle joint model, which was then subjected to a static standing load of 300 N and a 1.5 Nm internal and external rotation torque. The analysis focused on comparing the distribution and peak values of von Mises stress in the articular cartilages of both the tibia and talus and measuring the talus rotation angle and contact area of the talocrural joint. Results: The dimensions and location of insertion points of ligaments in the finite element ankle model were adopted from previous anatomical research and dissection studies. The anterior drawer distance in the finite element model was within 6.5% of the anatomical range, and the talus tilt angle was within 3% of anatomical results. During static standing, a combined rupture of the anterior talofibular ligament (ATFL) and anterior tibiotalar ligament (ATTL) generates new stress concentrations on the talus cartilage, which markedly increases the joint contact area and stress on the cartilage. During static standing with external rotation, the anterior talofibular ligament and anterior tibiotalar ligament ruptured the ankle's rotational angle by 21.8% compared to an intact joint. In contrast, static standing with internal rotation led to a similar increase in stress and a nearly 2.5 times increase in the talus rotational angle. Conclusion: Injury to the DL altered the stress distribution in the tibiotalar joint and increased the talus rotation angle when subjected to a rotational torque, which may increase the risk of RAI. When treating RAI, it is essential to address not only multi-band DL injuries but also single-band deep DL injuries, especially those affecting the ATTL.

9.
Int J Comput Assist Radiol Surg ; 19(5): 961-970, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38430380

RESUMO

PURPOSE: Osteonecrosis of the femoral head (ONFH) is a severe bone disease that can progressively lead to hip dysfunction. Accurately segmenting the necrotic lesion helps in diagnosing and treating ONFH. This paper aims at enhancing deep learning models for necrosis segmentation. METHODS: Necrotic lesions of ONFH are confined to the femoral head. Considering this domain knowledge, we introduce a preprocessing procedure, termed the "subtracting-adding" strategy, which explicitly incorporates this domain knowledge into the downstream deep neural network input. This strategy first removes the voxels outside the predefined volume of interest to "subtract" irrelevant information, and then it concatenates the bone mask with raw data to "add" anatomical structure information. RESULTS: Each of the tested off-the-shelf networks performed better with the help of the "subtracting-adding" strategy. The dice similarity coefficients increased by 10.93%, 9.23%, 9.38% and 1.60% for FCN, HRNet, SegNet and UNet, respectively. The improvements in FCN and HRNet were statistically significant. CONCLUSIONS: The "subtracting-adding" strategy enhances the performance of general-purpose networks in necrotic lesion segmentation. This strategy is compatible with various semantic segmentation networks, alleviating the need to design task-specific models.


Assuntos
Necrose da Cabeça do Fêmur , Humanos , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Aprendizado Profundo , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/patologia , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos
10.
Tissue Eng Part B Rev ; 30(5): 545-558, 2024 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38323564

RESUMO

After tendon or ligament reconstruction, the interface between the hard bone and soft connective tissue is considerably weakened and is difficult to restore through healing. The tendon/ligament-bone interface is mechanically the weakest point under tensile loading and is often the source of various postoperative complications, such as bone resorption and graft laxity. A comprehensive understanding of the macro- and microfeatures of the native tendon/ligament-bone interface would be beneficial for developing strategies for regenerating the tissue. This article discusses the structural, biological, and mechanical features of the tendon/ligament-bone interfaces and how these can be affected by aging and loading conditions.


Assuntos
Osso e Ossos , Ligamentos , Tendões , Tendões/fisiologia , Humanos , Ligamentos/fisiologia , Osso e Ossos/fisiologia , Animais , Fenômenos Biomecânicos
11.
Comput Methods Programs Biomed ; 247: 108059, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38382305

RESUMO

BACKGROUND AND OBJECTIVE: Core decompression surgery is an effective treatment method for patients with pre-collapse osteonecrosis of the femoral head (ONFH). The treatment relies on accurately predrilling the wire into the necrotic lesion. However, the surgical planning of this drilling path remains unclear. This paper aims to develop a framework to automatically plan the drilling path and analyze its geometric parameters. METHODOLOGY: The proposed system consists of two stages. The first stage is to detect the key points. Besides the entry point and target point for the drilling path, the center of the femoral head (FH) and the boundary points of the necrotic lesion are also detected for the subsequent geometric analysis. In the second stage, the geometric parameters of the drilling path are analyzed, including the size of the necrotic lesion, the length from the entry point to the target point, the relative location between the FH center and the necrosis center, and the angular range of the drilling path in the anterior-posterior (AP) direction and superior-inferior (SI) direction. RESULTS: All of the drilling paths designed by the proposed system were considered successful, starting from the proximal subtrochanteric region, terminating at the center of the necrotic lesion, and remaining within the femoral neck. The relative coordinates of the centers of the femoral head and necrotic lesion were (-0.89,5.14,2.63) mm for the left femurs and (1.55,5.92,2.63) mm for the right femurs, on average. The angular range of the drilling path was 39.99±29.58 degrees in the SI direction and 46.18±40.73 degrees in the AP direction. CONCLUSION: This study develops a framework that allows for automatic planning and geometric analysis of the drilling path in core decompression surgery. The target point of the drilling path primarily resides in the lateral-anterior-superior region relative to the femoral head center. Surgeons and researchers can benefit from our unified framework while still maintaining the flexibility to adapt to variations in surgical cases.

12.
Front Bioeng Biotechnol ; 11: 1239637, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37840662

RESUMO

Background: Postoperative complications following total hip arthroplasty (THA) often require revision surgery. X-rays are usually used to detect such complications, but manually identifying the location of the problem and making an accurate assessment can be subjective and time-consuming. Therefore, in this study, we propose a multi-branch network to automatically detect postoperative complications on X-ray images. Methods: We developed a multi-branch network using ResNet as the backbone and two additional branches with a global feature stream and a channel feature stream for extracting features of interest. Additionally, inspired by our domain knowledge, we designed a multi-coefficient class-specific residual attention block to learn the correlations between different complications to improve the performance of the system. Results: Our proposed method achieved state-of-the-art (SOTA) performance in detecting multiple complications, with mean average precision (mAP) and F1 scores of 0.346 and 0.429, respectively. The network also showed excellent performance at identifying aseptic loosening, with recall and precision rates of 0.929 and 0.897, respectively. Ablation experiments were conducted on detecting multiple complications and single complications, as well as internal and external datasets, demonstrating the effectiveness of our proposed modules. Conclusion: Our deep learning method provides an accurate end-to-end solution for detecting postoperative complications following THA.

13.
Front Bioeng Biotechnol ; 11: 1148914, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064225

RESUMO

Component alignment is one of the most crucial factors affecting total knee arthroplasty's clinical outcome and survival. This study aimed to investigate how coronal, sagittal, and transverse malalignment affects the mechanical behavior of the tibial insert and to determine a suitable alignment tolerance on the coronal, sagittal, and transverse planes. A finite element model of a cruciate-retaining knee prosthesis was assembled with different joint alignments (-10°, -7°, -5°, -3°, 0°, 3°, 5°, 7°, 10°) to assess the effect of malalignment under gait loading. The results showed that varus or valgus, extension, internal rotation, and excessive external rotation malalignments increased the maximum Von Mises stress and contact pressure on the tibial insert. The mechanical alignment tolerance of the studied prosthesis on the coronal, sagittal, and transverse planes was 3° varus to 3° valgus, 0°-10° flexion, and 0°-5° external rotation, respectively. This study suggests that each prosthesis should include a tolerance range for the joint alignment angle on the three planes, which may be used during surgical planning.

14.
Front Surg ; 10: 1112147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36733891

RESUMO

Background: Component alignment is a crucial factor affecting the clinical outcome of total knee arthroplasty (TKA). Accelerometer-based navigation (ABN) systems were developed to improve the accuracy of alignment during surgery. This study aimed to compare differences in component alignment, clinical outcomes, and surgical duration when using conventional instrumentation (CONI), ABN, and computer navigation (CN) systems. Methods: A comprehensive literature search was carried out using the Web of Science, Embase, PubMed, and Cochrane databases. Articles that met the eligibility criteria were included in the study. Meta-analyses were performed using the Cochrane Collaboration Review Manager based on Cochrane Review Method. The variables used for the analyses were postoperative clinical outcome (PCO), surgical duration, and component alignment, including the hip-knee-ankle (HKA) angle, coronal femoral angle (CFA), coronal tibial angle (CTA), sagittal femoral angle (SFA), sagittal tibial angle (STA), and the outliers for the mentioned angles. The mean difference (MD) was calculated to determine the difference between the surgical techniques for continuous variables and the odds ratio (OR) was used for the dichotomous outcomes. Results: The meta-analysis of the CONI and ABN system included 18 studies involving 2,070 TKA procedures, while the comparison of the ABN and CN systems included 5 studies involving 478 TKA procedures. The results showed that the ABN system provided more accurate component alignment for HKA, CFA, CTA, and SFA and produced fewer outliers for HKA, CFA, CTA, and STA. However, while the ABN system also required a significantly longer surgical time than the CONI approach, there was no statistical difference in PCO for the two systems. For the ABN and CN systems, there was no statistical difference in all variables except for the ABN system having a significantly shorter surgical duration. Conclusion: There was no significant difference in the accuracy of component alignment between the ABN and CN systems, but the ABN approach had a shorter surgical duration and at lower cost. The ABN system also significantly improved the accuracy of component alignment when compared to the CONI approach, although the surgery was longer. However, there was no significant difference in PCO between the CONI, ABN, and CN systems.

15.
Front Bioeng Biotechnol ; 11: 1104015, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845190

RESUMO

Objective: The purpose of this study was to analyze the feasibility of repairing a ruptured intervertebral disc using a patch secured to the inner surface of the annulus fibrosus (AF). Different material properties and geometries for the patch were evaluated. Methods: Using finite element analysis, this study created a large box-shaped rupture in the posterior-lateral region of the AF and then repaired it with a circular and square inner patch. The elastic modulus of the patches ranged from 1 to 50 MPa to determine the effect on the nucleus pulposus (NP) pressure, vertical displacement, disc bulge, AF stress, segmental range of motion (ROM), patch stress, and suture stress. The results were compared against the intact spine to determine the most suitable shape and properties for the repair patch. Results: The intervertebral height and ROM of the repaired lumbar spine was similar to the intact spine and was independent of the patch material properties and geometry. The patches with a modulus of 2-3 MPa resulted in an NP pressure and AF stresses closest to the healthy disc, and produced minimal contact pressure on the cleft surfaces and minimal stress on the suture and patch of all models. Circular patches caused lower NP pressure, AF stress and patch stress than the square patch, but also caused greater stress on the suture. Conclusion: A circular patch with an elastic modulus of 2-3 MPa secured to the inner region of the ruptured annulus fibrosus was able to immediately close the rupture and maintain an NP pressure and AF stress similar to the intact intervertebral disc. This patch had the lowest risk of complications and produced the greatest restorative effect of all patches simulated in this study.

16.
Front Vet Sci ; 10: 1115068, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36846264

RESUMO

Introduction: Knowledge of the morphological features of the anterior cruciate ligament (ACL) is critical for accurate reconstruction of it. This study aimed to explore the quantitative correlations among different morphological features of the ACL, thus to provide useful information for improving anatomical reconstruction techniques and designing artificial ligaments. Methods: 19 porcine knees were fixed at full extension using 10% formalin and were dissected to expose the ACL. ACL lengths were measured using a caliper. Mid-substances of the ACL were cut and scanned using X-ray microscopy, and the cross-sectional area (CSA) was measured at the isthmus. Margins of direct and indirect bone insertion sites were distinguished and marked. Measurements were performed on digital photographs to obtain the areas of bone insertions. Statistical analysis using nonlinear regression was used to identify potential correlations among the measurements. Results: The results showed that the CSA at the isthmus was significantly correlated with the total area of the bone insertion sites and the area of tibial insertion. The area of the tibial insertion was significantly correlated with the area of its direct insertion site. In contrast, the area of the femoral insertion was significantly correlated with the area of its indirect insertion site. The area of the indirect tibial insertion showed a weak correlation with the length of ACL, whereas the length of the ACL was not able to predict or be predicted by any other parameters. Conclusions: The CSA at the ACL isthmus is more representative for assessing the size of the ACL. However, ACL length has little correlation with the CSA of the isthmus or bone insertion sites, and thus should be evaluated independently for ACL reconstruction.

17.
J Mech Behav Biomed Mater ; 138: 105645, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36603526

RESUMO

Locking compression plates (LCP) with asymmetrical holes and polyaxial screws are effective for treating mid-femoral fractures, but are prone to failure in cases of bone nonunion. To understand the failure mechanism of the LCP, this study assessed the material composition, microhardness, metallography, fractography and biomechanical performance of a retrieved LCP used for treating a bone fracture of AO type 32-A1. For the biomechanical assessment, a finite element surgical model implanted with the intact fixation-plate system was constructed to understand the stresses and structural stiffness on the construct. Also, to avoid positioning screws around the bone fracture, different working lengths of the plate (the distance between the two innermost screws) and screw inclinations (±5°, ±10° and ±15°) were investigated. The fracture site of the retrieved LCP was divided into a narrow side and broad side due to the asymmetrical distribution of holes on the plate. The results indicated that the chemical composition and microhardness of the LCP complied with ASTM standards. The fatigue failure was found to originate on the narrow side of the hole, while the broad side showed overloading characteristics of crack growth. When the screws were inserted away from the region of the bone fracture by increasing the working length, the stress of the fixation-plate system decreased. Regardless of the screw insertion angle, the maximum stress on the LCP always appeared on the narrow side, and there was little change in the structural stiffness. However, angling the screws at -10° resulted in the most even stress distribution on the fixation-plate system. In conclusion, the LCP assessed in this study failed by fatigue fracture due to bone nonunion and stress concentration. The narrow side of the LCP was vulnerable to failure and needs to be strengthened. When treating an AO type 32-A1 fracture using an LCP with asymmetrical holes and polyaxial screws, inserting the screws at -10° may reduce the risk of implant failure and positing screws around the fractured area of the bone should be avoided.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Humanos , Fixação Interna de Fraturas/métodos , Placas Ósseas , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Falha de Equipamento , Fenômenos Biomecânicos
18.
J Orthop Translat ; 38: 220-228, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36474854

RESUMO

Background: Stress shielding â€‹(SS) is considered the main mechanical cause of femoral stem loosening after total hip arthroplasty (THA). This study introduces an auxetic lattice femoral stem structure with negative Poisson's ratio that can expand laterally, with the intent of transferring more load to surrounding bone and thereby reducing SS. This study aims to evaluate how the geometry profile of different femoral stems with auxetic structures affects the level of SS. Different re-entrant angles for the auxetic unit cells were also evaluated. Methods: This study assessed three commercial femoral stem designs (Mayo, CLS and Fitmore) and three re-entrant angles for the auxetic structures (60°, 70° and 80°). Nine auxetic femoral stems (three M-type, three C-type and three F-type) and three solid femoral stems (control group) were designed. All femoral stems were implanted into a finite element model of the human femur to compare levels of SS between the auxetic stems and their traditional solid counterparts. Results: The results showed that incorporating an auxetic structure into the stem design caused less SS of the surrounding bone than the control models. The M-type stems had the lowest level of SS, followed by the C-type and F-type stems. A re-entrant angle of 70° for the M-type stem, 80° for the C-type stem and 60° for the F-type stem were the designs most capable of reducing SS. Conclusions: This study found that femoral stems with an auxetic lattice structure caused less SS after THA than comparable solid femoral stems. A femoral stem based on the M-type geometry profile is recommended when designing auxetic femoral stems to minimize SS of surrounding bone. The translational potential of this article: The novel solution provided in this study may serve to increase the survival rate of femoral stems by reducing SS after THA.

19.
Front Vet Sci ; 9: 1045785, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36467640

RESUMO

Introduction: Pigs are widely used for clinical research on the anterior cruciate ligament (ACL) because of the similarity of the knee structure to the human knee. But evidence to support the suitability of using porcine samples to guide clinical practices is limited. This study aims to explore the qualitative and quantitative morphological features of the porcine knee and ACL, and to compare these with data on humans reported in literature. Methods: Nineteen porcine knees were used for this study. The bone structures were measured on coronal X-ray images. The length of the ACL was measured using a caliper. The ACL bone insertion sites were marked and measured on a digital photograph. The lengths of the long and short axis of the ACL isthmus were measured on the X-ray microscopy reconstructed images. The outcomes were compared with previously reported data on humans using an abstract independent-samples T test. Results: Qualitative observation indicated a similar location, orientation and general morphology of the porcine ACL to human ACLs. The major difference was the location of the ACL tibial insertion with respect to the anterior horn of the lateral meniscus (AHLM). The porcine ACL was split into AM and PL bundles by the AHLM, while the AHLM was adjacent to the anterolateral border of the ACL tibial insertion in human knees. The quantitative comparison showed no significant difference between the human and porcine ACL in terms of the length of the ACL, the width of the femoral condyle and tibial plateau, and the tibial interspinal width. However, the CSA, the lengths of the long and short axis of the ACL isthmus, and the femoral and tibial insertion areas of the porcine ACL were all significantly larger than the reported features in human knees. Conclusion: The location, orientation and basic morphology of the porcine ACL and knee are similar to humans. However, the two-bundle structure is more distinct in a porcine ACL, and the dimensions of the porcine ACL are generally larger. This study may provide useful information to researchers when assessing the feasibility and limitations of using porcine samples for research on the human ACL and knee.

20.
Polymers (Basel) ; 14(23)2022 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-36501675

RESUMO

The wear of the tibial insert is one of the primary factors leading to the failure of total knee arthroplasty. As materials age, their wear performance often degrades. Supplementing highly cross-linked polyethylene (HXLPE) with dodecyl gallate (DG) can improve the oxidation stability of tibial inserts for use in total knee arthroplasty (TKA). This study aimed to evaluate the wear resistance of HXLPE supplemented with DG (HXLPE-DG) tibial inserts before and after accelerated aging. HXLPE-DG tibial inserts were subjected to wear testing of up to 5 million loading cycles according to ISO 14243, and the resulting wear particles were analyzed according to ISO 17853. The wear rate, number, size, and shape of the wear particles were analyzed. The average wear rate of the unaged samples was 4.39 ± 0.75 mg/million cycles and was 3.22 ± 1.49 mg/million cycles for the aged samples. The unaged tibial inserts generated about 2.80 × 107 particles/mL following the wear test, but this was considerably lower for the aged samples at about 1.35 × 107 particles/mL. The average equivalent circle diameter (ECD) of the wear particles from the unaged samples was 0.13 µm (max: 0.80 µm; min: 0.04 µm), and it was 0.14 µm (max: 0.66 µm; min: 0.06 µm) from the aged samples. Moreover, 22.1% of the wear particles from the unaged samples had an aspect ratio (AR) of >4 (slender shape), while this was 15.4% for the aged samples. HXLPE-DG improves the wear performance of the material over time. HXLPE-DG is a novel material that has been demonstrated to have antiaging properties and high wear resistance, making it a promising candidate for use in TKA. Nevertheless, the results are preliminary and will be clarified in further studies.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA