Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
J Am Coll Cardiol ; 84(1): 61-74, 2024 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-38864538

RESUMO

BACKGROUND: The ADVENT randomized trial revealed no significant difference in 1-year freedom from atrial arrhythmias (AA) between thermal (radiofrequency/cryoballoon) and pulsed field ablation (PFA). However, recent studies indicate that the postablation AA burden is a better predictor of clinical outcomes than the dichotomous endpoint of 30-second AA recurrence. OBJECTIVES: The goal of this study was to determine: 1) the impact of postablation AA burden on outcomes; and 2) the effect of ablation modality on AA burden. METHODS: In ADVENT, symptomatic drug-refractory patients with paroxysmal atrial fibrillation underwent PFA or thermal ablation. Postablation transtelephonic electrocardiogram monitor recordings were collected weekly or for symptoms, and 72-hour Holters were at 6 and 12 months. AA burden was calculated from percentage AA on Holters and transtelephonic electrocardiogram monitors. Quality-of-life assessments were at baseline and 12 months. RESULTS: From 593 randomized patients (299 PFA, 294 thermal), using aggregate PFA/thermal data, an AA burden exceeding 0.1% was associated with a significantly reduced quality of life and an increase in clinical interventions: redo ablation, cardioversion, and hospitalization. There were more patients with residual AA burden <0.1% with PFA than thermal ablation (OR: 1.5; 95% CI: 1.0-2.3; P = 0.04). Evaluation of outcomes by baseline demographics revealed that patients with prior failed class I/III antiarrhythmic drugs had less residual AA burden after PFA compared to thermal ablation (OR: 2.5; 95% CI: 1.4-4.3; P = 0.002); patients receiving only class II/IV antiarrhythmic drugs pre-ablation had no difference in AA burden between ablation groups. CONCLUSIONS: Compared with thermal ablation, PFA more often resulted in an AA burden less than the clinically significant threshold of 0.1% burden. (The FARAPULSE ADVENT PIVOTAL Trial PFA System vs SOC Ablation for Paroxysmal Atrial Fibrillation [ADVENT]; NCT04612244).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Recidiva , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Fibrilação Atrial/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Idoso , Qualidade de Vida , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-38934973

RESUMO

BACKGROUND: The autonomic nervous system plays an important role in atrial fibrillation (AF) and hypertension. Renal denervation (RDN) lowers blood pressure (BP), but its role in AF is poorly understood. OBJECTIVES: The purpose of this study was to investigate whether RDN reduces AF recurrence after pulmonary vein isolation (PVI). METHODS: This study randomized patients from 8 centers (United States, Germany) with drug-refractory AF for treatment with PVI+RDN vs PVI alone. A multielectrode radiofrequency Spyral catheter system was used for RDN. Insertable cardiac monitors were used for continuous rhythm monitoring. The primary efficacy endpoint was ≥2 minutes of AF recurrence or repeat ablation during all follow-up. The secondary endpoints included atrial arrhythmia (AA) burden, discontinuation of class I/III antiarrhythmic drugs, and BP changes from baseline. RESULTS: A total of 70 patients with AF (52 paroxysmal, 18 persistent) and uncontrolled hypertension were randomized (RDN+PVI, n = 34; PVI, n = 36). At 3.5 years, 26.2% and 21.4% of patients in RDN+PVI and PVI groups, respectively, were free from the primary efficacy endpoint (log rank P = 0.73). Patients with mean ≥1 h/d AA had less daily AA burden after RDN+PVI vs PVI (4.1 hours vs 9.2 hours; P = 0.016). More patients discontinued class I/III antiarrhythmic drugs after RDN+PVI vs PVI (45% vs 14%; P = 0.040). At 1 year, systolic BP changed by -17.8 ± 12.8 mm Hg and -13.7 ± 18.8 mm Hg after RDN+PVI and PVI, respectively (P = 0.43). The composite safety endpoint was not significantly different between groups. CONCLUSIONS: In patients with AF and uncontrolled BP, RDN+PVI did not prevent AF recurrence more than PVI alone. However, RDN+PVI may reduce AF burden and antiarrhythmic drug usage, but this needs further prospective validation.

4.
Heart Rhythm ; 2024 May 19.
Artigo em Inglês | MEDLINE | ID: mdl-38772432

RESUMO

BACKGROUND: Left bundle branch area pacing (LBBAP) has swiftly emerged as a safe and effective alternative to right ventricular pacing. Limited data exist on the use of retractable-helix, stylet-driven leads for LBBAP. OBJECTIVE: The objective of this study was to prospectively evaluate the performance and safety of a stylet-driven pacing lead in a rigorously controlled multicenter trial to support US market application. METHODS: A multicenter, prospective, nonrandomized trial enrolled patients with standard pacing indications. Implant procedure and lead data, including threshold, sensing, impedance, and capture type, were collected through 3 months. Primary end points were freedom from LBBAP lead-related serious complications through 3 months and LBBAP implant success according to prespecified criteria. A blinded clinical events committee adjudicated all potential end point complications. RESULTS: A total of 186 patients were included from 14 US sites. LBBAP implants were successful in 95.7% (178 of 186; 95% confidence interval 91.7%-98.1%; P < .0001 for comparison to the performance goal of 88%). Through the 3-month follow-up visit, 3 patients (1.7%) experienced a serious LBBAP complication (all lead dislodgments), resulting in a LBBAP lead-related complication-free rate of 98.3%. A total of 13 patients (7.8%) experienced any system- or procedure-related complication. The mean threshold was 0.89 V at 0.4 ms, the sensing value was 10.8 mV, and impedance was 608 Ω. CONCLUSION: The short-term results from this prospective trial demonstrate both high implant success and freedom from LBBAP lead-related complications using this stylet-driven retractable helix lead. This trial supports the safety, use, and effectiveness of stylet-driven leads for performing contemporary physiologic pacing.

5.
JACC Clin Electrophysiol ; 10(5): 956-966, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38703162

RESUMO

BACKGROUND: Prediction of drug-induced long QT syndrome (diLQTS) is of critical importance given its association with torsades de pointes. There is no reliable method for the outpatient prediction of diLQTS. OBJECTIVES: This study sought to evaluate the use of a convolutional neural network (CNN) applied to electrocardiograms (ECGs) to predict diLQTS in an outpatient population. METHODS: We identified all adult outpatients newly prescribed a QT-prolonging medication between January 1, 2003, and March 31, 2022, who had a 12-lead sinus ECG in the preceding 6 months. Using risk factor data and the ECG signal as inputs, the CNN QTNet was implemented in TensorFlow to predict diLQTS. RESULTS: Models were evaluated in a held-out test dataset of 44,386 patients (57% female) with a median age of 62 years. Compared with 3 other models relying on risk factors or ECG signal or baseline QTc alone, QTNet achieved the best (P < 0.001) performance with a mean area under the curve of 0.802 (95% CI: 0.786-0.818). In a survival analysis, QTNet also had the highest inverse probability of censorship-weighted area under the receiver-operating characteristic curve at day 2 (0.875; 95% CI: 0.848-0.904) and up to 6 months. In a subgroup analysis, QTNet performed best among males and patients ≤50 years or with baseline QTc <450 ms. In an external validation cohort of solely suburban outpatient practices, QTNet similarly maintained the highest predictive performance. CONCLUSIONS: An ECG-based CNN can accurately predict diLQTS in the outpatient setting while maintaining its predictive performance over time. In the outpatient setting, our model could identify higher-risk individuals who would benefit from closer monitoring.


Assuntos
Inteligência Artificial , Eletrocardiografia , Síndrome do QT Longo , Redes Neurais de Computação , Humanos , Feminino , Masculino , Síndrome do QT Longo/induzido quimicamente , Síndrome do QT Longo/diagnóstico , Pessoa de Meia-Idade , Idoso , Adulto , Fatores de Risco
6.
Heart Rhythm ; 2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38490597

RESUMO

BACKGROUND: Many patients with mildly to moderately reduced left ventricular ejection fraction (LVEF) who require permanent pacemaker (PPM) implantation do not have a concurrent indication for implantable cardioverter-defibrillator (ICD) therapy. However, the risk of ventricular tachycardia/ventricular fibrillation (VT/VF) in this population is unknown. OBJECTIVE: The aim of this study was to describe the risk of VT/VF after PPM implantation in patients with mildly to moderately reduced LVEF. METHODS: Retrospective analysis was performed of 243 patients with LVEF between 35% and 49% who underwent PPM placement and did not meet indications for an ICD. The primary end point was occurrence of sustained VT/VF. Competing risks regression was performed to calculate subhazard ratios for the primary end point. RESULTS: Median follow-up was 27 months; 73% of patients were male, average age was 79 ± 10 years, average LVEF was 42% ± 4%, and 70% were New York Heart Association class II or above. Most PPMs were implanted for sick sinus syndrome (34%) or atrioventricular block (50%). Of 243 total patients, 11 (4.5%) met the primary end point of VT/VF. Multivessel coronary artery disease (CAD) was associated with significantly higher rates of VT/VF, with a subhazard ratio of 5.4 (95% CI, 1.5-20.1; P = .01). Of patients with multivessel CAD, 8 of 82 (9.8%) patients met the primary end point for an annualized risk of 4.3% per year. CONCLUSION: Patients with mildly to moderately reduced LVEF and multivessel CAD undergoing PPM implantation are at increased risk for the development of malignant ventricular arrhythmias. Patients in this population may benefit from additional risk stratification for VT/VF and consideration for upfront ICD implantation.

9.
J Interv Card Electrophysiol ; 67(1): 203-210, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36952090

RESUMO

OBJECTIVES: We investigated characteristics of left atrial conduction in patients with HCM, paroxysmal AF and normal bipolar voltage. BACKGROUND: Patients with hypertrophic cardiomyopathy (HCM) exhibit abnormal cardiac tissue arrangement. The incidence of atrial fibrillation (AF) is increased fourfold in patients with HCM and confers a fourfold increased risk of death. Catheter ablation is less effective in HCM, with twofold increased risk of AF recurrence. The mechanisms of AF perpetuation in HCM are poorly understood. METHODS: We analyzed 20 patients with HCM and 20 controls presenting for radiofrequency ablation of paroxysmal AF normal left atrial voltage(> 0.5 mV). Intracardiac electrograms were extracted from the CARTO mapping system and analyzed using Matlab/Python code interfacing with Core OpenEP software. Conduction velocity maps were calculated using local activation time gradients. RESULTS: There were no differences in baseline demographics, atrial size, or valvular disease between HCM and control patients. Patients with HCM had significantly reduced atrial conduction velocity compared to controls (0.44 ± 0.17 vs 0.56 ± 0.10 m/s, p = 0.01), despite no significant differences in bipolar voltage amplitude (1.23 ± 0.38 vs 1.20 ± 0.41 mV, p = 0.76). There was a statistically significant reduction in conduction velocity in the posterior left atrium in HCM patients relative to controls (0.43 ± 0.18 vs 0.58 ± 0.10 m/s, p = 0.003), but not in the anterior left atrium (0.46 ± 0.17 vs 0.55 ± 0.10 m/s, p = 0.05). There was a significant association between conduction velocity and interventricular septal thickness (slope = -0.013, R2 = 0.13, p = 0.03). CONCLUSIONS: Atrial conduction velocity is significantly reduced in patients with HCM and paroxysmal AF, possibly contributing to arrhythmia persistence after catheter ablation.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Cardiomiopatia Hipertrófica , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/etiologia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/complicações , Apêndice Atrial/cirurgia , Ablação por Cateter/efeitos adversos
11.
Kidney Int Rep ; 8(11): 2385-2394, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-38025214

RESUMO

Introduction: Excessive dialytic potassium (K) and acid removal are risk factors for arrhythmias; however, treatment-to-treatment dialysate modification is rarely performed. We conducted a multicenter, pilot randomized study to test the safety, feasibility, and efficacy of 4 point-of-care (POC) chemistry-guided protocols to adjust dialysate K and bicarbonate (HCO3) in outpatient hemodialysis (HD) clinics. Methods: Participants received implantable cardiac loop monitors and crossed over to four 4-week periods with adjustment of dialysate K or HCO3 at each treatment according to pre-HD POC values: (i) K-removal minimization, (ii) K-removal maximization, (iii) Acidosis avoidance, and (iv) Alkalosis avoidance. The primary end point was percentage of treatments adhering to the intervention algorithm. Secondary endpoints included pre-HD K and HCO variability, adverse events, and rates of clinically significant arrhythmias (CSAs). Results: Nineteen subjects were enrolled in the study. HD staff completed POC testing and correctly adjusted the dialysate in 604 of 708 (85%) of available HD treatments. There was 1 K ≤3, 29 HCO3 <20 and 2 HCO3 >32 mEq/l and no serious adverse events related to study interventions. Although there were no significant differences between POC results and conventional laboratory measures drawn concurrently, intertreatment K and HCO3 variability was high. There were 45 CSA events; most were transient atrial fibrillation (AF), with numerically fewer events during the alkalosis avoidance period (8) and K-removal maximization period (3) compared to other intervention periods (17). There were no significant differences in CSA duration among interventions. Conclusion: Algorithm-guided K/HCO3 adjustment based on POC testing is feasible. The variability of intertreatment K and HCO3 suggests that a POC-laboratory-guided algorithm could markedly alter dialysate-serum chemistry gradients. Definitive end point-powered trials should be considered.

13.
Cardiovasc Digit Health J ; 4(4): 126-132, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37600443

RESUMO

Background: A lack of explainability in published machine learning (ML) models limits clinicians' understanding of how predictions are made, in turn undermining uptake of the models into clinical practice. Objective: The purpose of this study was to develop explainable ML models to predict in-hospital mortality in patients hospitalized for myocardial infarction (MI). Methods: Adult patients hospitalized for an MI were identified in the National Inpatient Sample between January 1, 2012, and September 30, 2015. The resulting cohort comprised 457,096 patients described by 64 predictor variables relating to demographic/comorbidity characteristics and in-hospital complications. The gradient boosting algorithm eXtreme Gradient Boosting (XGBoost) was used to develop explainable models for in-hospital mortality prediction in the overall cohort and patient subgroups based on MI type and/or sex. Results: The resulting models exhibited an area under the receiver operating characteristic curve (AUC) ranging from 0.876 to 0.942, specificity 82% to 87%, and sensitivity 75% to 87%. All models exhibited high negative predictive value ≥0.974. The SHapley Additive exPlanation (SHAP) framework was applied to explain the models. The top predictor variables of increasing and decreasing mortality were age and undergoing percutaneous coronary intervention, respectively. Other notable findings included a decreased mortality risk associated with certain patient subpopulations with hyperlipidemia and a comparatively greater risk of death among women below age 55 years. Conclusion: The literature lacks explainable ML models predicting in-hospital mortality after an MI. In a national registry, explainable ML models performed best in ruling out in-hospital death post-MI, and their explanation illustrated their potential for guiding hypothesis generation and future study design.

16.
Adv Radiat Oncol ; 8(6): 101272, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37415904

RESUMO

Purpose: Cardiac radioablation is an emerging therapy for recurrent ventricular tachycardia. Electrophysiology (EP) data, including electroanatomic maps (EAM) and electrocardiographic imaging (ECGI), provide crucial information for defining the arrhythmogenic target volume. The absence of standardized workflows and software tools to integrate the EP maps into a radiation planning system limits their use. This study developed a comprehensive software tool to enable efficient utilization of the mapping for cardiac radioablation treatment planning. Methods and Materials: The tool, HeaRTmap, is a Python-scripted plug-in module on the open-source 3D Slicer software platform. HeaRTmap is able to import EAM and ECGI data and visualize the maps in 3D Slicer. The EAM is translated into a 3D space by registration with cardiac magnetic resonance images (MRI) or computed tomography (CT). After the scar area is outlined on the mapping surface, the tool extracts and extends the annotated patch into a closed surface and converts it into a structure set associated with the anatomic images. The tool then exports the structure set and the images as The Digital Imaging and Communications in Medicine Standard in Radiotherapy for a radiation treatment planning system to import. Overlapping the scar structure on simulation CT, a transmural target volume is delineated for treatment planning. Results: The tool has been used to transfer Ensite NavX EAM data into the Varian Eclipse treatment planning system in radioablation on 2 patients with ventricular tachycardia. The ECGI data from CardioInsight was retrospectively evaluated using the tool to derive the target volume for a patient with left ventricular assist device, showing volumetric matching with the clinically used target with a Dice coefficient of 0.71. Conclusions: HeaRTmap smoothly fuses EP information from different mapping systems with simulation CT for accurate definition of radiation target volume. The efficient integration of EP data into treatment planning potentially facilitates the study and adoption of the technique.

17.
JACC Clin Electrophysiol ; 9(2): 246-254, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36858692

RESUMO

BACKGROUND: Prolongation of the QTc interval is associated with the risk of torsades de pointes. Determination of the QTc interval is therefore of critical importance. There is no reliable method for measuring or correcting the QT interval in atrial fibrillation (AF). OBJECTIVES: The authors sought to evaluate the use of a convolutional neural network (CNN) applied to AF electrocardiograms (ECGs) for accurately estimating the QTc interval and ruling out prolongation of the QTc interval. METHODS: The authors identified patients with a 12-lead ECG in AF within 10 days of a sinus ECG, with similar (±10 ms) QRS durations, between October 23, 2001, and November 5, 2021. A multilayered deep CNN was implemented in TensorFlow 2.5 (Google) to predict the MUSE (GE Healthcare) software-generated sinus QTc value from an AF ECG waveform, demographic characteristics, and software-generated features. RESULTS: The study identified 6,432 patients (44% female) with an average age of 71 years. The CNN predicted sinus QTc values with a mean absolute error of 22.2 ms and root mean squared error of 30.6 ms, similar to the intrinsic variability of the sinus QTc interval. Approximately 84% and 97% of the model's predictions were contained within 1 SD (±30.6 ms) and 2 SD (±61.2 ms) from the sinus QTc interval. The model outperformed the AFQTc method, exhibiting narrower error ranges (mean absolute error comparison P < 0.0001). The model performed best for ruling out QTc prolongation (negative predictive value 0.82 male, 0.92 female; specificity 0.92 male, 0.97 female). CONCLUSIONS: A CNN model applied to AF ECGs accurately predicted the sinus QTc interval, outperforming current alternatives and exhibiting a high negative predictive value.


Assuntos
Fibrilação Atrial , Torsades de Pointes , Humanos , Feminino , Masculino , Idoso , Algoritmos , Redes Neurais de Computação , Software
18.
Heart Rhythm ; 20(6): 808-814, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-36863636

RESUMO

BACKGROUND: Established electroanatomic mapping techniques for substrate mapping for ventricular tachycardia (VT) ablation includes voltage mapping, isochronal late activation mapping (ILAM), and fractionation mapping. Omnipolar mapping (Abbott Medical, Inc.) is a novel optimized bipolar electrogram creation technique with integrated local conduction velocity annotation. The relative utilities of these mapping techniques are unknown. OBJECTIVE: The purpose of this study was to evaluate the relative utility of various substrate mapping techniques for the identification of critical sites for VT ablation. METHODS: Electroanatomic substrate maps were created and retrospectively analyzed in 27 patients in whom 33 VT critical sites were identified. RESULTS: Both abnormal bipolar voltage and omnipolar voltage encompassed all critical sites and were observed over a median of 66 cm2 (interquartile range [IQR] 41.3-86 cm2) and 52 cm2 (IQR 37.7-65.5 cm2), respectively. ILAM deceleration zones were observed over a median of 9 cm2 (IQR 5.0-11.1 cm2) and encompassed 22 critical sites (67%), while abnormal omnipolar conduction velocity (CV <1 mm/ms) was observed over 10 cm2 (IQR 5.3-16.6 cm2) and identified 22 critical sites (67%), and fractionation mapping was observed over a median of 4 cm2 (IQR 1.5-7.6 cm2) and encompassed 20 critical sites (61%). The mapping yield was the highest for fractionation + CV (2.1 critical sites/cm2) and least for bipolar voltage mapping (0.5 critical sites/cm2). CV identified 100% of critical sites in areas with a local point density of >50 points/cm2. CONCLUSION: ILAM, fractionation, and CV mapping each identified distinct critical sites and provided a smaller area of interest than did voltage mapping alone. The sensitivity of novel mapping modalities improved with greater local point density.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Estudos Retrospectivos , Técnicas Eletrofisiológicas Cardíacas/métodos , Ablação por Cateter/métodos
19.
J Cardiovasc Electrophysiol ; 34(4): 942-946, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36738141

RESUMO

INTRODUCTION: Radiofrequency ablation (RFA) slow pathway modification for catheter ablation of atrioventricular nodal reentrant tachycardia (AVNRT) is traditionally performed using a 4-mm nonirrigated (NI) RF ablation catheter. Slow pathway modification using irrigated, contact-force sensing (ICFS) RFA catheters has been described in case reports, but the outcomes have not been systematically evaluated. METHODS: Acute procedural outcomes of 200 consecutive patients undergoing slow pathway modification for AVNRT were analyzed. A 3.5-mm ICFS RFA catheter (ThermoCool SmartTouch STSF, Biosense Webster, Inc.) was utilized in 134 patients, and a 4-mm NI RFA catheter (EZ Steer, Biosense Webster, Inc.) was utilized in 66 patients. Electroanatomic maps were retrospectively analyzed in a blinded fashion to determine the proximity of ablation lesions to the His region. RESULTS: The baseline characteristics of patients in both groups were similar. Total RF time was significantly lower in the ICFS group compared to the NI group (5.53 ± 4.6 vs. 6.24 ± 4.9 min, p = 0.03). Median procedure time was similar in both groups (ICFS, 108.0 (87.5-131.5) min vs. NI, 100.0 (85.0-125.0) min; p = 0.2). Ablation was required in closer proximity to the His region in the NI group compared to the ICFS group (14.4 ± 5.9 vs. 16.7 ± 6.4 mm, respectively, p = 0.01). AVNRT was rendered noninducible in all patients, and there was no arrhythmia recurrence during follow-up in both groups. Catheter ablation was complicated by AV block in one patient in the NI group. CONCLUSION: Slow pathway modification for catheter ablation of AVNRT using an ICFS RFA catheter is feasible, safe, and may facilitate shorter duration ablation while avoiding ablation in close proximity to the His region.


Assuntos
Ablação por Cateter , Ablação por Radiofrequência , Taquicardia por Reentrada no Nó Atrioventricular , Humanos , Estudos Retrospectivos , Catéteres
20.
J Cardiovasc Electrophysiol ; 34(4): 800-807, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36738147

RESUMO

INTRODUCTION: Radiofrequency ablation technology for treating atrial fibrillation (AF) has evolved rapidly over the past decade. We investigated the impact of technological and procedural advances on procedure times and ablation outcomes at a major academic medical center over a 10-year period. METHODS: Clinical data was collected from patients who presented to NYU Langone Health between 2011 and 2021 for a first-time AF ablation. Time to redo AF ablation or direct current cardioversion (DCCV) for recurrent AF during a 3-year follow-up period was determined and correlated with ablation technology and practices, antiarrhythmic medications, and patient comorbid conditions. RESULTS: From 2011 to 2021, the cardiac electrophysiology lab adopted irrigated-contact force ablation catheters, high-power short duration ablation lesions, steady-pacing, jet ventilation, and eliminated stepwise linear ablation for AF ablation. During this time the number of first time AF ablations increased from 403 to 1074, the percentage of patients requiring repeat AF-related intervention within 3-years of the index procedure dropped from 22% to 14%, mean procedure time decreased from 271 ± 65 to 135 ± 36 min, and mean annual major adverse event rate remained constant at 1.1 ± 0.5%. Patient comorbid conditions increased during this time period and antiarrhythmic use was unchanged. CONCLUSION: Rates of redo-AF ablation or DCCV following an initial AF ablation at a single center decreased 36% over a 10-year period. Procedural and technological changes likely contributed to this improvement, despite increased AF related comorbidities.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Antiarrítmicos/uso terapêutico , Fatores de Tempo , Ablação por Cateter/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA