Brachytherapy ; 22(5): 580-585, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37474438

RESUMO

PURPOSE: We present a case study of the treatment of localized squamous cell carcinoma on the glans penis with a custom-fabricated high-dose-rate (HDR) brachytherapy applicator. METHODS AND MATERIALS: A cylindrically shaped applicator was fabricated with eight embedded channels suitable for standard plastic brachytherapy catheters. An additional custom silicone bolus/sleeve was designed to be used with the 3D-printed applicator to provide an additional offset from the source to skin to reduce the surface dose and for patient comfort. RESULTS: The patient (recurrent cT1a penile cancer) underwent CT simulation, and the brachytherapy plan was created with a nominal prescription dose of 40 Gy in 10 fractions given bidaily to the surface, and 35 Gy at 5 mm depth. Dose coverage to the clinical target volume was 94% (D90). Most fractions were treated with only 5-10 min of setup time. Follow up visits up to 1 year showed no evidence of disease with no significant changes in urinary and sexual function and limited cosmetic detriment to the patient. CONCLUSIONS: Patient-specific organ-sparing HDR plesiotherapy using 3D printing technology can provide reliable and reproducible patient setup and may be effective in achieving disease control for superficial penile cancer, although preserving patient quality of life.


Assuntos
Braquiterapia , Neoplasias Penianas , Masculino , Humanos , Neoplasias Penianas/radioterapia , Neoplasias Penianas/patologia , Tratamentos com Preservação do Órgão , Dosagem Radioterapêutica , Braquiterapia/métodos , Qualidade de Vida , Planejamento da Radioterapia Assistida por Computador/métodos , Recidiva Local de Neoplasia , Impressão Tridimensional
2.
PLoS One ; 13(5): e0198065, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29847586

RESUMO

Multi-modality image-guided radiotherapy is the standard of care in contemporary cancer management; however, it is not common in preclinical settings due to both hardware and software limitations. Soft tissue lesions, such as orthotopic prostate tumors, are difficult to identify using cone beam computed tomography (CBCT) imaging alone. In this study, we characterized a research magnetic resonance (MR) scanner for preclinical studies and created a protocol for combined MR-CBCT image-guided small animal radiotherapy. Two in-house dual-modality, MR and CBCT compatible, phantoms were designed and manufactured using 3D printing technology. The phantoms were used for quality assurance tests and to facilitate end-to-end testing for combined preclinical MR and CBCT based treatment planning. MR and CBCT images of the phantoms were acquired utilizing a Varian 4.7 T scanner and XRad-225Cx irradiator, respectively. The geometry distortion was assessed by comparing MR images to phantom blueprints and CBCT. The corrected MR scans were co-registered with CBCT and subsequently used for treatment planning. The fidelity of 3D printed phantoms compared to the blueprint design yielded favorable agreement as verified with the CBCT measurements. The geometric distortion, which varied between -5% and 11% throughout the scanning volume, was substantially reduced to within 0.4% after correction. The distortion free MR images were co-registered with the corresponding CBCT images and imported into a commercial treatment planning software SmART Plan. The planning target volume (PTV) was on average 19% smaller when contoured on the corrected MR-CBCT images relative to raw images without distortion correction. An MR-CBCT based preclinical workflow was successfully designed and implemented for small animal radiotherapy. Combined MR-CBCT image-guided radiotherapy for preclinical research potentially delivers enhanced relevance to human radiotherapy for various disease sites. This novel protocol is wide-ranging and not limited to the orthotopic prostate tumor study presented in the study.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radioterapia Guiada por Imagem/métodos , Animais , Processamento de Imagem Assistida por Computador , Masculino , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador , Ratos
3.
Phys Med Biol ; 63(5): 055004, 2018 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-29405123

RESUMO

Accurate dose delivery in stereotactic partial breast irradiation (S-PBI) is challenging because of the target position uncertainty caused by breast deformation, the target volume changes caused by lumpectomy cavity shrinkage, and the target delineation uncertainty on simulation computed tomography (CT) images caused by poor soft tissue contrast. We have developed a volumetric ultrasound tomography (UST) image guidance system for prone position S-PBI. The system is composed of a novel 3D printed rotation water tank, a patient-specific resin breast immobilization cup, and a 1D array ultrasound transducer. Coronal 2D US images were acquired in 5° increments over a 360° range, and planes were acquired every 2 mm in elevation. A super-compounding technique was used to reconstruct the image volume. The image quality of UST was evaluated with a BB-1 breast phantom and BioZorb surgical marker, and the results revealed that UST offered better soft tissue contrast than CT and similar image quality to MR. In the evaluated plane, the size and location of five embedded objects were measured and compared to MR, which is considered as the ground truth. Objects' diameters and the distances between objects in UST differ by approximately 1 to 2 mm from those in MR, which showed that UST offers the image quality required for S-PBI. In future work we will develop a robotic system that will be ultimately implemented in the clinic.


Assuntos
Neoplasias da Mama/radioterapia , Mama/efeitos da radiação , Tomografia Computadorizada de Feixe Cônico/métodos , Posicionamento do Paciente , Imagens de Fantasmas , Ultrassonografia Mamária/métodos , Neoplasias da Mama/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional/métodos , Decúbito Ventral , Estudo de Prova de Conceito
4.
J Appl Clin Med Phys ; 16(4): 306-310, 2015 07 08.
Artigo em Inglês | MEDLINE | ID: mdl-26218992

RESUMO

Geometric or mechanical accuracy of kV and MV imaging systems of two Varian TrueBeam linacs have been monitored by two geomertirc calibration systems, Varian IsoCal geometric calibration system and home-developed gQA system. Results of both systems are cross-checked and the long-term geometric stabilities of linacs are evaluated. Two geometric calibration methodologies have been used to assess kV and MV imaging systems and their coincidence periodically on two TrueBeam linacs for about one year. Both systems analyze kV or MV projection images of special designed phantoms to retrieve geometric parameters of the imaging systems. The isocenters ­ laser isocenter and centers of rotations of kV imager and EPID ­ are then calculated, based on results of multiple projections from different angles. Long-term calibration results from both systems are compared for cross-checking. There are 24 sessions of side-by-side calibrations performed by both systems on two TrueBeam linacs. All the disagreements of isocenters between two calibrations systems are less than 1 mm with ± 0.1 mm SD. Most of the large disagreements occurred in vertical direction (AP direction), with an averaged disagreement of 0.45 mm. The average disagreements of isocenters are 0.09 mm in other directions. Additional to long-term calibration monitoring, for the accuracy test, special tests were performed by misaligning QA phantoms on purpose (5 mm away from setup isocenter in AP, SI, and lateral directions) to test the liability performance of both systems with the known deviations. The errors are within 0.5 mm. Both geometric calibration systems, IsoCal and gQA, are capable of detecting geometric deviations of kV and MV imaging systems of linacs. The long-term evaluation also shows that the deviations of geometric parameters and the geometric accuracies of both linacs are small and very consistent during the one-year study period.


Assuntos
Interpretação de Imagem Assistida por Computador/métodos , Aceleradores de Partículas/normas , Imagens de Fantasmas , Garantia da Qualidade dos Cuidados de Saúde/métodos , Radiometria/métodos , Tomografia Computadorizada por Raios X/métodos , Calibragem , Humanos , Aceleradores de Partículas/instrumentação , Software