Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 145
Filtrar
1.
bioRxiv ; 2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38712092

RESUMO

Flexible intracortical neural probes have drawn attention for their enhanced longevity in high-resolution neural recordings due to reduced tissue reaction. However, the conventional monolithic fabrication approach has met significant challenges in: (i) scaling the number of recording sites for electrophysiology; (ii) integrating of other physiological sensing and modulation; and (iii) configuring into three-dimensional (3D) shapes for multi-sided electrode arrays. We report an innovative self-assembly technology that allows for implementing flexible origami neural probes as an effective alternative to overcome these challenges. By using magnetic-field-assisted hybrid self-assembly, multiple probes with various modalities can be stacked on top of each other with precise alignment. Using this approach, we demonstrated a multifunctional device with scalable high-density recording sites, dopamine sensors and a temperature sensor integrated on a single flexible probe. Simultaneous large-scale, high-spatial-resolution electrophysiology was demonstrated along with local temperature sensing and dopamine concentration monitoring. A high-density 3D origami probe was assembled by wrapping planar probes around a thin fiber in a diameter of 80∼105 µm using optimal foldable design and capillary force. Directional optogenetic modulation could be achieved with illumination from the neuron-sized micro-LEDs (µLEDs) integrated on the surface of 3D origami probes. We could identify angular heterogeneous single-unit signals and neural connectivity 360° surrounding the probe. The probe longevity was validated by chronic recordings of 64-channel stacked probes in behaving mice for up to 140 days. With the modular, customizable assembly technologies presented, we demonstrated a novel and highly flexible solution to accommodate multifunctional integration, channel scaling, and 3D array configuration.

2.
Nat Commun ; 15(1): 1772, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38413568

RESUMO

Current soft neural probes are still operated by bulky, rigid electronics mounted to a body, which deteriorate the integrity of the device to biological systems and restrict the free behavior of a subject. We report a soft, conformable neural interface system that can monitor the single-unit activities of neurons with long-term stability. The system implements soft neural probes in the brain, and their subsidiary electronics which are directly printed on the cranial surface. The high-resolution printing of liquid metals forms soft neural probes with a cellular-scale diameter and adaptable lengths. Also, the printing of liquid metal-based circuits and interconnections along the curvature of the cranium enables the conformal integration of electronics to the body, and the cranial circuit delivers neural signals to a smartphone wirelessly. In the in-vivo studies using mice, the system demonstrates long-term recording (33 weeks) of neural activities in arbitrary brain regions. In T-maze behavioral tests, the system shows the behavior-induced activation of neurons in multiple brain regions.


Assuntos
Eletrônica , Neurônios , Animais , Camundongos , Neurônios/fisiologia , Encéfalo/fisiologia , Crânio/diagnóstico por imagem , Metais , Impressão Tridimensional
3.
Nat Nanotechnol ; 19(5): 646-651, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38326466

RESUMO

Machines found in nature and human-made machines share common components, such as an engine, and an output element, such as a rotor, linked by a clutch. This clutch, as seen in biological structures such as dynein, myosin or bacterial flagellar motors, allows for temporary disengagement of the moving parts from the running engine. However, such sophistication is still challenging to achieve in artificial nanomachines. Here we present a spherical rotary nanomotor with a reversible clutch system based on precise molecular recognition of built-in DNA strands. The clutch couples and decouples the engine from the machine's rotor in response to encoded inputs such as DNA or RNA. The nanomotor comprises a porous nanocage as a spherical rotor to confine the magnetic engine particle within the nanospace (∼0.004 µm3) of the cage. Thus, the entropically driven irreversible disintegration of the magnetic engine and the spherical rotor during the disengagement process is eliminated, and an exchange of microenvironmental inputs is possible through the nanopores. Our motor is only 200 nm in size and the clutch-mediated force transmission powered by an embedded ferromagnetic nanocrystal is high enough (∼15.5 pN at 50 mT) for the in vitro mechanical activation of Notch and integrin receptors, demonstrating its potential as nano-bio machinery.


Assuntos
DNA , Nanotecnologia , DNA/química , Nanotecnologia/métodos , Nanoporos , Magnetismo
4.
Phys Chem Chem Phys ; 26(10): 8051-8061, 2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38314818

RESUMO

Electron beams are versatile tools for nanoscale fabrication processes, however, the underlying e-beam chemistry remains in its infancy. Through operando transmission electron microscopy investigations, we elucidate a redox-driven cargo release of individual metal atoms triggered by electron beams. The chosen organic delivery molecule, tetraphenylporphyrin (TPP), proves highly versatile, forming complexes with nearly all metals from the periodic table and being easily processed in solution. A comprehensive cinematographic analysis of the dynamics of single metal atoms confirms the nearly instantaneous ejection of complexed metal atoms under an 80 kV electron beam, underscoring the system's broad versatility. Providing mechanistic insights, we employ density functional theory to support the proposed reductive demetallation pathway facilitated by secondary electrons, contributing novel perspectives to electron beam-mediated chemical reaction mechanisms. Lastly, our findings demonstrate that all seven metals investigated form nanoclusters once ejected from TPP, highlighting the method's potential for studying and developing sustainable single-atom and nanocluster catalysts.

5.
Nat Mater ; 23(2): 290-300, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37845321

RESUMO

Measuring cellular and tissue mechanics inside intact living organisms is essential for interrogating the roles of force in physiological and disease processes. Current agents for studying the mechanobiology of intact, living organisms are limited by poor light penetration and material stability. Magnetomotive ultrasound is an emerging modality for real-time in vivo imaging of tissue mechanics. Nonetheless, it has poor sensitivity and spatiotemporal resolution. Here we describe magneto-gas vesicles (MGVs), protein nanostructures based on gas vesicles and magnetic nanoparticles that produce differential ultrasound signals in response to varying mechanical properties of surrounding tissues. These hybrid nanomaterials significantly improve signal strength and detection sensitivity. Furthermore, MGVs enable non-invasive, long-term and quantitative measurements of mechanical properties within three-dimensional tissues and in vivo fibrosis models. Using MGVs as novel contrast agents, we demonstrate their potential for non-invasive imaging of tissue elasticity, offering insights into mechanobiology and its application to disease diagnosis and treatment.


Assuntos
Nanopartículas , Nanoestruturas , Diagnóstico por Imagem/métodos , Proteínas/química , Acústica , Nanopartículas/química
6.
Nano Lett ; 24(1): 270-278, 2024 Jan 10.
Artigo em Inglês | MEDLINE | ID: mdl-38157214

RESUMO

Here, we introduce the magneto-mechanical-genetic (MMG)-driven wireless deep brain stimulation (DBS) using magnetic nanostructures for therapeutic benefits in the mouse model of Parkinson's disease (PD). Electrical DBS of the subthalamic nucleus (STN) is an effective therapy for mitigating Parkinson's motor symptoms. However, its broader application is hampered by the requirement for implanted electrodes and the lack of anatomical and cellular specificity. Using the nanoscale magnetic force actuators (m-Torquer), which deliver torque force under rotating magnetic fields to activate pre-encoded Piezo1 ion channels on target neurons, our system enables wireless and STN-specific DBS without implants, addressing key unmet challenges in the DBS field. In both late- and early-stage PD mice, MMG-DBS significantly improved locomotor activity and motor balance by 2-fold compared to untreated PD mice. Moreover, MMG-DBS enabled sustained therapeutic effects. This approach provides a non-invasive and implant-free DBS with cellular targeting capability for the effective treatment of Parkinsonian symptoms.


Assuntos
Estimulação Encefálica Profunda , Doença de Parkinson , Transtornos Parkinsonianos , Núcleo Subtalâmico , Camundongos , Animais , Doença de Parkinson/genética , Doença de Parkinson/terapia , Transtornos Parkinsonianos/terapia , Núcleo Subtalâmico/fisiologia , Neurônios/fisiologia , Canais Iônicos
7.
Adv Sci (Weinh) ; 10(27): e2301930, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37485618

RESUMO

Detecting early cancer through liquid biopsy is challenging due to the lack of specific biomarkers for early lesions and potentially low levels of these markers. The current study systematically develops an extracellular-vesicle (EV)-based test for early detection, specifically focusing on high-grade serous ovarian carcinoma (HGSOC). The marker selection is based on emerging insights into HGSOC pathogenesis, notably that it arises from precursor lesions within the fallopian tube. This work thus establishes murine fallopian tube (mFT) cells with oncogenic mutations and performs proteomic analyses on mFT-derived EVs. The identified markers are then evaluated with an orthotopic HGSOC animal model. In serially-drawn blood of tumor-bearing mice, mFT-EV markers increase with tumor initiation, supporting their potential use in early cancer detection. A pilot clinical study (n = 51) further narrows EV markers to five candidates, EpCAM, CD24, VCAN, HE4, and TNC. The combined expression of these markers distinguishes HGSOC from non-cancer with 89% sensitivity and 93% specificity. The same markers are also effective in classifying three groups (non-cancer, early-stage HGSOC, and late-stage HGSOC). The developed approach, for the first time inaugurated in fallopian tube-derived EVs, could be a minimally invasive tool to monitor women at high risk of ovarian cancer for timely intervention.


Assuntos
Vesículas Extracelulares , Neoplasias Ovarianas , Humanos , Feminino , Camundongos , Animais , Proteômica , Neoplasias Ovarianas/diagnóstico , Neoplasias Ovarianas/genética , Biomarcadores/metabolismo , Tubas Uterinas/metabolismo , Tubas Uterinas/patologia , Vesículas Extracelulares/metabolismo
8.
ACS Appl Mater Interfaces ; 15(24): 28954-28963, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37283562

RESUMO

For electrocardiogram (ECG) detection, the position of conventional patch-type electrodes based on solid-state metals are difficult to manipulate after attachment and also can lead to poor interface with stretchable, rough skin surfaces. Herein, we present a liquid form of ECG electrodes that can be magnetically reconfigured on human skin by providing its conformal interfacing. These electrodes consist of biocompatible liquid-metal droplets where magnetic particles are homogeneously dispersed, and their conformal contact with skin can yield significantly low impedance as well as high signal-to-noise ratio of ECG peaks. These electrodes are also capable of complex motions such as linear movements, splitting, and merging under external magnetic fields. Furthermore, magnetic manipulation of each electrode position on human skin enables precise monitoring of ECG signals with the change in ECG vectors. The integration of liquid-state electrodes with electronic circuitry demonstrates wireless and continuous ECG monitoring while magnetically moving this entire system on human skin.


Assuntos
Eletrocardiografia , Coração , Humanos , Eletrodos , Monitorização Fisiológica , Metais , Impedância Elétrica
9.
Nano Lett ; 23(11): 5227-5235, 2023 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-37192537

RESUMO

As a new enabling nanotechnology tool for wireless, target-specific, and long-distance stimulation of mechanoreceptors in vivo, here we present a hydrogel magnetomechanical actuator (h-MMA) nanoparticle. To allow both deep-tissue penetration of input signals and efficient force generation, h-MMA integrates a two-step transduction mechanism that converts magnetic anisotropic energy to thermal energy within its magnetic core (i.e., Zn0.4Fe2.6O4 nanoparticle cluster) and then to mechanical energy to induce the surrounding polymer (i.e., pNiPMAm) shell contraction, finally delivering forces to activate targeted mechanoreceptors. We show that h-MMAs enable on-demand modulation of Notch signaling in both fluorescence reporter cell lines and a xenograft mouse model, demonstrating its utility as a powerful in vivo perturbation approach for mechanobiology interrogation in a minimally invasive and untethered manner.


Assuntos
Hidrogéis , Nanopartículas , Humanos , Animais , Camundongos , Fenômenos Mecânicos
10.
Adv Sci (Weinh) ; 10(10): e2206872, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36725305

RESUMO

CRISPR/Cas systems offer a powerful sensing mechanism to transduce sequence-specific information into amplified analytical signals. However, performing multiplexed CRISPR/Cas assays remains challenging and often requires complex approaches for multiplexed assays. Here, a hydrogel-based CRISPR/Cas12 system termed CLAMP (Cas-Loaded Annotated Micro-Particles) is described. The approach compartmentalizes the CRISPR/Cas reaction in spatially-encoded hydrogel microparticles (HMPs). Each HMP is identifiable by its face code and becomes fluorescent when target DNA is present. The assay is further streamlined by capturing HMPs inside a microfluidic device; the captured particles are then automatically recognized by a machine-learning algorithm. The CLAMP assay is fast, highly sensitive (attomolar detection limits with preamplification), and capable of multiplexing in a single-pot assay. As a proof-of-concept clinical application, CLAMP is applied to detect nucleic acid targets of human papillomavirus in cervical brushing samples.


Assuntos
Ácidos Nucleicos , Humanos , Hidrogéis , DNA , Sistemas CRISPR-Cas/genética
11.
Nat Biomed Eng ; 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36543872
12.
Nat Cell Biol ; 24(12): 1739-1753, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36456828

RESUMO

Adherens junctions (AJs) create spatially, chemically and mechanically discrete microdomains at cellular interfaces. Here, using a mechanogenetic platform that generates artificial AJs with controlled protein localization, clustering and mechanical loading, we find that AJs also organize proteolytic hotspots for γ-secretase with a spatially regulated substrate selectivity that is critical in the processing of Notch and other transmembrane proteins. Membrane microdomains outside of AJs exclusively organize Notch ligand-receptor engagement (LRE microdomains) to initiate receptor activation. Conversely, membrane microdomains within AJs exclusively serve to coordinate regulated intramembrane proteolysis (RIP microdomains). They do so by concentrating γ-secretase and primed receptors while excluding full-length Notch. AJs induce these functionally distinct microdomains by means of lipid-dependent γ-secretase recruitment and size-dependent protein segregation. By excluding full-length Notch from RIP microdomains, AJs prevent inappropriate enzyme-substrate interactions and suppress spurious Notch activation. Ligand-induced ectodomain shedding eliminates size-dependent segregation, releasing Notch to translocate into AJs for processing by γ-secretase. This mechanism directs radial differentiation of ventricular zone-neural progenitor cells in vivo and more broadly regulates the proteolysis of other large cell-surface receptors such as amyloid precursor protein. These findings suggest an unprecedented role of AJs in creating size-selective spatial switches that choreograph γ-secretase processing of multiple transmembrane proteins regulating development, homeostasis and disease.


Assuntos
Secretases da Proteína Precursora do Amiloide , Secretases da Proteína Precursora do Amiloide/genética , Ligantes
13.
Nano Lett ; 22(18): 7415-7422, 2022 09 28.
Artigo em Inglês | MEDLINE | ID: mdl-36069378

RESUMO

Regulation of genetic activity in single cells and tissues is pivotal to determine key cellular functions in current biomedicine, yet the conventional biochemical activators lack spatiotemporal precision due to the diffusion-mediated slow kinetics and nonselectivity. Here, we describe a magnetogenetic method for target-specific activation of a clustered regularly interspaced short palindromic repeats (CRISPR) system for the regulation of intracellular proteins. We used magnetomechanical force generated by the magnetic nanostructure to activate pre-encoded Piezo1, the mechanosensitive ion channel, on the target cell. The activated Piezo1 further triggers the intracellular Ca2+ signaling pathway, inducing the pre-encoded genes to express genes of interest (GOIs), which is Cas9 protein for the CRISPR regulation of the target proteins. We demonstrated that this magnetogenetic CRISPR system successfully edits the target genome for both in vitro and pseudo-in vivo environments, providing a versatile magnetic platform for remote gene editing of animals with various size scales.


Assuntos
Proteína 9 Associada à CRISPR , Edição de Genes , Animais , Proteína 9 Associada à CRISPR/genética , Sistemas CRISPR-Cas/genética , Edição de Genes/métodos , Canais Iônicos/genética
15.
Nat Commun ; 13(1): 1438, 2022 03 17.
Artigo em Inglês | MEDLINE | ID: mdl-35301324

RESUMO

Scanning probe microscopy techniques, such as atomic force microscopy and scanning tunnelling microscopy, are harnessed to image nanoscale structures with an exquisite resolution, which has been of significant value in a variety of areas of nanotechnology. These scanning probe techniques, however, are not generally suitable for high-throughput imaging, which has, from the outset, been a primary challenge. Traditional approaches to increasing the scalability have involved developing multiple probes for imaging, but complex probe design and electronics are required to carry out the detection method. Here, we report a probe-based imaging method that utilizes scalable cantilever-free elastomeric probe design and hierarchical measurement architecture, which readily reconstructs high-resolution and high-throughput topography images. In a single scan, we demonstrate imaging with a 100-tip array to obtain 100 images over a 1-mm2 area with 106 pixels in less than 10 min. The potential for large-scale tip integration and the advantage of a simple probe array suggest substantial promise for our approach to high-throughput imaging far beyond what is currently possible.


Assuntos
Microscopia de Varredura por Sonda , Nanotecnologia , Microscopia de Força Atômica/métodos , Microscopia de Varredura por Sonda/métodos , Microscopia de Tunelamento , Nanotecnologia/métodos , Proteínas
17.
Nano Lett ; 21(22): 9543-9550, 2021 11 24.
Artigo em Inglês | MEDLINE | ID: mdl-34762431

RESUMO

We investigated the magnetic effect of Mn2+ ions on an exciton of Mn-doped CsPbI3 quantum dots (QDs), where we looked for the signatures of an exciton magnetic polaron known to produce a large effective magnetic field in Mn-doped CdSe QDs. In contrast to Mn-doped CdSe QDs that can produce ∼100 T of magnetic field upon photoexcitation, manifested as a large change in the energy and relaxation dynamics of a bright exciton, Mn-doped CsPbI3 QDs exhibited little influence of a magnetic dopant on the behavior of a bright exciton. However, a µs-lived dark exciton in CsPbI3 QDs showed 40% faster decay in the presence of Mn2+, equivalent to the effect of ∼3 T of an external magnetic field. While further study is necessary to fully understand the origin of the large difference in the magneto-optic property of an exciton in two systems, we consider that the difference in antiferromagnetic coupling of the dopants is an important contributing factor.


Assuntos
Pontos Quânticos , Fenômenos Magnéticos , Magnetismo , Fenômenos Físicos , Compostos de Zinco
18.
Sci Transl Med ; 13(616): eabe2352, 2021 Oct 20.
Artigo em Inglês | MEDLINE | ID: mdl-34669441

RESUMO

Tetrahydrocannabinol (THC), the primary psychoactive ingredient of cannabis, impairs cognitive and motor function in a concentration-dependent fashion. Drug testing is commonly performed for employment and law enforcement purposes; however, available tests produce low-sensitive binary results (lateral flow assays) or have long turnaround (gas chromatography­mass spectrometry). To enable on-site THC quantification in minutes, we developed a rapid assay for oral THC analysis called EPOCH (express probe for on-site cannabis inhalation). EPOCH features distinctive sensor design such as a radial membrane and transmission optics, all contained in a compact cartridge. This integrated approach permitted assay completion within 5 min with a detection limit of 0.17 ng/ml THC, which is below the regulatory guideline (1 ng/ml). As a proof of concept for field testing, we applied EPOCH to assess oral fluid samples from cannabis users (n = 43) and controls (n = 43). EPOCH detected oral THC in all specimens from cannabis smokers (median concentration, 478 ng/ml) and THC-infused food consumers. Longitudinal monitoring showed a fast drop in THC concentrations within the first 6 hours of cannabis smoking (half-life, 1.4 hours).


Assuntos
Dronabinol , Detecção do Abuso de Substâncias , Bioensaio , Saliva , Espectrometria de Massas em Tandem
19.
Acc Chem Res ; 54(21): 3991-4000, 2021 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-34677927

RESUMO

The modern healthcare system faces an unrelenting threat from microorganisms, as evidenced by global outbreaks of new viral diseases, emerging antimicrobial resistance, and the rising incidence of healthcare-associated infections (HAIs). An effective response to these threats requires rapid and accurate diagnostic tests that can identify causative pathogens at the point of care (POC). Such tests could eliminate diagnostic uncertainties, facilitating patient triaging, minimizing the empiric use of antimicrobial drugs, and enabling targeted treatments. Current standard methods, however, often fail to meet the needs of rapid diagnosis in POC settings. Culture-based assays entail long processing times and require specialized laboratory infrastructure; nucleic acid (NA) tests are often limited to centralized hospitals due to assay complexity and high costs. Here we discuss two new POC tests developed in our groups to enable the rapid diagnosis of infection. The first is nanoPCR that takes advantages of core-shell magnetoplasmonic nanoparticles (MPNs): (i) Au shell significantly accelerates thermocycling via volumetric, plasmonic light-to-heat conversion and (ii) a magnetic core enables sensitive in situ fluorescent detection via magnetic clearing. By adopting a Ferris wheel module, the system expedites multisamples in parallel with a minimal setup. When applied to COVID-19 diagnosis, nanoPCR detected SARS-CoV-2 RNA down to 3.2 copy/µL within 17 min. In particular, nanoPCR diagnostics accurately identified COVID-19 cases in clinical samples (n = 150), validating its clinical applicability. The second is a polarization anisotropy diagnostic (PAD) system that exploits the principle of fluorescence polarization (FP) as a detection modality. Fluorescent probes were designed to alter their molecular weight upon recognizing target NAs. This event modulates the probes' tumbling rate (Brownian motion), which leads to changes in FP. The approach is robust against environmental noise and benefits from the ratiometric nature of the signal readout. We applied PAD to detect clinically relevant HAI bacteria (Escherichia coli, Klebsiella pneumoniae, Acinetobacter baumannii, Pseudomonas aeruginosa, and Staphylococcus aureus). The PAD assay demonstrated detection sensitivity down to the single bacterium level and determined both drug resistance and virulence status. In summary, these new tests have the potential to become powerful tools for rapid diagnosis in the infectious disease space. They do not require highly skilled personnel or labor-intensive analyses, and the assays are quick and cost-effective. These attributes will make nanoPCR and PAD well-aligned with a POC workflow to aid physicians to initiate prompt and informed patient treatment.


Assuntos
Infecções Bacterianas/diagnóstico , Teste para COVID-19 , COVID-19/diagnóstico , Polarização de Fluorescência , Nanotecnologia , Reação em Cadeia da Polimerase , Corantes Fluorescentes/química , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , RNA Viral/genética , SARS-CoV-2/genética
20.
Nano Lett ; 21(8): 3649-3656, 2021 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-33856815

RESUMO

Nanoparticles with multifunctionality and high colloidal stability are essential for biomedical applications. However, their use is often hindered by the formation of thick coating shells and/or nanoparticle agglomeration. Herein, we report a single nanoparticle coating strategy to form 1 nm polymeric shells with a variety of chemical functional groups and surface charges. Under exposure to alternating magnetic field, nanosecond thermal energy pulses trigger a polymerization in the region only a few nanometers from the magnetic nanoparticle (MNP) surface. Modular coatings containing functional groups, according to the respective choice of monomers, are possible. In addition, the surface charge can be tuned from negative through neutral to positive. We adopted a coating method for use in biomedical targeting studies where obtaining compact nanoparticles with the desired surface charge is critical. A single MNP with a zwitterionic charge can provide excellent colloidal stability and cell-specific targeting.


Assuntos
Nanopartículas , Magnetismo , Polimerização , Polímeros
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA