Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 159
Filtrar
1.
J Arthroplasty ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38851406

RESUMO

BACKGROUND: The present study aimed to identify the risk factors of periprosthetic femoral fracture (PFF) after cementless total hip arthroplasty (THA) and rank them based on importance. METHODS: The age, sex, body mass index (BMI), osteoporosis, canal flare index (CFI), canal bone ratio (CBR), canal calcar ratio (CCR), stem design, and stem canal fill ratio (P1, P2, P3, and P4) of the proximal femoral medullary cavity of 111 THA patients who had PFF and 388 who did not have PFF were analyzed. Independent-samples student t-tests were used for continuous variables, and Chi-square tests were used for categorical variables. The importance rankings of influencing factors were assessed using a random forest algorithm. Dimensionally reduced variables were then incorporated into a binary logistic regression model to determine the PFF-related risk factors. RESULTS: The mean age, BMI, CBR, CCR, and incidence of osteoporosis were higher in cases of PFF (all P < 0.001), while the mean CFI, P1, P2, P3, and P4 were lower in cases of PFF (P < 0.001, P = 0.033, P = 0.008, P < 0.001, and P < 0.001, respectively). Additionally, the stem design was also statistically associated with PFF (P < 0.001). Multivariate logistic regression revealed that advanced age, higher BMI, osteoporosis, stem design, lower CFI, higher CBR, higher CCR, lower P1, lower P2, lower P3, and lower P4 were the risk factors of PFF (P < 0.001, P < 0.001, P < 0.001, P < 0.001, P < 0.001, P = 0.010, P < 0.001, P = 0.002, P < 0.001, P < 0.001, and P = 0.007, respectively). The ranked importance of the risk factors for PFF was P3, CFI, osteoporosis, CBR, age, P4, P1, stem design, CCR, BMI, and P2. CONCLUSION: Lower P3, lower CFI, osteoporosis, higher CBR, advanced age, lower P4, lower P1, stem design, higher CCR, higher BMI, and lower P2 increased the risk of PFF.

2.
Spine J ; 2024 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-38914373

RESUMO

BACKGROUND CONTEXT: Large annulus fibrosus (AF) defects often lead to a high rate of reherniation, particularly in the medial AF region, which has limited self-healing capabilities. The increasing prevalence of herniated discs underscores the need for effective repair strategies. PURPOSE: The objectives of this study were to design an AF repair technique to reduce solve the current problems of insufficient mechanical properties and poor sealing capacity. STUDY DESIGN: In vitro biomechanical experiments and finite element analysis. METHODS: The materials used in this study were patches and hydrogels with good biocompatibility and sufficient mechanical properties to withstand loading in the lumbar spine. Five repair techniques were assessed in this study: hydrogel filler (HF), AF patch medial barrier (MB), AF patch medial barrier and hydrogel filler (MB&HF), AF patch medial-lateral barrier (MLB), and AF patch medial-lateral barrier and hydrogel filler (MLB&HF). The repair techniques were subjected to in vitro testing (400 N axial compression and 0-500 N fatigue loading at 5Hz) and finite element analysis (400 N axial compression) to evaluate the effectiveness at repairing large AF defects. The evaluation included repair tightness, spinal stability, and fatigue resistance. RESULTS: From the in vitro testing, the failure load of the repair techniques was in the following order HF < MB < MB&HF < MLB < MLB&HF. Both HF and MB groups failed to effectively increase intervertebral disc (IVD) stiffness, resulting in a reduction in spatial stability. The MLB, MB&HF, and MLB&HF groups partially restored IVD stiffness, with MLB&HF showing the most effective recovery (-24.13% ± 3.59%). From the finite element models, incorporating a hydrogel filler was best able to maintain the IVD height. Patch repair alone could not adequately reduce the high AF stress due to AF injury, but with hydrogel support, stress was substantially low and more uniformly distributed. All repair techniques demonstrated reduced stress around the damaged area on the AF, in comparison to the unrepaired model. The NP pressure in the HF group was closest to the intact group, and the patch repair reduced the NP pressure. The maximum patch deformation and suture stress were ranked as MB > MLB > MB&HF > MLB&HF. CONCLUSIONS: The combined use of patches and hydrogels exhibited promising mechanical properties post-discectomy, providing a promising solution for addressing large AF defects and improving disc stability. CLINICAL SIGNIFICANCE: This study introduces a promising method for repairing large annular fissure (AF) defects after disc herniation, combining patch repair with a hydrogel filler. These techniques hold potential for developing clinical AF repair products to address this challenging issue.

3.
Front Bioeng Biotechnol ; 12: 1386401, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38751867

RESUMO

Background: Injury to the lateral collateral ligament of the ankle may cause ankle instability and, when combined with deltoid ligament (DL) injury, may lead to a more complex situation known as rotational ankle instability (RAI). It is unclear how DL rupture interferes with the mechanical function of an ankle joint with RAI. Purpose: To study the influence of DL injury on the biomechanical function of the ankle joint. Methods: A comprehensive finite element model of an ankle joint, incorporating detailed ligaments, was developed from MRI scans of an adult female. A range of ligament injury scenarios were simulated in the ankle joint model, which was then subjected to a static standing load of 300 N and a 1.5 Nm internal and external rotation torque. The analysis focused on comparing the distribution and peak values of von Mises stress in the articular cartilages of both the tibia and talus and measuring the talus rotation angle and contact area of the talocrural joint. Results: The dimensions and location of insertion points of ligaments in the finite element ankle model were adopted from previous anatomical research and dissection studies. The anterior drawer distance in the finite element model was within 6.5% of the anatomical range, and the talus tilt angle was within 3% of anatomical results. During static standing, a combined rupture of the anterior talofibular ligament (ATFL) and anterior tibiotalar ligament (ATTL) generates new stress concentrations on the talus cartilage, which markedly increases the joint contact area and stress on the cartilage. During static standing with external rotation, the anterior talofibular ligament and anterior tibiotalar ligament ruptured the ankle's rotational angle by 21.8% compared to an intact joint. In contrast, static standing with internal rotation led to a similar increase in stress and a nearly 2.5 times increase in the talus rotational angle. Conclusion: Injury to the DL altered the stress distribution in the tibiotalar joint and increased the talus rotation angle when subjected to a rotational torque, which may increase the risk of RAI. When treating RAI, it is essential to address not only multi-band DL injuries but also single-band deep DL injuries, especially those affecting the ATTL.

4.
Int J Comput Assist Radiol Surg ; 19(5): 961-970, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38430380

RESUMO

PURPOSE: Osteonecrosis of the femoral head (ONFH) is a severe bone disease that can progressively lead to hip dysfunction. Accurately segmenting the necrotic lesion helps in diagnosing and treating ONFH. This paper aims at enhancing deep learning models for necrosis segmentation. METHODS: Necrotic lesions of ONFH are confined to the femoral head. Considering this domain knowledge, we introduce a preprocessing procedure, termed the "subtracting-adding" strategy, which explicitly incorporates this domain knowledge into the downstream deep neural network input. This strategy first removes the voxels outside the predefined volume of interest to "subtract" irrelevant information, and then it concatenates the bone mask with raw data to "add" anatomical structure information. RESULTS: Each of the tested off-the-shelf networks performed better with the help of the "subtracting-adding" strategy. The dice similarity coefficients increased by 10.93%, 9.23%, 9.38% and 1.60% for FCN, HRNet, SegNet and UNet, respectively. The improvements in FCN and HRNet were statistically significant. CONCLUSIONS: The "subtracting-adding" strategy enhances the performance of general-purpose networks in necrotic lesion segmentation. This strategy is compatible with various semantic segmentation networks, alleviating the need to design task-specific models.


Assuntos
Necrose da Cabeça do Fêmur , Humanos , Necrose da Cabeça do Fêmur/diagnóstico por imagem , Aprendizado Profundo , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Cabeça do Fêmur/diagnóstico por imagem , Cabeça do Fêmur/patologia , Masculino , Feminino , Imageamento por Ressonância Magnética/métodos
5.
Artigo em Inglês | MEDLINE | ID: mdl-38323564

RESUMO

After tendon or ligament reconstruction, the interface between the hard bone and soft connective tissue is considerably weakened and is difficult to restore through healing. The tendon/ligament-bone interface is mechanically the weakest point under tensile loading and is often the source of various postoperative complications, such as bone resorption and graft laxity. A comprehensive understanding of the macro- and microfeatures of the native tendon/ligament-bone interface would be beneficial for developing strategies for regenerating the tissue. This article discusses the structural, biological, and mechanical features of the tendon/ligament-bone interfaces and how these can be affected by aging and loading conditions.

6.
Comput Methods Programs Biomed ; 247: 108059, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38382305

RESUMO

BACKGROUND AND OBJECTIVE: Core decompression surgery is an effective treatment method for patients with pre-collapse osteonecrosis of the femoral head (ONFH). The treatment relies on accurately predrilling the wire into the necrotic lesion. However, the surgical planning of this drilling path remains unclear. This paper aims to develop a framework to automatically plan the drilling path and analyze its geometric parameters. METHODOLOGY: The proposed system consists of two stages. The first stage is to detect the key points. Besides the entry point and target point for the drilling path, the center of the femoral head (FH) and the boundary points of the necrotic lesion are also detected for the subsequent geometric analysis. In the second stage, the geometric parameters of the drilling path are analyzed, including the size of the necrotic lesion, the length from the entry point to the target point, the relative location between the FH center and the necrosis center, and the angular range of the drilling path in the anterior-posterior (AP) direction and superior-inferior (SI) direction. RESULTS: All of the drilling paths designed by the proposed system were considered successful, starting from the proximal subtrochanteric region, terminating at the center of the necrotic lesion, and remaining within the femoral neck. The relative coordinates of the centers of the femoral head and necrotic lesion were (-0.89,5.14,2.63) mm for the left femurs and (1.55,5.92,2.63) mm for the right femurs, on average. The angular range of the drilling path was 39.99±29.58 degrees in the SI direction and 46.18±40.73 degrees in the AP direction. CONCLUSION: This study develops a framework that allows for automatic planning and geometric analysis of the drilling path in core decompression surgery. The target point of the drilling path primarily resides in the lateral-anterior-superior region relative to the femoral head center. Surgeons and researchers can benefit from our unified framework while still maintaining the flexibility to adapt to variations in surgical cases.

7.
Front Bioeng Biotechnol ; 11: 1239637, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37840662

RESUMO

Background: Postoperative complications following total hip arthroplasty (THA) often require revision surgery. X-rays are usually used to detect such complications, but manually identifying the location of the problem and making an accurate assessment can be subjective and time-consuming. Therefore, in this study, we propose a multi-branch network to automatically detect postoperative complications on X-ray images. Methods: We developed a multi-branch network using ResNet as the backbone and two additional branches with a global feature stream and a channel feature stream for extracting features of interest. Additionally, inspired by our domain knowledge, we designed a multi-coefficient class-specific residual attention block to learn the correlations between different complications to improve the performance of the system. Results: Our proposed method achieved state-of-the-art (SOTA) performance in detecting multiple complications, with mean average precision (mAP) and F1 scores of 0.346 and 0.429, respectively. The network also showed excellent performance at identifying aseptic loosening, with recall and precision rates of 0.929 and 0.897, respectively. Ablation experiments were conducted on detecting multiple complications and single complications, as well as internal and external datasets, demonstrating the effectiveness of our proposed modules. Conclusion: Our deep learning method provides an accurate end-to-end solution for detecting postoperative complications following THA.

8.
Front Bioeng Biotechnol ; 11: 1148914, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37064225

RESUMO

Component alignment is one of the most crucial factors affecting total knee arthroplasty's clinical outcome and survival. This study aimed to investigate how coronal, sagittal, and transverse malalignment affects the mechanical behavior of the tibial insert and to determine a suitable alignment tolerance on the coronal, sagittal, and transverse planes. A finite element model of a cruciate-retaining knee prosthesis was assembled with different joint alignments (-10°, -7°, -5°, -3°, 0°, 3°, 5°, 7°, 10°) to assess the effect of malalignment under gait loading. The results showed that varus or valgus, extension, internal rotation, and excessive external rotation malalignments increased the maximum Von Mises stress and contact pressure on the tibial insert. The mechanical alignment tolerance of the studied prosthesis on the coronal, sagittal, and transverse planes was 3° varus to 3° valgus, 0°-10° flexion, and 0°-5° external rotation, respectively. This study suggests that each prosthesis should include a tolerance range for the joint alignment angle on the three planes, which may be used during surgical planning.

9.
Front Bioeng Biotechnol ; 11: 1104015, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36845190

RESUMO

Objective: The purpose of this study was to analyze the feasibility of repairing a ruptured intervertebral disc using a patch secured to the inner surface of the annulus fibrosus (AF). Different material properties and geometries for the patch were evaluated. Methods: Using finite element analysis, this study created a large box-shaped rupture in the posterior-lateral region of the AF and then repaired it with a circular and square inner patch. The elastic modulus of the patches ranged from 1 to 50 MPa to determine the effect on the nucleus pulposus (NP) pressure, vertical displacement, disc bulge, AF stress, segmental range of motion (ROM), patch stress, and suture stress. The results were compared against the intact spine to determine the most suitable shape and properties for the repair patch. Results: The intervertebral height and ROM of the repaired lumbar spine was similar to the intact spine and was independent of the patch material properties and geometry. The patches with a modulus of 2-3 MPa resulted in an NP pressure and AF stresses closest to the healthy disc, and produced minimal contact pressure on the cleft surfaces and minimal stress on the suture and patch of all models. Circular patches caused lower NP pressure, AF stress and patch stress than the square patch, but also caused greater stress on the suture. Conclusion: A circular patch with an elastic modulus of 2-3 MPa secured to the inner region of the ruptured annulus fibrosus was able to immediately close the rupture and maintain an NP pressure and AF stress similar to the intact intervertebral disc. This patch had the lowest risk of complications and produced the greatest restorative effect of all patches simulated in this study.

10.
Front Vet Sci ; 10: 1115068, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36846264

RESUMO

Introduction: Knowledge of the morphological features of the anterior cruciate ligament (ACL) is critical for accurate reconstruction of it. This study aimed to explore the quantitative correlations among different morphological features of the ACL, thus to provide useful information for improving anatomical reconstruction techniques and designing artificial ligaments. Methods: 19 porcine knees were fixed at full extension using 10% formalin and were dissected to expose the ACL. ACL lengths were measured using a caliper. Mid-substances of the ACL were cut and scanned using X-ray microscopy, and the cross-sectional area (CSA) was measured at the isthmus. Margins of direct and indirect bone insertion sites were distinguished and marked. Measurements were performed on digital photographs to obtain the areas of bone insertions. Statistical analysis using nonlinear regression was used to identify potential correlations among the measurements. Results: The results showed that the CSA at the isthmus was significantly correlated with the total area of the bone insertion sites and the area of tibial insertion. The area of the tibial insertion was significantly correlated with the area of its direct insertion site. In contrast, the area of the femoral insertion was significantly correlated with the area of its indirect insertion site. The area of the indirect tibial insertion showed a weak correlation with the length of ACL, whereas the length of the ACL was not able to predict or be predicted by any other parameters. Conclusions: The CSA at the ACL isthmus is more representative for assessing the size of the ACL. However, ACL length has little correlation with the CSA of the isthmus or bone insertion sites, and thus should be evaluated independently for ACL reconstruction.

11.
Front Surg ; 10: 1112147, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36733891

RESUMO

Background: Component alignment is a crucial factor affecting the clinical outcome of total knee arthroplasty (TKA). Accelerometer-based navigation (ABN) systems were developed to improve the accuracy of alignment during surgery. This study aimed to compare differences in component alignment, clinical outcomes, and surgical duration when using conventional instrumentation (CONI), ABN, and computer navigation (CN) systems. Methods: A comprehensive literature search was carried out using the Web of Science, Embase, PubMed, and Cochrane databases. Articles that met the eligibility criteria were included in the study. Meta-analyses were performed using the Cochrane Collaboration Review Manager based on Cochrane Review Method. The variables used for the analyses were postoperative clinical outcome (PCO), surgical duration, and component alignment, including the hip-knee-ankle (HKA) angle, coronal femoral angle (CFA), coronal tibial angle (CTA), sagittal femoral angle (SFA), sagittal tibial angle (STA), and the outliers for the mentioned angles. The mean difference (MD) was calculated to determine the difference between the surgical techniques for continuous variables and the odds ratio (OR) was used for the dichotomous outcomes. Results: The meta-analysis of the CONI and ABN system included 18 studies involving 2,070 TKA procedures, while the comparison of the ABN and CN systems included 5 studies involving 478 TKA procedures. The results showed that the ABN system provided more accurate component alignment for HKA, CFA, CTA, and SFA and produced fewer outliers for HKA, CFA, CTA, and STA. However, while the ABN system also required a significantly longer surgical time than the CONI approach, there was no statistical difference in PCO for the two systems. For the ABN and CN systems, there was no statistical difference in all variables except for the ABN system having a significantly shorter surgical duration. Conclusion: There was no significant difference in the accuracy of component alignment between the ABN and CN systems, but the ABN approach had a shorter surgical duration and at lower cost. The ABN system also significantly improved the accuracy of component alignment when compared to the CONI approach, although the surgery was longer. However, there was no significant difference in PCO between the CONI, ABN, and CN systems.

12.
J Mech Behav Biomed Mater ; 138: 105645, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36603526

RESUMO

Locking compression plates (LCP) with asymmetrical holes and polyaxial screws are effective for treating mid-femoral fractures, but are prone to failure in cases of bone nonunion. To understand the failure mechanism of the LCP, this study assessed the material composition, microhardness, metallography, fractography and biomechanical performance of a retrieved LCP used for treating a bone fracture of AO type 32-A1. For the biomechanical assessment, a finite element surgical model implanted with the intact fixation-plate system was constructed to understand the stresses and structural stiffness on the construct. Also, to avoid positioning screws around the bone fracture, different working lengths of the plate (the distance between the two innermost screws) and screw inclinations (±5°, ±10° and ±15°) were investigated. The fracture site of the retrieved LCP was divided into a narrow side and broad side due to the asymmetrical distribution of holes on the plate. The results indicated that the chemical composition and microhardness of the LCP complied with ASTM standards. The fatigue failure was found to originate on the narrow side of the hole, while the broad side showed overloading characteristics of crack growth. When the screws were inserted away from the region of the bone fracture by increasing the working length, the stress of the fixation-plate system decreased. Regardless of the screw insertion angle, the maximum stress on the LCP always appeared on the narrow side, and there was little change in the structural stiffness. However, angling the screws at -10° resulted in the most even stress distribution on the fixation-plate system. In conclusion, the LCP assessed in this study failed by fatigue fracture due to bone nonunion and stress concentration. The narrow side of the LCP was vulnerable to failure and needs to be strengthened. When treating an AO type 32-A1 fracture using an LCP with asymmetrical holes and polyaxial screws, inserting the screws at -10° may reduce the risk of implant failure and positing screws around the fractured area of the bone should be avoided.


Assuntos
Fraturas do Fêmur , Fixação Interna de Fraturas , Humanos , Fixação Interna de Fraturas/métodos , Placas Ósseas , Parafusos Ósseos , Fraturas do Fêmur/cirurgia , Falha de Equipamento , Fenômenos Biomecânicos
13.
J Orthop Translat ; 38: 220-228, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36474854

RESUMO

Background: Stress shielding â€‹(SS) is considered the main mechanical cause of femoral stem loosening after total hip arthroplasty (THA). This study introduces an auxetic lattice femoral stem structure with negative Poisson's ratio that can expand laterally, with the intent of transferring more load to surrounding bone and thereby reducing SS. This study aims to evaluate how the geometry profile of different femoral stems with auxetic structures affects the level of SS. Different re-entrant angles for the auxetic unit cells were also evaluated. Methods: This study assessed three commercial femoral stem designs (Mayo, CLS and Fitmore) and three re-entrant angles for the auxetic structures (60°, 70° and 80°). Nine auxetic femoral stems (three M-type, three C-type and three F-type) and three solid femoral stems (control group) were designed. All femoral stems were implanted into a finite element model of the human femur to compare levels of SS between the auxetic stems and their traditional solid counterparts. Results: The results showed that incorporating an auxetic structure into the stem design caused less SS of the surrounding bone than the control models. The M-type stems had the lowest level of SS, followed by the C-type and F-type stems. A re-entrant angle of 70° for the M-type stem, 80° for the C-type stem and 60° for the F-type stem were the designs most capable of reducing SS. Conclusions: This study found that femoral stems with an auxetic lattice structure caused less SS after THA than comparable solid femoral stems. A femoral stem based on the M-type geometry profile is recommended when designing auxetic femoral stems to minimize SS of surrounding bone. The translational potential of this article: The novel solution provided in this study may serve to increase the survival rate of femoral stems by reducing SS after THA.

14.
Front Vet Sci ; 9: 1045785, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36467640

RESUMO

Introduction: Pigs are widely used for clinical research on the anterior cruciate ligament (ACL) because of the similarity of the knee structure to the human knee. But evidence to support the suitability of using porcine samples to guide clinical practices is limited. This study aims to explore the qualitative and quantitative morphological features of the porcine knee and ACL, and to compare these with data on humans reported in literature. Methods: Nineteen porcine knees were used for this study. The bone structures were measured on coronal X-ray images. The length of the ACL was measured using a caliper. The ACL bone insertion sites were marked and measured on a digital photograph. The lengths of the long and short axis of the ACL isthmus were measured on the X-ray microscopy reconstructed images. The outcomes were compared with previously reported data on humans using an abstract independent-samples T test. Results: Qualitative observation indicated a similar location, orientation and general morphology of the porcine ACL to human ACLs. The major difference was the location of the ACL tibial insertion with respect to the anterior horn of the lateral meniscus (AHLM). The porcine ACL was split into AM and PL bundles by the AHLM, while the AHLM was adjacent to the anterolateral border of the ACL tibial insertion in human knees. The quantitative comparison showed no significant difference between the human and porcine ACL in terms of the length of the ACL, the width of the femoral condyle and tibial plateau, and the tibial interspinal width. However, the CSA, the lengths of the long and short axis of the ACL isthmus, and the femoral and tibial insertion areas of the porcine ACL were all significantly larger than the reported features in human knees. Conclusion: The location, orientation and basic morphology of the porcine ACL and knee are similar to humans. However, the two-bundle structure is more distinct in a porcine ACL, and the dimensions of the porcine ACL are generally larger. This study may provide useful information to researchers when assessing the feasibility and limitations of using porcine samples for research on the human ACL and knee.

15.
Polymers (Basel) ; 14(23)2022 Dec 03.
Artigo em Inglês | MEDLINE | ID: mdl-36501675

RESUMO

The wear of the tibial insert is one of the primary factors leading to the failure of total knee arthroplasty. As materials age, their wear performance often degrades. Supplementing highly cross-linked polyethylene (HXLPE) with dodecyl gallate (DG) can improve the oxidation stability of tibial inserts for use in total knee arthroplasty (TKA). This study aimed to evaluate the wear resistance of HXLPE supplemented with DG (HXLPE-DG) tibial inserts before and after accelerated aging. HXLPE-DG tibial inserts were subjected to wear testing of up to 5 million loading cycles according to ISO 14243, and the resulting wear particles were analyzed according to ISO 17853. The wear rate, number, size, and shape of the wear particles were analyzed. The average wear rate of the unaged samples was 4.39 ± 0.75 mg/million cycles and was 3.22 ± 1.49 mg/million cycles for the aged samples. The unaged tibial inserts generated about 2.80 × 107 particles/mL following the wear test, but this was considerably lower for the aged samples at about 1.35 × 107 particles/mL. The average equivalent circle diameter (ECD) of the wear particles from the unaged samples was 0.13 µm (max: 0.80 µm; min: 0.04 µm), and it was 0.14 µm (max: 0.66 µm; min: 0.06 µm) from the aged samples. Moreover, 22.1% of the wear particles from the unaged samples had an aspect ratio (AR) of >4 (slender shape), while this was 15.4% for the aged samples. HXLPE-DG improves the wear performance of the material over time. HXLPE-DG is a novel material that has been demonstrated to have antiaging properties and high wear resistance, making it a promising candidate for use in TKA. Nevertheless, the results are preliminary and will be clarified in further studies.

16.
Front Surg ; 9: 991476, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36311927

RESUMO

Objective: This study aimed to investigate the correlation between component alignment and short-term clinical outcomes after total knee arthroplasty (TKA). Methods: 50 TKA patients from a regional hospital were enrolled in the study. The following component alignments were measured from radiological data acquired within 1 week after surgery: hip-knee-ankle angle (HKA), medial distal femoral angle (MDFA), medial proximal tibial angle (MPTA), femoral flexion-extension angle (FEA), tibial slope angle (TSA), femoral rotational angle (FRA) and tibial rotational angle (TRA). The Hospital for Special Surgery (HSS) knee scoring system was used to assess clinical outcomes after 1 year, with patients being divided into three groups (excellent, good and not good) according to the HSS scores. Difference analysis and linear correlation analysis were used for the statistical analysis. Results: The results showed significant differences in MDFA (p = 0.050) and FEA (p = 0.001) among the three patient groups. It was also found that the total HSS had only a moderate correlation with FEA (r = 0.572, p < 0.001), but FEA had a positive linear correlation with pain scores (r = 0.347, p = 0.013), function scores (r = 0.535, p = 0.000), ROM scores (r = 0.368, p = 0.009), muscle scores (r = 0.354, p = 0.012) and stability scores (r = 0.312, p = 0.028). A larger MDFA was associated with lower FE deformity scores (r = -0.289, p = 0.042) and the TSA had a positive influence on the ROM (r = 0.436, p = 0.002). Also, changes in FRA produced a consequent change in the FE deformity score (r = 0.312, p = 0.027), and the muscle strength scores increased as TRA increased (r = 0.402, p = 0.004). Conclusion: The results show that the FEA plays a significant role in clinical outcomes after TKA. Surgical techniques and tools may need to be improved to accurately adjust the FEA to improve joint functionality and patient satisfaction.

17.
Bioengineering (Basel) ; 9(10)2022 Sep 27.
Artigo em Inglês | MEDLINE | ID: mdl-36290477

RESUMO

The size of the anterior cruciate ligament (ACL) often varies between individuals, but such variation is not typically considered during ACL reconstruction (ACLR). This study aimed to explore how the size of the ACL affects the selection of a suitable graft diameter. A finite element model of a human knee was implanted with intact ACLs of different dimensions (0.95, 1 and 1.05 times the size of the original ACL) and with grafts of different diameters, to simulate ACLR (diameter 7.5-12 mm in 0.5 mm increments). The knee models were flexed to 30° and loaded with an anterior tibial load of 103 N, internal tibial moment of 7.5 Nm, and valgus tibial moment of 6.9 Nm. Knee kinematics (anterior tibial translation (ATT), internal tibial rotation (ITR) and valgus tibial rotation (VTR)) and ligament forces were recorded and compared among the different groups. The results showed that, compared with the intact knee, a graft diameter of 7.5 mm was found to increase the ATT and VTR, but reduce the graft force. Increasing the graft diameter reduced knee laxity and increased the graft force. A 10% increase in the size of the ACL corresponded to a 3 mm larger graft diameter required to restore knee stability and graft force after ACLR. It was concluded that the graft diameter should be selected according to the dimensions of the native ACL, for better restoration of knee functionality. This study may help to improve the clinical treatment of ACL ruptures.

18.
Front Bioeng Biotechnol ; 10: 910311, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35910010

RESUMO

This study aimed to investigate the influence of tibial malrotation on knee kinematics after total knee arthroplasty (TKA). A symmetric fixed-bearing posterior-stabilized prosthesis was implanted in the validated knee model with different rotational alignments of the tibial component (neutral, 3° external rotation, 5° external rotation, 3° internal rotation, and 5° internal rotation). Computational kinematic simulations were used to evaluate the postoperative kinematics of the knee joint including anteroposterior translation femoral condyles and axial rotation of tibial component during 0°-135° knee flexion. The results revealed that the neutral position of the tibial component was not the closest kinematics to the intact knee, the model with 5° external rotation of the tibial component showed the closest lateral condyle translation and tibial axial rotation, and moderate external rotation could improve the kinematics after TKA.

19.
Front Bioeng Biotechnol ; 10: 959210, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36032712

RESUMO

Objective: The purpose of this study was to analyze the stability and instrument-related complications associated with fixation of the lumbar spine using the Short-Rod (SR) technique. Methods: Using finite element analysis, this study assessed the stability of a bilateral lumbar fixation system when inserting the pedicle screws at angles of 10°, 15°, and 20° to the endplate in the sagittal plane. Using the most stable construct with a screw angle, the model was then assessed with different rod lengths of 25, 30, 35, and 45 mm. The optimal screw inclination angle and rod length were incorporated into the SR model and compared against traditional parallel screw insertion (pedicle screws in parallel to the endplate, PPS) in terms of the stability and risk of instrument-related complications. The following parameters were evaluated using the validated L4-L5 lumbar finite element model: axial stiffness, range of motion (ROM), stress on the endplate and facet joint, von-Mises stress on the contact surface between the screw and rod (CSSR), and screw displacement. Results: The results showed that the SR model with a 15° screw inclination angle and 35 mm rod length was superior in terms of construct stability and risk of complications. Compared to the PPS model, the SR model had lower stiffness, lower ROM, less screw displacement, and lower stress on the facet cartilage, the CSSR, and screws. However, the SR model also suffered more stress on the endplate in flexion and lateral bending. Conclusion: The SR technique with a 15° screw inclination and 35 mm rod length offers good lumbar stability with a low risk of instrument-related complications.

20.
Front Surg ; 9: 936720, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35846950

RESUMO

Objective: The purpose of this study is to assess the association between the presence and severity of flatfoot and symptoms of knee OA. Methods: 95 participants with knee OA were recruited from a patient cohort at a regional hospital. Symptoms of knee OA, including knee degeneration, femorotibial alignment, pain, stiffness and dysfunction were assessed using the Kellgren-Lawrence (K-L) grading system, femoral-tibial angle (FTA), and Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC). Participants were divided into groups with flatfoot (mild, moderate and severe) and without flatfoot based on the Clarke's angle. Linear regression and ordinal logistic regression were used for statistical analysis, as appropriate. Results: Having flatfoot was associated with a significantly increased risk of having a higher K-L grade (OR: 20.03; 95% CI, 5.88, 68.27; p < 0.001), smaller FTA (Beta: -2.96; 95% CI, -4.41, -1.50; p < 0.001), higher pain score (Beta: 0.47; 95% CI, 0.24, 0.69; p < 0.001) and greater loss of function (Beta: 0.25; 95% CI, 0.02, 0.48; p = 0.03). Severe grades of flat feet were associated with a higher K-L grade (OR: 0.19; 95% CI, 0.08, 0.44; p < 0.001), smaller FTA (Beta: 1.51; 95% CI, 0.66, 2.35; p = 0.001), higher pain score (Beta: -0.25; 95% CI, -0.39, -0.11; p = 0.001), greater stiffness (Beta: -0.24; 95% CI, -0.38, -0.09; p = 0.002) and greater loss of function (Beta: -0.27; 95% CI, -0.41, -0.14; p < 0.001). Conclusion: The results indicated that the severity of flattening is significantly associated with symptoms of knee OA. For the conservative management of knee OA, both flatfoot and its severity should be carefully considered.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA