Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Med Phys ; 51(7): 4721-4735, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38386904

RESUMO

BACKGROUND: Time-resolved magnetic resonance fingerprinting (MRF), or 4D-MRF, has been demonstrated its feasibility in motion management in radiotherapy (RT). However, the prohibitive long acquisition time is one of challenges of the clinical implementation of 4D-MRF. The shortening of acquisition time causes data insufficiency in each respiratory phase, leading to poor accuracies and consistencies of the predicted tissues' properties of each phase. PURPOSE: To develop a technique for the reconstruction of multi-phase parametric maps in four-dimensional magnetic resonance fingerprinting (4D-MRF) through the optimization of local T1 and T2 sensitivities. METHODS: The proposed technique employed an iterative optimization to tailor the data arrangement of each phase by manipulation of inter-phase frames, such that the T1 and T2 sensitivities, which were quantified by the modified Minkowski distance, of the truncated signal evolution curve was maximized. The multi-phase signal evolution curves were modified by sliding window reconstruction and inter-phase frame sharing (SWIFS). Motion correction (MC) and dot product matching were sequentially performed on the modified signal evolution and dictionary to reconstruct the multi-parametric maps. The proposed technique was evaluated by numerical simulations using the extended cardiac-torso (XCAT) phantom with regular and irregular breathing patterns, and by in vivo MRF data of three health volunteers and six liver cancer patients acquired at a 3.0 T scanner. RESULTS: In simulation study, the proposed SWIFS approach achieved the overall mean absolute percentage error (MAPE) of 8.62% ± 1.59% and 16.2% ± 3.88% for the eight-phases T1 and T2 maps, respectively, in the sagittal view with irregular breathing patterns. In contrast, the overall MAPE of T1 and T2 maps generated by the conventional approach with multiple MRF repetitions were 22.1% ± 11.0% and 30.8% ± 14.9%, respectively. For in-vivo study, the predicted mean T1 and T2 of liver by the proposed SWIFS approach were 795 ms ± 38.9 ms and 58.3 ms ± 11.7 ms, respectively. CONCLUSIONS: Both simulation and in vivo results showed that the approach empowered by T1 and T2 sensitivities optimization and sliding window under the shortened acquisition of MRF had superior performance in the estimation of multi-phase T1 and T2 maps as compared to the conventional approach with oversampling of MRF data.


Assuntos
Imageamento por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética/métodos , Imageamento Tridimensional/métodos , Respiração , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Movimento
2.
Radiother Oncol ; 189: 109948, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37832790

RESUMO

BACKGROUND AND PURPOSE: Motion estimation from severely downsampled 4D-MRI is essential for real-time imaging and tumor tracking. This simulation study developed a novel deep learning model for simultaneous MR image reconstruction and motion estimation, named the Downsampling-Invariant Deformable Registration (D2R) model. MATERIALS AND METHODS: Forty-three patients undergoing radiotherapy for liver tumors were recruited for model training and internal validation. Five prospective patients from another center were recruited for external validation. Patients received 4D-MRI scans and 3D MRI scans. The 4D-MRI was retrospectively down-sampled to simulate real-time acquisition. Motion estimation was performed using the proposed D2R model. The accuracy and robustness of the proposed D2R model and baseline methods, including Demons, Elastix, the parametric total variation (pTV) algorithm, and VoxelMorph, were compared. High-quality (HQ) 4D-MR images were also constructed using the D2R model for real-time imaging feasibility verification. The image quality and motion accuracy of the constructed HQ 4D-MRI were evaluated. RESULTS: The D2R model showed significantly superior and robust registration performance than all the baseline methods at downsampling factors up to 500. HQ T1-weighted and T2-weighted 4D-MR images were also successfully constructed with significantly improved image quality, sub-voxel level motion error, and real-time efficiency. External validation demonstrated the robustness and generalizability of the technique. CONCLUSION: In this study, we developed a novel D2R model for deformation estimation of downsampled 4D-MR images. HQ 4D-MR images were successfully constructed using the D2R model. This model may expand the clinical implementation of 4D-MRI for real-time motion management during liver cancer treatment.


Assuntos
Processamento de Imagem Assistida por Computador , Neoplasias Hepáticas , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Movimento (Física) , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia
3.
Med Phys ; 49(5): 3159-3170, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35171511

RESUMO

BACKGROUND: Most available four-dimensional (4D)-magnetic resonance imaging (MRI) techniques are limited by insufficient image quality and long acquisition times or require specially designed sequences or hardware that are not available in the clinic. These limitations have greatly hindered the clinical implementation of 4D-MRI. PURPOSE: This study aims to develop a fast ultra-quality (UQ) 4D-MRI reconstruction method using a commercially available 4D-MRI sequence and dual-supervised deformation estimation model (DDEM). METHODS: Thirty-nine patients receiving radiotherapy for liver tumors were included. Each patient was scanned using a time-resolved imaging with interleaved stochastic trajectories (TWIST)-lumetric interpolated breath-hold examination (VIBE) MRI sequence to acquire 4D-magnetic resonance (MR) images. They also received 3D T1-/T2-weighted MRI scans as prior images, and UQ 4D-MRI at any instant was considered a deformation of them. A DDEM was developed to obtain a 4D deformable vector field (DVF) from 4D-MRI data, and the prior images were deformed using this 4D-DVF to generate UQ 4D-MR images. The registration accuracies of the DDEM, VoxelMorph (normalized cross-correlation [NCC] supervised), VoxelMorph (end-to-end point error [EPE] supervised), and the parametric total variation (pTV) algorithm were compared. Tumor motion on UQ 4D-MRI was evaluated quantitatively using region of interest (ROI) tracking errors, while image quality was evaluated using the contrast-to-noise ratio (CNR), lung-liver edge sharpness, and perceptual blur metric (PBM). RESULTS: The registration accuracy of the DDEM was significantly better than those of VoxelMorph (NCC supervised), VoxelMorph (EPE supervised), and the pTV algorithm (all, p < 0.001), with an inference time of 69.3 ± 5.9 ms. UQ 4D-MRI yielded ROI tracking errors of 0.79 ± 0.65, 0.50 ± 0.55, and 0.51 ± 0.58 mm in the superior-inferior, anterior-posterior, and mid-lateral directions, respectively. From the original 4D-MRI to UQ 4D-MRI, the CNR increased from 7.25 ± 4.89 to 18.86 ± 15.81; the lung-liver edge full-width-at-half-maximum decreased from 8.22 ± 3.17 to 3.65 ± 1.66 mm in the in-plane direction and from 8.79 ± 2.78 to 5.04 ± 1.67 mm in the cross-plane direction, and the PBM decreased from 0.68 ± 0.07 to 0.38 ± 0.01. CONCLUSION: This novel DDEM method successfully generated UQ 4D-MR images based on a commercial 4D-MRI sequence. It shows great promise for improving liver tumor motion management during radiation therapy.


Assuntos
Neoplasias Hepáticas , Imageamento por Ressonância Magnética , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Movimento (Física)
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA