Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Am J Cardiol ; 207: 380-389, 2023 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-37778227

RESUMO

Few studies have compared the clinical outcomes between valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) with new-generation valves and re-operative surgical aortic valve replacement (Redo-SAVR). We compared the clinical outcomes of patients who underwent ViV-TAVR with those of patients who underwent Redo-SAVR at Cedars-Sinai Medical Center between 2015 and 2021. New-generation valves were used for ViV-TAVR. A propensity score-matched (PSM) analysis was performed to adjust for differences in baseline characteristics. The primary end point was all-cause mortality at 30 days and 2 years. In-hospital procedural and clinical outcomes were also compared between the groups. A total of 256 patients (140 who underwent ViV-TAVR and 116 who underwent Redo-SAVR) were eligible for PSM. In the unmatched cohort, patients in the ViV-TAVR group were older and had more co-morbidities than those in the Redo-SAVR group. After PSM, there were no significant differences in all-cause death between the ViV-TAVR and Redo-SAVR groups at 30 days (3.9% vs 2.6%, p = 0.65) or 2 years (6.5% vs 7.8%, p = 0.75). The incidences of stroke and heart failure rehospitalization were similar at 30 days and 2 years. The cumulative complication rates during hospitalization were significantly lower in the ViV-TAVR group than in the Redo-SAVR group (11.7% vs 28.6% p = 0.015). The long-term outcomes of ViV-TAVR using new-generation valves were similar to those of Redo-SAVR, although ViV-TAVR was associated with lower rates of in-hospital complications.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Falha de Prótese , Reoperação , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Fatores de Risco
2.
Front Cardiovasc Med ; 10: 1167212, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37485260

RESUMO

Objective: Design a predictive risk model for minimizing iliofemoral vascular complications (IVC) in a contemporary era of transfemoral-transcatheter aortic valve replacement (TF-TAVR). Background: IVC remains a common complication of TF-TAVR despite the technological improvement in the new-generation transcatheter systems (NGTS) and enclosed poor outcomes and quality of life. Currently, there is no accepted tool to assess the IVC risk for calcified and tortuous vessels. Methods: We reconstructed CT images of 516 propensity-matched TF-TAVR patients using the NGTS to design a predictive anatomical model for IVC and validated it on a new cohort of 609 patients. Age, sex, peripheral artery disease, valve size, and type were used to balance the matched cohort. Results: IVC occurred in 214 (7.2%) patients. Sheath size (p = 0.02), the sum of angles (SOA) (p < .0001), number of curves (NOC) (p < .0001), minimal lumen diameter (MLD) (p < .001), and sheath-to-femoral artery diameter ratio (SFAR) (p = 0.012) were significant predictors for IVC. An indexed risk score (CSI) consisting of multiplying the SOA and NOC divided by the MLD showed 84.3% sensitivity and 96.8% specificity, when set to >100, in predicting IVC (C-stat 0.936, 95% CI 0.911-0.959, p < 0.001). Adding SFAR > 1.00 in a tree model increased the overall accuracy to 97.7%. In the validation cohort, the model predicted 89.5% of the IVC cases with an overall 89.5% sensitivity, 98.9% specificity, and 94.2% accuracy (C-stat 0.842, 95% CI 0.904-0.980, p < .0001). Conclusion: Our CT-based validated-model is the most accurate and easy-to-use tool assessing IVC risk and should be used for calcified and tortuous vessels in preprocedural planning.

3.
Front Cardiovasc Med ; 9: 1004103, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36211543

RESUMO

Objective: To assess the incidence of new adverse coronary events (NACE) following transcatheter aortic valve replacement (TAVR) and valve-in-valve TAVR (ViV-TAVR). Background: ViV-TAVR is an accepted treatment for degenerative prostheses among patients with high surgical-risk. TAVR studies have suggested an increased risk of coronary artery obstruction and flow stasis causing thrombus formation. Whether contemporary ViV-TAVR is associated with higher rate of coronary events compared to TAVR is unknown. Methods: We used data from 1,224 TAVR patients between 2016 and 2021. We propensity-matched patients following ViV-TAVR and TAVR by significant predictors to overcome confounders in patients' baseline characteristics and procedural factors. Results: The matched population included 129 patients in each group. In line with prior reports, there was a higher in-hospital coronary artery obstruction rate with ViV-TAVR (3.1 vs. 1.6%; p = 0.23). Despite this, 2-year cumulative NACE rates were similar between groups (4.7 vs. 6.2%, respectively, p = 0.79), with no difference between its components: myocardial infarction (MI) (p = 0.210), unplanned coronary catheterization (p = 0.477), or coronary artery bypass grafting (CABG) (p = 0.998). Moreover, hypoattenuated leaflets thickening (HALT) at 30-day CT was observed in nearly a quarter of the patients with no difference between groups (23.9 vs. 23.1%, HR 1.02, 95% CI 0.50-1.28, p = 0.872). The progression rate of the coronary artery calcium score (CACS), assessed in a third of patients, was similar between groups (p log-rank = 0.468, 95% CI 0.12-1.24). Low coronary artery height was an unfavorable predictor for in-hospital coronary obstruction and 2-year NACE rate (HR 1.20 and HR 1.25, p = 0.001 and p < 0.0001, respectively). Conclusion: At 2-year follow-up, ViV-TAVR was not associated with a higher rate of myocardial infarction, unplanned catheterization, coronary artery bypass grafting, or hypoattenuated leaflet thickening.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA