Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Adv Sci (Weinh) ; 5(9): 1800121, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30250782

RESUMO

One out of every six American women has been the victim of a sexual assault in their lifetime. However, the DNA casework backlog continues to increase outpacing the nation's capacity since DNA evidence processing in sexual assault casework remains a bottleneck due to laborious and time-consuming differential extraction of victim's and perpetrator's cells. Additionally, a significant amount (60-90%) of male DNA evidence may be lost with existing procedures. Here, a microfluidic method is developed that selectively captures sperm using a unique oligosaccharide sequence (Sialyl-LewisX), a major carbohydrate ligand for sperm-egg binding. This method is validated with forensic mock samples dating back to 2003, resulting in 70-92% sperm capture efficiency and a 60-92% reduction in epithelial fraction. Captured sperm are then lysed on-chip and sperm DNA is isolated. This method reduces assay-time from 8 h to 80 min, providing an inexpensive alternative to current differential extraction techniques, accelerating identification of suspects and advancing public safety.

2.
Adv Sci (Weinh) ; 5(2): 1700531, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29610725

RESUMO

Male infertility is a reproductive disease, and existing clinical solutions for this condition often involve long and cumbersome sperm sorting methods, including preprocessing and centrifugation-based steps. These methods also fall short when sorting for sperm free of reactive oxygen species, DNA damage, and epigenetic aberrations. Although several microfluidic platforms exist, they suffer from structural complexities, i.e., pumps or chemoattractants, setting insurmountable barriers to clinical adoption. Inspired by the natural filter-like capabilities of the female reproductive tract for sperm selection, a model-driven design, featuring pillar arrays that efficiently and noninvasively isolate highly motile and morphologically normal sperm, with lower epigenetic global methylation, from raw semen, is presented. The Simple Periodic ARray for Trapping And isolatioN (SPARTAN) created here modulates the directional persistence of sperm, increasing the spatial separation between progressive and nonprogressive motile sperm populations within an unprecedentedly short 10 min assay time. With over 99% motility of sorted sperm, a 5-fold improvement in morphology, 3-fold increase in nuclear maturity, and 2-4-fold enhancement in DNA integrity, SPARTAN offers to standardize sperm selection while eliminating operator-to-operator variations, centrifugation, and flow. SPARTAN can also be applied in other areas, including conservation ecology, breeding of farm animals, and design of flagellar microrobots for diagnostics.

3.
Sci Rep ; 6: 39144, 2016 12 22.
Artigo em Inglês | MEDLINE | ID: mdl-28004818

RESUMO

Cancer cells have been increasingly grown in pharmaceutical research to understand tumorigenesis and develop new therapeutic drugs. Currently, cells are typically grown using two-dimensional (2-D) cell culture approaches, where the native tumor microenvironment is difficult to recapitulate. Thus, one of the main obstacles in oncology is the lack of proper infection models that recount main features present in tumors. In recent years, microtechnology-based platforms have been employed to generate three-dimensional (3-D) models that better mimic the native microenvironment in cell culture. Here, we present an innovative approach to culture Kaposi's sarcoma-associated herpesvirus (KSHV) infected human B cells in 3-D using a microwell array system. The results demonstrate that the KSHV-infected B cells can be grown up to 15 days in a 3-D culture. Compared with 2-D, cells grown in 3-D had increased numbers of KSHV latency-associated nuclear antigen (LANA) dots, as detected by immunofluorescence microscopy, indicating a higher viral genome copy number. Cells in 3-D also demonstrated a higher rate of lytic reactivation. The 3-D microwell array system has the potential to improve 3-D cell oncology models and allow for better-controlled studies for drug discovery.


Assuntos
Antígenos Virais/genética , Linfócitos B/virologia , Técnicas de Cultura de Células/instrumentação , Regulação Viral da Expressão Gênica , Herpesvirus Humano 8/fisiologia , Proteínas Nucleares/genética , Antígenos Virais/metabolismo , Linhagem Celular Tumoral , Humanos , Proteínas Nucleares/metabolismo , Carga Viral , Ativação Viral , Latência Viral/genética
4.
Trends Biotechnol ; 34(11): 909-921, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27344425

RESUMO

Point-of-care (POC) diagnostics play an important role in delivering healthcare, particularly for clinical management and disease surveillance in both developed and developing countries. Currently, the majority of POC diagnostics utilize paper substrates owing to affordability, disposability, and mass production capability. Recently, flexible polymer substrates have been investigated due to their enhanced physicochemical properties, potential to be integrated into wearable devices with wireless communications for personalized health monitoring, and ability to be customized for POC diagnostics. Here, we focus on the latest advances in developing flexible substrate-based diagnostic devices, including paper and polymers, and their clinical applications.


Assuntos
Técnicas Analíticas Microfluídicas/instrumentação , Monitorização Fisiológica/instrumentação , Sistemas Automatizados de Assistência Junto ao Leito , Vestuário , Humanos , Dispositivos Lab-On-A-Chip , Papel , Maleabilidade , Polímeros , Têxteis
5.
Mater Sci Eng C Mater Biol Appl ; 45: 337-42, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25491837

RESUMO

An optical nanobiosensor is presented using a fluorescent dye and anti-E. coli McAb anchored Ag@Silica core shell nanoparticles, for rapid and sensitive Escherichia coli detection in environmental samples. The synthesized dual labeled core shell (DLCS) nanoparticle shows intense fluorescence at 620 nm in solution, having a narrow emission with full width at half maxima (FWHM) of 10 nm, as a prerequisite to develop a sensitive detection platform for various biosensing applications. The specific E. coli was captured using an anti-E. coli antibody functionalized quartz glass, followed by a treatment with DLCS, where the photoluminescence spectroscopy was used to detect the target pathogen. The fabrication of the quartz glass based optical-immunosensor was monitored, and the results show changes in the photoluminescent patterns, which substantiate that varied species were immobilized on the surface of the antibody modified quartz glass. Consequently, the optical immunosensor demonstrated specificity and improved sensitivity, as compared to the customary methods, and was able to detect as low as 5CFU/mL. The developed DLCS based optical immunosensor was evaluated with environmental water samples, which showed acceptable precision, reproducibility and stability, and could be readily applied to the routine monitoring of pathogenic microorganisms in the environmental samples, and most importantly, demonstrate the potential of a prototype development of a simple and inexpensive diagnostic technique.


Assuntos
Técnicas Biossensoriais , Escherichia coli/isolamento & purificação , Nanopartículas/química , Dióxido de Silício/química , Prata/química , Corantes Fluorescentes/química , Limite de Detecção , Sensibilidade e Especificidade
6.
Clin Chem ; 60(9): 1209-16, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25006224

RESUMO

BACKGROUND: Sophisticated equipment, lengthy protocols, and skilled operators are required to perform protein microarray-based affinity assays. Consequently, novel tools are needed to bring biomarkers and biomarker panels into clinical use in different settings. Here, we describe a novel paper-based vertical flow microarray (VFM) system with a multiplexing capacity of at least 1480 microspot binding sites, colorimetric readout, high sensitivity, and assay time of <10 min before imaging and data analysis. METHOD: Affinity binders were deposited on nitrocellulose membranes by conventional microarray printing. Buffers and reagents were applied vertically by use of a flow controlled syringe pump. As a clinical model system, we analyzed 31 precharacterized human serum samples using the array system with 10 allergen components to detect specific IgE reactivities. We detected bound analytes using gold nanoparticle conjugates with assay time of ≤10 min. Microarray images were captured by a consumer-grade flatbed scanner. RESULTS: A sensitivity of 1 ng/mL was demonstrated with the VFM assay with colorimetric readout. The reproducibility (CV) of the system was <14%. The observed concordance with a clinical assay, ImmunoCAP, was R(2) = 0.89 (n = 31). CONCLUSIONS: In this proof-of-concept study, we demonstrated that the VFM assay, which combines features from protein microarrays and paper-based colorimetric systems, could offer an interesting alternative for future highly multiplexed affinity point-of-care testing.


Assuntos
Alérgenos/análise , Imunoglobulina E/sangue , Análise Serial de Proteínas , Colorimetria , Ouro/química , Humanos , Nanopartículas Metálicas/química , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
7.
Analyst ; 139(10): 2348-54, 2014 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-24690935

RESUMO

There is a growing need for multiplexed specific IgE tests that can accurately evaluate patient sensitization profiles. However, currently available commercial tests are either single/low-plexed or require sophisticated instrumentation at considerable cost per assay. Here, we present a novel convenient lateral flow microarray-based device that employs a novel dual labelled gold nanoparticle-strategy for rapid and sensitive detection of a panel of 15 specific IgE responses in 35 clinical serum samples. Each gold nanoparticle was conjugated to an optimized ratio of HRP and anti-IgE, allowing significant enzymatic amplification to improve the sensitivity of the assay as compared to commercially available detection reagents. The mean inter-assay variability of the developed LFM assay was 12% CV, and analysis of a cohort of clinical samples (n = 35) revealed good general agreement with ImmunoCAP, yet with a varying performance among allergens (AUC = [0.54-0.88], threshold 1 kU). Due to the rapid and simple procedure, inexpensive materials and read-out by means of a consumer flatbed scanner, the presented assay may provide an interesting low-cost alternative to existing multiplexed methods when thresholds >1 kU are acceptable.


Assuntos
Hipersensibilidade/diagnóstico , Papel , Sistemas Automatizados de Assistência Junto ao Leito , Alérgenos/análise , Humanos , Imunoglobulina E/análise , Nanopartículas Metálicas , Microscopia Eletrônica de Transmissão , Sensibilidade e Especificidade , Espectrofotometria Ultravioleta
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA