Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
JACC Cardiovasc Interv ; 17(14): 1667-1675, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-39048253

RESUMO

BACKGROUND: Outcomes from transcatheter aortic valve replacement (TAVR) in low-surgical risk patients with bicuspid aortic stenosis beyond 2 years are limited. OBJECTIVES: This study aimed to evaluate 3-year clinical and echocardiographic outcomes from the Evolut Low Risk Bicuspid Study. METHODS: The Evolut Low Risk Bicuspid Study is a prospective, multicenter, single-arm study conducted in 25 U.S. CENTERS: Patients with severe aortic stenosis at low surgical risk with bicuspid aortic valve anatomy (all subtypes) underwent TAVR with a self-expanding, supra-annular Evolut R or PRO (Medtronic) bioprosthesis. An independent clinical events committee adjudicated all deaths and endpoint-related adverse events, and a central echocardiographic core laboratory assessed hemodynamic endpoints. RESULTS: An attempted implant was performed in 150 patients from December 2018 to October 2019. The mean age was 70.3 ± 5.5 years, 48% (72/150) of the patients were women, and the mean Society of Thoracic Surgeons Predicted Risk of Mortality score was 1.3% (Q1-Q3: 0.9%-1.7%). Sievers type 1 was the dominant bicuspid morphology (90.7%, 136/150). The Kaplan-Meier rates of all-cause mortality or disabling stroke were 1.3% (95% CI: 0.3%-5.3%) at 1 year, 3.4% (95% CI: 1.4%-8.1%) at 2 years, and 4.1% (95% CI: 1.6%-10.7%) at 3 years. The incidence of new permanent pacemaker implantation was 19.4% (95% CI: 12.4%-29.6%) at 3 years. There were no instances of moderate or severe paravalvular aortic regurgitation at 2 and 3 years after TAVR. CONCLUSIONS: The 3-year results from the Evolut Low Risk Bicuspid Study demonstrate low rates of all-cause mortality or disabling stroke and favorable hemodynamic performance.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Bioprótese , Próteses Valvulares Cardíacas , Hemodinâmica , Desenho de Prótese , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Fatores de Risco , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/anormalidades , Medição de Risco , Doença da Válvula Aórtica Bicúspide/cirurgia , Doença da Válvula Aórtica Bicúspide/fisiopatologia , Estados Unidos/epidemiologia , Índice de Gravidade de Doença , Complicações Pós-Operatórias/mortalidade , Recuperação de Função Fisiológica , Idoso de 80 Anos ou mais , Pessoa de Meia-Idade , Doenças das Valvas Cardíacas/fisiopatologia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Doenças das Valvas Cardíacas/mortalidade
2.
Artigo em Inglês | MEDLINE | ID: mdl-38871537

RESUMO

BACKGROUND: Permanent pacemaker implantation (PPI) rates following transcatheter aortic valve replacement (TAVR) remain a concern. We assessed the PPI rates over time in patients implanted with an Evolut supra-annular, self-expanding transcatheter valve from the US STS/ACC TVT Registry. METHODS: Patients who underwent TAVR with an Evolut R, Evolut PRO or Evolut PRO+ valve between July 2018 (Q3) and June 2021 (Q2) were included. PPI rates were reported by calendar quarter. In-hospital PPI rates were reported as proportions and 30-day rates as Kaplan-Meier estimates. A Cox regression model was used to determine potential predictors of a new PPI within 30 days of the TAVR procedure. RESULTS: From July 2018 to June 2021, 54,014 TAVR procedures were performed using Evolut valves. Mean age was 79.3 ± 8.8 years and 49.2 % were male. The 30-day PPI rate was 16.6 % in 2018 (Q3) and 10.8 % in 2021 (Q2, 34.9 % decrease, p < 0.001 for trend across all quarters). The in-hospital PPI rate decreased by 40.1 %; from 14.7 % in 2018 (Q3) to 8.8 % in 2021 (Q2) (p < 0.001 for trend across all quarters). Significant predictors of a new PPI within 30 days included a baseline conduction defect, history of atrial fibrillation, home oxygen, and diabetes mellitus. CONCLUSION: From 2018 to 2021, TAVR with an Evolut transcatheter heart valve in over 50,000 patients showed a significant decreasing trend in the rates of in-hospital and 30-day PPI, representing the lowest rate of PPI in any large real-world registry of Evolut. During the same evaluated period, high device success and shorter length of stay was also observed.

3.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747561

RESUMO

BACKGROUND AND AIMS: This trial sought to assess the safety and efficacy of ShortCut, the first dedicated leaflet modification device, prior to transcatheter aortic valve implantation (TAVI) in patients at risk for coronary artery obstruction. METHODS: This pivotal prospective study enrolled patients with failed bioprosthetic aortic valves scheduled to undergo TAVI and were at risk for coronary artery obstruction. The primary safety endpoint was procedure-related mortality or stroke at discharge or 7 days, and the primary efficacy endpoint was per-patient leaflet splitting success. Independent angiographic, echocardiographic, and computed tomography core laboratories assessed all images. Safety events were adjudicated by a clinical events committee and data safety monitoring board. RESULTS: Sixty eligible patients were treated (77.0 ± 9.6 years, 70% female, 96.7% failed surgical bioprosthetic valves, 63.3% single splitting and 36.7% dual splitting) at 22 clinical sites. Successful leaflet splitting was achieved in all (100%; 95% confidence interval [CI] 94-100.0%, p<0.001) patients. Procedure time, including imaging confirmation of leaflet splitting, was 30.6 ± 17.9 min. Freedom from the primary safety endpoint was achieved in 59 (98.3%; 95% CI [91.1-100%]) patients, with no mortality and one (1.7%) disabling stroke. At 30 days, freedom from coronary obstruction was 95% (95% CI 86.1-99.0%). Within 90 days, freedom from mortality was 95% (95% CI 86.1-99.0%]), without any cardiovascular deaths. CONCLUSIONS: Modification of failed bioprosthetic aortic valve leaflets using ShortCut was safe, achieved successful leaflet splitting in all patients, and was associated with favorable clinical outcomes in patients at risk for coronary obstruction undergoing TAVI.

4.
Artigo em Inglês | MEDLINE | ID: mdl-38599918

RESUMO

BACKGROUND: The next generation supra-annular, self-expanding Evolut FX transcatheter aortic valve (TAV) system was designed to improve catheter deliverability, provide stable and symmetric valve deployment, and assess commissural alignment during the procedure. The impact of these modifications has not been clinically evaluated. METHODS: Procedural information was collected by survey in 2 Stages: Stage I comprised 23 centers with extensive experience with Evolut TAV systems, and Stage II comprised an additional 46 centers with a broad range of balloon- and self-expanding system experience. Operators were to compare the experience with the Evolut FX to the predicate Evolut PRO+ system. RESULTS: There were 285 cases during Stage I from June 24 to August 12, 2022, and 254 cases during Stage II from August 15 to September 11, 2022. Overall, the cusp overlap technique was used in 88.6 %, and commissural alignment was achieved in 96.1 % of these cases. Compared to implanter's previous experience with the Evolut PRO+ system, less resistance was noted with the Evolut FX system: in 83.0 % of cases during vascular insertion, in 84.7 % of cases while tracking through the vasculature, in 84.4 % of cases while traversing over the arch, and 76.1 % of cases in advancing across the valve. Better symmetry of valve depth was observed in 423 of 525 cases (80.6 %). CONCLUSION: Evolut FX system design modifications translated into improvements in catheter deliverability, deployment symmetry and stability, and commissural alignment as assessed by experienced self-expanding and balloon expandable operators.

5.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38658126

RESUMO

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Artéria Femoral , Nível de Saúde , Próteses Valvulares Cardíacas , Qualidade de Vida , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Masculino , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Idoso , Idoso de 80 Anos ou mais , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Cateterismo Periférico/efeitos adversos , Punções , Desenho de Prótese
6.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38573257

RESUMO

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Complicações Pós-Operatórias , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Complicações Pós-Operatórias/cirurgia , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Resultado do Tratamento , Incidência , Retratamento
7.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Artigo em Inglês | MEDLINE | ID: mdl-38552656

RESUMO

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Am J Cardiol ; 214: 1-7, 2024 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-38110018

RESUMO

Transcatheter aortic valve replacement (TAVR) provides an option for extreme-risk patients who underwent reoperation for a failed surgical aortic bioprosthesis. Long-term data on patients who underwent TAVR within a failed surgical aortic valve (TAV-in-SAV) are limited. The CoreValve Expanded Use Study evaluated patients at extreme surgical risk who underwent TAV-in-SAV. Outcomes at 5 years were analyzed by SAV failure mode (stenosis, regurgitation, or combined). Echocardiographic outcomes are site-reported. TAV-in-SAV was attempted in 226 patients with a mean age of 76.7 ± 10.8 years; 63.3% were male, the Society of Thoracic Surgeons predicted risk of mortality score was 9.0 ± 6.7%, and 87.5% had a New York Heart Association classification III or IV symptoms. Most of the failed surgical bioprostheses were stented (81.9%), with an average implant duration of 10.2 ± 4.3 years. The 5-year all-cause mortality or major stroke rate was 47.2% in all patients; 54.4% in the stenosis, 37.6% in the regurgitation, and 38.0% in the combined groups (p = 0.046). At 5 years, all-cause mortality was higher in patients with versus without 30-day severe prosthesis-patient mismatch (51.7% vs 38.3%, p = 0.026). The overall aortic valve reintervention rate was 5.9%; highest in the regurgitation group (12.6%). The mean aortic valve gradient was 14.1 ± 9.8 mm Hg and effective orifice area was 1.57 ± 0.70 at 5 years. Few patients had >mild paravalvular regurgitation at 5 years (5.5% moderate, 0.0% severe). TAV-in-SAV with supra-annular, self-expanding TAVR continues to represent a safe and lasting intermediate option for extreme-risk patients who have appropriate sizing of the preexisting failed surgical valve. Clinical and hemodynamic outcomes were stable through 5 years.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Feminino , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Seguimentos , Constrição Patológica/etiologia , Constrição Patológica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Instrumentos Cirúrgicos , Desenho de Prótese , Fatores de Risco
9.
Am J Cardiol ; 213: 99-105, 2024 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-38110022

RESUMO

The association, if any, between the effective regurgitant orifice area (EROA) to left ventricular end-diastolic volume (LVEDV) ratio and 1-year mortality is controversial in patients who undergo mitral transcatheter edge-to-edge repair (m-TEER) with the MitraClip system (Abbott Vascular, Santa Clara, CA). This study's objective was to determine the association between EROA/LVEDV and 1-year mortality in patients who undergo m-TEER with MitraClip. In patients with severe secondary (functional) mitral regurgitation (MR), we analyzed registry data from 11 centers using generalized linear models with the generalized estimating equations approach. We studied 525 patients with secondary MR who underwent m-TEER. Most patients were male (63%) and were New York Heart Association class III (61%) or IV (21%). Mitral regurgitation was caused by ischemic cardiomyopathy in 51% of patients. EROA/LVEDV values varied widely, with median = 0.19 mm2/ml, interquartile range [0.12,0.28] mm2/ml, and 187 patients (36%) had values <0.15 mm2/ml. Postprocedural mitral regurgitation severity was substantially alleviated, being 1+ or less in 74%, 2+ in 20%, 3+ in 4%, and 4+ in 2%; 1-year mortality was 22%. After adjustment for confounders, the logarithmic transformation (Ln) of EROA/LVEDV was associated with 1-year mortality (odds ratio 0.600, 95% confidence interval 0.386 to 0.933, p = 0.023). A higher Society of Thoracic Surgeons risk score was also associated with increased mortality. In conclusion, lower values of Ln(EROA/LVEDV) were associated with increased 1-year mortality in this multicenter registry. The slope of the association is steep at low values but gradually flattens as Ln(EROA/LVEDV) increases.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Masculino , Feminino , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Resultado do Tratamento , Sistema de Registros , América do Norte
10.
JACC Adv ; 2(8): 100581, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-38938330

RESUMO

Background: Cardiac rehabilitation (CR) is strongly recommended for a spectrum of cardiovascular conditions and procedures including aortic valve replacement. Objectives: The purpose of this study was to characterize patient and hospital factors associated with CR participation after transcatheter aortic valve replacement (TAVR) and determine which factors explain hospital-level variation in CR participation. Methods: We linked clinical and administrative claims data from patients who underwent TAVR at 24 Michigan hospitals between January 1, 2016 and June 30, 2020 and obtained rates of CR enrollment within 90 days of discharge. Sequential mixed models were fit to evaluate hospital variation in 90-day post-TAVR CR participation. Results: Among 3,372 patients, 30.6% participated in CR within 90-days after discharge. Several patient factors were negatively associated with CR participation after TAVR including older age, Medicaid insurance, atrial fibrillation/flutter, dialysis use, and slower baseline 5-m walk times. There was substantial hospital variation in CR participation after TAVR ranging from 5% to 60% across 24 hospitals. Patient case mix did not explain hospital variation in CR across hospitals with median OR numerically increasing from 2.11 (95% CI: 1.62-2.67) to 2.13 (95% CI: 1.61-2.68) after accounting for patient-level factors. Conclusions: Less than 1 in 3 patients who underwent TAVR in Michigan participated in CR within 90-days of discharge. Although several patient factors are associated with CR participation, hospital-level variation in CR participation after TAVR is not explained by patient case mix. Identifying hospital processes of care that promote CR participation after TAVR will be critical to improving CR participation after TAVR.

11.
JACC Adv ; 2(9): 100641, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38938726

RESUMO

Background: Prior studies of aortic valve replacement (AVR) in patients with normal-flow, low-gradient aortic stenosis (NF-LG AS) have demonstrated conflicting results regarding the survival benefit of AVR. Changes in quality of life (QoL) after transcatheter AVR (TAVR) have not been reported in this population. Objectives: The purpose of this study was to compare changes in QoL after TAVR for patients with NF-LG AS to patients with high-gradient aortic stenosis (HG-AS). Methods: Patients who underwent TAVR for severe aortic stenosis (AS) were divided into 4 hemodynamic profiles of AS, including NF-LG AS. Changes in Kansas City Cardiomyopathy Questionnaire-12 score from baseline to 1 year were compared between AS groups. The primary composite outcome indicating clinical improvement consisted of survival to 1 year and improved Kansas City Cardiomyopathy Questionnaire overall summary score of ≥5 points while adjusting for relevant baseline factors. Results: Out of 860 patients who underwent TAVR, high gradient AS was present in 368 (42.8%) patients and NF-LG AS in 245 (28.5%). HG-AS and NF-LG AS groups had a similar proportion of patients who met the primary unadjusted outcome of clinical improvement (70.4% vs 63.9%, respectively; P = 0.189). One-year Kaplan-Meier mortality estimates were higher for NF-LG AS patients than HG-AS patients (12.9% vs 5.8%, P < 0.001). In the primary adjusted analysis, there was no significant difference in the composite outcome between HG and NF-LG AS groups (adjusted OR: 0.72, 95% CI: 0.47-1.11). Conclusions: Selected patients with NF-LG AS experienced similar improvement in QoL after TAVR compared with HG-AS. Further investigation of patients with NF-LG AS will help to inform optimal selection for treatment with TAVR.

12.
J Soc Cardiovasc Angiogr Interv ; 2(6Part A): 101116, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-39129891

RESUMO

Background: Bifurcation represents a challenging lesion subset for percutaneous coronary intervention. Methods: In this prospective study of the Resolute Onyx zotarolimus-eluting stent (ZES), patients with a single bifurcation target lesion who underwent planned treatment using a provisional stenting technique were enrolled at 25 centers in the United States and Europe. The primary end point was target-vessel failure (TVF) at 1 year, and follow-up was performed through 3 years. Results: A total of 205 patients were enrolled. Mean age was 66.6 ± 10.7 years, 21.5% of patients were female, and diabetes mellitus was present in 30.2%. A provisional approach with a single stent was performed in 96.6% of patients. The rate of TVF at 1 year was 7.4%, fulfilling the prespecified performance criterion (upper 1-sided 95% CI of 11.1%, compared with the performance goal of 24.5%). At 3-year follow-up, the rate of TVF was 12.1%, the rate of clinically driven target-lesion revascularization was 6.0%, and there were no episodes of stent thrombosis related to the target lesion. Event rates were consistent among the cohort of patients with angiographic core laboratory-confirmed bifurcation lesions. Conclusions: In this prospective, multicenter study, bifurcation lesion treatment with Resolute Onyx ZES using a planned provisional stent approach was associated with favorable clinical outcomes through 3 years. These results support the longer-term safety and effectiveness of Resolute Onyx ZES to treat bifurcation lesions that are amenable to a planned provisional stenting technique.

13.
J Soc Cardiovasc Angiogr Interv ; 2(1): 100530, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-39132542

RESUMO

Background: Aortic regurgitation (AR) is common and detrimental in patients with left ventricular assist devices (LVADs). Off-label use of transcatheter aortic valve replacement (TAVR) has emerged as a potential treatment option. Further data are required regarding the feasibility and outcomes of TAVR to treat AR in LVAD recipients. Methods: A retrospective review of all patients with LVADs who underwent TAVR for the treatment of AR at a single center was performed. All echocardiograms were independently reviewed to ensure accuracy. Results: Eleven patients with continuous-flow LVADs underwent TAVR for AR. All patients had moderate or severe AR with New York Heart Association (NYHA) class III and IV symptoms. Implantation of more than 1 valve was required in 4 (36.3%) patients; 1 patient died during the procedure because of valve migration into the left ventricle and 1 patient died in-hospital after TAVR. Of 9 (81.8%) patients discharged alive, 8 (72.7%) were alive at 12 months and all survivors had improvement in AR severity, natriuretic peptide levels, left ventricle end-diastolic diameter, and NYHA class. Five (62.5%) survivors had a large improvement (>20 points) in the Kansas City Cardiomyopathy Questionnaire score at 1 year. One survivor experienced heart failure, requiring hospitalization, within 1 year. Conclusions: In this single-center series, TAVR for the treatment of AR in patients with LVADs is technically challenging but feasible in select patients and may produce durable improvements in AR severity, functional status, and quality of life.

14.
J Soc Cardiovasc Angiogr Interv ; 1(3): 100038, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-39131953

RESUMO

Background: Acute kidney injury (AKI) after contrast-guided interventions is associated with adverse outcomes, but the role of contrast in the context of renal function is less well described for patients undergoing transcatheter aortic valve replacement (TAVR). Methods: Patients from the Michigan TAVR registry between January 2016 and December 2019 were included. AKI was defined using Valve Academic Research Consortium 2 definitions. An integer cut point for the ratio of contrast volume (CV) to renal function (estimated glomerular filtration rate [eGFR]) as a predictor of AKI was calculated. Results: Of 7112 cases, AKI occurred in 629 (8.8%) patients. Unadjusted mortality was higher among patients with AKI (32.5% vs 9.0%, P â€‹< â€‹.0001). AKI remained significantly associated with the risk of mortality after multivariable adjustment (hazard ratio = 4.50, P â€‹< â€‹.001). Procedural characteristics associated with AKI included CV/eGFR >2 (adjusted odds ratio [aOR] = 1.36, P = .003, 95% CI = 1.10-1.67), CV/eGFR >3 (aOR = 1.38, P â€‹= â€‹.009, 95% CI = 1.09-1.77), and use of general anesthesia (aOR = 1.67, P â€‹< â€‹.0001, 95% CI = 1.38-2.03). Conclusions: CV in the context of renal function administrated during TAVR is a robust tool to predict AKI. AKI after TAVR is associated with an increased risk of mortality. Incorporation of thresholds of >2× and > 3× eGFR into procedural planning should be considered as a quality initiative.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA