Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 21(8)2021 Apr 14.
Artigo em Inglês | MEDLINE | ID: mdl-33920063

RESUMO

The fish-eye lens camera has a wide field of view that makes it effective for various applications and sensor systems. However, it incurs strong geometric distortion in the image due to compressive recording of the outer part of the image. Such distortion must be interpreted accurately through a self-calibration procedure. This paper proposes a new type of test-bed (the AV-type test-bed) that can effect a balanced distribution of image points and a low level of correlation between orientation parameters. The effectiveness of the proposed test-bed in the process of camera self-calibration was verified through the analysis of experimental results from both a simulation and real datasets. In the simulation experiments, the self-calibration procedures were performed using the proposed test-bed, four different projection models, and five different datasets. For all of the cases, the Root Mean Square residuals (RMS-residuals) of the experiments were lower than one-half pixel. The real experiments, meanwhile, were carried out using two different cameras and five different datasets. These results showed high levels of calibration accuracy (i.e., lower than the minimum value of RMS-residuals: 0.39 pixels). Based on the above analyses, we were able to verify the effectiveness of the proposed AV-type test-bed in the process of camera self-calibration.

2.
Sensors (Basel) ; 19(5)2019 Mar 10.
Artigo em Inglês | MEDLINE | ID: mdl-30857373

RESUMO

The fish-eye lens camera offers the advantage of efficient acquisition of image data through a wide field of view. However, unlike the popular perspective projection camera, a strong distortion effect appears as the periphery of the image is compressed. Such characteristics must be precisely analyzed through camera self-calibration. In this study, we carried out a fish-eye lens camera self-calibration while considering different types of test objects and projection models. Self-calibration was performed using the V-, A-, Plane-, and Room-type test objects. In the fish-eye lens camera, the V-type test object was the most advantageous for ensuring the accuracy of the principal point coordinates and focal length, because the correlations between parameters were relatively low. On the other hand, the other test objects were advantageous for ensuring the accuracy of distortion parameters because of the well-distributed image points. Based on the above analysis, we proposed, an accurate fish-eye lens camera self-calibration method that applies the V-type test object. The RMS-residuals of the proposed method were less than 1 pixel.

3.
Future Sci OA ; 4(5): FSO301, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29796304

RESUMO

AIM: An electrochemical urine dipstick probe biosensor has been demonstrated using molybdenum electrodes on nanoporous polyamide substrate for the quantitative detection of two inflammatory protein biomarkers, CRP and IL-6. MATERIALS & METHODS: The electrode interface was characterized using ζ-potential and Fourier transform infrared spectroscopy. Detection of biomarkers was demonstrated by measuring impedance changes associated with the dose concentrations of the two biomarkers. A proof of feasibility of point-of-care implementation of the biosensor was demonstrated using a portable electronics platform. RESULTS & CONCLUSION: Limit of detection of 1 pg/ml was achieved for CRP and IL-6 in human urine and synthetic urine buffers. The developed portable hardware demonstrated close correlation with benchtop equipment results.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA