Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Isr Med Assoc J ; 20(5): 269-276, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29761670

RESUMO

BACKGROUND: Limited information exists about detailed clinical characteristics and management of the small subset of Brugada syndrome (BrS) patients who had an arrhythmic event (AE). OBJECTIVES: To conduct the first nationwide survey focused on BrS patients with documented AE. METHODS: Israeli electrophysiology units participated if they had treated BrS patients who had cardiac arrest (CA) (lethal/aborted; group 1) or experienced appropriate therapy for tachyarrhythmias after prophylactic implantable cardioverter defibrillator (ICD) implantation (group 2). RESULTS: The cohort comprised 31 patients: 25 in group 1, 6 in group 2. Group 1: 96% male, mean CA age 38 years (range 13-84). Nine patients (36%) presented with arrhythmic storm and three had a lethal outcome; 17 (68%) had spontaneous type 1 Brugada electrocardiography (ECG). An electrophysiology study (EPS) was performed on 11 patients with inducible ventricular fibrillation (VF) in 10, which was prevented by quinidine in 9/10 patients. During follow-up (143 ± 119 months) eight patients experienced appropriate shocks, none while on quinidine. Group 2: all male, age 30-53 years; 4/6 patients had familial history of sudden death age < 50 years. Five patients had spontaneous type 1 Brugada ECG and four were asymptomatic at ICD implantation. EPS was performed in four patients with inducible VF in three. During long-term follow-up, five patients received ≥ 1 appropriate shocks, one had ATP for sustained VT (none taking quinidine). No AE recurred in patients subsequently treated with quinidine. CONCLUSIONS: CA from BrS is apparently a rare occurrence on a national scale and no AE occurred in any patient treated with quinidine.


Assuntos
Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Síndrome de Brugada/epidemiologia , Síndrome de Brugada/fisiopatologia , Desfibriladores Implantáveis , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/terapia , Síndrome de Brugada/terapia , Estudos de Coortes , Comorbidade , Eletrocardiografia/métodos , Feminino , Seguimentos , Humanos , Israel/epidemiologia , Masculino , Pessoa de Meia-Idade , Quinidina/uso terapêutico , Adulto Jovem
2.
Europace ; 16(8): 1175-80, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24554524

RESUMO

AIMS: Implantable cardioverter-defibrillators (ICDs) improve survival in certain high arrhythmic risk populations. However, there are sex differences regarding both the utilization and the benefit of these devices. Using a prospective national ICD registry, we aim to compare the indications for ICD implantation as well as outcomes in implanted women vs. men. METHODS AND RESULTS: All subjects implanted with an ICD or cardiac resynchronization therapy with a defibrillator (CRTD) in Israel between July 2010 and February 2013 were included. A total of 3544 subjects constructed the baseline cohort, of whom 615 (17%) were women. Women had the same age (64 years) and rate of secondary prevention indication (26%) as men. However, women were more likely than men to have significant heart failure symptoms (52 vs. 45%), QRS > 120 ms (41 vs. 36%), and a higher rate of non-ischaemic cardiomyopathy (54 vs. 21%, all P values <0.05). Using multivariate analysis, women were more likely to undergo CRTD implantation (odds ratio = 1.8, P < 0.01). Follow-up data were available for 1518 subjects with a mean follow-up of 12 months. During follow-up, there were no significant differences among genders in the rate of any single or the combined outcomes of appropriate device therapies, heart failure admissions, or death. First-year re-intervention rate was double among women (5.6 vs. 3.0%, P < 0.01). CONCLUSION: In real-world setting, women implanted with an ICD differ significantly from men in their baseline characteristics and in the use of CRTD devices. These, however, did not translate into outcome differences.


Assuntos
Arritmias Cardíacas/terapia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia de Ressincronização Cardíaca , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Disparidades nos Níveis de Saúde , Disparidades em Assistência à Saúde , Prevenção Primária/instrumentação , Prevenção Secundária/instrumentação , Idoso , Arritmias Cardíacas/complicações , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Feminino , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Hospitalização , Humanos , Israel , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Modelos de Riscos Proporcionais , Estudos Prospectivos , Sistema de Registros , Retratamento , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA