Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
JAMA Pediatr ; 175(9): 911-918, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34125148

RESUMO

Importance: Establishing stable breathing is a key event for preterm infants after birth. Delivery of pressure-stable continuous positive airway pressure and avoiding face mask use could be of importance in the delivery room. Objective: To determine whether using a new respiratory support system with low imposed work of breathing and short binasal prongs decreases delivery room intubations or death compared with a standard T-piece system with a face mask. Design, Setting, and Participants: In this unblinded randomized clinical trial, mothers threatening preterm delivery before week 28 of gestation were screened. A total of 365 mothers were enrolled, and 250 infants were randomized before birth and 246 liveborn infants were treated. The trial was conducted in 7 neonatal intensive care units in 5 European countries from March 2016 to May 2020. The follow-up period was 72 hours after intervention. Interventions: Infants were randomized to either the new respiratory support system with short binasal prongs (n = 124 infants) or the standard T-piece system with face mask (n = 122 infants). The intervention was providing continuous positive airway pressure for 10 to 30 minutes and positive pressure ventilation, if needed, with the randomized system. Main Outcomes and Measures: The primary outcome was delivery room intubation or death within 30 minutes of birth. Secondary outcomes included respiratory and safety variables. Results: Of 246 liveborn infants treated, the mean (SD) gestational age was 25.9 (1.3) weeks, and 127 (51.6%) were female. A total of 41 infants (33.1%) receiving the new respiratory support system were intubated or died in the delivery room compared with 55 infants (45.1%) receiving standard care. The adjusted odds ratio was statistically significant after adjusting for stratification variables (adjusted odds ratio, 0.53; 95% CI, 0.30-0.94; P = .03). No significant differences were seen in secondary outcomes or safety variables. Conclusions and Relevance: In this study, using the new respiratory support system reduced delivery room intubation in extremely preterm infants. Stabilizing preterm infants with a system that has low imposed work of breathing and binasal prongs as interface is safe and feasible. Trial Registration: ClinicalTrials.gov Identifier: NCT02563717.


Assuntos
Idade Gestacional , Avaliação de Resultados em Cuidados de Saúde/estatística & dados numéricos , Terapia Respiratória/normas , Parto Obstétrico/efeitos adversos , Parto Obstétrico/instrumentação , Parto Obstétrico/métodos , Feminino , Humanos , Recém-Nascido , Unidades de Terapia Intensiva Neonatal/organização & administração , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Masculino , Razão de Chances , Avaliação de Resultados em Cuidados de Saúde/métodos , Terapia Respiratória/métodos , Terapia Respiratória/estatística & dados numéricos , Suécia
2.
Pediatr Pulmonol ; 53(9): 1245-1251, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29999596

RESUMO

OBJECTIVE: To compare short-term application of nasal high-frequency oscillatory ventilation (nHFOV) with nasal continuous positive airway pressure (nCPAP). WORKING HYPOTHESIS: nHFOV improves CO2 removal with respect to nCPAP in preterm infants needing noninvasive respiratory support and persistent oxygen supply after the first 72 h of life. STUDY DESIGN: Multicenter non-blinded prospective randomized crossover study. PATIENT SELECTION: Thirty premature infants from eight tertiary neonatal intensive care units, of mean ± SD 26.4 ± 1.8 weeks of gestational age and 921 ± 177 g of birth weight. METHODOLOGY: Infants were randomly allocated in a 1:1 ratio to receive a starting treatment mode of either nCPAP or nHFOV delivered by the ventilator CNO (Medin, Germany), using short binasal prongs of appropriate size. A crossover design with four 1-h treatment periods was used, such that each infant received both treatments twice. The primary outcome was the mean transcutaneous partial pressure of CO2 (TcCO2 ) value during the 2-h cumulative period of nHFOV compared with the 2-h cumulative period of nCPAP. RESULTS: Significantly lower TcCO2 values were observed during nHFOV compared with nCPAP: 47.5 ± 7.6 versus 49.9 ± 7.2 mmHg, respectively, P = 0.0007. A different TcCO2 behavior was found according to the random sequence: in patients starting on nCPAP, TcCO2 significantly decreased from 50.0 ± 8.0 to 46.6 ± 7.5 mmHg during nHFOV (P = 0.001). In patients starting on nHFOV, TcCO2 slightly increased from 48.5 ± 7.8 to 49.9 ± 6.7 mmHg during nCPAP (P = 0.13). CONCLUSIONS: nHFOV delivered through nasal prongs is more effective than nCPAP in improving the elimination of CO2 .


Assuntos
Dióxido de Carbono/química , Pressão Positiva Contínua nas Vias Aéreas/métodos , Ventilação de Alta Frequência , Ventilação com Pressão Positiva Intermitente/métodos , Desmame do Respirador/métodos , Peso ao Nascer , Estudos Cross-Over , Feminino , Idade Gestacional , Humanos , Lactente , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal , Itália , Lituânia , Masculino , Ventilação não Invasiva/métodos , Nariz/fisiologia , Estudos Prospectivos , Ventiladores Mecânicos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA